Profi les - base profi les Quick-Line Standard-N<br />

Article number Standard-N as 6 m bar: GPV-02-0001-57; 02-0001-57; 02-0001-57 Article number Standard-N as custom cut: GPV- GPV-02-0001-58<br />

02-0001-58<br />

6 m bar<br />

(alternative: custom cut)<br />

40 mm<br />

40 40 mm mm<br />

Quick-Line base profi le Standard-N<br />

Material: aluminium EN AW-6063 AW-6063 T66<br />

Span widths (note: construction project structural analysis<br />

must be carried out on-site. Further values on request.)<br />

Wind = 0,65 kN/m² (building height to 10 m)<br />

sk = 0,65 sk = 0,85 sk = 1,10 sk = 1,65 sk = 2,00 sk = 3,10<br />

1,75 m 1,65 m 1,55 m 1,40 m 1,35 m 1,10 m<br />

Wind = 0,80 kN/m² (building height 10 - 18 m)<br />

sk = 0,65 sk = 0,85 sk = 1,10 sk = 1,65 sk = 2,00 sk = 3,10<br />

1,75 m 1,65 m 1,55 m 1,40 m 1,35 m 1,10 m<br />

Wind = 1,30 kN/m² (building height 18 - 25 m)<br />

sk = 0,65 sk = 0,85 sk = 1,10 sk = 1,65 sk = 2,00 sk = 3,10<br />

1,70 m 1,60 m 1,50 m 1,35 m 1,30 m 1,10 m<br />

The bases of calculation: framed modules, 10° roof tilt angle,<br />

load width (clearance of supports / module width)