Philips Healthcare
Philips Healthcare
Philips Healthcare
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Philips</strong> New ECG Cables and Leads Selection Guide Chapter 3 – Cables and Lead Sets<br />
Use <strong>Philips</strong> New<br />
If you have this monitoring Trunk Cable<br />
device:<br />
(Product Number)<br />
6-Lead Trunk Cable (12-pin connector)<br />
M8102A MP2 Monitor M1667A<br />
Length: 9’ (2.7m)<br />
M8105A MP5 Monitor<br />
Note: The monitoring<br />
M3001A Intellivue<br />
equipment must be<br />
Multi-Measurement Module configured for full<br />
6-Lead functionality.<br />
M3002A IntelliVue MMS X2<br />
U.S. (AAMI Color Coding)<br />
If you have this monitoring<br />
device:<br />
M3002A IntelliVue MMS X2<br />
M3535A/M3536A<br />
HeartStart MRx<br />
Defibrillator/Monitor<br />
The M1667A 6-Lead<br />
Trunk Cable can also<br />
be used for standard 3<br />
and 5-Lead monitoring<br />
with the new 3-Lead<br />
or 5-Lead sets.<br />
Use <strong>Philips</strong> New<br />
Trunk Cable<br />
(Product Number)<br />
Note: The monitoring<br />
equipment must be<br />
configured for full<br />
10-Lead functionality to<br />
take conventional<br />
diagnostic 12-lead.<br />
The M1667A 10-Lead<br />
Trunk Cable can also be<br />
used for standard 5-Lead<br />
monitoring with the new<br />
5-Lead sets.<br />
M1680A (ICU grabber, limb)<br />
M1682A (ICU snap, limb)<br />
M1684A (OR grabber, limb)<br />
With one of <strong>Philips</strong> New<br />
Lead Sets<br />
(Product Number)<br />
10-Lead Trunk Cable: 5-Lead + 5-Lead (12-pin connector)<br />
M8102A MP2 Monitor M1663A<br />
M1968A (ICU grabber, limb)<br />
M8105A MP5 Monitor<br />
Length: 6.5’ (2m) M1976A (ICU grabber, chest)<br />
M1644A (ICU snap, limb)<br />
M1602A (ICU snap, chest)<br />
M3001A Intellivue<br />
Multi-Measurement Module<br />
M1973A (OR grabber, limb)<br />
M1979A (OR grabber, chest)<br />
The M1667A 10-Lead<br />
Trunk Cable can also be<br />
used for standard 5-Lead<br />
monitoring with the new<br />
5-Lead sets.<br />
With one of <strong>Philips</strong> New Lead<br />
Sets<br />
(Product Number)<br />
10-Lead Trunk Cable: 6-Lead + 4-Lead (12-pin connector)<br />
M8102A MP2 Monitor M1665A<br />
M1680A (ICU grabber, limb)<br />
M8105A MP5 Monitor<br />
Length: 9’ (2.7m) M1532A (ICU grabber, chest)<br />
M1682A (ICU snap, limb)<br />
M1537A (ICU snap, chest)<br />
M3001A Intellivue<br />
Multi-Measurement Module<br />
Note: Note: The<br />
monitoring equipment<br />
must be configured for<br />
M1684A (OR grabber, limb)<br />
M1557A (OR grabber, chest)<br />
M3002A IntelliVue MMS X2 full 10-lead functionality<br />
to take conventional<br />
diagnostic 12-lead.<br />
To replace<br />
<strong>Philips</strong> Old<br />
Trunk Cable<br />
To replace <strong>Philips</strong><br />
Old IntelliVue<br />
Trunk Cable<br />
M1949A<br />
6-Lead = limb<br />
4-Lead = chest<br />
and<br />
Lead Sets<br />
http://shop.medical.philips.com <strong>Philips</strong> Medical Supplies Reference Guide 3-5