Backup Systems<br />

<strong>SUNNY</strong> <strong>BACKUP</strong> <strong>5000</strong><br />

<strong>Errata</strong> <strong>Sheet</strong><br />

This document applies to the device type SBU <strong>5000</strong> with firmware version 7.1 and higher.<br />

This document replaces the sections from the technical description of the Sunny Backup <strong>5000</strong> listed<br />

in the following table:<br />

Sections in the technical description of the<br />

Sunny Backup <strong>5000</strong><br />

Section in<br />

errata sheet<br />

In errata sheet<br />

from page<br />

Section 19.1 "Display Values" 19.1 3<br />

Section 19.2 "Adjustable System Parameters" 19.2 14<br />

Section 19.3 "Diagnostics" 19.3 38<br />

Section 19.4 "Events, Warnings, and Errors (History)" 19.4 43<br />

Section 19.5 "Functions in Operation" 19.5 43<br />

Section 20.6 "Events" 20.1 46<br />

Section 20.8 "Warnings and Error Messages" 20.2 50<br />

ParaSBU50-E-TB-en-11 | DBEN-SBU50_PARA | Version 1.1 EN


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

19 Parameter Lists<br />

The following diagram provides an overview of the menu structure.<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 2/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

All menu items that can only be displayed or changed after entering the installer password are<br />

shaded in gray in the following tables.<br />

• Observe the information in Section 19 of the technical description of the Sunny Backup <strong>5000</strong>,<br />

"Parameter Lists".<br />

19.1 Display Values<br />

110# Inverter Meters<br />

Menu no. Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Description<br />

111# Inverter Total Meters<br />

111 01 TotInvPwrAt kW Total active power of inverter<br />

(cluster)<br />

111 02 TotInvCur A Total inverter current (cluster)<br />

111 03 TotInvPwrRt kVAr Total reactive power of inverter<br />

(cluster)<br />

112# Inverter Device Meters<br />

112 01 InvOpStt<br />

Operating state:<br />

Standby = Standby<br />

Run<br />

= Operation/emergency charge<br />

Error<br />

= Error<br />

Startup<br />

= Transfer from standby →<br />

KickOff operation<br />

= Shutdown of Sunny Boys due to<br />

frequency increase<br />

112 02 InvPwrAt kW Active power of inverter<br />

112 03 InvVtg V Voltage at the inverter<br />

112 04 InvCur A Inverter current<br />

112 05 InvFrq Hz Frequency at the inverter<br />

112 06 InvPwrRt kVAr Reactive power at the inverter<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 3/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu no. Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Description<br />

112 07 Rly1Stt Off, On State of relay 1<br />

112 08 Rly2Stt Off, On State of relay 2<br />

113# Inverter Slave1 Meters<br />

113 01 InvOpSttSlv1<br />

Operating state:<br />

Standby = Standby<br />

Run<br />

= Operation/emergency charge<br />

Error<br />

= Error<br />

Startup<br />

= Transfer from standby →<br />

KickOff operation<br />

= Shutdown of Sunny Boys due to<br />

frequency increase<br />

113 02 InvPwrAtSlv1 kW Active power at inverter slave 1<br />

113 03 InvVtgSlv1 V Voltage at inverter slave 1<br />

113 04 InvCurSlv1 A Inverter current at slave 1<br />

113 05 InvPwrRtSlv1 kVAr Reactive power at inverter slave 1<br />

113 06 Rly1SttSlv1 Off, On State of relay 1, slave 1<br />

113 07 Rly2SttSlv1 Off, On State of relay 2, slave 1<br />

114# Inverter Slave2 Meters<br />

114 01 InvOpSttSlv2<br />

Operating state:<br />

Standby = Standby<br />

Run<br />

= Operation/emergency charge<br />

Error<br />

= Error<br />

Startup<br />

= Transfer from standby →<br />

KickOff operation<br />

= Shutdown of Sunny Boys due to<br />

frequency increase<br />

114 02 InvPwrAtSlv2 kW Active power at inverter slave 2<br />

114 03 InvVtgSlv2 V Voltage at inverter slave 2<br />

114 04 InvCurSlv2 A Inverter current at slave 2<br />

114 05 InvPwrRtSlv2 kVAr Reactive power at inverter slave 2<br />

114 06 Rly1SttSlv2 Off, On State of relay 1, slave 2<br />

114 07 Rly2SttSlv2 Off, On State of relay 2, slave 2<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 4/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

120# Battery Meters<br />

Menu no. Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Description<br />

120 01 BatSoc % Battery state of charge (SOC)<br />

120 02 BatVtg V Battery voltage<br />

120 03 BatChrgVtg V Charging voltage target value<br />

120 04 AptTmRmg hh:mm:ss Remaining absorption time<br />

(hh:mm:ss)<br />

120 05 BatChrgOp<br />

Active charging process:<br />

Boost<br />

= Boost charge<br />

Full<br />

= Full charge<br />

Equalize = Equalization charge<br />

Float<br />

= Float charge<br />

Silent<br />

= Silent mode<br />

120 06 TotBatCur A Total battery current of cluster<br />

120 07 BatTmp degC Battery temperature<br />

120 08 RmgTmFul d Remaining time until next full<br />

charge<br />

120 09 RmgTmEqu d Remaining time until next<br />

equalization charge<br />

120 10 AptPhs Off, On Absorption phase is active<br />

120 11 BatSocErr % Estimated error of the state of<br />

charge<br />

120 12 BatCpyThrpCnt ‒ Nominal capacity cycle of the<br />

battery<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 5/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

130# Backup Meters<br />

Menu no. Parameter<br />

no.<br />

131# Total Meters<br />

Parameter<br />

name<br />

Range/unit Description<br />

131 01 TotExtPwrAt kW Total active power of external<br />

source<br />

131 02 TotExtCur A Total current of external source<br />

131 03 TotExtPwrRt kVAr Reactive power of external source<br />

131 04 TotLodPwr kW Average active power of the loads<br />

(cluster)<br />

131 05 TotMccLodPwr kW Average active power of the loads<br />

(multicluster)<br />

132# External Total<br />

132 01 GdRmgTm hh:mm:ss Remaining time of GdValTm<br />

parameter (valid grid time)<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 6/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu no. Parameter Parameter Range/unit Description<br />

no.<br />

133# Generator State<br />

name<br />

133 01 GnDmdSrc<br />

Source for generator request:<br />

None<br />

= No request<br />

Bat<br />

= Dependent on battery state of<br />

Lod<br />

charge<br />

Tim<br />

= Load dependent<br />

Run1h<br />

= Time controlled<br />

Start<br />

= For 1 hour<br />

ExtSrcReq = Manually started<br />

= External source request<br />

133 02 GnStt<br />

Generator state:<br />

Off<br />

= Switched off<br />

Ready<br />

= Waiting for request (ready)<br />

Warm<br />

= Warming up<br />

Connect = Connecting<br />

Run<br />

= Operation<br />

Retry<br />

= Restarting<br />

Disconnect = Isolation<br />

Cool<br />

= Cooling down<br />

Lock<br />

= Locked after operation<br />

Fail<br />

= Error<br />

FailLock = Locked after error<br />

133 03 GnRmgTm hh:mm:ss Remaining run time of generator<br />

(minimum run time)<br />

133 04 GnRnStt Off<br />

Status of generator feedback on<br />

On<br />

master (Dig-In)<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 7/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu no. Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Description<br />

134# Device Meters<br />

134 01 ExtPwrAt kW Active power of external source<br />

134 02 ExtVtg V Voltage of external source<br />

134 03 ExtCur A Current of external source<br />

134 04 ExtFrq Hz Frequency of external source<br />

134 05 ExtPwrRt kVAr Reactive power of external source<br />

135# Backup Slave1 Meters<br />

135 01 ExtPwrAtSlv1 kW Active power of external source on<br />

slave 1<br />

135 02 ExtVtgSlv1 V Voltage of external source on<br />

slave 1<br />

135 03 ExtCurSlv1 A Current of external source on<br />

slave 2<br />

135 04 ExtPwrRtSlv1 kVAr Reactive power of external source<br />

on slave 2<br />

136# Backup Slave2 Meters<br />

136 01 ExtPwrAtSlv2 kW Active power of external source on<br />

slave 2<br />

136 02 ExtVtgSlv2 V Voltage of external source on<br />

slave 2<br />

136 03 ExtCurSlv2 A Current of external source on<br />

slave 2<br />

136 04 ExtPwrRtSlv2 kVAr Reactive power of external source<br />

on slave 2<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 8/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu no. Parameter<br />

no.<br />

138# Chp Meters<br />

138 01 ChpStt Idle<br />

Run<br />

Lock<br />

140# Charge Controller<br />

State of CHP plant<br />

138 02 ChpPwrAt kW Power of CHP plant<br />

138 03 ChpRmgTm hh:mm:ss Remaining run time of CHP plant<br />

(minimum run time)<br />

138 04 ChpStrRmgTm hh:mm:ss Remaining run time of CHP plant<br />

power request<br />

Menu no. Parameter<br />

no.<br />

141# SIC50 Total<br />

Parameter<br />

name<br />

Parameter<br />

name<br />

Range/unit Description<br />

Range/unit Description<br />

141 01 TotSicEgyCntIn kWh Total energy of all Sunny Island<br />

Chargers<br />

141 02 TotSicDyEgyCntIn kWh Total daily energy of all<br />

Sunny Island Chargers<br />

141 03 TotSicPvPwr W Total PV power of all Sunny Island<br />

Chargers<br />

141 04 TotSicBatCur A Total battery current of all<br />

Sunny Island Chargers<br />

142# SIC50 1<br />

142 01 Sic1EgyCntIn kWh Energy of the first<br />

Sunny Island Charger<br />

142 02 Sic1TdyEgyCntIn kWh Daily energy of the first<br />

Sunny Island Charger<br />

142 03 Sic1PvPwr W PV power of the first<br />

Sunny Island Charger<br />

142 04 Sic1PvVtg V PV voltage of the first<br />

Sunny Island Charger<br />

142 05 Sic1BatVtg V Battery voltage of the first<br />

Sunny Island Charger<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 9/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu no. Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Description<br />

142 06 Sic1BatCur A Battery current of the first<br />

Sunny Island Charger<br />

142 07 Sic1HsTmp degC Heat sink temperature of the first<br />

Sunny Island Charger<br />

142 08 Sic1SWVers ‒ Software version of the first<br />

Sunny Island Charger<br />

143# SIC50 2<br />

143 01 Sic2EgyCntIn kWh Energy of the second<br />

Sunny Island Charger<br />

143 02 Sic2TdyEgyCntIn kWh Daily energy of the second<br />

Sunny Island Charger<br />

143 03 Sic2PvPwr W PV power of the second<br />

Sunny Island Charger<br />

143 04 Sic2PvVtg V PV voltage of the second<br />

Sunny Island Charger<br />

143 05 Sic2BatVtg V Battery voltage of the second<br />

Sunny Island Charger<br />

143 06 Sic2BatCur A Battery current of the second<br />

Sunny Island Charger<br />

143 07 Sic2HsTmp degC Heat sink temperature of the<br />

second Sunny Island Charger<br />

143 08 Sic2SWVers ‒ Software version of the second<br />

Sunny Island Charger<br />

144# SIC50 3<br />

144 01 Sic3EgyCntIn kWh Energy of the third<br />

Sunny Island Charger<br />

144 02 Sic3TdyEgyCntIn kWh Daily energy of the third<br />

Sunny Island Charger<br />

144 03 Sic3PvPwr W PV power of the third<br />

Sunny Island Charger<br />

144 04 Sic3PvVtg V PV voltage of the third<br />

Sunny Island Charger<br />

144 05 Sic3BatVtg V Battery voltage of the third<br />

Sunny Island Charger<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 10/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu no. Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Description<br />

144 06 Sic3BatCur A Battery current of the third<br />

Sunny Island Charger<br />

144 07 Sic3HsTmp degC Heat sink temperature of the third<br />

Sunny Island Charger<br />

144 08 Sic3SWVers ‒ Software version of the third<br />

Sunny Island Charger<br />

145# SIC50 4<br />

145 01 Sic4EgyCntIn kWh Energy of the fourth<br />

Sunny Island Charger<br />

145 02 Sic4TdyEgyCntIn kWh Daily energy of the fourth<br />

Sunny Island Charger<br />

145 03 Sic4PvPwr W PV power of the fourth<br />

Sunny Island Charger<br />

145 04 Sic4PvVtg V PV voltage of the fourth<br />

Sunny Island Charger<br />

145 05 Sic4BatVtg V Battery voltage of the fourth<br />

Sunny Island Charger<br />

145 06 Sic4BatCur A Battery current of the fourth<br />

Sunny Island Charger<br />

145 07 Sic4HsTmp degC Heat sink temperature of the fourth<br />

Sunny Island Charger<br />

145 08 Sic4SWVers ‒ Software version of the fourth<br />

Sunny Island Charger<br />

For menu 150# Compact Meters, see the technical description of the Sunny Backup <strong>5000</strong>, Section<br />

10.4 "Compact Meters".<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 11/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

160# Meter SlfCsmp<br />

Menu no. Parameter<br />

no.<br />

161#Meter Power<br />

Parameter<br />

name<br />

Range/unit Description<br />

161 01 TotPvPwrAt kW Total PV power<br />

161 02 TotLodPwrAt kW Total load capacity<br />

161 03 SlfCsmpPwrAt kW Self-consumption<br />

161 04 SlfCsmpIncPwr kW Increased self-consumption<br />

161 05 GdCsmpPwrAt kW Power drawn from the electricity<br />

grid<br />

161 06 GdFeedPwrAt kW Feed-in capacity into the electricity<br />

grid<br />

162# Meter Energy<br />

162 01 PvEgyMtr kWh Meter reading, PV production<br />

meter<br />

162 02 TotLodEgyCnt kWh Total consumption<br />

162 03 SlfCsmpIncTdy kWh Today's increased selfconsumption<br />

162 04 SlfCsmpIncEgy kWh Total increased self-consumption<br />

162 05 SlfCsmpEgy kWh Total self-consumption<br />

162 06 GdCsmpEgyMtr kWh Meter reading, purchased<br />

electricity<br />

162 07 GdCsmpEgyTdy kWh Today's purchased electricity<br />

162 08 GdFeedEgyMtr kWh Meter reading, grid feed-in<br />

162 09 GdFeedEgyTdy kWh Today's grid feed-in<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 12/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu no. Parameter Parameter Range/unit Description<br />

no.<br />

163# Meter State<br />

name<br />

163 01 PvGdConStt<br />

Grid into which the PV plant is to<br />

feed<br />

Grid<br />

= Electricity grid<br />

Backup = Stand-alone grid*<br />

Off<br />

= No feed-in<br />

163 02 LodGdConStt<br />

Grid supplying the loads<br />

Grid<br />

= Electricity grid**<br />

Backup = Stand-alone grid*<br />

Off<br />

= No supply<br />

GridBypass = Electricity grid***<br />

163 03 BatMntStt Status of the full or equalization<br />

charge<br />

On = Full or equalization charge is<br />

active, receives energy from the<br />

electricity grid<br />

Wait = If sufficient PV energy is<br />

available, full or equalization<br />

charge is active<br />

and<br />

if full or equalization charge with<br />

PV energy has not finished after<br />

24 h, "163.03 BatMntStt" switches<br />

to ON<br />

Off = No full or equalization charge is<br />

active<br />

* The Sunny Backup forms a stand-alone grid.<br />

** The Sunny Backup is connected.<br />

*** The Sunny Backup is not connected.<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 13/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

19.2 Adjustable System Parameters<br />

Parameters with the designation (Stby)<br />

Parameters with the designation (Stby) can be changed immediately after pressing the [ENTER]<br />

key. It may not be possible to correct incorrectly configured parameters quickly enough to prevent<br />

these causing damage to your plant.<br />

• Parameters with the designation (Stby) are to be changed only when the<br />

Sunny Backup <strong>5000</strong> is in standby mode.<br />

Configuring parameters via a computer or laptop<br />

All parameters can be configured using a connected computer or laptop.<br />

Therefore, you require a connected Sunny WebBox, a Sunny Boy Control, or the software<br />

program Sunny Data Control (see Section 6.5 "Interface for external communication" in the<br />

technical description of the Sunny Backup <strong>5000</strong>).<br />

210# Inverter Settings<br />

Menu no. Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/<br />

unit<br />

Value Description<br />

210 01 InvVtgNom V 230 Nominal voltage of inverter<br />

210 02 InvChrgCurMax A 21.7 Maximum AC charging current<br />

210 03 InvFrqNom Hz 50 Nominal frequency of inverter<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 14/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

220# Battery Settings<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

221# Battery Property<br />

221 01 BatTyp<br />

Range/unit Default<br />

value<br />

VRLA<br />

FLA<br />

NiCd<br />

LiIon<br />

Other<br />

Description<br />

VRLA Battery type:<br />

= Valve Regulated Lead<br />

Acid<br />

= Flooded Lead Acid<br />

= Nickel cadmium<br />

= Lithium-ion<br />

= Other battery types<br />

Can only be changed in<br />

QCG<br />

221 02 BatCpyNom Ah 100 Battery capacity (C10)<br />

Can only be changed in<br />

QCG<br />

221 03 BatVtgNom V 48 Nominal voltage of<br />

battery<br />

48 = VRLA<br />

48 = FLA<br />

45.6 = NiCd<br />

48 = LiIon<br />

48 = Other<br />

221 04 BatTmpMax degC 40 Maximum battery<br />

temperature<br />

221 05 BatTmpStr degC 35 Battery restart<br />

temperature following<br />

stop due to<br />

overtemperature<br />

221 07 BatFanTmpStr degC 40°C Start temperature for the<br />

"BatFan" function<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 15/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

222# Battery Charge Mode<br />

Range/unit Default<br />

value<br />

Description<br />

222 01 BatChrgCurMax A 1,200 Battery charging current<br />

limit (depending on<br />

nominal capacity of<br />

battery), 60% of the<br />

nominal capacity of the<br />

battery (221.02)<br />

222 02 AptTmBoost min 120 Boost charge absorption<br />

time<br />

120 = VRLA<br />

90 = FLA<br />

300 = NiCd<br />

Depending on the setting<br />

in QCG<br />

222 03 AptTmFul h 5 Absorption time for full<br />

charge<br />

5 = VRLA<br />

5 = FLA<br />

7 = NiCd<br />

Depending on the setting<br />

in QCG<br />

222 04 AptTmEqu h 10 Absorption time for<br />

equalization charge<br />

10 = VRLA<br />

10 = FLA<br />

10 = NiCd<br />

Depending on the setting<br />

in QCG<br />

222 05 CycTmFul d 14 Full charge cycle time<br />

222 06 CycTmEqu d 180 Equalization charge cycle<br />

time<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 16/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Default<br />

value<br />

Description<br />

222 07 ChrgVtgBoost V 2.4 Cell voltage target value<br />

for boost charge<br />

2.4 = VRLA<br />

2.55 = FLA<br />

1.65 = NiCd<br />

Depending on the setting<br />

in QCG<br />

222 08 ChrgVtgFul V 2.4 Cell voltage target value<br />

for full charge<br />

2.4 = VRLA<br />

2.5 = FLA<br />

1.65 = NiCd<br />

Depending on the setting<br />

in QCG<br />

222 09 ChrgVtgEqu V 2.4 Cell voltage target value<br />

for equalization charge<br />

2.4 = VRLA<br />

2.5 = FLA<br />

1.65 = NiCd<br />

Depending on the setting<br />

in QCG<br />

222 10 ChrgVtgFlo V 2.25 Cell voltage target value<br />

for float charge<br />

2.25 = VRLA<br />

2.25 = FLA<br />

1.55 = NiCd<br />

Depending on the setting<br />

in QCG<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 17/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Default<br />

value<br />

Description<br />

222 11 BatTmpCps mV/degC 4.0 Battery temperature<br />

compensation<br />

4.0 = VRLA<br />

4.0 = FLA<br />

0.0 = NiCd<br />

Depending on the setting<br />

in QCG<br />

222 12 AutoEquChrgEna Disable Enable Enable automatic<br />

Enable<br />

equalization charge<br />

223# Battery Protect Mode<br />

223 01 BatPro1TmStr hh:mm:ss 22:00:00 Time for starting battery<br />

care level 1<br />

223 02 BatPro1TmStp hh:mm:ss 06:00:00 Time for stopping battery<br />

care level 1<br />

223 03 BatPro2TmStr hh:mm:ss 17:00:00 Time for starting battery<br />

care level 2<br />

223 04 BatPro2TmStp hh:mm:ss 09:00:00 Time for stopping battery<br />

care level 2<br />

223 05 BatPro1Soc % 20 SOC limit for care level 1<br />

223 06 BatPro2Soc % 10 SOC limit for care level 2<br />

223 07 BatPro3Soc % 0 SOC limit for care level 3<br />

224# Battery Silent Mode<br />

224 01 SilentEna Disable Disable Enable silent mode on the<br />

Enable<br />

grid<br />

224 02 SilentTmFlo h 3 Max. time for float charge<br />

(Stby)<br />

until transfer to silent<br />

224 03 SilentTmMax h 12 Max. time for silent mode<br />

(Stby)<br />

until transfer to float<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 18/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

225# Battery Current Sensor<br />

225 01 BatCurSnsTyp 60 mV<br />

50 mV<br />

230# Backup Settings<br />

None Battery current sensor<br />

type<br />

225 02 BatCurGain60 A/60mV 100 External battery current<br />

sensor (60 mV type)<br />

225 03 BatCurGain50 A/50mV 100 External battery current<br />

sensor (50 mV type)<br />

225 04 BatCurAutoCal Start ‒ Automatic calibration of<br />

external battery current<br />

sensor<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Default<br />

value<br />

Parameter name Range/unit Default<br />

value<br />

Description<br />

Description<br />

231# General<br />

231 01 PvFeedTmStr hh:mm:ss 04:00:00 Start time for PV grid<br />

feed-in<br />

231 02 PvFeedTmStp hh:mm:ss 22:00:00 Stop time for PV grid<br />

feed-in<br />

231 03 ExtLkTm min 20 Lock time after reverse<br />

power or relay protection<br />

231 05 ExtSrc PvOnly GenGrid PV only<br />

Gen<br />

Generator<br />

Grid<br />

Electricity grid<br />

GenGrid<br />

Generator or electricity<br />

grid<br />

231 12 ChpEna Disable Enable CHP plant<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 19/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

232# Grid Control<br />

Parameter name Range/unit Default<br />

value<br />

232 01 GdVtgMin * V 189 Minimum line voltage<br />

232 02 GdVtgMax * V 259.5 Maximum line voltage<br />

232 03 GdCurNom A 16 Nominal line current<br />

232 04 GdFrqNom Hz 50 Nominal power<br />

frequency<br />

232 05 GdFrqMin * Hz 47.65 Minimum power<br />

frequency<br />

232 06 GdFrqMax * Hz 51.5 Maximum power<br />

frequency<br />

232 07 GdVldTm sec 30 Minimum time required<br />

for grid (voltage and<br />

frequency) to be within<br />

permissible range for<br />

connection<br />

232 08 GdMod GridCharge<br />

GridFeed<br />

GridFeed Grid interface<br />

232 09 GdRvPwr W 100 Permissible grid reverse<br />

power (active power)<br />

232 10 GdRvTm sec<br />

232 15 GdAISns* Low<br />

Medium<br />

Normal<br />

High<br />

Description<br />

Permissible time for grid<br />

reverse power<br />

5<br />

If 239.01<br />

SlfCmpIncEna is set on<br />

Disable<br />

45 If 239.01<br />

SlfCmpIncEna is set on<br />

Enable<br />

Normal Sensitivity<br />

* Safety-related parameters for grid monitoring<br />

To change safety-related parameters for grid monitoring, it is necessary to enter your personal <strong>SMA</strong> Grid Guard code.<br />

Contact <strong>SMA</strong> Service Line to obtain your individual <strong>SMA</strong> Grid Guard code.<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 20/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

232 37 GdVtgIncProEna*<br />

Parameter name Range/unit Default<br />

value<br />

Description<br />

Disable Enable Enable voltage increase<br />

Enable<br />

protection<br />

232 38 GdVtgIncPro* V 253 Threshold for voltage<br />

increase protection<br />

232 40 Country Adjusted; GER_VDE0_ Country selection<br />

Other;<br />

GER_VDE0_<br />

126_1_1;<br />

AUS_AS47<br />

77;<br />

GR_PPC;<br />

GR_INSUL<br />

AR<br />

126_1_1<br />

232 41 GdSocEna Disable Disable Enable grid request<br />

Enable<br />

based on SOC<br />

232 42 GdPwrEna Disable Disable Enable grid request<br />

Enable<br />

based on power<br />

* Safety-related parameters for grid monitoring<br />

To change safety-related parameters for grid monitoring, it is necessary to enter your personal <strong>SMA</strong> Grid Guard code.<br />

Contact <strong>SMA</strong> Service Line to obtain your individual <strong>SMA</strong> Grid Guard code.<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 21/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter name Range/unit Default<br />

value<br />

Description<br />

233# Grid Start<br />

233 01 GdSocTm1Str % 40 SOC limit for switching<br />

on the grid for time 1<br />

233 02 GdSocTm1Stp % 80 SOC limit for switching<br />

off the grid for time 1<br />

233 03 GdSocTm2Str % 40 SOC limit for switching<br />

on the grid for time 2<br />

233 04 GdSocTm2Stp % 80 SOC limit for switching<br />

off the grid for time 2<br />

233 05 GdTm1Str hh:mm:ss 00:00:00 Time 1 for grid request<br />

(begin time 1,<br />

end time 2)<br />

233 06 GdTm2Str hh:mm:ss 00:00:00 Time 2 for grid request<br />

(begin time 2,<br />

end time 1)<br />

233 07 GdPwrStr kW 4.0 Grid request connection<br />

power limit<br />

233 08 GdPwrStp kW 2.0 Grid request<br />

disconnection power<br />

limit<br />

233 09 GdStrChrgMod Off Equal Charge start when<br />

Full<br />

Equal<br />

Both<br />

connecting to the grid<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 22/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

234# Generator Control<br />

Parameter name Range/unit Default<br />

value<br />

Description<br />

234 01 GnVtgMin V 172.5 Minimum generator<br />

voltage<br />

234 02 GnVtgMax V 250 Maximum generator<br />

voltage<br />

234 03 GnCurNom A 16 Nominal generator<br />

current<br />

234 04 GnFrqNom Hz 50 Nominal generator<br />

frequency (at nominal<br />

load)<br />

234 05 GnFrqMin Hz 44.64 Minimum generator<br />

frequency<br />

234 06 GnFrqMax Hz 60 Maximum generator<br />

frequency<br />

234 07 GnStrMod Manual<br />

Autostart<br />

GenMan<br />

Autostart Generator interface<br />

234 08 GnOpTmMin min 15 Minimum run time of<br />

generator<br />

234 09 GnStpTmMin min 15 Minimum stop time of<br />

generator<br />

234 10 GnCoolTm min 5 Generator cooling-off<br />

time<br />

234 11 GnErrStpTm h 1 Generator stop time in<br />

case of generator failure<br />

234 12 GnWarmTm sec 60 Warm-up time<br />

234 13 GnRvPwr W 100 Permissible generator<br />

reverse power (active<br />

power)<br />

234 14 GnRvTm sec 30 Permissible time for<br />

reverse power/reverse<br />

current<br />

234 15 GnCtlMod Cur Cur Ext. (gen/grid) control<br />

CurFrq<br />

(current or frequency)<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 23/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu Parameter Parameter name Range/unit Default Description<br />

no. no.<br />

value<br />

234 20 GnAISns Low Normal Sensitivity of islanding<br />

Medium<br />

Normal<br />

High<br />

detection in generator<br />

operation<br />

234 41 GnCurCtlMod Droop Droop Switch for enabling the<br />

CurCtl<br />

I-Loop in generator<br />

operation<br />

235# Generator Start<br />

235 01 GnAutoEna Off On Enable generator<br />

On<br />

autostart<br />

235 02 GnAutoStr ‒ 3 Number of autostarts<br />

235 03 GnSocTm1Str % 40 SOC limit for generator<br />

(switching on for time 1)<br />

235 04 GnSocTm1Stp % 80 SOC limit for generator<br />

(switching off for time 1)<br />

235 05 GnSocTm2Str % 40 SOC limit for generator<br />

(switching on for time 2)<br />

235 06 GnSocTm2Stp % 80 SOC limit for generator<br />

(switching off for time 2)<br />

235 07 GnTm1Str hh:mm:ss 00:00:00 Time 1 for generator<br />

request (begin time 1,<br />

end time 2)<br />

235 08 GnTm2Str hh:mm:ss 00:00:00 Time 2 for generator<br />

request (begin time 2,<br />

end time 1)<br />

235 09 GnPwrEna Off Off Enable generator<br />

On<br />

request based on power<br />

235 10 GnPwrStr kW 5.5 Generator request,<br />

starting capacity<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 24/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu Parameter Parameter name Range/unit Default Description<br />

no. no.<br />

value<br />

235 11 GnPwrStp kW 5 Generator request,<br />

interrupting capacity<br />

235 12 GnPwrAvgTm sec 60 Average time for<br />

power-related generator<br />

start<br />

235 13 GnTmOpEna Disable Disable Time-controlled<br />

Enable<br />

generator operation<br />

235 14 GnTmOpStrDt dd.mm.yyyy 01.01.2010 Start date for<br />

time-controlled<br />

generator operation<br />

235 15 GnTmOpStrTm hh:mm:ss 00:00:00 Start time for<br />

time-controlled<br />

generator operation<br />

235 16 GnTmOpRnDur hh:mm:ss 00:00:00 Run time for<br />

time-controlled<br />

generator operation<br />

235 17 GnTmOpCyc Single Single Repeat cycle for<br />

Daily<br />

Weekly<br />

time-controlled<br />

generator operation<br />

235 18 GnStrChrgMod Off Both Generator start for<br />

Full<br />

Equal<br />

Both<br />

charge type<br />

235 19 GnStrDigIn Disable Disable Generator start upon<br />

Enable<br />

signal at activated<br />

digital input<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 25/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

236# CHP Control<br />

Parameter name Range/unit Default<br />

value<br />

Description<br />

236 01 ChpOpTmMin min 60 Minimum run time of<br />

CHP plant<br />

236 02 ChpStpTmMin min 10 Minimum stop time of<br />

CHP plant<br />

236 03 ChpPwrMax kW 5 Max. power of CHP<br />

plant<br />

236 04 ChpPwrMin kW 2 Min. power of CHP plant<br />

236 05 ChpFrqPwrMax Hz 51 Lower frequency limit for<br />

maximum CHP plant<br />

power<br />

236 06 ChpFrqPwrMin Hz 52 Upper frequency limit for<br />

minimum CHP plant<br />

power<br />

236 07 ChpFrqOff Hz 53 Disconnection: CHP<br />

plant in no-load<br />

operation<br />

237# CHP Start<br />

237 01 ChpSocTm1Str % 40 SOC limit for CHP plant<br />

(switching on for time 1)<br />

237 02 ChpSocTm1Stp % 80 SOC limit for CHP plant<br />

(switching off for time 1)<br />

237 03 ChpSocTm2Str % 40 SOC limit for CHP plant<br />

(switching on for time 2)<br />

237 04 ChpSocTm2Stp % 80 SOC limit for CHP plant<br />

237 05 ChpTm1Str hh:mm:ss 0 Time 1 for CHP plant<br />

request (begin time 1,<br />

end time 2)<br />

237 06 ChpTm2Str hh:mm:ss 0 Time 2 for CHP plant<br />

request (begin time 2,<br />

end time 1)<br />

237 07 ChpPwrEna Disable Enable Enable CHP plant<br />

Enable<br />

request based on power<br />

237 08 ChpPwrStr kW 4 CHP plant request,<br />

starting capacity<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 26/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter name Range/unit Default<br />

value<br />

Description<br />

237 09 ChpPwrStrDly min 5 Time delay for CHP plant<br />

power request<br />

237 10 ChpManStr Auto ‒ Automatic<br />

Start<br />

Start<br />

Stop<br />

Stop<br />

237 11 ChpAddOnTm sec 60 Time for the additional<br />

CHP plant request<br />

enabled<br />

237 12 ChpAddOffTm sec 120 Time for the additional<br />

CHP plant request<br />

disabled<br />

237 13 ChpAddSocDel % 5 Distance to the next<br />

SOC level<br />

239# Meter SelfCsmpInc<br />

239 01 SlfCsmpIncEna Disable Disable Increased<br />

Enable<br />

self-consumption<br />

239 02 SlfCsmpSOCMin % 50 Lower state of charge<br />

limit for increased<br />

self-consumption<br />

239 03 SlfCsmpStdbyMod Off Off The Sunny Backup is<br />

On<br />

disconnected if it falls<br />

below the lower state of<br />

charge limit for<br />

increased selfconsumption<br />

239 05 SlfCsmpMtrBal Disable Enable Increased<br />

Enable<br />

self-consumption via grid<br />

feed-in from the battery<br />

to the electricity grid<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 27/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

240# Relay Settings<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

241# Relay General<br />

241 01 Rly1Op Off<br />

On<br />

AutoGn<br />

AutoLodExt<br />

AutoLod1Soc<br />

AutoLod2Soc<br />

Tmr1<br />

Tmr2<br />

ExtPwrDer<br />

GnRn,ExtVfOk<br />

GdOn,Error<br />

Warn<br />

Run<br />

BatFan<br />

AcdCir<br />

MccBatFan<br />

MccAutoLod<br />

CHPreq<br />

CHPAdd<br />

SiComRemote<br />

Overload<br />

Range/unit Default value Description<br />

AutoGn Function of relay 1<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 28/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Default value Description<br />

241 02 Rly2Op Off<br />

On<br />

AutoGn<br />

AutoLodExt<br />

AutoLod1Soc<br />

AutoLod2Soc<br />

Tmr1<br />

Tmr2<br />

ExtPwrDer<br />

GnRn<br />

ExtVfOk<br />

GdOn<br />

Error<br />

Warn<br />

Run<br />

BatFan<br />

AcdCir<br />

MccBatFan<br />

MccAutoLod<br />

CHPreq<br />

CHPAdd<br />

SiComRemote<br />

Overload<br />

AutoLodExt Function of relay 2<br />

241 07 ExtPwrDerMinTm min 10 Minimum time for<br />

"ExtPwrDer"<br />

function in minutes<br />

241 08 ExtPwrDerDltVtg V 0.15 Voltage difference<br />

for "ExtPwrDer"<br />

function<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 29/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

242# Relay Load<br />

Parameter<br />

name<br />

Range/unit Default value Description<br />

242 01 Lod1SocTm1Str % 30 SOC limit for load<br />

shedding 1 start<br />

for t1<br />

242 02 Lod1SocTm1Stp % 50 SOC limit for load<br />

shedding 1 stop<br />

for t1<br />

242 03 Lod1SocTm2Str % 30 SOC limit for load<br />

shedding 1 start<br />

for t2<br />

242 04 Lod1SocTm2Stp % 50 SOC limit for load<br />

shedding 1 stop<br />

for t2<br />

242 05 Lod1Tm1Str hh:mm:ss 00:00:00 Load shed 1 time 1<br />

(begin time 1, end<br />

time 2)<br />

242 06 Lod1Tm2Str hh:mm:ss 00:00:00 Load shed 1 time 2<br />

(begin time 2, end<br />

time 1)<br />

242 07 Lod2SocTm1Str % 30 SOC limit for load<br />

shedding start<br />

for t1<br />

242 08 Lod2SocTm1Stp % 50 SOC limit for load<br />

shedding stop<br />

for t1<br />

242 09 Lod2SocTm2Str % 30 SOC limit for load<br />

shedding start for<br />

t2<br />

242 10 Lod2SocTm2Stp % 50 SOC limit for load<br />

shedding stop for<br />

t2<br />

242 11 Lod2Tm1Str hh:mm:ss 0 Load shed 2 time 1<br />

(begin time 1, end<br />

time 2)<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 30/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Default value Description<br />

242 12 Lod2Tm2Str hh:mm:ss 0 Load shed 2 time 2<br />

(begin time 2, end<br />

time 1)<br />

243# Relay Timer<br />

243 01 RlyTmr1StrDt dd.mm.yyyy 01.01.2010 Start date timer 1<br />

243 02 RlyTmr1StrTm hh:mm:ss 00:00:00 Start time for relay<br />

control timer 1<br />

243 03 RlyTmr1Dur hh:mm:ss 00:00:00 Run time for relay<br />

control timer 1<br />

243 04 RlyTmr1Cyc Single<br />

Single Repeat cycle time<br />

Daily<br />

Weekly<br />

for timer 1<br />

243 05 RlyTmr2StrDt dd.mm.yyyy 01.01.2010 Start date timer 2<br />

243 06 RlyTmr2StrTm hh:mm:ss 00:00:00 Start time for relay<br />

control timer 2<br />

243 07 RlyTmr2Dur hh:mm:ss 00:00:00 Run time for relay<br />

control timer 2<br />

243 08 RlyTmr2Cyc Single<br />

Single Repeat cycle time<br />

Daily<br />

Weekly<br />

for timer 2<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 31/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

244# Relay Slave 1<br />

Parameter<br />

name<br />

244 01 Rly1OpSlv1 Off<br />

On<br />

AutoGn<br />

AutoLodExt<br />

AutoLod1Soc<br />

AutoLod2Soc<br />

Tmr1<br />

Tmr2<br />

ExtPwrDer<br />

GnRn<br />

ExtVfOk<br />

GdOn<br />

Error<br />

Warn<br />

Run<br />

BatFan<br />

AcdCir<br />

MccBatFan<br />

MccAutoLod<br />

CHPreq<br />

CHPAdd<br />

SiComRemote<br />

Overload<br />

Range/unit Default value Description<br />

Off Function of relay 1<br />

on slave 1<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 32/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

244 02 Rly2OpSlv1 Off<br />

On<br />

AutoGn<br />

AutoLodExt<br />

AutoLod1Soc<br />

AutoLod2Soc<br />

Tmr1<br />

Tmr2<br />

ExtPwrDer<br />

GnRn<br />

ExtVfOk<br />

GdOn<br />

Error<br />

Warn<br />

Run<br />

BatFan<br />

AcdCir<br />

MccBatFan<br />

MccAutoLod<br />

CHPreq<br />

CHPAdd<br />

SiComRemote<br />

Overload<br />

Range/unit Default value Description<br />

Off Function of relay 2<br />

on slave 1<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 33/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

245# Relay Slave 2<br />

Parameter<br />

name<br />

245 01 Rly1OpSlv2 Off<br />

On<br />

AutoGn<br />

AutoLodExt<br />

AutoLod1Soc<br />

AutoLod2Soc<br />

Tmr1<br />

Tmr2<br />

ExtPwrDer<br />

GnRn<br />

ExtVfOk<br />

GdOn<br />

Error<br />

Warn<br />

Run<br />

BatFan<br />

AcdCir<br />

MccBatFan<br />

MccAutoLod<br />

CHPreq<br />

CHPAdd<br />

SiComRemote<br />

Overload<br />

Range/unit Default value Description<br />

Off Function of relay 1<br />

on slave 2<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 34/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

245 02 Rly2OpSlv2 Off<br />

On<br />

AutoGn<br />

AutoLodExt<br />

AutoLod1Soc<br />

AutoLod2Soc<br />

Tmr1<br />

Tmr2<br />

ExtPwrDer<br />

GnRn<br />

ExtVfOk<br />

GdOn<br />

Error<br />

Warn<br />

Run<br />

BatFan<br />

AcdCir<br />

MccBatFan<br />

MccAutoLod<br />

CHPreq<br />

CHPAdd<br />

SiComRemote<br />

Overload<br />

Range/unit Default value Description<br />

Off Function of relay 2<br />

on slave 2<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 35/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

250# System Settings<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

Range/unit Default value Description<br />

250 01 AutoStr 0…10 0 Autostart<br />

0 indicates: Autostart<br />

is disabled.<br />

250 02 Dt dd.mm.yyyy 01.01.2010 Date<br />

250 03 Tm hh:mm:ss 00:00:00 Time<br />

250 04 BeepEna Off<br />

On<br />

On Enable beeper<br />

250 05 ClstCfg HW<br />

Slave1<br />

Slave2<br />

1Phase1<br />

3Phase<br />

0 Cluster configuration<br />

250 06 ComBaud 1200<br />

4800<br />

9600<br />

19200<br />

38400<br />

57600<br />

115k<br />

1,200 Baud rate<br />

250 09 ComAdr ‒ ‒ Interface address<br />

250 10 SleepEna Disable<br />

Enable<br />

Enable Enable sleep mode<br />

250 11 AfraEna Disable Disable Enable Automatic<br />

Enable<br />

Frequency<br />

Synchronization<br />

250 13 SlpAtNgt Disable Enable With<br />

Enable<br />

"SleepAtNight", the<br />

slaves can be<br />

disconnected at<br />

night<br />

250 14 SlpStrTm hh:mm:ss 20:00:00 Start time for sleep<br />

mode<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 36/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

250 15 SlpStpTm hh:mm:ss 05:00:00 Stop time for sleep<br />

mode<br />

250 23 Box None<br />

AS-Box-M<br />

AS-Box-L<br />

AS-Box-XL<br />

250 24 ClstMod SingleCluster<br />

MainCluster<br />

ExtensionClst1<br />

ExtensionClst2<br />

ExtensionClst3<br />

ExtensionClstN<br />

Range/unit Default value Description<br />

‒ Internal channel for<br />

QCG (system<br />

configuration)<br />

SingleCluster Cluster type in<br />

multicluster<br />

operation<br />

250 25 ClstAdr ‒ 0 Cluster address<br />

250 28 ChrgCtlOp Auto<br />

Auto Type of DC charging<br />

DCOnly<br />

<strong>SMA</strong><br />

device<br />

250 30 RnMod RunAlways RunAlways RunMode behavior<br />

StopAlways<br />

in the event of an<br />

error<br />

For menu 280# Password Setting, see the technical description of the SBU <strong>5000</strong>.<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 37/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

19.3 Diagnosis<br />

310# Inverter Diagnosis<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter name Range/unit Description<br />

311# Total System Diag<br />

311 01 EgyCntIn kWh Energy absorbed<br />

311 02 EgyCntOut kWh Energy output<br />

311 03 EgyCntTm h Energy meter run time<br />

312# Inverter Device Diag<br />

312 01 Adr Master Device address (type)<br />

Slave1<br />

Slave2<br />

Depending on the setting in QCG<br />

312 02 FwVer ‒ OCU firmware version<br />

312 03 SN ‒ Serial number<br />

312 04 OnTmh h Operating hours<br />

312 05 ClstCfgAt 1Phase1 Set cluster configuration<br />

3Phase Depending on the setting in QCG<br />

312 06 OpStt Operating<br />

Warning<br />

Failure<br />

Operating state (device)<br />

312 07 CardStt<br />

Off<br />

SD card status message:<br />

= No SD card<br />

Operational = In operation<br />

Mount = Initialize card<br />

OutOfSpace = Insufficient memory capacity (on<br />

BadFileSys card or in main directory)<br />

Incomp = Incorrect file system<br />

Parameter = Incompatible card<br />

ParamFailed = Parameter set write access<br />

WriteLogData = Parameter set write access failed<br />

WriteLogFailed = Write log data to card<br />

= Error upon writing log data to card<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 38/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter name Range/unit Description<br />

312 08 FwVer2 ‒ DSP firmware version<br />

312 09 FwVer3 ‒ OCU boot loader<br />

312 10 FwVer4 ‒ DSP boot loader<br />

313# Inverter Slave 1 Diagnosis<br />

313 01 FwVerSlv1 ‒ OCU firmware version of slave 1<br />

313 02 SNSlv1 ‒ Serial number of slave 1<br />

313 03 OnTmhSlv1 h Operating hours of slave 1<br />

313 04 PhSlv1 L1<br />

L2<br />

L3<br />

Phase position of slave 1<br />

313 05 OpSttSlv1 Operating<br />

Warning<br />

Failure<br />

Operating state of slave 1<br />

313 06 FwVer2Slv1 ‒ DSP firmware version of slave 1<br />

313 07 FwVer3Slv1 ‒ OCU boot loader, slave 1<br />

313 08 FwVer4Slv1 ‒ DSP boot loader, slave 1<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 39/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

314# Inverter Slave 2 Diagnosis<br />

314 01 FwVerSlv2 ‒ OCU firmware version of slave 2<br />

314 02 SNSlv2 ‒ Serial number of slave 2<br />

314 03 OnTmhSlv2 h Operating hours of slave 2<br />

314 04 PhSlv2 L1<br />

L2<br />

L3<br />

Phase position of slave 2<br />

314 05 OpSttSlv2 Operating<br />

Warning<br />

Failure<br />

320# Battery Diagnosis<br />

Operating state of slave 2<br />

314 06 FwVer2Slv2 ‒ DSP firmware version of slave 2<br />

314 07 FwVer3Slv2 ‒ OCU boot loader, slave 2<br />

314 08 FwVer4Slv2 ‒ DSP boot loader, slave 2<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

no.<br />

Parameter name Range/unit Description<br />

Parameter name Range/unit Description<br />

320 01 Soh % State of health (SOH), ratio of current<br />

capacity and nominal value<br />

320 02 StatTm d Run time of statistics meter<br />

320 03 ChrgFact ‒ Charge factor<br />

320 04 BatEgyCntIn kWh Energy meter for battery charge<br />

320 05 BatEgyCntOut kWh Energy meter for battery discharge<br />

320 06 AhCntIn Ah Meter for battery charging<br />

ampere-hours<br />

320 07 AhCntOut Ah Meter for battery discharging<br />

ampere-hours<br />

320 08 BatTmpPkMin degC Minimum battery temperature<br />

320 09 BatTmpPkMax degC Maximum battery temperature<br />

320 10 EquChrgCnt ‒ Equalization charge meter<br />

320 11 FulChrgCnt ‒ Full charge meter<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 40/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter name Range/unit Description<br />

320 12 BatCurOfsErr A Current offset error of battery current<br />

320 13 OcvPointCnt ‒ Meter for passage of open-circuit<br />

voltage<br />

320 15 AhCntFul Ah/100Ah Meter for battery discharging<br />

ampere-hours since the last full charge<br />

320 16 AhCntEqu Ah/100Ah Meter for battery discharging<br />

ampere-hours since the last<br />

equalization charge<br />

320 17 BatVtgPk V Max. battery voltage encountered<br />

320 18 BatCurPkIn A Max. battery current encountered in<br />

the charging direction<br />

320 19 BatCurPkOut A Max. battery current encountered in<br />

the discharging direction<br />

320 20 SocHgm100 % Frequency distribution of state of<br />

charge, 100% > SOC >= 90%<br />

320 21 SocHgm90 % Frequency distribution of state of<br />

charge, 90% > SOC >= 80%<br />

320 22 SocHgm80 % Frequency distribution of state of<br />

charge, 80% > SOC >= 70%<br />

320 23 SocHgm70 % Frequency distribution of state of<br />

charge, 70% > SOC >= 60%<br />

320 24 SocHgm60 % Frequency distribution of state of<br />

charge, 60% > SOC >= 50%<br />

320 25 SocHgm50 % Frequency distribution of state of<br />

charge, 50% > SOC >= 40%<br />

320 26 SocHgm40 % Frequency distribution of state of<br />

charge, 40% > SOC >= 30%<br />

320 27 SocHgm30 % Frequency distribution of state of<br />

charge, 30% > SOC >= 20%<br />

320 28 SocHgm20 % Frequency distribution of state of<br />

charge, 20% > SOC >= 10%<br />

320 29 SocHgm10 % Frequency distribution of state of<br />

charge, 10% > SOC >= 0%<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 41/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

Menu<br />

no.<br />

320 30 SocHgm000 % Frequency distribution of state of<br />

charge, SOC < 0%<br />

320 31 SocVtgCal % Recalibration of state of charge only<br />

via open-circuit voltage<br />

320 32 ErrSocVtgCal % Estimated error of the voltagecalibrated<br />

state of charge<br />

320 33 SocChrgCal % Recalibration of state of charge only<br />

via full charge<br />

320 34 ErrSocChrgCal % Estimated error of the full-chargecalibrated<br />

state of charge<br />

320 35 OcvGra Ah/V Slope of open-circuit voltage<br />

characteristic curve<br />

320 36 OcvMax V Max. open-circuit voltage<br />

330# Backup Diagnosis<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

no.<br />

Parameter name Range/unit Description<br />

Parameter name Range/unit Description<br />

331# Grid Diag<br />

331 01 GdEgyCntIn kWh Energy meter for grid feed-in<br />

331 02 GdEgyCntOut kWh Energy meter for power taken from the<br />

grid<br />

331 03 GdEgyTmh h Run time of grid energy meter<br />

331 04 GdOpTmh h Operating hour meter for grid<br />

operation<br />

331 05 GdCtcCnt ‒ Meter for grid connections<br />

331 06 TotTmh h Feed-in hours<br />

332# Generator Diag<br />

332 01 GnEgyCnt kWh Generator energy meter<br />

332 02 GnEgyTm h Run time of generator energy meter<br />

332 03 GnOpTmh h Operating hours meter for generator<br />

332 04 GnStrCnt ‒ Number of generator starts<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 42/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

19.4 Events, Warnings, and Errors (History)<br />

Events, warnings, and error messages can be found in the following sections:<br />

• Events: 20.1 "Events", page 46<br />

• Warnings and error messages: 20.2 "Warnings and Error Messages", page 50<br />

19.5 Functions in Operation<br />

510# Operation Inverter<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

510 07 CntRs Inv<br />

510 08 TstClstCom Off<br />

510 09 ClstComStt Wait<br />

510 10 FrcClstUpd UpdateClst<br />

Range/unit Default<br />

value<br />

Description<br />

‒ Clear selected energy<br />

Bat<br />

Gn<br />

Gd<br />

All<br />

Sic1<br />

Sic2<br />

Sic3<br />

Sic4<br />

SicAll<br />

meters<br />

‒ Activation of<br />

Transmit<br />

communication test<br />

between the clusters<br />

OK<br />

‒ Communication test status<br />

UpdateClstBFR<br />

UpdateClstDSP<br />

‒ Manual cluster update<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 43/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

520# Operation Battery<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

520 01 ChrgSelMan Idle<br />

Start<br />

Stop<br />

530# Operation Backup<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

540# Operation Generator<br />

Name Range/unit Default<br />

value<br />

Parameter<br />

name<br />

530 02 BkupTst Stop<br />

Start<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

540 01 GnManStr Auto<br />

Stop<br />

Start<br />

Run1h<br />

Range/unit Default<br />

value<br />

Range/unit Default<br />

value<br />

Description<br />

Idle = Waiting until conditions<br />

are met<br />

= Start<br />

= Stop<br />

Description<br />

‒ Backup system test<br />

Description<br />

Stop Manual generator start<br />

540 02 GnAck Ackn ‒ Error confirmation for<br />

generator fault<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 44/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Parameter Lists<br />

550# Operation MMC Card<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

560# Operation Grid<br />

Parameter<br />

name<br />

550 01 ParaSto Set1<br />

Set2<br />

550 02 ParaLod Set1<br />

Set2<br />

Factory<br />

550 03 CardFunc ForcedWrite<br />

StoEvtHis<br />

StoFailHis<br />

StoHis<br />

550 04 DatLogEna Off<br />

On<br />

Menu<br />

no.<br />

Parameter<br />

no.<br />

Parameter<br />

name<br />

560 1 GdManStr Auto<br />

Stop<br />

Start<br />

Range/unit Default<br />

value<br />

Range/unit Default<br />

value<br />

Description<br />

‒ Save parameter settings<br />

‒ Load parameter settings<br />

‒ Functions for SD card<br />

On Activate automatic data<br />

storage<br />

Description<br />

Auto Manual grid start<br />

For menu 600# Direct Access, see the technical description of the SBU <strong>5000</strong>, Section 10.3.<br />

"Direct Access".<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 45/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

20 Troubleshooting and Problem Solving<br />

20.1 Events<br />

20.1.1 Backup Inverter Category (1xx)<br />

Display no. Description<br />

E101 Wait status<br />

E102 Startup process<br />

E103 Operation<br />

E104 Operation on the generator<br />

E105 Operation on the electricity grid<br />

E106 Feed-in grid operation<br />

E107 Sleep mode<br />

E108 Silent mode<br />

E110 Shutdown due to error<br />

E115 Emergency charge<br />

E118 Automatic start<br />

E119 Manual start<br />

E120 Manual stop<br />

E121 Start inverter disconnection in sleep mode<br />

E122 Stop inverter disconnection in sleep mode<br />

E129 Start with external generator request<br />

E130 Stop with external generator request<br />

E131 Automatic Frequency Synchronization engages<br />

E132 Automatic Frequency Synchronization stops<br />

E133 Increased self-consumption started<br />

E134 Increased self-consumption stopped<br />

E135 In increased self-consumption excluding load operation<br />

E136 In increased self-consumption, full charge or equalization charge started<br />

E137 Switch back to increased self-consumption (full charge or equalization charge<br />

finished)<br />

20.1.2 Battery Category (2xx)<br />

Display no. Description<br />

E202 (Partial) reset of battery management due to new battery<br />

E203 Battery charge algorithm switches to float charge<br />

E204 Battery charge algorithm switches to fast charge<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 46/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

Display no. Description<br />

E205 Battery charge algorithm switches to full charge<br />

E206 Operating state switches to silent mode<br />

E207 Battery charge algorithm switches to equalization charge<br />

E221 Battery protection level 1<br />

E222 Battery protection level 2<br />

E223 Battery protection level 3<br />

20.1.3 Generator Category (4xx)<br />

Display no. Description<br />

E401 Automatic generator start (e.g. via state-of-charge-dependent generator request)<br />

E402 Automatic generator stop<br />

E403 Manual generator start<br />

E404 Manual generator stop<br />

E405 Manual error confirmation of generator fault<br />

E406 Generator request<br />

E407 Current-regulated generator operation initiated<br />

E408 Current-regulated generator operation stopped<br />

20.1.4 Electricity Grid Category (5xx)<br />

Display no. Description<br />

E507 Feed-in started<br />

E508 Feed-in stopped<br />

20.1.5 Relay Category (6xx)<br />

Display no. Description<br />

E601 Multi-function relay 1 off<br />

E602 Multi-function relay 1 on<br />

E603 Multi-function relay 1 slave 1 off<br />

E604 Multi-function relay 1 slave 1 on<br />

E605 Multi-function relay 1 slave 2 off<br />

E606 Multi-function relay 1 slave 2 on<br />

E609 Transfer relay open<br />

E610 Transfer relay closed<br />

E611 Transfer relay on slave 1 open<br />

E612 Transfer relay on slave 1 closed<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 47/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

Display no. Description<br />

E613 Transfer relay on slave 2 open<br />

E614 Transfer relay on slave 2 closed<br />

E617 Multi-function relay 2 open<br />

E618 Multi-function relay 2 closed<br />

E619 Multi-function relay 2 on slave 1 open<br />

E620 Multi-function relay 2 on slave 1 closed<br />

E621 Multi-function relay 2 on slave 2 open<br />

E622 Multi-function relay 2 on slave 2 closed<br />

E625 Digital input OFF (Low)<br />

E626 Digital input ON (High)<br />

E627 Digital input slave 1 OFF (Low)<br />

E628 Digital input slave 2 ON (High)<br />

E629 Digital input slave 2 OFF (Low)<br />

E630 Digital input slave 2 ON (High)<br />

20.1.6 System Category (7xx)<br />

Display no. Description<br />

E705 Device start<br />

E706 Date/time changed<br />

E707 New system configured in QCG<br />

E708 OCU firmware updated<br />

E709 Firmware DSP updated<br />

E710 Cluster firmware updated<br />

E711 SD card inserted<br />

E712 SD card parameter set loaded<br />

E716 Disconnection of non-regulatable PV inverter from stand-alone grid<br />

E717 Backup system test started<br />

20.1.7 External Devices and Components Category (8xx)<br />

Display no. Description<br />

E851 Sunny Island Charger 1 detected<br />

E852 Sunny Island Charger 2 detected<br />

E853 Sunny Island Charger 3 detected<br />

E854 Sunny Island Charger 4 detected<br />

E901 Event reported via ComSync<br />

E902 Event reported via ComSync<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 48/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

Display no. Description<br />

E903 Event reported via ComSync<br />

E904 Event reported via ComSync<br />

E905 Event reported via ComSync<br />

E906 Event reported via ComSync<br />

E907 Event reported via ComSync<br />

E908 Event reported via ComSync<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 49/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

20.2 Warnings and Error Messages<br />

20.2.1 Backup Inverter Category (1xx)<br />

Display no. Level Description<br />

F 109 3 Transformer overtemperature<br />

W 110 1 Transformer overtemperature slave 1<br />

W 111 1 Transformer overtemperature slave 2<br />

F 113 3 Heat sink overtemperature<br />

W 114 1 Heat sink overtemperature slave 1<br />

W 115 1 Heat sink overtemperature slave 2<br />

F 117 2 AC current limit, short-circuit control active for too long<br />

W 118 1 AC current limit slave 1, short-circuit control active for too long<br />

W 119 1 AC current limit slave 2, short-circuit control active for too long<br />

F 121 3 Inverter overvoltage<br />

W 122 1 Inverter overvoltage slave 1<br />

W 123 1 Inverter overvoltage slave 2<br />

W 137 1 Derating due to temperature<br />

W 138 1 Derating due to heat sink or transformer temperature slave 1<br />

W 139 1 Derating due to heat sink or transformer temperature slave 2<br />

F 158 2 Voltage at output AC1<br />

W 159 1 Voltage at output AC1 slave 1<br />

W 160 1 Voltage at output AC1 slave 2<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 50/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

20.2.2 Battery Category (2xx)<br />

Display no. Level Description<br />

F206 3 Battery overtemperature<br />

F208 3 Battery overvoltage error<br />

W209 1 Battery overvoltage (fixed limit for cell voltage) not generated by<br />

inverter (TotBatCur ˂ 1A)<br />

W210 1 Battery overvoltage warning<br />

W211 1 Low battery temperature warning<br />

W212 1 High battery temperature warning<br />

F213 3 Low battery voltage (fixed limit for cell voltage)<br />

W220 1 SOH < 70% warning<br />

20.2.3 External Energy Source Category (3xx)<br />

Display no. Level Description<br />

W309 1 Relay protection<br />

W310 1 Relay protection slave 1<br />

W311 1 Relay protection slave 2<br />

F314 2 External voltage failure<br />

W315 1 Disconnection from electricity grid or generator as voltage too low at<br />

AC2<br />

W316 1 Disconnection from power electricity grid or generator as voltage too<br />

low at AC2 slave 1<br />

W317 1 Disconnection from electricity grid or generator as voltage too low at<br />

AC2 slave 2<br />

W319 1 Disconnection from power electricity grid or generator as voltage too<br />

high at AC2<br />

W320 1 Disconnection from electricity grid or generator as voltage too high at<br />

AC2 slave 1<br />

W321 1 Disconnection from electricity grid or generator as voltage too high at<br />

AC2 slave 2<br />

W323 1 Disconnection from electricity grid or generator as frequency too low<br />

at AC2<br />

W324 1 Disconnection from electricity grid or generator as frequency too low<br />

at AC2 slave 1<br />

W325 1 Disconnection from electricity grid or generator as frequency too low<br />

at AC2 slave 2<br />

W327 1 Disconnection from electricity grid or generator as frequency too high<br />

at AC2<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 51/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

Display no. Level Description<br />

W328 1 Disconnection from electricity grid or generator as frequency too high<br />

at AC2 slave 1<br />

W329 1 Disconnection from electricity grid or generator as frequency too high<br />

at AC2 slave 2<br />

W331 1 Disconnection from electricity grid or generator due to breach of<br />

anti-islanding<br />

W332 1 Disconnection from electricity grid or generator due to breach of<br />

anti-islanding on slave 1<br />

W333 1 Disconnection from electricity grid or generator due to breach of<br />

anti-islanding on slave 2<br />

W335 1 Disconnection from electricity grid or generator due to breach of<br />

voltage limits (redundant measurement)<br />

W336 1 Disconnection from electricity grid or generator due to breach of<br />

voltage limits on slave 1 (redundant measurement)<br />

W337 1 Disconnection from electricity grid or generator due to breach of<br />

voltage limits on slave 2 (redundant measurement)<br />

W339 1 Disconnection from electricity grid or generator due to frequency<br />

increase protection<br />

W340 1 Disconnection from electricity grid or generator due to frequency<br />

increase protection on slave 1<br />

W341 1 Disconnection from electricity grid or generator due to frequency<br />

increase protection on slave 2<br />

W347 1 Disconnection from electricity grid or generator due to overload<br />

20.2.4 Generator Category (4xx)<br />

Display no. Level Description<br />

W402 1 FailLock generator state<br />

20.2.5 Electricity Grid Category (5xx)<br />

Display no. Level Description<br />

W501 1 Grid reverse current prevented (quick grid disconnection)<br />

W505 1 Feed-in current greater than nominal line current<br />

W506 1 Feed-in current of slave 1 greater than nominal line current<br />

W507 1 Feed-in current of slave 2 greater than nominal line current<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 52/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

20.2.6 Relay Category (6xx)<br />

Display no. Level Description<br />

F605 4 Transfer relay does not open<br />

W606 1 Transfer relay does not open on slave 1<br />

W607 1 Transfer relay does not open on slave 2<br />

20.2.7 System Category (7xx)<br />

Display no. Level Description<br />

F702 5 DSP reset<br />

F703 2 Timeout during a task<br />

F704 4 Invalid DSP calibration<br />

W705 1 DSP watchdog has been tripped<br />

F706 4 Watchdog countdown expired<br />

W707 1 Watchdog countdown slave 1 expired<br />

W708 1 Watchdog countdown slave 2 expired<br />

F710 4 Autostart countdown expired (several autostarts in succession)<br />

W713 1 Watchdog has been tripped<br />

F720 4 Short circuit or cable break in temperature sensor on transformer<br />

F721 4 Short circuit or cable break in temperature sensor on heat sink<br />

W722 1 Short circuit on battery temperature sensor<br />

W723 1 Cable break on battery temperature sensor<br />

W724 1 Autostart countdown slave 1 expired<br />

W725 1 Autostart countdown slave 2 expired<br />

F731 4 Error in cluster configuration<br />

F732 4 Error in address assignment of cluster inverters<br />

F733 4 No message from cluster master (only slave)<br />

W734 1 No message from cluster slave 1<br />

W735 1 No message from cluster slave 2<br />

W738 1 Synchronization with generator or electricity grid not successful<br />

F739 3 Internal device communication of master interrupted<br />

W740 1 Internal device communication of slave 1 interrupted<br />

W741 1 Internal device communication of slave 2 interrupted<br />

F743 3 Internal CAN communication of master interrupted<br />

W744 1 Internal CAN communication of slave 1 interrupted<br />

W745 1 Internal CAN communication of slave 2 interrupted<br />

W747 1 Short circuit or cable break in temperature sensor on transformer<br />

slave 1<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 53/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

Display no. Level Description<br />

W748 1 Short circuit or cable break in temperature sensor on transformer<br />

slave 2<br />

W750 1 Short circuit or cable break in temperature sensor on heat sink slave 1<br />

W751 1 Short circuit or cable break in temperature sensor on heat sink slave 2<br />

W753 1 Invalid system time<br />

F754 2 Communication with Automatic Switch Box interrupted<br />

W755 1 Low battery mode 1<br />

W756 1 Low battery mode 2<br />

W757 1 Low battery mode 3<br />

F783 2 Internal device syncpulse in master missing<br />

W784 1 Internal device syncpulse in slave 1 missing<br />

W785 1 Internal device syncpulse in slave 2 missing<br />

20.2.8 External Devices and Components Category (8xx)<br />

Display no. Level Description<br />

F801 4 Plausibility check of contactors in a Multicluster Box failed<br />

W802 1 PV energy in grid operation not available<br />

W803 1 PV energy in grid operation not available (K1 or K2 error)<br />

W804 1 Grid operation not possible<br />

W805 1 Generator operation not possible<br />

F806 4 Automatic Switch Box setting does not match software setting<br />

W807 1 No valid line voltage for requested grid operation<br />

W808 1 Error in Q4 contactor<br />

F809 4 Error in Q10 contactor (load shedding)<br />

F810 4 Error in 15 V supply of the Automatic Switch Box<br />

F811 4 Error in 24 V supply of the Automatic Switch Box<br />

W812 1 Error in Q1 contactor<br />

W813 1 Error in Q2 contactor<br />

W814 1 Error in Q3 contactor<br />

W815 1 Error in Q5 contactor<br />

F816 2 Error in Q7 contactor<br />

F817 4 Error in Q9 contactor<br />

F818 2 A line conductor is missing, the Automatic Switch Box goes into the<br />

status Failure<br />

W828 1 Thermo fuse of the grounding resistance has been tripped<br />

(Automatic Switch Box M-20/L-20)<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 54/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

Display no. Level Description<br />

W840 1 Faulty communication between Meter Box for Sunny Backup and PV<br />

production meter<br />

W841 1 Faulty communication between Meter Box for Sunny Backup and<br />

meter for grid feed-in and purchased electricity<br />

W842 1 Communication between Sunny Backup and Meter Box for<br />

Sunny Backup interrupted for longer than 5 seconds<br />

W843 1 Device-internal timeout in Meter Box for Sunny Backup<br />

W844 1 Measured values of the PV production meter are incomplete or the PV<br />

production meter is not compatible with Meter Box for Sunny Backup<br />

W845 1 Measured values of the meter for grid feed-in and purchased electricity<br />

are incomplete or the meter is not compatible with the Meter Box for<br />

Sunny Backup<br />

W846 1 Reading head on an energy meter incorrectly connected to the Meter<br />

Box for Sunny Backup: At least 2 connection cables swapped<br />

W851 1 Battery reverse connected or short circuit on Sunny Island Charger 1<br />

W852 1 Battery overvoltage on Sunny Island Charger 1<br />

W853 1 Overvoltage PV array on Sunny Island Charger 1<br />

W854 1 No PV voltage or short circuit on Sunny Island Charger 1<br />

W855 1 Sensor error or overtemperature on Sunny Island Charger 1<br />

W856 1 Overtemperature on Sunny Island Charger 1<br />

W857 1 No communication with Sunny Island Charger 1 for more than<br />

24 hours<br />

W861 1 Battery connection reverse connected or short circuit on<br />

Sunny Island Charger 2<br />

W862 1 Battery overvoltage on Sunny Island Charger 2<br />

W863 1 Overvoltage PV array on Sunny Island Charger 2<br />

W864 1 No PV voltage or short circuit on Sunny Island Charger 2<br />

W865 1 Sensor error or overtemperature on Sunny Island Charger 2<br />

W866 1 Overtemperature on Sunny Island Charger 2<br />

W867 1 No communication with Sunny Island Charger 2 for more than<br />

24 hours<br />

W871 1 Battery reverse connected or short circuit on Sunny Island Charger 3<br />

W872 1 Battery overvoltage on Sunny Island Charger 3<br />

W873 1 Overvoltage PV array on Sunny Island Charger 3<br />

W874 1 No PV voltage or short circuit on Sunny Island Charger 3<br />

W875 1 Sensor error or overtemperature on Sunny Island Charger 3<br />

W876 1 Overtemperature on Sunny Island Charger 3<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 55/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

Display no. Level Description<br />

W877 1 No communication with Sunny Island Charger 3 for more than<br />

24 hours<br />

W881 1 Battery reverse connected or short circuit on Sunny Island Charger 4<br />

W882 1 Battery overvoltage on Sunny Island Charger 4<br />

W883 1 Overvoltage PV array on Sunny Island Charger 4<br />

W884 1 No PV voltage or short circuit on Sunny Island Charger 4<br />

W885 1 Sensor error or overtemperature on Sunny Island Charger 4<br />

W886 1 Overtemperature on Sunny Island Charger 4<br />

W887 1 No communication with Sunny Island Charger 4 for more than<br />

24 hours<br />

W890 2 Disturbance at external measurement point of Multicluster Box<br />

W891 2 Disturbance at external measurement point of Multicluster Box slave 1<br />

W892 2 Disturbance at external measurement point of Multicluster Box slave 2<br />

20.2.9 General Category (9xx)<br />

Display no. Level Description<br />

W915 1 Software error<br />

F920 3 Error via ComSync: general<br />

F921 3 Maximum battery voltage exceeded<br />

F922 3 Minimum battery voltage not met<br />

F923 3 Maximum battery temperature exceeded<br />

F924 3 Minimum battery temperature not met<br />

F925 3 Maximum battery temperature exceeded during battery charge<br />

F926 3 Minimum battery temperature not met during battery charge<br />

F927 3 Maximum charge current of battery exceeded<br />

F928 3 Maximum charge current of battery exceeded when charging<br />

F929 3 Battery with own battery management has disconnected itself from the<br />

off-grid inverter<br />

F930 3 Battery short circuit<br />

F931 3 Battery management of the battery reports internal error<br />

F932 3 Battery management of the battery reports voltage differences<br />

between the cells (cell imbalance)<br />

F933 3 Error via ComSync: reserved<br />

F934 3 Error via ComSync: reserved<br />

F935 3 Generator management reports an error<br />

W936 1 Warning via ComSync: general<br />

W937 1 Maximum battery voltage exceeded<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 56/60


<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Troubleshooting and Problem Solving<br />

Display no. Level Description<br />

W938 1 Minimum battery voltage not met<br />

W939 1 Maximum battery temperature exceeded<br />

W940 1 Minimum battery temperature not met<br />

W941 1 Maximum battery temperature exceeded during battery charge<br />

W942 1 Minimum battery temperature not met during battery charge<br />

W943 1 Maximum charge current of battery exceeded<br />

W944 1 Maximum charge current of battery exceeded when charging<br />

W945 1 Battery with own battery management has disconnected itself from the<br />

off-grid inverter<br />

W946 1 Battery short circuit<br />

W947 1 Battery management of the battery reports internal error<br />

W948 1 Battery management of the battery reports voltage differences<br />

between the cells (cell imbalance)<br />

W949 1 Warning via ComSync: reserved<br />

W950 1 Warning via ComSync: reserved<br />

W951 1 Generator management reports an error<br />

<strong>Errata</strong> <strong>Sheet</strong> ParaSBU50-E-TB-en-11 57/60


��������������������<br />

�����������������<br />

�����������������������<br />

����������<br />

�����������������������<br />

������������������������<br />

���������������������<br />

�������������������<br />

�����������������������������������<br />

��������������������<br />

�����������������������������������<br />

�����������������<br />

�����������������<br />

������������������<br />

�������������<br />

������������������<br />

������������������������������������<br />

�������������������<br />

��������������������������<br />

�����������������<br />

�����������������<br />

������������������<br />

��������������<br />

�����������������<br />

������������������������������<br />

�����������������<br />

��������������������<br />

��������������<br />

�������������������������������������������������<br />

��������������������<br />

������������������������������<br />

��������������������<br />

�����������������<br />

���������������

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!