stray capacitance, which mitigates the need for on-chip<br />

circuitry. (With silicon wafers, bond pads are isolated from<br />

the conducting substrates by thin dielectric layers so that<br />

high stray capacitance limits performance. With on-chip<br />

circuits, bond pads and stray capacitance are avoided.)<br />

Sense<br />

Plate<br />

Torsion<br />

Beam<br />

Sense<br />

Electrode<br />

Base Beam Anchor<br />

(a)<br />

SPO SPO<br />

Drive<br />

Beam<br />

Proof<br />

Mass<br />

Anchor Base Beam<br />

LM LS MPO<br />

RS RM<br />

Figure 1. The <strong>Draper</strong>/Honeywell TFG mechanism. In 1(b)<br />

and 1(c), silver is metal, diagonal lines indicate<br />

silicon attached to glass, and white indicates<br />

suspended silicon. Electrical contact pads are<br />

right motor drive (RM), right sense electrode<br />

(RS), motor pickoff (MPO), left sense electrode<br />

(LS), left motor drive (LM), and sense pick off<br />

(SPO).<br />

On either side of each proof mass are interdigitated<br />

combs. [33] The outer combs (left and right motor in Figure<br />

1) are used for electrostatically driving the proof masses<br />

antiparallel to the substrate in the x direction. The inner<br />

combs (motor pickoff in Figure 1) sense the drive motion<br />

and are typically biased to 5 Vdc through an op amp that<br />

senses charge traversing the comb gap. As described in “The<br />

Fundamental Dynamics of Oscillating Coriolis Sensors”<br />

44 Error Sources in In-Plane Silicon Tuning-Fork MEMS Gyroscopes<br />

(b)<br />

Motor Pick Off<br />

Substrate<br />

W I Input Rate<br />

(c)<br />

y<br />

x<br />

Mass Motor<br />

Sense Electrode<br />

Proof<br />

Mass<br />

section, rotation about the in-plane z-axis induces Coriolis<br />

acceleration, which deflects the proof masses in opposite<br />

directions perpendicular to the substrate. Beneath the<br />

plates are deposited metal electrodes that are excited with<br />

dc voltages of opposite polarities. The right sense plate (RS<br />

in Figure 1) is typically excited with 5 V and the left sense<br />

plate (LS) with -5 V. Differential proof mass motion induces<br />

electrical currents in the structure that flow through the<br />

suspensions and sense pickoff (SPO, Figure 1) into a<br />

preamplifier whose input contains the input angular rate<br />

modulated by the drive frequency.<br />

With drive resonant frequencies from 10 to 20 kHz, these<br />

gyroscopes are relatively stiff with suspension stiffnesses<br />

greater than 100 N/m. With 3-µm gaps, mechanical spring<br />

force of 300 µN is available to overcome sticking; nevertheless,<br />

care in etching and release, in electronic excitation,<br />

and mechanical handling is required.<br />

As detailed below, the challenge is to obtain excellent<br />

performance in a device where the sensitivity to angular<br />

rate is small. Obstacles include manufacturing tolerances<br />

and the relatively large magnitudes of non-Coriolis forces<br />

and electrical drive and excitation signals.<br />

Mode Ordering<br />

A first challenge is designing the angular rate sensor’s<br />

dynamic eigenfrequencies. If one considers the TFG proof<br />

masses (Figure 1) rigid and the suspension beams without<br />

mass, 3 rotations and 3 translations times 2 masses imply at<br />

least 12 dynamic modes. For advanced designs, proof mass<br />

compliance and suspension modes add further considerations.<br />

The TFG is designed so that the lowest frequency<br />

modes are generally: 1) drive or tuning fork, 2) translation,<br />

3) sense, and 4) out-of-plane. In the tuning-fork mode, the<br />

proof masses move antiparallel to the substrate. One usually<br />

attempts to excite this mode through the electrostatic motor<br />

drive. Similar proof mass amplitudes are the design goal.<br />

The drive frequency is designed for 10-20 kHz to reduce<br />

vibration and acoustic effects. For the translation mode,<br />

the proof masses move parallel to the substrate. Because<br />

the drive combs are controlled to apply forces in opposite<br />

directions, translation should not be excited by electrostatic<br />

drive; however, translation is excited by linear acceleration.<br />

To ensure tuning-fork operation despite beam width tolerances,<br />

the in-plane translation frequency is usually set 10-<br />

15% or more away from the drive frequency.<br />

The sense mode has the two proof masses moving away<br />

or toward the substrate in opposite directions. This could<br />

also be a rotation about their common center. For good<br />

gain, the sense eigenfrequency is set 5-15% away from the<br />

drive. While higher gain can be achieved at smaller separation,<br />

small variations in the resonant frequencies result in<br />

larger fractional changes of scale factor. When the out-ofplane<br />

mode is excited, the two proof masses move together<br />

perpendicular to the substrate. It is important that the lowest<br />

modes do not fall close to one another and that higher order<br />

modes are not integral multiples of the basic four.