13.03.2024 Views

ISSU portfolio

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7' - 0"<br />

A<br />

7' - 0"<br />

B<br />

9' - 8"<br />

C D E F G H<br />

4' - 8" 5' - 4" 3' - 0" 6' - 6" 7' - 0"<br />

Structural Strategy<br />

1<br />

12' - 6"<br />

2<br />

9' - 8"<br />

3<br />

6' - 3"<br />

4<br />

10 foot tall perimeter truss<br />

W 16 by 26<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

T.O Slab<br />

4787' - 0"<br />

The first floor my proposal is structured independently of the second floor. The first floor structure consist<br />

of of W 10 by 50 steel columns with W 16 by 26 steel beams.<br />

The second floor is supported by reinforced concrete cores rather than columns. And rather than<br />

spanning the short dimension using steel beams I chose to use 45 by 4 foot 16 in thick hollowcore<br />

planks. These planks rest on top of steel trusses positioned inbetween the concrete cores in the long<br />

direction.<br />

The roof of the second floor is supported by two large steel and or concrete trusses that runs along the<br />

perimeter of the second floor in the long direction.<br />

16' - 0"<br />

5<br />

9' - 0"<br />

6<br />

8<br />

16' - 0"<br />

10<br />

16' - 0"<br />

11<br />

3' - 0"<br />

11<br />

W 16 by 26<br />

W 16 by 26<br />

W 16 by 26<br />

W 16 by 26<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

4" corrugated<br />

metal deck w.<br />

2" concrete<br />

topping<br />

T.O Slab<br />

4787' - 0"<br />

I also have yet to decide whether or not I want to use the hollowcore planks again for the roof to remove<br />

the need for columns or whether a thinner metal deck would be more appropriate. If I chose metal deck<br />

for the roof this would obviously require me to add columns.<br />

Hollowore Plank<br />

I like the choice of prestressed hollowcore plank to support the second level because it reduces the<br />

need to for steel beams and allows for a more compact section.<br />

The typical size of each plank is 4 by 50 with the exception of a few planks that vary. While this may<br />

seem too big for transport I figure that there may be some way trains can be used to transport these<br />

pieces to the site.<br />

1' - 4"<br />

0' - 1" 0' - 6" 0' - 11" 2' - 6"<br />

13' - 0"<br />

12<br />

W 16 by 26<br />

16' - 0"<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

T.O Slab<br />

4787' - 0"<br />

13<br />

W 16 by 26<br />

13' - 0"<br />

14<br />

3' - 0"<br />

15<br />

W 16 by 26<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

16' - 0"<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

16<br />

4' - 0"<br />

17<br />

2' - 6"<br />

18<br />

9' - 8"<br />

19<br />

W 16 by 26<br />

W 16 by 26<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

T.O Slab<br />

4787' - 0"<br />

16' - 0"<br />

W 16 by 26<br />

20<br />

3' - 0"<br />

21<br />

10 foot tall perimeter truss<br />

14' - 0"<br />

22<br />

15' - 3"<br />

W 16 by 26<br />

23<br />

16' - 0"<br />

W 16 by 26<br />

24<br />

10 foot tall perimeter truss<br />

14' - 0"<br />

4" corrugated<br />

metal deck w.<br />

2" concrete<br />

topping<br />

25<br />

3' - 0"<br />

26<br />

9' - 0"<br />

27<br />

3' - 0"<br />

28<br />

3' - 0" W 16 by 26<br />

29<br />

16' - 0"<br />

W 16 by 26<br />

30<br />

Roof Plan<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

T.O.C 4786" - 6"<br />

W 10x50<br />

T.O Slab<br />

4787' - 0"<br />

Assignment 4 Structure

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!