12.01.2013 Views

Sampling Device CSD 30

Sampling Device CSD 30

Sampling Device CSD 30

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Sampling</strong> <strong>Device</strong><br />

Continous <strong>Sampling</strong> <strong>Device</strong><br />

<strong>30</strong> Minutes<br />

ecoma GmbH<br />

Postfach 70 09 · 24170 Kiel<br />

Germany<br />

www.ecoma.de · info@ecoma.de<br />

t 0049 4<strong>30</strong>2-96699-0<br />

f 0049 4<strong>30</strong>2-96699-7


<strong>Sampling</strong> <strong>Device</strong> <strong>CSD</strong> <strong>30</strong><br />

Continuous <strong>Sampling</strong> <strong>Device</strong> – <strong>30</strong> Minutes<br />

1. Range of Application<br />

This sampling device is meant for continuous olfactometrical sampling.<br />

This sampling procedure is the mandatory regulation standard in Germany<br />

for measurements ordered by authorities or governmental agencies.<br />

2. Product Description<br />

The continuous sampling device consists of a vacuum container the interior<br />

of which is exhausted by an integrated compressor. The location of the<br />

sampling point and the sampling device are connected by a probe. Exhausting<br />

the interior of the sampling device causes the inside sample bag to fill<br />

with sample air via the probe. There is a calibrated nozzle within the<br />

control unit of the sampling device. The volumetric flow and therefore the<br />

filling time of the bag are controlled by the choice of the nozzles diameter<br />

and the applied pressure difference. The sampling is independent from the<br />

pressure conditions at the sampling point within a range of 150 mbar<br />

(vacuum) pressure.<br />

By use of the standard nozzle the filling of a 10l bag takes <strong>30</strong> minutes.<br />

The final break occurs automatically by a switching probe if the bag is full.<br />

Furthermore it is possible to switch off the device earlier by a countdown<br />

timer.<br />

The parts containing the sample are made of PTFE and stainless steel. They<br />

satisfy the material requirements of DIN EN 13725:2003(D). For optical<br />

control the cylinder is made of transparent PVC.<br />

The continuous sampling device is stable, robust, light and manageable.<br />

The sampling does not require current supply because the sampling device<br />

runs by storage batteries.<br />

Date May 2007 1/2


<strong>Sampling</strong> <strong>Device</strong> <strong>CSD</strong> <strong>30</strong><br />

4. Technical data<br />

Length: 700 mm<br />

Width: 190 mm<br />

Height: 260 mm<br />

Weight: 4,8 kg<br />

<strong>Sampling</strong> volume (bag size): 10 l<br />

Filling time: 5 – <strong>30</strong> minutes<br />

Suction pressure: 250 mbar<br />

Akku NiCd: 6V 5Ah<br />

Subject to change without notice<br />

Illustration may look similar<br />

3. Delivery Volume / Accessories<br />

Delivery Volume:<br />

- calibrated nozzle for <strong>30</strong>-minutes sampling<br />

- packing case<br />

- battery charger<br />

- PTFE flexible probe tube 2 m<br />

- countdown timer<br />

Accessories (not included in delivery volume):<br />

- stainless steel probe<br />

- calibrated nozzle for different volumetric flows<br />

(i.e. filling times)<br />

- sample bags 10l<br />

Date May 2007 2/2