WHO <strong>Distribution</strong> <strong>Plan</strong> <strong>Phase</strong> X- <strong>3NG</strong><br />

Sector: Health Repair<br />

Code Commodity Quantity<br />

02-07-01676 CARDIART 8108, mains and internal battery with autonomy of 70 ECG recordings (auto Switch-off)<br />

high resolution thermal head-height of useful print area-108 mm. DOT-CARD 130mm. In 25m rolls<br />

(more than 80 tracings with 6 channel format) or equivalent. 5 mm/s (+ 10%) 25 and 50 mm/s (+ 5%) and<br />

auto simultaneous acqusition of the 12 standard leads class I, type CF, according to the medical device<br />

directives 93/42/CEE and directives EN 60 601-1, EN 60 601-1-2. digital to reduce muscular tremors, to<br />

eleminate mains interference and to stabilize the baseline without tracing distortion. 10 seconds of the 12<br />

leads (isochronous mode) internal at the apparatus according to the present requirements. Auto test system<br />

and operation check patient cable, 10 AGCI electrodes. chart paper, gel, user's manual all in English.<br />

dimentions 24.5 x 25.5 x 6.5 cm, weight 2.57 kg. with additional batteries, spare parts and accessories,<br />

#(8108)<br />

10<br />

02-07-01677 MARS TM 8000 Clinical Review Station. The system can simultaneously acquire, display and print data<br />

on up to 64 beds. admitting a patient at the solar. transcope, or Eagle monitor or centralscope. "Alarm<br />

Event Reveiw" up to 64 patients and for as long as 28 hours (min), wave forms: Eagle, solar or Transcape<br />

monitors: ECG channels II,V and blood pressure channels ART,PA. CD telemetry-LAN system: ECG<br />

channels I,II,III,V. SUN SPARCstation 20 WORKSTATION model 502, Ethernet interface,<br />

SPARCstation 20SX model 502 graphic display, AT 101 Keyboard, 3-button mouse, ONEAC UPS,<br />

SPARCprinter II, 5Gb tape drive, Solaris operating environment with open windws windowing system,<br />

220 VAC- 50Hz, installation, one year warrenty, spare parts & accessories for one year of operation,<br />

manuals in English and training for 2 doctors, 2 engineers and 4 paramedical staff.<br />

1<br />

02-07-01678 MULTI VIEW Workstation (6484 708 E323U) Display up to 16 patients on a single screen. Content-<br />

Sensitive on-line help. Expandability through software upgrade path. Complete access to all bedside<br />

information from one central location. Dual display option. color display monitor INFINITY modular<br />

monitor. Configuaration: remote control of alarms, user-configuarable main screen layouts. reveiw of<br />

graphical and tubular trends. Electronic white board for notes. remote control of Arrythmia set-ups.<br />

specifications:CRT screen SVGA compatible size: (17 inch) diagonal. waveforms: upto 8 full screen or<br />

upto 16 split screen. Viewing area: (15.7 inches) diagonal (11.8 x 8.9 inch) with resolution: 1280 x 1024<br />

pixels. inputs: Video and Sync. audio. Audio outputs: dual speakers. 2 w each (typical). frequency<br />

response:100 Hz to 20Hz (typical). Options: 9-16 Patients basic level option 51 90 678 e 5344. Qwerty<br />

Keybord. 47 25 375 E 534, with installation, spare parts & accesories for one year, training for Doctors<br />

Engineers.<br />

02-07-01679 INFINITY Telemetry Sytem. For cardiac assessment. Seamless integration of bedside and telemetry<br />

information store upto 1,000 arrythmia, alarm, and manual events per patient. Quick bedside ECG<br />

display. ST Segment analysis aids in detecting ischemia defore infarct and injury. Cardiology Rivew<br />

station: In-depth analysis of 12-lead ST information. Multiview workstation. on-line event disclosure.<br />

Transmitter Status: check transmittion quality quickly with low battery and lead-off indicators on the<br />

transmitter. Oxygene saturation option: by connecting a Micro O 2 portable pulse oximeter. the Tele DX<br />

Screen. with all the accessories, spare parts. #(64 93 329 E310U)<br />

02-07-01680 Pathfinder 500 FCR series Complete holter system The system is consisting of 12 Reynolds <strong>Medical</strong>'s<br />

Life Card 3 digital ambulatory ECG recorders. Lifecard specifications: channels 3. Memory size: 20<br />

Mbyte. Resolution: 8 bit. Storage medium flash EEPROM PC card, data access/Download Via PCMCIA<br />

interface. sampling rate: 128 samples a second. Full scale signal input +/- 5 millivolts. input impedance: 5<br />

Mohm. Battery: two 1.5 volts alkaline AA. weight 275 g. the pathfinder 500 FCR series specifications:<br />

analysis time: 6 minutes for 24 hour ECG. No. of channels 3. Main memory 180 Mbyte RAM. With the<br />

following features: Arythmia analysis, ST segment analysis, Pacemaker detection, HRV time domain<br />

analysis, HRV spectral analysis via network, Networking Hardware & software, 3 user defined<br />

morphology, 220VAC- 50Hz, 1.5 Gigabyte Disk, 17 inch colour monitor, laser printer with at least 8<br />

pages/ min., with all accessories including additional 40 flash memory cards and training for doctors.<br />

1<br />

02-07-01681 VICOM-sm-Systems (monitoring) cosist of ten (10) compact Monitors, Universal Monitors, One<br />

Central Stations and Printers. For intensive Care Units. -SMR 821 with 8-channel printer with network<br />

capability, and the integration of additional central stations allow this system to be exactly as required. -<br />

SMU-EVO 17 inches colour diplay, part number 101122 12 size: 440 x 145 x 435. weight: approx 10 kg.<br />

power supply 220 V. -HELAN Network. software for central stations monitor (bed access) part number:<br />

455016 01. - installation spare parts and accessories. -Training for 2 doctors, and 2 para medical staff.<br />