4-138 Heat Exchanger<br />

Refer to the TASC<br />

Thermal Reference<br />

guide for information<br />

about the selections<br />

available.<br />

Specification Description<br />

Bundle Band<br />

Orientation<br />

Pass Partitions Group<br />

You can select the bundle band orientation from the<br />

drop-down list. There are three selections:<br />

• Default (horizontal)<br />

• Horizontal<br />

• Vertical<br />

Tube Alignment You can select the tube alignment from the drop-down<br />

list. There are four selections:<br />

• Default (if yes 45 90)<br />

• Fully aligned<br />

• Unaligned<br />

• Part aligned<br />

Layout<br />

Symmetry<br />

Pairs of Sealing<br />

Strips<br />

You can select the layout symmetry from the dropdown<br />

list. There are four selections:<br />

• Default (sym.case 1)<br />

• Symmetry (case 1)<br />

• Symmetry (case 2)<br />

• Not enforced<br />

Number of pairs of sealing strips.<br />

The Pass Partitions group allows you to specify information used<br />

to configure the pass partition.<br />

Specification Description<br />

Pass Partition<br />

Layout<br />

Vertical PP Lane<br />

Width<br />

Horizontal PP<br />

Lane Width<br />

You can select the type of pass partition from the dropdown<br />

list. There are four selections:<br />

• Not set<br />

• H Banded<br />

• Double Banded<br />

• Ribbon Banded<br />

Vertical pass partition lane width.<br />

Horizontal pass partition lane width.<br />

4-138