Accurate Exhaust Gas Temperature Reading - Donaldson Company ...
Accurate Exhaust Gas Temperature Reading - Donaldson Company ...
Accurate Exhaust Gas Temperature Reading - Donaldson Company ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Enhanced LNF and LXF Muffler maintenance<br />
Upgraded Monitoring System and Technician Tool<br />
Emissions Device Monitor (EDM) Emissions Device Monitor - Item No. X007813<br />
The <strong>Donaldson</strong> EDM is a key component of <strong>Donaldson</strong><br />
DPF systems as it records and monitors device<br />
operating conditions. <strong>Temperature</strong> and backpressure<br />
readings are continuously recorded to aid in<br />
analyzing vehicle operating trends and to support<br />
troubleshooting. The EDM sends alerts to the vehicle<br />
operator via the In-Cab Display when abnormal or<br />
undesirable operating conditions are detected.<br />
An EDM Kit is included<br />
with every LNF and LXF<br />
Muffler Kit.<br />
Sensor Harness<br />
Stainless Steel Braided Hose with<br />
Threaded Couplings<br />
50 ft. Sensor Harness<br />
(ideal for rear engine vehicles)<br />
Part No. P231739<br />
50 ft. Display Extension Harness<br />
(ideal when SECM is mounted in rear of vehicle)<br />
Part No. P236736<br />
Small Electronic Control<br />
Module (SECM)<br />
In-Cab Lighted<br />
Display<br />
Optional Parts<br />
(sold separately)<br />
50 ft. Dual Temp Sensor Harness<br />
(ideal for "dual temp" rear engine vehicles)<br />
Part No. P236776<br />
4 ft. Temp Sensor Extension Harness<br />
(ideal when the temperature sensor needs to be<br />
mounted more than 4 ft from pressure sensor)<br />
Part No. P236497<br />
The upgraded monitor system includes the following:<br />
• Enhanced In-Cab Display<br />
• Removable memory module that holds up to 500<br />
hours of data and faults to support troubleshooting<br />
• DPF temperature monitoring<br />
• Convenient push button fault resetting with the<br />
DRT (sold separately)<br />
• Optional voltage converter 24V to 12V<br />
• Optional technician tools<br />
Installation, Operation<br />
and Maintenance<br />
Manual<br />
Main Harness for<br />
SECM<br />
Pressure Transducer and<br />
<strong>Temperature</strong> Sensor on Mounting<br />
Bracket<br />
24-12V DC Converter<br />
Part No. P232038<br />
Technician<br />
Service Tools<br />
(sold separately)<br />
Diagnostic Reset Tool (DRT)<br />
Part No. P231740<br />
Service Tool Link-up Cable<br />
Part No. X007999<br />
Diagnostic Reset Tool &<br />
Link-up Cable<br />
Part No. X009649<br />
<strong>Donaldson</strong> LXF & LNF Mufflers 5