WHO <strong>Distribution</strong> <strong>Plan</strong> <strong>Phase</strong> X- <strong>3NG</strong><br />

Sector: Health Repair<br />

Code Commodity Quantity<br />

02-07-02295 Flame Photometers, Simultaneous reading of Na and K with internal lithium standard. Automatic reading 5<br />

of Li with internal K standard. Automatic blanking. Automatic calibration with memorization of<br />

reference values. Constant flame energy control. Serum and Lithium program memorization. Open<br />

program for Na and K determination on soil samples and chemical solutions. Automatic start up with<br />

flame control. Gas line security system. Autonomous air supply system. Incorporate thermal printer.<br />

power supply 220 V, 50 Hz. weight 10 kg. dimentions (35 x 25 x 35)cm HXWXD. with all accessories<br />

and spare parts. #(FP10)<br />

02-07-02296 Flame Photometers, Simultaneous reading of Na and K with internal lithium standard. Automatic reading 5<br />

of Li with internal K standard. Automatic blanking. Automatic calibration with memorization of<br />

reference values. Constant flame energy control. Serum and Lithium program memorization. Open<br />

program for Na and K determination on soil samples and chemical solutions. Automatic start up with<br />

flame control. Gas line security system. Autonomous air supply system.Incorporate sample dilution<br />

system. Incorporate thermal printer. power supply 220 V, 50 Hz. weight 10 kg. dimentions (35 x 25 x<br />

35)cm HXWXD. with all accessories and spare parts. #(FP20)<br />

02-07-02297 UV-Visible Spectrophotometer. 2000 Series. Self test and calibration, UV lamp 1500 hours guarantee,<br />

UV lamp save, Auto lamp and filter selection, with screen display with scrolling of 430mm<br />

width.automatic peak seek with baseline flattening., integral printer, monochromator optical system,<br />

wavelength range 190-1000nm; 325-1000nm. with extra lamps and accessories for one year of operation.<br />

02-07-02298 Digital Spectrophotometer (Spectronic 2000) microprocessor controlled. With print value shown on data<br />

display. In sequential mode, print sample ID number, wave-length, photometric value, operating mode. At<br />

the end of each scan, print out all programmed instrument conditions for easy, sure test duplication any<br />

time. selectable scan speed. with accessories. #(14450)<br />

5<br />

02-07-02299 New Clinical Chemistry Photometer (SLIM), for all clinical chemistry tests on sera, plasma and whole<br />

blood, reading method (absorbance,end point kinetik,fixed time and differential with standard or K<br />

factor). Halogen lamp of 20 W, 6 interferential filters, 340,405,505,546,578,630nm, with an accuracy of<br />

+2nm, band width of 8nm. photometric linearity from 0.3000 to 2.9999 O.D. resolution 0.0001 O.D.<br />

automatic withdrawal and wash cycle . tempreature regulation from 200C to 400C with 10C resolution.<br />

all photometer functions are managed by a FLASH memory microprocessor. 150 programmable<br />

programs. automatic print out of results, calibration and kinetic curves. fitting types: linear,point to point<br />

and cubic. pathological warnings. autodiagnosis. functional alphanumerical keyboard. Alphanumerical<br />

liquid crystal display . Thermal graphical printer. Power supply of 220 V, 50 Hz. With additioal halogen<br />

lamps and accessories and spare parts for one year of operation. Installation and training.<br />

3<br />

02-07-02300 Blood glucose monitors portable, reflectance photometry, with monitor, normal control solution, lancets,<br />

10 test strips, glucolet lancing device, chck paddle, log book. With additional 1000 strips and all<br />

accessories.<br />

250<br />

02-07-02301 Hemat 8,with working capacity of 60 samples. Automatic, the orifice diameter 120micrometers for WBC, 5<br />

70 micrometers for RBC,PLT. Counting time 60 sec. Sample size 20 microliters. Size dimentions (H.<br />

50CM, W. 66CM., D. 47CM.) Weight 32 kg. Power supply 200 V, 50 Hz. with cell distribution<br />

histogram. all spare parts and additional accessories. #(H 8 )<br />

02-07-02302 Screen Master, semiautomatic interential filter analyzer for clinical chemistry, with photometric reading<br />

system, long life 2W lamp light source. Solid state sensor. Automatic blanking. Reading field (-<br />

0,500/2.500 O.D.). Linearity +1%. Repeatability +1 digit. number of filters 6. wavelength 340nm, 405nm,<br />

505nm, 546nm, 578nm, 630nm. 10 positions,dry incubator. 370.tempreature. 101 stabiling time.softtouch,16<br />

keys keyboard. liquid crystal-numerical display. dimentions 36 x 33 x 18cm. weight 4.5 kg.<br />

power supply of 220 V, 50 Hz. with additional accessories and spare parts.<br />

5<br />

02-07-02303 Blood Apherisis unit, for automatic Apherisis collection and reinfusion of blood components. For<br />

plateletphoresis, Leukocytphoresis, Mononeuclear cell collection, exchange of plasma, Lympho/ Plasma<br />

and Red cells. Therapeutic of removal ymphocytes, granulocytes, platelets and bone Marrow process,<br />

with single/ dual needle, Monitors/Alarm for air detection, pressure levels, fluid level, flow, collection<br />

concentration, with all accessories, consumable and spare parts for one year of operation, installation and<br />

training.<br />

2<br />

02-07-02304 Knifes for rotatory microtome, knife, profile C, 16cm long. #(MNT-455-030E Alt.No. 14021607100) 10<br />

02-07-02305 Knifes for rotatory microtome, for Paraffin and Frozen Sections. 16 cm. Profile C, both sides plane.<br />

#(32561)<br />

10<br />

02-07-02306 Cuvette, optical glass, 10 mm. Pathlength. Set of 2 pcs. #(14451) 50<br />

02-07-02307 Cuvette, Silica, 10 mm pathlength, set of 2 pcs. #(14452) 100<br />