Slimdrive SL NT,<br />

Slimdrive SL, ECdrive,<br />

Powerdrive PL<br />

Automatic<br />

sliding door systems<br />

Automatic sliding door systems<br />

ACCESSORIES<br />

82<br />

Operating automatic sliding doors<br />

GEZE o� ers programme switches for a wide range of individual requirements. The switches are suitable for universal use – for surface-mounted<br />

or � ush-mounted installati<strong>on</strong>. The following switch types are available:<br />

Display programme switch (DPS)<br />

Key programme switch (TPS)<br />

Mechanical programme switch (MPS)<br />

The following operating modes can be set:<br />

“Permanently open”<br />

The door moves to the OPEN positi<strong>on</strong> <str<strong>on</strong>g>and</str<strong>on</strong>g> remains open. Movement detector or opening butt<strong>on</strong> are deactivated.<br />

“Night”<br />

The movement detectors are switched inactive, the door closes.<br />

Opti<strong>on</strong>: The door leaves are locked electrically to prevent forced opening.<br />

“Shop closing” (<strong>on</strong>e-way)<br />

The door <strong>on</strong>ly opens <str<strong>on</strong>g>and</str<strong>on</strong>g> closes when some<strong>on</strong>e goes out from the inside.<br />

The movement detector outside is switched inactive, the <strong>on</strong>e inside is switched active.<br />

“Automatic”<br />

The door opens as so<strong>on</strong> as it is actuated via the movement detector or keys, <str<strong>on</strong>g>and</str<strong>on</strong>g> closes after a certain individually adjustable time. Safety sensors<br />

protect the leaves’ travel path. If there is some<strong>on</strong>e in the door opening, the door will not close.<br />

“Reduced opening width”<br />

The settings determined in teach mode are activated or deactivated.<br />

“OFF” (<strong>on</strong>ly with TPS <str<strong>on</strong>g>and</str<strong>on</strong>g> MPS)<br />

Drive <str<strong>on</strong>g>and</str<strong>on</strong>g> sensors are switched o� , the door leaves can be moved manually.<br />

Key switch<br />

The programme switch can be disabled using a key switch.<br />

Securing the programme switches<br />

Automatic sliding doors in emergency exit routes must be secured against operati<strong>on</strong> by unauthorised people. The mechanical programme<br />

switch (MPS) is also available in a lockable versi<strong>on</strong>. The display programme switch (DPS) <str<strong>on</strong>g>and</str<strong>on</strong>g> key programme switch (TPS) can be combined<br />

with a key switch. Alternatively, these programme switches can be secured using a code.<br />

Display programme switch (DPS) Key programme switch (TPS) Mechanical programme switch (MPS)<br />