01.02.2013 Views

Industrial Fluorescent - Dickman Supply

Industrial Fluorescent - Dickman Supply

Industrial Fluorescent - Dickman Supply

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FLUORESCENT HIGH BAYS<br />

FLUORESCENT LOW BAYS<br />

COMPLEX ENVIRONMENT<br />

REFLECTOR KITS<br />

<strong>Industrial</strong> <strong>Fluorescent</strong><br />

Energy Solutions


1<br />

Our world is increasingly recognizing the importance of environmental sustainability<br />

and efficiency in building design. While cost containment and productivity gains<br />

are universal demands, increasing lighting efficiency requires an understanding of<br />

the role lighting plays in the business environment.<br />

Cooper Lighting has always been at the forefront in adopting and adapting to the<br />

latest advancements in lighting technology. Over the years, businesses and<br />

communities have benefitted from partnering with Cooper Lighting to improve<br />

energy efficiency and reduce costs while protecting and enriching the environment.<br />

To those of you considering a more efficient lighting upgrade, this brochure presents<br />

a variety of products and provides tips on how to make your retrofit project a<br />

success. A Cooper Lighting energy efficient lighting upgrade will reduce your utility<br />

bill; improve employee morale<br />

and productivity; and help<br />

protect and preserve<br />

the environment.


Table of Contents<br />

The <strong>Fluorescent</strong> Advantage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 3<br />

Energy Savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 3<br />

Lamp Life and Lumen Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 3<br />

Uniformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 3<br />

Instant On/Off and Occupancy Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 4<br />

T8 or T5HO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 4<br />

Thermal Performance and Light Output . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 5<br />

Visible Light and the Scotopic/Photopic (S/P) Ratio . . . . . . . . . . . . . . . . . .pg. 6<br />

Environmentally Friendly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 6<br />

Product Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 7-8<br />

HB/2HB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 9-14<br />

I5/I8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 15-18<br />

MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 19-20<br />

3HBOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 21-22<br />

2HBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 23-24<br />

HBHD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 25-26<br />

ARCTIC BAY - AB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 27-28<br />

VT2/VT3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 29-30<br />

ECOFIT - STRIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 31-32<br />

ECOFIT - TROFFERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 33-34<br />

OPTIONS AND ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 35-36<br />

MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 37-38<br />

OCCUPANCY SENSORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 39<br />

POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 40<br />

I5/I8 DOOR FRAMES AND WIREGUARDS . . . . . . . . . . . . . . . . . . . . . . . . .pg. 41<br />

HB/2HB DOOR FRAMES AND WIREGUARDS . . . . . . . . . . . . . . . . . . . . . . .pg. 42<br />

2


3<br />

The <strong>Fluorescent</strong> Advantage<br />

The most popular and productive lighting upgrades today involve replacing outdated fluorescent or HID (High Intensity Discharge)<br />

lighting systems. High Performance fluorescent lighting systems from Cooper Lighting utilize the latest technologies and design<br />

platforms to provide dramatic energy savings and superior performance.<br />

Energy Savings<br />

Cooper Lighting fluorescent high bays<br />

offer dramatic energy savings<br />

opportunities over HID Lighting<br />

systems and provide quick returns.<br />

500<br />

400<br />

300<br />

200<br />

100<br />

0<br />

KWH<br />

$0.06<br />

$0.08<br />

$0.10<br />

$0.12<br />

(based on<br />

4000 hrs.)<br />

455<br />

400 Watt<br />

High Bay<br />

346<br />

F-Bay<br />

2HB-654 T5HO<br />

$26.16<br />

$34.88<br />

$43.60<br />

$53.32<br />

Lamp Life and Lumen Maintenance<br />

T5 and T8 fluorescent systems provide<br />

better maintained light levels over<br />

magnetic HID lighting systems with<br />

twice the lamp life. Multiple lamped<br />

fluorescent luminaires reduce the need<br />

for immediate maintenance. With<br />

fluorescent systems, the other lamps<br />

will stay illuminated when individual<br />

lamps extinguish.<br />

Uniformity<br />

Linear fluorescent<br />

systems improve<br />

lighting uniformity<br />

compared with HID<br />

systems.<br />

LIGHT OUTPUT<br />

221<br />

F-Bay<br />

2HB-632<br />

$56.16<br />

$74.88<br />

$93.60<br />

$112.32<br />

ANNUAL ENERGY SAVINGS<br />

229<br />

F-Bay<br />

I5-454 T5HO<br />

$54.24<br />

$72.32<br />

$90.40<br />

$108.48<br />

Lamp Life & Lumen Maintenance<br />

Initial 5000 10000 15000 20000 25000 35000<br />

HOURS<br />

Dimensions 160 x 10<br />

400W MH 4-Lamp 54W 6-Lamp 32W<br />

Fixture Type High Bay T5HO I5 Series HBF 2HB Series<br />

Number of Fixtures 13 13 13<br />

Initial Lumens per Lamp 36000 4400 2850<br />

Initial Lumens per Fixture 36000 17600 17100<br />

Light Loss Factor 0.66 0.855 0.963<br />

Input Wattage 455 229 221<br />

Maintained Average FC 43 33 43<br />

Max FC 47 38 48<br />

Min FC 37 27 36<br />

Average to Min 1.2 1.2 1.2<br />

Max to Min 1.3 1.4 1.3<br />

Vertical Average FC 22 15 20<br />

Max FC 35 23 30<br />

Min FC 12 9 11<br />

Average to Min 2.9 1.7 2.7<br />

400 Watt<br />

High-Bay<br />

400 Watt High Bay<br />

T5 HO 6-Lamp<br />

T8 HO Ballast 6-Lamp<br />

T5 HO 4-Lamp<br />

End of Lamp Life<br />

Metalux<br />

2HB-632 T8


Instant On/Off and Occupancy Sensors<br />

<strong>Fluorescent</strong> systems can be used with occupancy sensors to provide instant on/off capabilities to maximize energy savings.<br />

When using T8 lamps and occupancy sensors, Cooper Lighting industrial fluorescent luminaires use only softer starting<br />

“program start” ballasts to minimize damage to the lamp. Under frequent on/off cycles, program start ballasts will dramatically<br />

extend lamp life over “instant start” ballasts.<br />

Metalux integral Occupancy Sensors<br />

are available in Aisle or 360°<br />

distributions.<br />

T8 or T5HO?<br />

If your facility currently has T8 or T5HO lamps installed, the decision on lamp choice may be easy and allow for inventory<br />

consolidation. Both lamp types provide excellent performance but the attributes of each lamp type vary. Selection of lamp<br />

type is an important consideration. The following operating characteristics should be considered when making the selection:<br />

<strong>Fluorescent</strong> High Bay System Comparison<br />

First Costs<br />

Lamp Replacement Costs<br />

Lumens Per Watt<br />

Application Heights<br />

Ambient Environments<br />

Frequency of Starts<br />

Ballasts Light Level<br />

Flexibility<br />

Luminaires in Comparison<br />

HRS/LAMP LIFE<br />

40000<br />

35000<br />

30000<br />

25000<br />

20000<br />

15000<br />

10000<br />

5000<br />

0<br />

T8 Lighting Systems T5HO Lighting Systems<br />

Similar within ranges to T5 systems with lower lamp costs offset<br />

by larger luminaire sizes.<br />

Lower cost lamps offset with higher quantity<br />

for similar light output<br />

77 77<br />

Suitable in wide ranges. Lower lumen output T8’s ideal<br />

for lower mounting heights below 15' and less ideal in<br />

mounting heights above 30'.<br />

Dependent on luminaire. T8 systems achieve maximum output<br />

in 78°F (25°C) ambient environments. Starting temperature<br />

ranges as low as 0°F (-18°C) dependent on manufacturer of<br />

lamp, ballast, age of lamps and luminaire design<br />

Standard T8 systems with instant start ballasts and frequent<br />

on/off cycles can dramatically reduce lamp life. Program<br />

Start T8 ballasts should be specified when used with high<br />

occurrence of on/off cycles.<br />

Lamp Life Comparison<br />

15 min. 30 min. 1 hr. 3 hr. 12 hr. Continuous<br />

START FREQUENCY<br />

Similar within ranges to T8 systems with higher lamp costs offset<br />

by smaller luminaire sizes.<br />

Higher cost lamps offset with lower required quantity<br />

for similar light output<br />

Suitable in wide ranges. Higher output T5HO lamps ideal for higher<br />

mounting heights where higher lumen values allow for a reduced<br />

number of lamps.<br />

Dependent on luminaire. T5HO systems achieve maximum output<br />

in 95°F (35°C) ambient environments. Starting temperature<br />

ranges as low as -20°F (-29°C) dependent on manufacturer of<br />

lamps, ballast, age of lamps and luminaire design<br />

Standard Program Start ballasted systems ideal for frequent starts<br />

and with use of occupancy sensors.<br />

Offered in multiple light output ranges typically from<br />

71% to 115% of rated lamp life output allowing for<br />

flexibility in application without changing lamp type. Currently offered in fixed Light output ranges.<br />

Metalux 2HB632/PLUS using (6) 80+CRI T8 lamps with<br />

High Output ballasts.<br />

Metalux I5455 using (4) T5HO 80+CRI lamps.<br />

Net Lumens: 17100 Wattage: 221 Net Lumens: 17600 Wattage: 229<br />

Program Start Ballasts<br />

Instant Start Ballasts<br />

4


5<br />

Thermal Performance and Light Output<br />

Unlike HID lamps, T5 and T8 lamps reach optimal light output in specific temperature ranges. In partially or unconditioned spaces,<br />

temperatures from floor to ceiling can increase by over 20° in summer months.<br />

40 ft.<br />

30 ft.<br />

20 ft.<br />

10 ft.<br />

Partially Conditioned Spaces<br />

35 ft. @ 115°F (46°C)<br />

20 ft. @ 95°F (35°C)<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

75°F (24°C)<br />

°C 0 5 10 15 20 25 30 35 40 45 50 55 60<br />

°F 30 40 50 60 70 80 90 100 110 120 130 140<br />

AMBIENT TEMPERATURES<br />

Thermally advanced Cooper Lighting industrial products optimize light output of T5HO and T8 lamps for their designed temperature<br />

ranges. Choose lamp types that optimize light output for your ambient environment and consider the use of T5HO Amalgam lamps<br />

for higher performance over wider temperature ranges.<br />

ARCTIC BAY – AB Series<br />

Bare Lamp Output in Ambient Temperatures<br />

77°F<br />

(25°C)<br />

95°F<br />

(35°C)<br />

The Metalux Arctic Bay retains and manages heat allowing it to provide over<br />

85% of light output in freezer applications down to -15°F (-26°C).<br />

Annual Temperature Days Over 85°F (29°C)<br />

HID<br />

T8<br />

T5<br />

Amalgam<br />

COLD HOT<br />

Days over 85°F<br />

0-10<br />

11-40<br />

41-70<br />

71-99<br />

100+<br />

Metalux’s F-Bay series can be operated in environments<br />

up to 149°F (65°C) in open configurations.


Visible Light and the Scotopic/Photopic (S/P) Ratio<br />

Scotopic/photopic ratios have been developed that attempt to replicate a measurement system more akin to how our<br />

eyes perceive brightness. Even though our eyes use both rods and cones to see light, the rods are more sensitive to blue<br />

light (scotopic vision) and cones to yellow light (photopic vision). A traditional light meter measures only photopic lumens,<br />

which are the stated lumens referenced in lamp catalogs.<br />

The S/P Ratio acts as an adjustment to<br />

the existing photopic measurement by<br />

multiplying the standard lumens of a<br />

source with the S/P ratio or a factor<br />

thereof. As a result, an environment<br />

illuminated with warmer light sources,<br />

such as High Pressure Sodium, may<br />

appear darker than an environment<br />

illuminated with cooler light sources,<br />

like high CCT fluorescent lamps.<br />

HPS vs. 5000K fluorescent – a visible difference!<br />

Environmentally Friendly<br />

LUMEN OUTPUT<br />

50000<br />

25000<br />

0<br />

A S/P Comparison of <strong>Fluorescent</strong> vs. HID<br />

40% MORE<br />

LUMENS<br />

2HB632 w/80 CRI<br />

5000K Lamps<br />

20% LESS<br />

LUMENS<br />

400W HPS High Bay<br />

Initial System Lumens<br />

S/P Adjusted Initial Lumens<br />

While an increasing number of lighting designers are<br />

endorsing the use of S/P ratios, this has not yet been<br />

endorsed by the Illuminating Engineering Society (IES).<br />

Cooper Lighting provides S/P adjusted lumen values<br />

throughout the product specification sections as<br />

reference information only and maintains no formal<br />

position on its application. Always test proposed products<br />

in application to validate results to your expectations<br />

Cooper Lighting fluorescent luminaires are environmentally friendly. Housings and reflector assemblies are manufactured of recyclable<br />

steel and aluminum substrates and corrugated packaging is both recyclable and optimized in design to reduce waste on the job site.<br />

The use of low mercury fluorescent lamps<br />

also offers an attractive alternative to HID<br />

systems. A low mercury T5HO fluorescent<br />

lamp can contain as little 1.4 Mg. of<br />

mercury compared with up to 70 Mg. for<br />

a 400 watt Metal Halide lamp.<br />

6


7<br />

Description<br />

Lamping<br />

Replaces<br />

Listings & Certification<br />

Mounting<br />

pgs. 9-14 pgs. 15-18 pgs. 19-20 pgs. 21-22<br />

HB/2HB<br />

Industry-leading fluorescent<br />

high bay, HB & 2HB series<br />

features specification grade full<br />

body housing with two optical<br />

distributions - medium and<br />

wide - for structural integrity<br />

and optimal performance in<br />

conventional HID applications.<br />

HB: 2, 3, 4, lamp T5, T5HO, T8<br />

2HB: 6 lamp T5, T5HO, T8<br />

150-400 Watt HPS<br />

175-400 Watt MH<br />

HO, VHO T12 <strong>Fluorescent</strong><br />

UL/cUL Listed Damp Location<br />

Optional modular power receptacle<br />

meets UL2459 and NEC 410.73<br />

(G) for make and break under<br />

load from outside to the luminaire<br />

to speed maintenance<br />

Thermally optimized for<br />

environments up to 149°F (65°C)<br />

when used with high temperature<br />

ballasts in open uplight and<br />

downlight configurations<br />

T5 systems are warranted for<br />

ambient environments up to 104°F<br />

(40°C) in open uplight configurations<br />

T8 Systems are warranted for<br />

environments up to 122°F (50°C)<br />

in open uplight and downlight<br />

configurations<br />

AYC Chain, Top Connector Box,<br />

Gripple Y, HB Single Point<br />

Suspension, Stem Sets<br />

I5/I8<br />

Narrow 11" specification grade<br />

body with two optics for<br />

medium and wide distributions<br />

and shielding options for industrial<br />

and aesthetic upgrades for<br />

retail and commercial<br />

applications.<br />

4': 2, 3, 4 lamp T5, T5HO, T8<br />

8': 4, 6, 8 lamp T5, T5HO, T8<br />

150-400 Watt HPS<br />

150-1000 Watt MH<br />

Slimline, HO, VHO T12 <strong>Fluorescent</strong><br />

UL/cUL Listed Damp Location<br />

Optional modular power receptacle<br />

meets UL2459 and NEC 410.73<br />

(G) for make and break under<br />

load from outside to the luminaire<br />

to speed maintenance<br />

Thermally optimized for<br />

environments up to 149°F (65°C)<br />

when used with high temperature<br />

ballasts in open uplight and<br />

downlight configurations<br />

T5 systems are warranted for<br />

ambient environments up to 104°F<br />

(40°C) in open uplight configurations<br />

T8 Systems are warranted for<br />

environments up to 122°F (50°C)<br />

in open uplight and downlight<br />

configurations<br />

AYC Chain, Top Connector Box,<br />

Gripple Loop, Gripple Toggle<br />

MB<br />

High performance in narrow<br />

package with three optical<br />

distributions - Focus, Task,<br />

Normal - providing lower lighting<br />

power densities than HID and<br />

T12 sources at higher mounting<br />

heights. Continuous row<br />

installations provide unmatched<br />

uniformity performance.<br />

4': 1, 2 lamp T5HO, T8<br />

8': 2, 4 lamp T5HO, T8<br />

150-400 Watt HPS<br />

175-400 Watt MH<br />

HO, VHO T12 <strong>Fluorescent</strong><br />

3HBOT<br />

Specification grade wide open<br />

body with optional side rails<br />

(3HBOT) is available with two<br />

optical distributions - medium<br />

and wide.<br />

3HBOT: 8 lamp T5HO, T8<br />

400-1000 Watt, HPS<br />

400-1000 Watt MH<br />

UL/cUL Listed Damp Location UL/cUL Listed Damp Location<br />

AYC Chain, Gripple Y, Gripple<br />

Single Toggle<br />

Optional modular power<br />

receptacle meets UL2459 and<br />

NEC 410.73 (G) for make and<br />

break under load from outside<br />

to the luminaire to speed<br />

maintenance<br />

Thermally optimized for<br />

environments up to 122°F (50°C)<br />

when used with high temperature<br />

environment ballasts<br />

AYC Chain, Top Connector Box,<br />

Gripple Y, HB Single Point<br />

Suspension


Description<br />

Lamping<br />

Replaces<br />

Listings & Certification<br />

Mounting<br />

pgs. 23-24 pgs. 25-26<br />

pgs. 27-28 pgs. 29-30<br />

HBG HBHD Arctic Bay VT2/VT3<br />

Energy-efficient alternative<br />

for recessed grid/lay-in<br />

concealed T, and slot grid<br />

ceilings and flange trim<br />

applications. HBG is available<br />

with optional shielding<br />

options for a seamless<br />

ceiling line.<br />

Designed for use in high<br />

mounting height applications<br />

where periodic cleaning<br />

with high pressure is<br />

required. The 2HBHD is a<br />

surface mounted luminaire<br />

with a hole-free design and<br />

enclosed and gasketed to<br />

provide 800 psi hose down<br />

protection.<br />

The Arctic Bay's enclosed<br />

full body housing and sealed<br />

and gasketed door frame<br />

provide optimal lamp<br />

operation - 90% rated light<br />

output down to -15°F (-26°C).<br />

2HBG: 4, 6 lamp T5, T5HO, T8 2HBHD: 4, 6 lamp T5, AB: 4 lamp T5HO<br />

T5HO, T8<br />

2AB: 6 lamp T5HO<br />

150-400 Watt HPS<br />

175-400 Watt MH<br />

HO, VHO T12 <strong>Fluorescent</strong><br />

250-400 Watt HPS<br />

250-400 Watt MH<br />

HO, VHO T12 <strong>Fluorescent</strong><br />

UL/cUL Listed Damp Location UL/cUL Listed Wet Location<br />

Manufactured in compliance<br />

with USDA, FDA, NSF and<br />

Federal Standard 209E in<br />

surface mount applications<br />

IP65 Compliant<br />

Recessed Grid or Flange Surface mount or<br />

Pendant mount<br />

150-400 Watt HPS<br />

175-400 Watt MH<br />

HO, VHO T12 <strong>Fluorescent</strong><br />

UL/cUL Listed Damp Location<br />

Thermally optimized for<br />

environments down to -20°F<br />

(-29°C)<br />

AYC Chain, Top Connector<br />

Box, Gripple Y, HB Single<br />

Point Suspension, Stem Sets<br />

Energy efficient<br />

Vaportite fixture<br />

featuring T8 and T5HO<br />

lamp configurations<br />

with two optical<br />

distributions from a<br />

rugged and durable<br />

fiberglass housing<br />

and high impact<br />

diffuser.<br />

4': 1, 2, 3 lamp T8<br />

1, 2 lamp T5HO,<br />

50-400 Watt HPS<br />

50-400 Watt MH<br />

Slimline, HO, VHO T12<br />

<strong>Fluorescent</strong><br />

UL/cUL Listed Wet<br />

Location<br />

IP65 Compliant<br />

pgs. 31-34<br />

Ecofit Kits<br />

<strong>Industrial</strong> & Troffer<br />

Ecofit conversion kits<br />

are an economical<br />

means of increasing<br />

fixture efficiency<br />

and energy savings<br />

when fixture removal<br />

is cost-prohibitive.<br />

<strong>Industrial</strong> Strip<br />

4': 1, 2 lamp T8, T5HO<br />

8': 2, 4 lamp T8, T5HO<br />

8': 2, 4, 6 lamp T8<br />

2, 4, lamp T5HO Troffer 24" x 24",<br />

24" x 48": 2, 3 lamp<br />

T5HO, T8<br />

Mounting Bracket<br />

Included or<br />

VT2 Chain/Set-U<br />

<strong>Industrial</strong> Strip<br />

Slimline, HO, VHO T12<br />

<strong>Fluorescent</strong> with<br />

channels 4"-5-1/4" wide<br />

Troffer<br />

3, 4 lamp T12, T8<br />

<strong>Fluorescent</strong>, nominal<br />

24" x 24", 24" x 48"<br />

UL/cUL Listed<br />

Fixture Accessory<br />

N/A<br />

8


9<br />

HB/2HB HIGH-BAY INDUSTRIAL LUMINAIRE<br />

Full bodied housing utilizes captive fasteners to protect<br />

optical assembly and assure structural integrity.<br />

Optional top access plate allows service<br />

in electrical compartment<br />

without removal of lamps.<br />

(T8 option only)<br />

Optional uplight<br />

apertures<br />

(approximately<br />

8% uplight)<br />

Optional modular power receptacle<br />

meets UL2459 and NEC 410.73 and<br />

is UL/cUL rated for make and<br />

break under load from outside<br />

the luminaire to speed<br />

maintenance.<br />

Modular F-Bay Power <strong>Supply</strong><br />

1. Modular Power <strong>Supply</strong> Receptacle supplied<br />

mounted into fixture Access Plate<br />

2. Modular Power Cord & Plugs in 120, 277, 347,<br />

& 480V configurations for easy plug & power<br />

into existing supply<br />

Housing is “Post” painted with a high<br />

performance polyester powder coat finish to<br />

protect against contaminants and oxidation.<br />

Thermally optimized F-Bay is suitable for environments up to 149°F (65°C)<br />

when used with high temperature environment ballasts. T5<br />

systems are warranted for ambient environments up to 149°F<br />

(65°C) for three years and 131°F (55°C) for five years in open<br />

uplight and downlight configurations. T8 systems are<br />

warranted for environments up to 122°F (50°C) for five years.<br />

Die formed reflectors are faceted for 2, 3, 4 and 6 lamp configurations with<br />

two optical distributions medium and wide. Medium beam optical modules<br />

utilize 95% specular Miro 4 substrate while the wide distribution utilizes a<br />

high performance 95% reflective polyester powder coated finish.<br />

No internal fixture<br />

access required for<br />

installation or<br />

disconnecting power<br />

Integral occupancy sensor available and provides<br />

from 600 sq. ft. (MS) up to 1250 sq. ft. (MSO) of<br />

coverage in a maximum mounting height of 40'.<br />

Cooper Lighting’s F-Bay Modular Power <strong>Supply</strong> option allows external fixture access for safe and easy servicing. There is no need to<br />

remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power <strong>Supply</strong>. Access to the individual fixture’s power supply<br />

allows servicing without turning off all the fixtures disrupting occupants. F-Bay Modular Power <strong>Supply</strong> is a time saver in installation –<br />

simply plug & power.<br />

1 2<br />

Modular Motion Sensor Option supplied<br />

with Mounting Box and Modular<br />

Power <strong>Supply</strong> Receptacle<br />

Code Compliance<br />

• UL/cUL Certified for Make/Break<br />

under load (UL2549)<br />

• Meets NEC requirements for<br />

ballast disconnect (NEC 410.73G)<br />

• Allows for addition of Occupancy<br />

Sensor without hard connections<br />

• Receptacles complete with<br />

insulating/dust cap


Shielding Options<br />

Prismatic or clear acrylic lens & steel door frame Optional<br />

gasketed door available<br />

Mounting Accessories<br />

TCB=Top Connector Box<br />

HB-SPS=Single Point Cable Kit<br />

FH-1=Fixture Hook 2-1/2"<br />

(must be used with TCB)<br />

HB-SPS=Two Point<br />

Suspension<br />

Thermal Optimization<br />

To optimize luminaire performance, HB/2HB series<br />

offers a variety of lamp and shielding options.<br />

Use the Thermal Optimization chart to determine<br />

the options that are appropriate for the ambient<br />

environments in which they will be installed.<br />

System Performance<br />

Mounting<br />

Height<br />

40'<br />

Energy<br />

Savings<br />

30'<br />

20'<br />

10'<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

250W MH 250W HPS<br />

66%<br />

8%<br />

-20%<br />

66%<br />

Wireguard w/acrylic lens and steel door frame<br />

FL-1=Fixture Loop 2-1/2"<br />

(must be used with TCB)<br />

250W MH 250W HPS<br />

50%<br />

31%<br />

HB-332-EB8/PLUS HB432UPL<br />

or<br />

HB432PSUPL<br />

65.6°C/150°F<br />

57.2°C/135°F<br />

48.9°C/120°F<br />

40.6°C/105°F<br />

32.2°C/90°F<br />

23.9°C/75°F<br />

15.6°C/60°F<br />

7.2°C/45°F<br />

-1°C/30°F<br />

-9.4°C/15°F<br />

-17.8°C/0°F<br />

-15°F<br />

51%<br />

10%<br />

RH-1=Retrofit Hanger SC-_-_=Stem Sets (fixed,<br />

(must be used with TCB) Swivel or Adjustable<br />

SCF=Fixed<br />

SCA=Adjustable<br />

SCS=Swivel<br />

Vented<br />

w/Uplight<br />

T8 T5<br />

% light gain/light loss utilize S/P adjusted lumens.<br />

250W MH 250W HPS<br />

38%<br />

35%<br />

39%<br />

16%<br />

Unvented<br />

wo/Uplight<br />

Lensed<br />

Luminaire<br />

Vented<br />

w/Uplight<br />

Heavy duty stock wireguard (Ideal for gymnasium applications)<br />

AYC-Mounting chain set<br />

(not for use in gymnasiums<br />

or similar recreational<br />

facilities)<br />

Unvented<br />

wo/Uplight<br />

Lensed<br />

Luminaire<br />

Operating at approximately 90% or above of rated output<br />

Vented<br />

w/Uplight<br />

T8 T5HO<br />

T5HO Amalgam<br />

HB 2HB<br />

400W MH 400W HPS<br />

50%<br />

17%<br />

HB-354T5-EBT1 HB454T5UPL<br />

or<br />

HB454T5UPL<br />

-4%<br />

51%<br />

400W MH 400W HPS<br />

51%<br />

20%<br />

2HB632UPL<br />

or<br />

2HB632PSUPL<br />

0%<br />

Y=Mounting Toggle and 10'<br />

or 25' cable<br />

52%<br />

400W MH 400W HPS<br />

24%<br />

44%<br />

2HB654T5UPL<br />

or<br />

2HB654T5UPL<br />

T8 T5<br />

25%<br />

30%<br />

10


11<br />

2HB HIGH-BAY INDUSTRIAL LUMINAIRE<br />

Ordering Information Sample Number: 2HB-632-A-UNV-EB82/PLUS-UPL-U<br />

Width<br />

2=24"<br />

Series<br />

HB=High Bay<br />

Mounting Arrangement<br />

Blank=Stand Alone<br />

R=Continuous Row Mount<br />

No of Lamps<br />

6=6 Lamps<br />

Lamp Type<br />

32=32W T8 Lamps (48")<br />

28T5=28W T5 Lamps (48")<br />

54T5=54W T5HO Lamps (48")<br />

Distribution<br />

Blank=Medium (Specular Aluminum)<br />

G=Wide (High Reflectance White)<br />

Shielding (12)<br />

Blank=None<br />

A=Prismatic Acrylic Lens & Door Frame<br />

WG=Wireguard & Door Frame<br />

A/WG=Acrylic Lens, Wireguard & Door Frame<br />

CL=Clear Acrylic Lens & Door Frame<br />

CL/WG=Clear Lens, Wireguard & Door Frame<br />

CL/DWG=Clear Lens, Drop Wireguard & Door Frame<br />

DWG=Drop Wireguard & Door Frame<br />

A/DWG=Acrylic Lens, Drop Wireguard & Door Frame<br />

Family<br />

2HB<br />

No of Lamps<br />

6=6 Lamps<br />

Lamp Type<br />

32=32W T8 Lamps (48")<br />

54=54W T5HO Lamps (48")<br />

NOTES: (13) Recommended when utilizing Motion<br />

Sensor option (14) Requires use of Modular cord<br />

and plug accessories (15) High lumen (3100 initial)<br />

4100K T8 lamps supplied<br />

Dimensions<br />

4-3/4"<br />

[121mm]<br />

X=3-1/2"<br />

[89mm]<br />

NOTES: (1) Requires use of MC or MPC cord accessories, specify voltage for plugs (2) Voltage must be specified when ordered with plugs,<br />

motion or emergency ballasts (3) EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C) in open uplight<br />

configuration (4) ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration<br />

(5) Specify voltage (6) For use with Top Connector Box options See accessories (7) 2 lamp ballast configurations only in UNC versions<br />

(8) EHT/HT5/HCT5 ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens<br />

option (9) Cannot be combined with cord or cord & plug option See PI ordering information below (10) Not for use in high abuse applications<br />

such as gymnasiums (11) For use with T8 system with a maximum of two ballasts (including EM ballast) (12) Lensed 6-lamp T5HO luminaires<br />

must use High Ambient ballast option (EHT)<br />

Quick Ship Ordering Information Sample Number: 2HB632PS-MP-UPL-L5<br />

Quick Ship orders ship in 5 days in order quantities not to exceed 200 pieces<br />

NOTE: Orders received after noon are entered on the following day<br />

X X X X X<br />

24" [610mm]<br />

Voltage (2)<br />

UNV=Universal 120/277<br />

Voltage<br />

UNC=Universal 347/480<br />

Voltage<br />

120V=120 Volt<br />

277V=277 Volt<br />

347V=347 Volt<br />

480V=480 Volt<br />

Options<br />

Lamps Installed<br />

L8830=T8 Lamp, 85CRI 3000K<br />

L8835=T8 Lamp, 85CRI 3500K<br />

L8841=T8 Lamp, 85CRI 4100K<br />

L8850=T8 Lamp, 85CRI 5000K<br />

L5830=T5 Lamp, 85CRI 3000K<br />

L5835=T5 Lamp, 85CRI 3500K<br />

L5841=T5 Lamp, 85CRI 4100K<br />

L5850=T5 Lamp, 85CRI 5000K<br />

GL=Single Element Fuse<br />

GM=Double Element Fuse<br />

EL=Emergency Installed (2)<br />

(see table on pg 36)<br />

Ballast Type<br />

T5HO Systems<br />

T5=(2) 120/277V 4/2 Lamp T5 Electronic<br />

Program Rapid Start (13)<br />

HT5=(2) 120/277V 4/2 Lamp T5 High<br />

Ambient Electronic Program Rapid Start (8)<br />

HCT5=(2) 347/480V 2 Lamp T5 High<br />

Ambient Electronic Program Rapid Start (8)<br />

T8 Systems (4)<br />

Blank=(2) 120/277V 4/2 Lamp T8 Instant Start<br />

Electronic High Ballast Factor >1 15<br />

PS=(2) 120/277V 4/2 Lamp T8 Electronic<br />

Program Rapid Start High Ballast Factor >1 15 (13)<br />

Power Receptacle<br />

Blank=Standard Wiring to Access Plate<br />

MP=Modular Power Receptacle (14)<br />

2HB Lamp Configurations Dimensions<br />

for Top View<br />

6-Lamp T5/T8<br />

24"<br />

[610mm]<br />

Ballast Type<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start (4)<br />

Total Harmonic Distortion < 10%<br />

EB8 /PLUS= T8 Electronic Instant Start (4)<br />

No of Ballast<br />

2 or 3<br />

No of<br />

Ballast<br />

2 or 3<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

ER8 =T8 Electronic Program Rapid Start (4)<br />

Total Harmonic Distortion < 10%<br />

ER8 /PLUS= T8 Electronic Program Start (4)<br />

No of Ballast<br />

2 or 3<br />

No of<br />

Ballast<br />

2 or 3<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

T5 Systems<br />

EBT =T5 Linear Electronic Program Rapid Start (3)<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

2 or 3<br />

EHT =T5 Linear Electronic Start High Ambient<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

2 or 3<br />

DIM=Dimming<br />

Access Plate Opening<br />

Includes V Hangers for<br />

rapid installation<br />

Optional Uplight<br />

Blank=No Uplight<br />

UPL=Uplight<br />

48" [1219mm]<br />

(7) (8) (12)<br />

Optional Lamping<br />

Blank=No Lamps<br />

L4=Lamps Installed 80+CRI 4100K (15)<br />

L5=Lamps Installed 80+CRI 5000K<br />

Mounting for<br />

Top Connector Box<br />

Options<br />

Packaging<br />

NUA=No Uplight Apertures U=Unit Pack<br />

In Housing (Cannot be PAL=Palletized<br />

combined w/UPL)<br />

Out of Carton<br />

UPL=Uplight Apertures PALC=Palletized<br />

PI/CPI=Plug-In (1, 2 or 3) In Carton<br />

(9)<br />

see pg 40<br />

TILW=Tandem Inline Wiring<br />

MWS=Modular Wiring System<br />

MS=Aisle Coverage Motion Sensor (5)<br />

MSO=360° Coverage Motion Sensor (5)<br />

C3=3' Power Cord<br />

C6=6' Power Cord<br />

G2=Gasketed Door (Requires Selection of<br />

Lensed Door Frame)<br />

(1) (2)<br />

MP=Modular Power Receptacle<br />

PC3-=3' Power Cord & Plug (Specify Voltage)<br />

PC6-=6' Power Cord & Plug (Specify Voltage)<br />

TAP=Top Access Plate (11)<br />

TCBP=Top Connector Box Plate (6)<br />

Accessories (order separately)<br />

AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets<br />

w/S-Hooks (10)<br />

TCB=Top Connector Box<br />

RH-1=Retrofit Hanger<br />

FH-1=Fixture Hook<br />

FL-1=Fixture Loop<br />

HB-SPS=Single Point Cable Kit (13" Drop Length)<br />

GRIPPLE-Y- =Y Mounting Toggle, #2 Cable<br />

(Specify 10' or 30')<br />

MC3=3' Modular Power Cord<br />

MPC3=3' Modular Power Cord & Plug (Specify<br />

Voltage)<br />

MC6=6' Modular Power Cord<br />

MPC6=6' Modular Power Cord & Plug (Specify<br />

Voltage)<br />

MMS-CPD1200H=Aisle Motion Sensor, Box,<br />

Modular Power Receptacle (120/277V)<br />

MMS-CPD500H=360° Motion Sensor, Box,<br />

Modular Power Receptacle (120/277V)<br />

SWG/2HB-4FT-B=Heavy Duty Wireguard (2HB)<br />

Door Frames (for Field Installation) (12)<br />

2HB-4-A-W/FRM PK=Prismatic Acrylic Lens &<br />

Frame (2HB)<br />

2HB-FRM/CL PK=Clear Acrylic Lens & Frame (2HB)<br />

2HB-FRM/WG PK=Wireguard & Frame (2HB)<br />

2HB-FRM/CL/WG PK=Clear Acrylic Lens, Frame<br />

and Wireguard (2HB)<br />

2HB-FRM/LENS/DROPWG PK=Drop Wireguard,<br />

Prismatic Lens and Frame (2HB)<br />

2HB-FRM/CL/DROPWG PK=Drop Wireguard,<br />

Clear Acrylic Lens and Door Frame (2HB)<br />

2HB-FRM/LENS/DROPWG PK=Drop Wireguard,<br />

Prismatic Acrylic Lens and Door Frame (2HB)<br />

2HB-FRM/DROPWG PK=Drop Wireguard and<br />

Door Frame (2HB)<br />

Quick Ship Accessories (order separately)<br />

MC3=3' Modular Power Cord<br />

MC6=6' Modular Power Cord<br />

MPC6=6' Modular Power Cord & Plug (Specify Voltage)<br />

MPC3=3' Modular Power Cord & Plug (Specify Voltage)<br />

MMS-CPD1200H=Aisle Motion Sensor, Box, Modular Power Receptacle (120/277V)<br />

MMS-CPD500H=360° Motion Sensor, Box, Modular Power Receptacle (120/277V)<br />

11/16"<br />

[18mm] K O<br />

17/64"<br />

Diameter<br />

Hole<br />

2-1/4" [58mm]<br />

3-1/2" [89mm]


Photometrics<br />

System Performance Table<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

2HB-654T5-G-UNV-EBT2-UPL<br />

Electronic Ballasts<br />

(6) 54W T5 lamps 26400 lumens<br />

Spacing criterion: (II) 1 3 x mounting<br />

height, (⊥) 1 4 x mounting height<br />

Efficiency 92%<br />

Test Report: 09312<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

2HB-632-G-UNV-EB82-UPL<br />

(2) Electronic Ballasts<br />

(6) 32W T8 lamps 17100 lumens<br />

Spacing criterion: (II) 1 3 x mounting<br />

height, (⊥) 1 4 x mounting height<br />

Efficiency 92 1%<br />

Test Report: 09308<br />

Illuminance Estimator<br />

108 108 108 108 99 99 99 93 93 93<br />

98 93 89 85 85 82 79 81 78 76<br />

88 80 74 68 74 69 64 70 66 62<br />

80 70 62 56 64 58 53 61 56 52<br />

73 62 53 47 57 50 45 54 48 44<br />

67 55 46 40 51 44 39 48 42 38<br />

62 49 41 35 46 39 34 44 37 33<br />

57 45 36 31 41 35 30 40 33 29<br />

53 41 33 27 38 31 26 36 30 26<br />

50 37 29 24 35 28 24 33 27 23<br />

46 34 27 22 32 26 21 31 25 21<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30<br />

0-40<br />

0-60<br />

0-90<br />

0-180<br />

5567 21 1 22 9<br />

9168 34 7 37 8<br />

16767 63 5 69 1<br />

22592 85 6 93 1<br />

24276 92 0 100 0<br />

108 108 108 108 98 98 98 93 93 93<br />

98 93 89 86 85 82 79 80 78 76<br />

89 81 74 69 74 69 65 70 66 62<br />

80 70 63 57 65 59 54 61 56 52<br />

73 62 54 48 57 51 45 54 49 44<br />

67 55 47 41 55 44 39 48 43 38<br />

62 50 41 35 46 39 34 44 38 33<br />

57 45 37 31 42 35 30 40 34 29<br />

53 41 33 27 38 31 27 36 30 26<br />

50 37 30 25 35 28 24 33 28 23<br />

47 34 27 22 32 26 22 31 25 21<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 3635 21 3 23 1<br />

0-40 6006 35 1 38 1<br />

0-60 10946 64 0 69 5<br />

0-90 14505 84 8 92 1<br />

0-180 15743 92 1 100 0<br />

Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />

Based on 100 ft. x 100 ft. Open Areas<br />

Multiplier<br />

2HB 6L 32W T8 Plus 4L 32W T8 0.67<br />

Mounting<br />

Height<br />

Spacing 15 ft 20 ft 25 ft 30 ft 35 ft<br />

on Center FC LPD FC LPD FC LPD FC LPD FC LPD<br />

15 ft 59 0.6 55 0.6 51 0.6 47 0.6 44 0.6<br />

20 ft 41 0.42 38 0.42 35 0.42 33 0.42 31 0.42<br />

25 ft 26 0.27 24 0.27 23 0.27 21 0.27 20 0.27<br />

30 ft 15 0.15 14 0.15 9 0.15 12 0.15 11 0.15<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

2HB System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens 2 Ratio 3 Perception Lumens 4 Wattage LER 5<br />

2HB632-EB81/PLUS 6 3100 94% 89% 1.15 17895 1.95 1.40 24989 221 $2.77 116<br />

2HB654T5 or 2HB654T5-EHT 6 5000 93% 93% 1.00 25919 1.90 1.38 35727 346 $3.34 96<br />

Comparison System<br />

400W Metal Halide High Bay 1 36000 58% 78% 1 16307 1.50 1.22 19972 455 $9.33 34<br />

400W High Pressure Sodium High Bay 1 50000 81% 78% 1 31631 0.62 0.79 24906 464 $7.63 42<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

2HB-654T5-UNV-EBT2-UPL<br />

(2) Electronic Ballasts<br />

(6) F54T5/HO 830 54W lamps 4400 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 0 x mounting height<br />

Efficiency 95 7%<br />

Test Report: 09309<br />

113 113 113 113 103 103103 98 98 98<br />

103 99 95 91 91 88 85 86 84 82<br />

94 86 80 75 80 75 71 76 72 68<br />

86 76 69 63 71 65 60 67 63 58<br />

79 68 60 54 63 57 52 61 55 51<br />

73 61 53 47 57 51 45 55 49 44<br />

68 56 47 41 52 45 40 50 44 39<br />

63 51 43 37 48 41 36 46 40 35<br />

59 46 39 33 44 37 33 42 36 32<br />

55 43 35 30 41 34 30 39 33 29<br />

52 40 32 28 38 31 27 37 31 27<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 7884 29 9 31 2<br />

0-40 11985 45 4 47 5<br />

0-60 18923 71 7 74 9<br />

0-90 23788 90 1 94 2<br />

0-180 25251 95 7 100 0<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

2HB-632-UNV-EB82-UPL<br />

Electronic Ballasts<br />

(6) 32W T8 lamps 17100 lumens<br />

Spacing criterion: (II) 1 3 x mounting<br />

height, (⊥) 1 0 x mounting height<br />

Efficiency 96%<br />

Test Report: 09306<br />

113 113 113 113 103 103 103 98 98 98<br />

103 99 95 91 91 88 85 86 84 82<br />

94 87 80 75 80 75 71 76 72 69<br />

86 77 69 63 71 65 60 68 63 58<br />

79 68 60 54 63 57 52 61 55 51<br />

73 61 53 47 57 51 45 55 49 44<br />

68 56 47 41 52 45 40 50 44 39<br />

63 51 43 37 48 41 36 46 40 35<br />

59 46 39 33 44 37 32 42 36 32<br />

55 43 35 30 41 34 29 39 33 29<br />

52 40 32 28 38 31 27 36 31 27<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 4989 29 2 30 4<br />

0-40 7631 44 6 46 5<br />

0-60 12278 71 8 74 9<br />

0-90 15392 90 0 93 8<br />

0-180 16402 95 9 100 0<br />

Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />

Based on 100 ft. x 100 ft. Open Areas<br />

Multiplier<br />

2HB 6L 54W T5HO w/Uplight 4L 54W T5HO 0.67<br />

Choose the spacing and mounting height to determine the average footcandle and watts per square foot values. Use the multipliers to factor other available<br />

lamp/ballast configurations.<br />

Mounting<br />

Height<br />

Spacing 15 ft 20 ft 25 ft 30 ft 35 ft<br />

on Center FC LPD FC LPD FC LPD FC LPD FC LPD<br />

15 ft 80 1.23 74 1.23 69 1.23 64 1.23 60 1.23<br />

20 ft 55 0.86 51 0.86 48 0.86 45 0.86 42 0.86<br />

25 ft 35 0.55 33 0.55 31 0.55 29 0.55 27 0.55<br />

30 ft 20 0.31 19 0.31 17 0.31 16 0.31 15 0.31<br />

12


13<br />

Dimensions<br />

4-3/4"<br />

[121mm]<br />

X=6-5/16"<br />

[161mm]<br />

4-3/4"<br />

[121mm]<br />

X=2-7/8"<br />

[74mm]<br />

X<br />

15-7/16" [392mm]<br />

X X X<br />

15-7/16" [392mm]<br />

Quick Ship Ordering Information Sample Number: HB454T5-MP-UPL-L5<br />

Quick Ship orders ship in 5 days in order quantities not to exceed 200 pieces<br />

NOTE: Orders received after noon are entered on the following day<br />

2HB Lamp Configurations Dimensions for Top View<br />

2-Lamp T5/T8 3-Lamp T5/T8<br />

4-Lamp T5/T8<br />

HB HIGH-BAY INDUSTRIAL LUMINAIRE<br />

Ordering Information Sample Number: HB-432-A-UNV-EB81<br />

Width<br />

Blank=15"<br />

Series<br />

HB=High Bay<br />

Mounting Arrangement<br />

Blank=Stand Alone<br />

R=Continuous Row Mount<br />

No of Lamps<br />

2=2 Lamps<br />

3=3 Lamps<br />

4=4 Lamps (12)<br />

Lamp Type<br />

32=32W T8 Lamps (48")<br />

28T5=28W T5 Lamps (48")<br />

54T5=54W T5HO Lamps (48")<br />

Distribution<br />

Blank=Medium (Specular Aluminum)<br />

G=Wide (High Reflectance White)<br />

Shielding (12)<br />

Blank=None<br />

A=Prismatic Acrylic Lens & Door Frame<br />

WG=Wireguard & Door Frame<br />

A/WG=Acrylic Lens, Wireguard & Door Frame<br />

CL=Clear Acrylic Lens & Door Frame<br />

CL/WG=Clear Lens, Wireguard & Door Frame<br />

CL/DWG=Clear Lens, Drop Wireguard & Door Frame<br />

DWG=Drop Wireguard & Door Frame<br />

A/DWG=Acrylic Lens, Drop Wireguard & Door Frame<br />

Family<br />

HB<br />

Lamp Qty<br />

4=4 Lamps<br />

Lamp Type<br />

32=32W T8 Lamps (48")<br />

54=54W T5HO Lamps (48")<br />

NOTES: (13) Recommended when utilizing Motion<br />

Sensor option (14) Requires use of Modular cord<br />

and plug accessories (15) High lumen (3100 initial)<br />

lamps supplied 4100K T8 only<br />

NOTES: (1) Requires use of MC or MPC cord accessories, specify voltage for plugs (2) Voltage must be specified when ordered with plugs,<br />

motion or emergency ballasts (3) EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C) in open uplight<br />

configuration (4) ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration<br />

(5) Specify voltage (6) For use with Top Connector Box options See accessories (7) 2 lamp ballast configurations only in UNC versions<br />

(8) EHT/HT5/HCT5 ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less<br />

lens option (9) Cannot be combined with cord or cord & plug See PI ordering information below (10) Not for use in high abuse applications<br />

such as gymnasiums (11) For use with T8 system with a maximum of two ballasts (including Emergency ballast) (12) Lensed 4-lamp T5HO<br />

luminaires must use High Ambient ballast option (EHT)<br />

4-3/4"<br />

[121mm]<br />

X=3-9/16"<br />

[91mm]<br />

Voltage (2)<br />

UNV=Universal 120/277<br />

Voltage<br />

UNC=Universal 347/480<br />

Voltage<br />

120V=120 Volt<br />

277V=277 Volt<br />

347V=347 Volt<br />

480V=480 Volt<br />

Options<br />

Lamps Installed<br />

L8830=T8 Lamp, 85CRI 3000K<br />

L8835=T8 Lamp, 85CRI 3500K<br />

L8841=T8 Lamp, 85CRI 4100K<br />

L8850=T8 Lamp, 85CRI 5000K<br />

L5830=T5 Lamp, 85CRI 3000K<br />

L5835=T5 Lamp, 85CRI 3500K<br />

L5841=T5 Lamp, 85CRI 4100K<br />

L5850=T5 Lamp, 85CRI 5000K<br />

GL=Single Element Fuse<br />

GM=Double Element Fuse<br />

EL=Emergency Installed<br />

(see table on pg 36)<br />

Ballast Type<br />

T5HO Systems<br />

T5=(1) 120/277V 4 Lamp T5 Electronic Program<br />

Rapid Start (13)<br />

HT5=(1) 120/277V 4 Lamp T5 High Ambient<br />

Electronic Program Rapid Start (8)<br />

HCT5=(1) 347/480V 2 Lamp T5 High Ambient<br />

Electronic Program Rapid Start (8)<br />

T8 Systems (4)<br />

Blank=(1) 120/277V 4 Lamp T8 Instant Start<br />

Electronic High Ballast Factor >1 15<br />

PS=(1) 120/277V 4 Lamp T8 Electronic Program<br />

Rapid Start High Ballast Factor >1 15 (13)<br />

X X<br />

15-7/16" [392mm]<br />

15-7/16"<br />

[392mm]<br />

Ballast Type<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start (4)<br />

Total Harmonic Distortion < 10%<br />

EB8 /PLUS= T8 Electronic Instant Start (4)<br />

No of Ballast<br />

1, 2 or 3<br />

No of<br />

Ballast<br />

1, 2 or 3<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

ER8 =T8 Electronic Program Rapid Start (4)<br />

Total Harmonic Distortion < 10%<br />

ER8 /PLUS= T8 Electronic Program Start (4)<br />

No of Ballast<br />

1, 2 or 3<br />

No of<br />

Ballast<br />

1, 2 or 3<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

T5 Systems<br />

EBT =T5 Linear Electronic Program Rapid Start (3)<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1, 2 or 3<br />

EHT =T5 Linear Electronic Start High Ambient<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1, 2 or 3<br />

DIM=Dimming<br />

Power Receptacle<br />

Blank=Standard Wiring<br />

to Access Plate<br />

MP=Modular Power<br />

Receptacle (14)<br />

Optional Uplight<br />

Blank=No Uplight<br />

UPL=Uplight<br />

Includes V Hangers for<br />

rapid installation<br />

Optional Lamping<br />

Blank=No Lamps<br />

L4=Lamps Installed 80+CRI 4100K (15)<br />

L5=Lamps Installed 80+CRI 5000K<br />

Access Plate Opening<br />

48" [1219mm]<br />

(7) (8) (12)<br />

Mounting for<br />

Top Connector Box<br />

Options<br />

NUA=No Uplight Apertures<br />

In Housing (Cannot be<br />

combined w/UPL)<br />

UPL=Uplight Apertures<br />

PI/CPI=Plug-In (1, 2 or 3) (9)<br />

see pg 40<br />

TILW=Tandem Inline Wiring<br />

MWS=Modular Wiring System<br />

MS=Aisle Coverage Motion Sensor (5)<br />

MSO=360° Coverage Motion Sensor (5)<br />

C3=3' Power Cord<br />

C6=6' Power Cord<br />

G2=Gasketed Door (Requires Selection of<br />

Lensed Door Frame)<br />

(1) (2)<br />

MP=Modular Power Receptacle<br />

PC3-=3' Power Cord & Plug (Specify Voltage)<br />

PC6-=6' Power Cord & Plug (Specify Voltage)<br />

TAP=Top Access Plate (11)<br />

TCBP=Top Connector Box Plate (6)<br />

Packaging<br />

U=Unit Pack<br />

PAL=Palletized<br />

Out of Carton<br />

PALC=Job Pack<br />

In Carton<br />

Accessories (order separately)<br />

AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets<br />

w/S-Hooks (10)<br />

TCB=Top Connector Box<br />

RH-1=Retrofit Hanger<br />

FH-1=Fixture Hook<br />

FL-1=Fixture Loop<br />

HB-SPS=Single Point Cable Kit (13" Drop Length)<br />

GRIPPLE-Y- =Y Mounting Toggle, #2 Cable<br />

(Specify 10' or 30')<br />

MC3=3' Modular Power Cord<br />

MPC3=3' Modular Power Cord & Plug (Specify<br />

Voltage)<br />

MC6=6' Modular Power Cord<br />

MPC6=6' Modular Power Cord & Plug (Specify<br />

Voltage)<br />

MMS-CPD1200H=Aisle Motion Sensor, Box,<br />

Modular Power Receptacle (120/277V)<br />

MMS-CPD500H=360° Motion Sensor, Box,<br />

Modular Power Receptacle (120/277V)<br />

SWG/HB-4FT-B=Heavy Duty Wireguard (HB)<br />

Door Frames (for Field Installation) (12)<br />

HB-FRM/LENS=Prismatic Acrylic Lens & Frame (HB)<br />

HB-FRM/CL PK=Clear Acrylic Lens & Frame (HB)<br />

HB-FRM/WG PK=Wireguard & Frame (HB)<br />

HB-FRM/LENS/WG PK=Prismatic Acrylic Lens,<br />

Frame and Wireguard (HB)<br />

HB-FRM/DROPWG PK=Frame and Drop<br />

Wireguard for HB<br />

Quick Ship Accessories (order separately)<br />

MC3=3' Modular Power Cord<br />

MC6=6' Modular Power Cord<br />

MPC6=6' Modular Power Cord & Plug (Specify Voltage)<br />

MPC3=3' Modular Power Cord & Plug (Specify Voltage)<br />

MMS-CPD1200H=Aisle Motion Sensor, Box, Modular Power<br />

Receptacle (120/277V)<br />

MMS-CPD500H=360° Motion Sensor, Box, Modular Power<br />

Receptacle (120/277V)<br />

11/16" [18mm] K O<br />

17/64"<br />

Diameter<br />

Hole<br />

2-1/4" [58mm]<br />

3-1/2" [89mm]


Photometrics<br />

HB-254T5-UNV-EBT1-UPL<br />

Electronic Ballasts<br />

(2) FP54/835/HO lamps 4400 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 0 9 x mounting height<br />

Efficiency 95 5%<br />

Test Report: HB254T5UPL IES<br />

HB-454T5-G-UNV-EBT2-UPL<br />

Electronic Ballasts<br />

(4) F54T5/830 HO lamps 4400 lumens<br />

Spacing criterion: (II) 1 3 x mounting<br />

height, (⊥) 1 3 x mounting height<br />

Efficiency 82 1%<br />

Test Report: HB454T5GUPL IES<br />

Illuminance Estimator<br />

Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />

Based on 100 ft. x 100 ft. Open Areas<br />

Multiplier<br />

2L 54W T5HO 0.50<br />

HB 4L 54W T5HO 3L 54W T5HO 0.75<br />

Mounting<br />

Height<br />

Spacing 15 ft 20 ft 25 ft 30 ft 35 ft<br />

on Center FC LPD FC LPD FC LPD FC LPD FC LPD<br />

15 ft 51 0.8 47 0.8 44 0.8 41 0.8 38 0.8<br />

20 ft 34 0.55 33 0.55 31 0.55 29 0.55 27 0.55<br />

25 ft 23 0.35 21 0.35 20 0.35 18 0.35 17 0.35<br />

30 ft 13 0.2 12 0.2 11 0.2 10 0.2 10 0.2<br />

System Performance Table<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

112 112 112 112 101 101 101 95 95 95<br />

103 99 96 93 91 88 86 86 84 82<br />

95 88 83 78 81 77 73 77 73 70<br />

88 79 72 67 73 67 63 69 65 61<br />

81 71 63 58 66 60 55 62 57 53<br />

75 64 56 51 60 53 49 57 52 47<br />

70 58 51 45 54 48 44 52 47 42<br />

65 53 46 41 50 44 39 48 42 38<br />

61 49 42 37 46 40 36 44 39 35<br />

57 46 38 33 43 37 33 41 36 32<br />

54 42 35 31 40 34 30 39 33 29<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 3015 34 3 35 9<br />

0-40 4377 49 7 52 1<br />

0-60 6513 74 0 77 5<br />

0-90 7608 86 5 90 5<br />

0-180 8408 95 5 100 0<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

97 97 97 97 88 88 88 84 84 84<br />

89 85 82 79 78 76 74 74 72 70<br />

81 74 69 64 69 65 61 65 62 59<br />

74 65 59 54 61 56 51 58 53 50<br />

67 58 51 45 54 48 44 51 46 43<br />

61 51 44 38 47 41 37 45 40 36<br />

56 45 38 33 42 36 32 40 35 31<br />

52 41 33 28 38 32 28 36 31 27<br />

48 36 29 24 34 28 24 33 27 23<br />

44 33 26 21 31 25 20 29 24 20<br />

41 30 23 18 28 22 18 27 21 18<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 3436 19 5 23 8<br />

0-40 5677 32 3 39 3<br />

0-60 10418 59 2 72 1<br />

0-90 13546 77 0 93 7<br />

0-180 14453 82 1 100 0<br />

HB-354T5-UNV-EBT2-UPL<br />

Electronic Ballasts<br />

(3) FP54/835/HO lamps 4400 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 3 x mounting height<br />

Efficiency 92 9%<br />

Test Report: HB354T5UPL IES<br />

HB-454T5-UNV-EBT2-UPL<br />

Electronic Ballasts<br />

(4) F54T5/835 HO lamps 4400 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 0 8 x mounting height<br />

Efficiency 93 6%<br />

Test Report: HB454T5UPL IES<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

108 108 108 108 98 98 98 92 92 92<br />

100 96 92 89 87 85 83 82 80 78<br />

92 85 79 74 77 73 69 73 70 66<br />

84 75 68 62 69 63 59 65 61 57<br />

77 67 59 53 62 56 51 58 53 49<br />

71 60 52 46 55 49 44 53 47 43<br />

66 54 46 41 50 44 39 48 42 38<br />

61 49 42 36 46 39 35 44 38 34<br />

57 45 38 32 42 36 31 40 35 31<br />

53 41 34 29 39 33 28 37 32 28<br />

50 38 31 27 36 30 26 34 29 25<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 3567 27 0 29 1<br />

0-40 5750 43 6 46 9<br />

0-60 9326 70 7 76 1<br />

0-90 11066 83 8 90 3<br />

0-180 12260 92 9 100 0<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

110 110 110 110 101 101101 95 95 95<br />

102 98 94 91 90 88 85 86 83 82<br />

93 86 81 76 80 76 72 76 73 70<br />

86 77 70 65 72 66 62 68 64 60<br />

79 69 61 56 64 58 54 62 57 52<br />

73 62 55 49 58 52 47 56 51 46<br />

68 57 49 43 53 47 42 51 46 41<br />

64 52 44 39 49 43 38 47 41 37<br />

59 48 40 35 45 39 34 44 38 34<br />

56 44 37 32 42 36 31 40 35 31<br />

52 41 34 29 39 33 29 38 32 28<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 5656 32 1 34 3<br />

0-40 8411 47 8 51 0<br />

0-60 13046 74 1 79 2<br />

0-90 15460 87 8 93 8<br />

0-180 16480 93 6 100 0<br />

Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />

Based on 100 ft. x 100 ft. Open Areas<br />

Multiplier<br />

2L 32W T8 0.50<br />

HB 4L 32W T8 PLUS 3L 32W T8 0.75<br />

Mounting<br />

Height<br />

Spacing 15 ft 20 ft 25 ft 30 ft 35 ft<br />

on Center FC LPD FC LPD FC LPD FC LPD FC LPD<br />

15 ft 37 0.39 34 0.39 32 0.39 30 0.39 28 0.39<br />

20 ft 26 0.27 24 0.27 22 0.27 21 0.27 19 0.27<br />

25 ft 17 0.17 15 0.17 14 0.17 13 0.17 12 0.17<br />

30 ft 9 0.1 9 0.1 8 0.1 7 0.1 7 0.1<br />

Choose the spacing and mounting height to determine the average footcandle and watts per square foot values. Use the multipliers to factor other available<br />

lamp/ballast configurations.<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

HB System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens 2 Ratio 3 Perception Lumens 4 Wattage LER 5<br />

HB-332-EB8/PLUS 3 3100 94% 89% 1.15 8947 1.95 1.40 12494 101 $2.53 127<br />

HB432 or HB432PS-EB81/PLUS 4 3100 94% 89% 1.15 11930 1.95 1.40 16659 147 $2.76 116<br />

HB-354T5-EBT1 3 5000 93% 93% 1.00 12960 1.90 1.38 17864 182 $3.51 91<br />

HB454T5 or HB454T5-EHT 4 5000 93% 94% 1.00 17410 1.90 1.38 23997 229 $3.26 98<br />

Comparison System<br />

250W Metal Halide High Bay 1 20800 58% 78% 1.00 9422 1.50 1.22 11540 295 $10.47 31<br />

250W High Pressure Sodium High Bay 1 30000 81% 78% 1.00 18978 0.62 0.79 14944 300 $8.23 39<br />

400W Metal Halide High Bay 1 36000 58% 78% 1.00 16307 1.50 1.22 19972 455 $9.33 34<br />

400W High Pressure Sodium High Bay 1 50000 81% 78% 1.00 31631 0.62 0.79 24906 464 $7.63 42<br />

14


15<br />

I5/I8 HIGH-BAY INDUSTRIAL LUMINAIRE<br />

Specification grade full body housing, end plates and socket tracks<br />

are die formed 20 gauge cold rolled steel in 4' or 8' lengths.<br />

Surface or suspension mounting (cable, chain,<br />

pendant mount or top connector box).<br />

Optional uplight apertures<br />

(approximately 8% uplight)<br />

Latched retention of<br />

optics (safety leader<br />

restraints) allows for<br />

easy access.<br />

Narrow 11" I5 and I8 housing allows<br />

mounting within 12" horizontally from the<br />

nearest edge of the sprinkler detector.<br />

Optional modular power receptacle meets UL2459 and<br />

NEC 410.73 and is UL/cUL rated for make and<br />

break under load from outside the luminaire<br />

to speed maintenance.<br />

Modular F-Bay Power <strong>Supply</strong><br />

1. Modular Power <strong>Supply</strong> Receptacle supplied<br />

mounted into fixture Access Plate<br />

2. Modular Power Cord & Plugs in 120, 277, 347,<br />

& 480V configurations for easy plug & power<br />

into existing supply<br />

No internal fixture<br />

access required for<br />

installation or<br />

disconnecting power<br />

Thermally optimized F-Bay is suitable for environments<br />

up to 149°F (65°C) when used with high temperature<br />

environment ballasts. T5 systems are warranted for<br />

ambient environments up to 149°F (65°C) for three<br />

years and 131°F (55°C) for five years in open uplight<br />

configurations. T8 systems are warranted for environments<br />

up to 122°F (50°C) for five years.<br />

Optical modules are fully enclosed inside<br />

housing to protect against damage.<br />

Die formed reflectors are faceted for 2, 3, 4, 6 and 8 lamp tandem configurations<br />

with two optical distributions medium and wide. Medium beam optical<br />

modules utilize 95% specular Miro 4 substrate while the wide distribution utilizes<br />

a high performance 95% reflective polyester powder coated finish.<br />

Integral occupancy sensor available and provides<br />

from 600 sq. ft. (MS) up to 1250 sq. ft. (MSO) of<br />

coverage at a maximum mounting height of 40'.<br />

Cooper Lighting’s F-Bay Modular Power <strong>Supply</strong> option allows external fixture access for safe and easy servicing. There is no need to<br />

remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power <strong>Supply</strong>. Access to the individual fixture’s power supply<br />

allows servicing without turning off all the fixtures disrupting occupants. F-Bay Modular Power <strong>Supply</strong> is a time saver in installation –<br />

simply plug & power.<br />

1 2<br />

Modular Motion Sensor Option supplied<br />

with Mounting Box and Modular<br />

Power <strong>Supply</strong> Receptacle<br />

Code Compliance<br />

• UL/cUL Certified for Make/Break<br />

under load (UL2549)<br />

• Meets NEC requirements for<br />

ballast disconnect (NEC 410.73G)<br />

• Allows for addition of Occupancy<br />

Sensor without hard connections<br />

• Receptacles complete with<br />

insulating/dust cap


Shielding Options<br />

Frosted acrylic or clear lens & frame (use<br />

with general distribution reflector, I5 only)<br />

Mounting Accessories<br />

TCB=Top Connector Box<br />

Row Mount<br />

System Performance<br />

FH-1=Fixture Hook 2-1/2"<br />

(must be used with TCB)<br />

Heavy duty wireguard finished in white Can be used<br />

alone or in combination with other shielding<br />

FL-1=Fixture Loop 2-1/2"<br />

(must be used with TCB)<br />

RH-1=Retrofit Hanger<br />

(must be used with TCB)<br />

End plates provided with the “Quick-Tab” joining system for ease of row mounting Blank end plates<br />

provided for row ends<br />

Dimensions<br />

Mounting<br />

Height<br />

40'<br />

Energy<br />

Savings<br />

30'<br />

20'<br />

10'<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

250W MH 250W HPS<br />

38%<br />

36 %<br />

I5355<br />

39%<br />

17%<br />

400W MH 400W HPS<br />

50%<br />

16%<br />

I5455<br />

-4%<br />

52%<br />

Thin blade white baffle w/23° longitudinal<br />

shielding<br />

66%<br />

13% -13%<br />

AYC-Mounting<br />

chain set<br />

I5/I8 Lamp Configurations Dimensions for Top View<br />

4-15/16"<br />

[126mm]<br />

2-Lamp<br />

4-5/8"<br />

[118mm]<br />

11" [280mm]<br />

4-15/16"<br />

[126mm]<br />

X=2-3/4"<br />

[70mm]<br />

3-Lamp 4-Lamp<br />

X X<br />

11" [280mm]<br />

4-15/16"<br />

[126mm]<br />

X=2-11/32"<br />

[60mm]<br />

X X X<br />

11" [280mm]<br />

11"<br />

[280mm]<br />

11/16" [18mm] K.O.<br />

for Cable or Pendant Mounting<br />

I5 8TI5<br />

I8<br />

250W MH 250W HPS<br />

78%<br />

I8-332-EB81/PLUS<br />

I5: 46" [1168mm]<br />

92" [2337mm]<br />

T5 T5<br />

T8<br />

% light gain/light loss utilize S/P adjusted lumens.<br />

400W MH 400W HPS<br />

24%<br />

45%<br />

8TI5-354T5-EBT2<br />

25%<br />

31%<br />

1000W MH 1000W HPS<br />

58%<br />

9%<br />

8TI5-454T5-EBT3<br />

SC-_-_=Stem Sets (fixed,<br />

Swivel or Adjustable<br />

SCF=Fixed<br />

SCA=Adjustable<br />

SCS=Swivel<br />

58%<br />

26%<br />

Asymmetric directional louver can be oriented<br />

in either direction for flexibility<br />

LOOP=Loop Hanger,<br />

#2 Cable<br />

I8: 48" [1219mm]<br />

96" [2438mm]<br />

400W MH 400W HPS<br />

51%<br />

15% -14%<br />

51%<br />

I8-432-EB81/PLUS<br />

TOGGLE=Single<br />

Toggle, #2 Cable<br />

Access Plate<br />

11/16" [18mm] K.O.<br />

for Cable or<br />

Pendant Mounting<br />

2-3/4" [70mm]<br />

8TI8<br />

1000W MH 1000W HPS<br />

58%<br />

9%<br />

T8<br />

58%<br />

26%<br />

8TI8-432-EB83/PLUS<br />

16


17<br />

I5/I8 HIGH-BAY INDUSTRIAL LUMINAIRE<br />

Ordering Information Sample Number: 8TI5-254T5-TBW-120V-EBT1-UPL-U<br />

Length<br />

Blank=4' Length<br />

8T=8' Length<br />

Series<br />

I5=T5 <strong>Industrial</strong><br />

I8=T8 <strong>Industrial</strong><br />

Mounting Arrangement<br />

Blank=Stand Alone<br />

R=Continuous Row Mount<br />

No of Lamps<br />

2=2 Lamps<br />

3=3 Lamps<br />

4=4 Lamps<br />

Lamp Type<br />

28T5=28W T5 Std (4') Lamps<br />

54T5=54W T5HO (4') Lamps<br />

32=32W T8 (4') Lamps<br />

Distribution Optic<br />

Blank=Medium (Specular Aluminum)<br />

G=Wide (High Reflectance White)<br />

Shielding Options<br />

Blank=Open<br />

TBW=Thin White Baffle<br />

FL=Frosted Acrylic Lens & Frame (2)<br />

CL=Clear Acrylic Lens & Door Frame<br />

ASY= Asymmetric Directional Louver (2)<br />

WG=Heavy Duty Wireguard<br />

Stock Catalog Items<br />

I5455=4 lamp, 54W T5HO, Program Rapid Start Ballast,<br />

Top Connector Plate, Uplight, 850 Lamps Installed<br />

I5355=3 lamp, 54W T5HO, Program Rapid Start Ballast,<br />

Top Connector Plate, Uplight, 850 Lamps Installed<br />

System Performance Tables<br />

Voltage (3)<br />

UNV=Universal<br />

120/277 Voltage<br />

UNC=Universal<br />

347/480 Voltage<br />

120V=120 Volt<br />

277V=277 Volt<br />

347V=347 Volt<br />

480V=480 Volt<br />

Options<br />

I5 Lamps Installed<br />

L5830=T5 Lamp, 85CRI 3000K<br />

L5835=T5 Lamp, 85CRI 3500K<br />

L5841=T5 Lamp, 85CRI 4100K<br />

L5850=T5 Lamp, 85CRI 5000K<br />

I8 Lamps Installed<br />

L8830=T8 Lamp, 85CRI 3000K<br />

L8835=T8 Lamp, 85CRI 3500K<br />

L8841=T8 Lamp, 85CRI 4100K<br />

L8850=T8 Lamp, 85CRI 5000K<br />

GL=Single Element Fuse<br />

GM=Double Element Fuse<br />

EL=Emergency Installed (3)<br />

(see table on pg 36)<br />

Ballast Type<br />

T5 Systems<br />

EBT =T5 Linear Electronic Program Rapid Start (4)<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1, 2 or 3<br />

EHT =T5 Linear Electronic Start High Ambient<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1, 2 or 3<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start (5)<br />

ER8 =T8 Electronic Program Rapid Start (5)<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1, 2 or 3<br />

ER8 /PLUS= T8 Electronic Program Start<br />

DIM=Dimming<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

NOTES: (1) Requires use of MC or MPC cord accessories, specify voltage for plugs<br />

(2) Use with wide distribution optic only (3) Voltage must be specified when ordered<br />

with plugs, motion or emergency ballasts (4) EBT ballast systems suitable for operation<br />

in ambient environments up to 104°F (40°C) (5) ER8 and EB8 ballast systems suitable<br />

for operation in ambient environments up to 122°F (50°C) in open uplight configurations<br />

(6) Specify voltage (7) For use with Top Connector Box options See accessories (8) 2 lamp<br />

ballast configurations only in UNC High Ambient versions (9) EHT ballast systems suitable<br />

for ambient environments not to exceed 149°F (65°C) in open uplight configurations<br />

and less lens option (10) TAP option available with a maximum of two ballasts, including<br />

EM battery pack (11) Not for use in gymnasiums or similar recreational facilities<br />

(8) (9)<br />

Total Harmonic Distortion < 10%<br />

EB8 /PLUS= T8 Electronic Instant Start (5)<br />

No of Ballast<br />

1, 2 or 3<br />

High Ballast Factor >1 15<br />

No of Ballast<br />

Total Harmonic Distortion < 10%<br />

1, 2 or 3<br />

No of<br />

Ballast<br />

1, 2 or 3<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

Options<br />

NUA=No Uplight Apertures In Housing<br />

(Cannot be combined w/UPL)<br />

UPL=Uplight Apertures<br />

PI/CPI=Plug-In (1, 2 or 3) See pg 40<br />

TILW=Tandem Inline Wiring<br />

MWS=Modular Wiring System<br />

MS=Aisle Coverage Motion Sensor (6)<br />

MSO=360° Coverage Motion Sensor (6)<br />

C3=3' Power Cord<br />

C6=6' Power Cord<br />

(1) (3)<br />

MP=Modular Power Receptacle<br />

Packaging<br />

U=Unit Pack<br />

PAL=Palletized<br />

Out of Carton<br />

PALC=Palletized<br />

In Carton<br />

PC3-=3' Power Cord & Plug (Specify Voltage)<br />

TAP=Top Access Plate (10)<br />

TCBP=Top Connector Box Plate (7)<br />

Accessories (order separately)<br />

TCB=Top Connector Box<br />

RH-1=Retrofit Hanger<br />

FH-1=Fixture Hook<br />

FL-1=Fixture Loop<br />

SHK=Hook w/ Safety Screw<br />

PC3-=3' Power Cord & Plug (Specify Voltage)<br />

PC6-=6' Power Cord & Plug (Specify Voltage)<br />

AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks (11)<br />

GRIPPLE TOGGLE- =Single Toggle, #2 Cable (Specify 10' or 30')<br />

GRIPPLE LOOP- =Loop Hanger, #2 Cable (Specify 10' or 30')<br />

MC6=6' Modular Power Cord<br />

MPC6=6' Modular Power Cord & Plug (Specify Voltage)<br />

MMS-CPD1200H=Aisle Motion Sensor, Box, Modular<br />

Power Receptacle (120/277V)<br />

MMS-CPD500H=360° Motion Sensor, Box, Modular<br />

Power Receptacle (120/277V)<br />

Door Frames (for Field Installation)<br />

I5-FRM/LENS=Frosted Acrylic Lens & Frame (I5)<br />

I8-FRM/LENS PK=Frosted Acrylic Lens & Frame (I8)<br />

I5-FRM/CL PK=Clear Acrylic Lens & Frame (I5)<br />

I8-FRM/CL PK=Clear Acrylic Lens & Frame (I8)<br />

WG/I5-4FT-B=Heavy Duty Wireguard (I5)<br />

WG/I8-4FT-B=Heavy Duty Wireguard (I8)<br />

90800PPK=Thin White Blade Baffle (I5)<br />

BAFFLE 4FT I8=Thin White Blade Baffle (I8)<br />

90801PPK=Asymmetrical Directional Louver<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

I5 System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens 2 Ratio 3 Perception Lumens 4 Wattage LER 5<br />

I5355 3 5000 93% 94% 1.00 13113 1.90 1.38 18075 182 $3.43 93<br />

I5455 4 5000 93% 93% 1.00 17298 1.90 1.38 23844 229 $3.30 97<br />

8TI5355 6 5000 93% 94% 1.00 26282 1.90 1.38 36227 346 $3.24 99<br />

Comparison System<br />

250W Metal Halide High Bay 1 20800 58% 78% 1.00 9422 1.50 1.22 11540 295 $10.47 31<br />

250W High Pressure Sodium High Bay 1 30000 81% 78% 1.00 18978 0.62 0.79 14944 300 $8.23 39<br />

400W Metal Halide High Bay 1 36000 58% 78% 1.00 16307 1.50 1.22 19972 455 $9.33 34<br />

400W High Pressure Sodium High Bay<br />

8I5 Comparison System<br />

1 50000 81% 78% 1.00 31631 0.62 0.79 24906 464 $7.63 42<br />

8TI5-454T5<br />

Comparison System<br />

8 5000 93% 94% 1.00 35042 1.90 1.38 48303 458 $3.22 99<br />

1000W Metal Halide High Bay 1 102800 45% 78% 1.00 36083 1.50 1.22 44192 1085 $10.07 32<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

I8 System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4 Wattage LER5 I8-332-EB8/PLUS 3 3100 94% 94% 1.15 9450 1.95 1.40 13196 101 $2.27 141<br />

I8-432-EB8/PLUS<br />

Comparison System<br />

4 3100 94% 94% 1.15 12600 1.95 1.40 17595 147 $2.47 129<br />

250W Metal Halide High Bay 1 20800 58% 78% 1.00 9422 1.50 1.22 11540 295 $10.47 31<br />

250W High Pressure Sodium High Bay 1 30000 81% 78% 1.00 18978 0.62 0.79 14944 300 $8.23 39<br />

400W Metal Halide High Bay 1 36000 58% 78% 1.00 16307 1.50 1.22 19972 455 $9.33 34<br />

400W High Pressure Sodium High Bay<br />

8I8 System Comparison<br />

1 50000 81% 78% 1.00 31631 0.62 0.79 24906 464 $7.63 42<br />

8I8-432-EB8/PLUS<br />

Comparison System<br />

8 3100 94% 94% 1.15 25200 1.95 1.40 35190 302 $2.54 126<br />

1000W Metal Halide High Bay 1 102800 45% 78% 1.00 36083 1.50 1.22 44192 1085 $10.07 32<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 5 LER (Luminaire Efficiency Ratio) is an<br />

accepted method of comparing fixture performance


Photometrics<br />

I5-454T5-UNV-EBT2-UPL<br />

(2) Electronic Ballasts<br />

(4) 54W T5 lamps 4400 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 0 8 x mounting height<br />

Efficiency 92 8%<br />

Test Report: 236P118<br />

I5-354T5-UNV-EBT2-UPL<br />

(2) Electronic Ballasts<br />

(3) F54T5/HO/830K lamps 4400 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 0 7 x mounting height<br />

Efficiency 98 2%<br />

Test Report: 236P108<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

109 109 109 109 100 100 100 94 94 94<br />

101 97 94 91 90 87 85 85 83 81<br />

93 87 81 77 80 76 73 76 73 70<br />

86 78 71 66 72 67 63 69 65 61<br />

80 70 63 57 65 60 55 63 58 54<br />

73 63 55 50 59 53 48 56 51 47<br />

68 57 49 44 54 47 43 51 46 42<br />

63 52 44 39 49 43 38 47 41 37<br />

59 47 40 34 44 38 34 43 37 33<br />

54 43 35 30 40 34 30 39 33 29<br />

51 39 32 27 37 31 27 36 30 26<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 5508 31 3 33 7<br />

0-40 8329 47 3 51 0<br />

0-60 12731 72 3 78 0<br />

0-90 15217 86 5 93 2<br />

0-180 16330 92 8 100 0<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

115 115 115 115 105 105 105 99 99 99<br />

107 103 100 97 95 92 90 90 88 86<br />

99 92 86 81 85 81 77 81 77 74<br />

91 83 76 70 77 71 67 73 69 65<br />

85 74 67 61 69 63 59 66 61 57<br />

78 67 59 53 63 56 51 60 55 50<br />

73 61 53 47 57 51 46 55 49 45<br />

68 55 48 42 52 46 41 50 45 40<br />

63 50 43 37 48 41 37 46 40 36<br />

58 46 38 33 44 37 33 42 36 32<br />

54 42 35 30 40 34 29 39 33 29<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 4637 35 1 35 8<br />

0-40 6733 51 0 51 9<br />

0-60 10058 76 2 77 6<br />

0-90 12070 91 4 93 1<br />

0-180 12966 98 2 100 0<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

I8-332-UNV-EB81-UPL<br />

Electronic Ballast<br />

F32T8/TL835 Lamps 3000 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 1 x mounting height<br />

Efficiency 94 1%<br />

Test Report: 236P188C<br />

Illuminance Estimator<br />

110 110 110 110 100 100 100 95 95 95<br />

101 97 93 90 89 86 83 84 82 80<br />

92 85 79 74 78 74 70 74 70 67<br />

85 75 68 62 69 64 59 66 61 57<br />

78 67 59 53 62 56 51 59 54 49<br />

72 60 52 46 56 49 44 53 48 43<br />

66 54 46 41 51 44 39 48 43 38<br />

62 50 42 36 46 40 35 44 39 34<br />

58 45 38 32 43 36 32 42 35 31<br />

54 42 34 29 39 33 29 38 32 28<br />

51 39 32 27 37 30 26 35 30 26<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 2530 28 1 29 9<br />

0-40 3885 43 2 45 9<br />

0-60 6299 70 0 74 4<br />

0-90 7803 86 7 92 1<br />

0-180 8468 94 1 100 0<br />

Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />

Based on 100 ft. x 100 ft. Open Manufacturing Area Multiplier<br />

I5 4L 54W T5HO 6L 54W T5HO 1.5<br />

Mounting<br />

Height<br />

Spacing 15 ft 20 ft 25 ft 30 ft 35 ft<br />

on Center FC LPD FC LPD FC LPD FC LPD FC LPD<br />

15 ft 45 0.75 42 0.75 39 0.75 36 0.75 34 0.75<br />

20 ft 31 0.52 29 0.52 27 0.52 25 0.52 24 0.52<br />

25 ft 20 0.33 19 0.33 17 0.33 16 0.33 15 0.33<br />

I5-454T5-TBW-UNV-EBT2-UPL<br />

(2) Electronic Ballasts<br />

(4) 54W T5 4400 lumens<br />

Spacing criterion: (II) 1 1 x mounting<br />

height, (⊥) 0 9 x mounting height<br />

Efficiency 81 2%<br />

Test Report: 236P112<br />

I5-354T5-TBW-UNV-EBT2-UPL<br />

(2) Electronic Ballasts<br />

(3) F54T5/HO lamps 4400 lumens<br />

Spacing criterion: (II) 1 0 x mounting<br />

height, (⊥) 0 7 x mounting height<br />

Efficiency 94 2%<br />

Test Report: 236P107<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

95 95 95 95 87 87 87 82 82 82<br />

88 85 82 80 78 76 74 74 72 71<br />

82 76 71 67 70 67 63 66 64 61<br />

75 68 63 58 63 59 55 60 57 54<br />

70 61 55 50 57 52 48 55 51 47<br />

64 55 49 44 52 46 42 49 45 41<br />

60 50 44 39 47 42 38 45 40 37<br />

56 46 39 35 43 38 34 41 37 33<br />

52 41 35 31 39 34 30 38 33 29<br />

48 38 31 27 36 30 26 34 29 26<br />

45 35 28 24 33 27 24 32 27 23<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 4945 28 1 34 6<br />

0-40 7390 42 0 51 7<br />

0-60 11071 62 9 77 5<br />

0-90 13159 74 8 92 1<br />

0-180 14293 81 2 100 0<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

110 110 110 110 100 100 100 94 94 94<br />

102 99 95 92 90 88 86 85 83 82<br />

95 88 83 78 81 77 74 77 74 71<br />

88 79 73 68 73 68 64 70 66 62<br />

81 71 64 59 66 61 57 63 59 55<br />

75 64 57 51 60 54 50 58 52 48<br />

70 59 51 46 55 49 44 53 47 43<br />

65 54 46 41 50 44 40 48 43 39<br />

60 49 42 37 46 40 36 44 39 35<br />

56 45 37 33 42 36 32 41 35 31<br />

53 41 34 29 39 33 29 37 32 28<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 4535 34 4 36 5<br />

0-40 6495 49 2 52 3<br />

0-60 9563 72 4 76 9<br />

0-90 11373 86 2 91 5<br />

0-180 12428 94 2 100 0<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

I8-432-UNV-EB81-UPL<br />

Electronic Ballast<br />

F32T8-TL835 lamps 3000 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 3 x mounting height<br />

Efficiency 91 2%<br />

Test Report: 236P197C<br />

107 107 107 107 98 98 98 92 92 92<br />

98 94 90 87 86 83 81 81 79 77<br />

89 82 76 71 75 71 67 71 68 64<br />

81 72 65 59 66 61 56 63 58 54<br />

74 64 56 50 59 53 48 56 51 46<br />

68 57 49 43 53 46 41 50 45 40<br />

63 51 43 37 48 41 36 46 40 35<br />

59 46 39 33 43 37 32 42 36 31<br />

54 42 35 29 40 33 29 38 32 28<br />

51 39 31 26 37 30 26 35 29 25<br />

48 36 29 24 34 28 23 33 27 23<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 2861 23 8 26 1<br />

0-40 4657 38 8 42 6<br />

0-60 8121 67 7 74 2<br />

0-90 10169 84 7 92 9<br />

0-180 10943 91 2 100 0<br />

Multiplier<br />

I8 4L 32W T8 w/Uplight 6L 32W T8 1.5<br />

Mounting<br />

Height<br />

Spacing 15 ft 20 ft 25 ft 30 ft 35 ft<br />

on Center FC LPD FC LPD FC LPD FC LPD FC LPD<br />

15 ft 36 0.4 33 0.4 30 0.4 28 0.4 26 0.4<br />

20 ft 25 0.28 23 0.28 21 0.28 20 0.52 18 0.28<br />

25 ft 16 0.18 15 0.18 14 0.18 13 0.33 12 0.18<br />

Choose the spacing and mounting height to determine the average footcandle and watts per square foot values. Use the multipliers to factor other available<br />

lamp/ballast configurations.<br />

18


19<br />

MB MICRO-BAY LUMINAIRE<br />

Occupancy Sensor<br />

Suspension is convenient and flexible with the SS<br />

Aircraft Cable “Y” Toggle Mounting Kits. Adjustment<br />

for luminaire mounting height is provided at luminaire<br />

rather than structure.<br />

Specular Miro reflectors for precise light control<br />

minimum 95% total reflectivity. Three optical<br />

distribution patterns are available:<br />

Focus - SC < .9<br />

Task - .9 ≤ SC < 1.2<br />

Normal - 1.2 ≤ SC ≤ 1.4<br />

Integral occupancy sensor available and<br />

provides from 600 sq. ft. up to 1250 sq. ft.<br />

of coverage in a maximum mounting<br />

height of 40'.<br />

Rigid exterior connector/coupling with pre-punched<br />

holes facilitates easy<br />

installation of coupled<br />

sections up to 32' long.<br />

Rigid Exterior Connector<br />

Optional pre-wired factory installed multiple<br />

circuit plug-in<br />

connectors.<br />

Plug-In Connectors<br />

Cable Mounting Kit<br />

MB Ordering Information Sample Number (T5): MB-154T5-FB-UNV-EBT1-U (T8): MB-132-NB-UNV-EB81-U<br />

4' and 8'<br />

2-11/16"<br />

[69mm]<br />

Number of Lamps<br />

(Not included)<br />

1=1 Lamp<br />

2=2 Lamps<br />

Lamp Types<br />

32=32W T8 (48")<br />

54T5=54W T5HO (48")<br />

Voltage<br />

UNV=Universal 120-277 Voltage<br />

UNC=Universal 347/480 Voltage<br />

Options<br />

GL=Single Element Fuse<br />

GM=Double Element Fuse<br />

EL=Emergency Installed (see table on pg 36) (2)<br />

Tandem<br />

Blank=<br />

4' Length<br />

8T=<br />

8' Length<br />

Series<br />

MB= Micro-Bay<br />

Ballast Type (1)<br />

T5 Systems<br />

EBT =T5 Linear Electronic Program Rapid<br />

Start Total Harmonic Distortion < 10%<br />

EHT =T5 Linear Electronic Program Rapid<br />

Start High Ambient<br />

Total Harmonic Distortion < 10% (4)<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start (5)<br />

Total Harmonic Distortion < 10%<br />

EB8 /PLUS= T8 Electronic Instant Start (5)<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

ER8 =T8 Electronic Program Rapid Start (5)<br />

Total Harmonic Distortion < 10%<br />

ER8 /PLUS= T8 Electronic Program Start (5)<br />

No of Ballast<br />

1 or 2<br />

Options<br />

PI/CPI=Plug-In (1, 2 or 3)<br />

See pg 40<br />

C3=3' Power Cord<br />

C6=6' Power Cord<br />

PC3-=3' Power Cord & Plug (Specify Voltage)<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

DIM=Dimming<br />

(3)<br />

PC6-=6' Power Cord & Plug (Specify Voltage) (3)<br />

Packaging<br />

U=Unit Pack<br />

Accessories (order separately)<br />

AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets<br />

w/S-Hooks<br />

GRIPPLE-Y- =Y Mounting Toggle, #2 Cable<br />

(Specify 10' or 30')<br />

GRIPPLE-TOGGLE- =Single Toggle, #2 Cable<br />

(Specify 10' or 30')<br />

No of Ballast<br />

MB-EXT-LONG-CONN-KIT-U=Rigid Connector<br />

1 or 2<br />

Support for Continuous Channel Installation<br />

Reflector<br />

FB=Concentrated Focus Beam<br />

TB=Medium Task Beam<br />

NB=Wide Normal Beam<br />

No of<br />

Ballast<br />

1 or 2<br />

No of Ballast<br />

1 or 2<br />

(3) (6)<br />

MS=Aisle Coverage Motion Sensor<br />

(3) (6)<br />

MSO=360° Coverage Motion Sensor<br />

MB-SENSOR-KIT-CTR/MT-U=Aisle Coverage<br />

Motion Sensor, Center Mount Hardware,<br />

120/277V<br />

MB-SENSOR-KIT-END/MT-U=Aisle Coverage<br />

Motion Sensor, End Mount Hardware,<br />

120/277V<br />

MB-SENSOR-KIT-CTR/480V-U=Aisle<br />

Coverage Motion Sensor, Center Mount<br />

Hardware, 480V<br />

MB-SENSOR-KIT-END/480V-U=Aisle<br />

Coverage Motion Sensor, End Mount<br />

Hardware, 480V<br />

WG/MB-4FT-T5-NB-B=Wireguard for T5HO (7)<br />

No of Ballast<br />

1 or 2<br />

NOTES: (1) Products also available in non-US voltages and frequencies for international markets (2) Voltage to be specified with emergency ballast option (3) Voltage must be<br />

specified when ordered with plugs, motion or emergency ballasts (4) 2 lamp ballast configurations only in UNC versions (5) ER8 and EB8 ballast systems suitable for operation<br />

in ambient environments up to 50°C (6) Must ship as accessory separately (7) No of<br />

Ballast<br />

1 or 2<br />

For use with T5HO Focus, Normal or Wide Beam optics only<br />

7/8" [23mm] K.O. (3)<br />

Ceiling Stand-Off<br />

Embossments<br />

(4’) 43-3/4" [1112mm]<br />

(4’) 48" [1220mm]<br />

UL/cUL listed to meet U.S.<br />

and Canadian standards.<br />

Dimensions<br />

Dimensions for Top View<br />

T5 Lamp Configurations<br />

5-11/16"<br />

[145mm]<br />

X=2-11/16"<br />

[69mm]<br />

3-5/32"<br />

[81mm]<br />

X=2-11/16"<br />

[69mm]<br />

Focus Beam 1 or 2 Lamp<br />

3-5/32"<br />

[81mm]<br />

X=2-11/16"<br />

[69mm]<br />

Focus Beam 1 or 2 Lamp<br />

3-9/32"<br />

[84mm]<br />

X=2-11/16"<br />

[69mm]<br />

X<br />

4-5/16"<br />

[110mm]<br />

Normal Beam 1 or 2 Lamp<br />

3-9/32"<br />

[84mm]<br />

X=2-11/16"<br />

[69mm]<br />

Task Beam 1 or 2 Lamp<br />

3-9/32"<br />

[84mm]<br />

X=2-11/16"<br />

[69mm]<br />

1-3/4" x 3-1/4" K.O. (1)<br />

Ground Screw Bump<br />

(8’) 91-3/4" [2330mm]<br />

(8’) 96" [2438mm]<br />

X<br />

4-5/16"<br />

[110mm]<br />

X<br />

4-5/16"<br />

[110mm]<br />

X<br />

9-1/16" [231mm]<br />

X<br />

7-3/32"<br />

[181mm]<br />

Task Beam 1 or 2 Lamp<br />

X<br />

7-9/16"<br />

[193mm]<br />

1-31/32" [51mm]<br />

1"<br />

[26mm]<br />

1-31/32" [51mm]<br />

1-3/16"<br />

[31mm]<br />

1-31/32" [51mm]<br />

1-7/16"<br />

[37mm]<br />

T8 Lamp Configurations<br />

29/32"<br />

[24mm]<br />

Normal Beam 1 or 2 Lamp<br />

29/32"<br />

[24mm]<br />

29/32"<br />

[24mm]


Photometrics<br />

⊥<br />

||<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

MB-132-NB-UNV-EB81<br />

Electronic Ballast<br />

(1) 32WT8 Lamp 2850 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 2 x mounting height<br />

Efficiency 94 1%<br />

Test Report: 10267<br />

System Performance<br />

Energy<br />

Savings<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

2 LAMP T12 1 LAMP T12<br />

HO<br />

56%<br />

38%<br />

112 112 112 112 105 105 105 100 100 100<br />

101 97 92 88 90 87 84 87 84 81<br />

92 84 77 71 78 73 69 75 71 67<br />

84 73 65 59 69 62 57 66 61 56<br />

76 65 56 50 61 54 49 59 53 48<br />

70 58 49 43 55 47 42 53 46 41<br />

65 52 43 37 49 42 37 48 41 36<br />

60 47 39 33 45 38 32 44 37 32<br />

56 43 35 29 41 34 29 40 34 29<br />

52 40 32 26 38 31 26 37 31 26<br />

49 37 29 24 35 28 24 34 28 24<br />

61%<br />

MB-232-FB-EB81<br />

T8<br />

Illuminance Estimator<br />

MB<br />

37%<br />

System Performance Table<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30<br />

0-40<br />

0-60<br />

0-90<br />

0-180<br />

2 LAMP T12<br />

48%<br />

23%<br />

722 25 3 26 9<br />

1133 39 8 42 3<br />

2012 70 6 75 0<br />

2679 94 0 99 9<br />

2682 94 1 100 0<br />

55%<br />

MB-154T5-FB-EBT1<br />

T5<br />

1 LAMP T12<br />

HO<br />

22%<br />

8TMB<br />

2 LAMP T12<br />

% light gain/light loss utilize S/P adjusted lumens.<br />

56%<br />

38%<br />

61%<br />

8TMB-232-FB-EB81<br />

T8<br />

1 LAMP T12<br />

HO<br />

Micro-Bay<br />

Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />

Based on 120 ft. x 10 ft. Aisle<br />

20 ft 25 ft 30 ft 35 ft 40 ft<br />

Qty FC LPD Qty FC LPD Qty FC LPD Qty FC LPD Qty FC LPD<br />

MB-132-NB 30 31 0.8 38 32 1.01 44 31 1.17 52 31 1.39 58 30 1.55<br />

MB-154-NB 17 31 0.84 21 31 1.03 24 35 1.18 28 30 1.38 32 30 1.57<br />

MB-232-FB 16 31 0.76 19 30 0.90 23 31 1.09 26 30 1.24 30 30 1.43<br />

MB-254-FB 11 32 0.99 13 31 1.17 16 32 1.44 18 31 1.62 20 30 1.80<br />

37%<br />

||<br />

||<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

MB-132-TB-UNV-EB81<br />

(1) Electronic Ballast<br />

(1) 32W T8 lamps 2850 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 0 x mounting height<br />

Efficiency 95 1%<br />

Test Report: 10266<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

MB-132-FB-UNV-EB81<br />

(1) Electronic Ballast<br />

(1) 32W T8 lamps 2850 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 0 9 x mounting height<br />

Efficiency 91 4%<br />

Test Report: 09512<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

113 113 113 113 106 106 106 101 101 101<br />

102 97 93 89 91 88 85 87 84 82<br />

93 84 77 71 79 73 69 76 71 67<br />

84 73 65 59 69 62 57 66 61 56<br />

77 65 56 49 61 54 48 59 53 48<br />

70 58 49 42 55 47 42 53 46 41<br />

65 52 43 37 49 42 36 48 41 36<br />

60 47 39 33 45 37 32 43 37 32<br />

56 43 35 29 41 34 29 40 33 29<br />

53 40 32 26 38 31 26 37 30 26<br />

49 37 29 24 35 28 24 34 28 23<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 700 24 6 25 8<br />

0-40 1104 38 7 40 7<br />

0-60 2001 70 2 73 8<br />

0-90 2707 95 0 99 9<br />

0-180 2711 95 1 100 0<br />

109 109 109 109 101 101 101 97 97 97<br />

99 95 91 88 89 86 84 86 83 81<br />

91 83 77 72 78 73 69 75 71 68<br />

83 73 66 60 69 63 58 66 61 57<br />

76 65 57 51 62 55 50 59 54 49<br />

70 58 50 44 55 49 44 54 48 43<br />

65 53 45 39 50 43 38 49 43 38<br />

60 48 40 35 46 39 34 45 39 34<br />

56 44 36 31 42 36 31 41 35 31<br />

53 41 33 28 39 33 28 38 32 28<br />

50 38 31 26 36 30 26 35 30 26<br />

Zonal Lumen Summary<br />

0-30<br />

0-40<br />

0-60<br />

0-90<br />

0-180<br />

787 27 6 30 2<br />

1211 42 5 46 5<br />

2048 71 9 78 7<br />

2599 91 2 99 8<br />

2604 91 4 100 0<br />

Choose the spacing and mounting height to determine<br />

the average footcandle and watts per square foot values.<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

MB System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens 2 Ratio 3 Perception Lumens 4 Wattage LER 5<br />

MB-232-FB-EB81 2 3100 94% 95% 1.00 5542 1.95 1.40 7740 56 $2.43 131<br />

MB-154T5-FB-UNV-EBT1 1 5000 93% 98% 1.00 4543 1.90 1.38 6262 65 $3.40 94<br />

8TMB-232-FB-EB81 2 3100 94% 95% 1.00 5537 1.95 1.40 7731 56 $2.44 131<br />

Comparison System<br />

(2) 34W T12 Strip 2 2750 88% 90% 0.90 3920 1.50 1.22 4801 126 $10.37 31<br />

(1) 96" T12HO Strip 1 8630 58% 90% 0.88 3964 1.50 1.22 4855 145 $12.07 27<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 5 LER (Luminaire Efficiency Ratio) is an<br />

accepted method of comparing fixture performance<br />

20


21<br />

3HBOT HIGH-BAY INDUSTRIAL LUMINAIRE<br />

Side rails are used to protect<br />

optical cavity and add rigidity.<br />

Pressure lock lampholders.<br />

Optional modular power receptacle and cord sets meets<br />

UL2459 and NEC 410.73 and are UL/cUL rated for make<br />

and break under load from outside the luminaire.<br />

Ordering Information Sample Number: 3HBOT-832-UNV-EB82/PLUS-UPL-U<br />

Width<br />

3=32" wide<br />

Series<br />

HBOT=High Bay Open<br />

Top Version<br />

No of Lamps<br />

8=8 Lamps<br />

Wattage (Length)<br />

32=32W T8 Lamps (48")<br />

54T5=54W T5HO Lamps (48")<br />

Distribution<br />

Blank=Medium (Specular Aluminum)<br />

G=Wide (White Painted)<br />

Voltage (2)<br />

UNV=Universal<br />

120/277 Voltage<br />

UNC=Universal<br />

347/480 Voltage (6)<br />

120V=120 Volt<br />

277V=277 Volt<br />

347V=347 Volt<br />

480V=480 Volt<br />

Options<br />

Lamps Installed<br />

L8830=T8 Lamp, 85CRI 3000K<br />

L8835=T8 Lamp, 85CRI 3500K<br />

L8841=T8 Lamp, 85CRI 4100K<br />

L8850=T8 Lamp, 85CRI 5000K<br />

L5830=T5 Lamp, 85CRI 3000K<br />

L5835=T5 Lamp, 85CRI 3500K<br />

L5841=T5 Lamp, 85CRI 4100K<br />

L5850=T5 Lamp, 85CRI 5000K<br />

GL=Single Element Fuse<br />

GM=Double Element Fuse<br />

EL=Emergency Installed (2)<br />

(see table on pg 36)<br />

NOTES: (1) Requires use of MC or MPC cord accessories, specify voltage for plugs (2) Voltage must be specified<br />

when ordered with plugs, motion or emergency ballasts (3) EBT ballast systems suitable for operation in<br />

ambient environments up to 104°F (40°C) (4) Specify voltage on ballast (5) For use with Top Connector Box<br />

options See accessories (6) 2 lamp ballast configurations only in EHT-UNC versions (7) ER8 and EB8 ballast<br />

systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration<br />

Specification grade open body<br />

housing, end plates and socket<br />

tracks are die formed 20 gauge<br />

cold rolled steel.<br />

Thermally optimized F-Bay is suitable for environments<br />

up to 122°F (50°C) when used with high temperature<br />

environment ballasts.<br />

Die formed reflectors are faceted for 8 lamp configurations with two<br />

optical distributions medium and wide. Medium beam optical modules<br />

utilize 95% specular Miro 4 substrate while the wide distribution utilizes a<br />

high performance 95% reflective polyester powder coated finish.<br />

Ballast Type<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start (7)<br />

Total Harmonic Distortion < 10%<br />

EB8 /PLUS= T8 Electronic Instant Start (7)<br />

No of Ballast<br />

2 or 3<br />

No of<br />

Ballast<br />

2 or 3<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

ER8 =T8 Electronic Program Rapid Start (7)<br />

Total Harmonic Distortion < 10%<br />

ER8 /PLUS= T8 Electronic Program Start (7)<br />

No of Ballast<br />

2 or 3<br />

No of<br />

Ballast<br />

2 or 3<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

T5 Systems<br />

EBT =T5 Linear Electronic Program Rapid Start (3)<br />

Total Harmonic Distortion < 10%<br />

EHT =T5 Programmed Start High Ambient (6)<br />

No of Ballast<br />

2, 3 or 4<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

2, 3 or 4<br />

DIM=Dimming<br />

Integral occupancy sensor available and<br />

provides from 600 sq. ft. up to 1250 sq.<br />

ft. of coverage at a maximum mounting<br />

height of 40'.<br />

Options<br />

UPL=Uplight Apertures<br />

PI/CPI=Plug-In (1, 2 or 3)<br />

See pg 40<br />

TILW=Tandem Inline Wiring<br />

MWS=Modular Wiring System<br />

MS=Aisle Coverage Motion<br />

Sensor (4)<br />

MSO=360° Coverage Motion Sensor (4)<br />

(1) (2)<br />

MP=Modular Power Receptacle<br />

PC3-=3' Power Cord & Plug (Specify Voltage) (2)<br />

PC6-=6' Power Cord & Plug (Specify Voltage) (2)<br />

TCBP=Top Connector Box Plate (5)<br />

Packaging<br />

U=Unit Pack<br />

PAL=Palletized<br />

Out of Carton<br />

PALC=Palletized<br />

In Carton<br />

Accessories (order separately)<br />

AYC-CHAIN/SET/U=(2) Hooks, 36" Chain<br />

Sets w/S-Hooks<br />

TCB=Top Connector Box<br />

RH-1=Retrofit Hanger<br />

FH-1=Fixture Hook<br />

FL-1=Fixture Loop<br />

MPC6=6' Modular Power Cord & Plug<br />

(Specify Voltage)<br />

MC6=6' Modular Power Cord<br />

MMS-CPD1200H=Aisle Motion Sensor, Box,<br />

Modular Power Receptacle (120/277V)<br />

MMS-CPD500H=360° Motion Sensor, Box,<br />

Modular Power Receptacle (120/277V)


Photometrics<br />

System Performance<br />

Mounting<br />

Height<br />

40'<br />

Energy<br />

Savings<br />

30'<br />

20'<br />

10'<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

1000W MH<br />

-18%<br />

3HBOT<br />

T8<br />

72%<br />

3HBOT-<br />

832-<br />

EB/PLUS<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

3HBOT-854T5-UNV-EBT2-UPL<br />

(2) Electronic Ballasts<br />

(8) F54T5HO/841 54W T5 lamps 4500 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 0 x mounting height<br />

Efficiency 90 3%<br />

Test Report: 3HB854T5UPL IES<br />

1000W MH<br />

T5<br />

58%<br />

14%<br />

3HBOT-<br />

854T5-<br />

EBT2<br />

% light gain/light loss<br />

utilize S/P adjusted<br />

lumens.<br />

System Performance Table<br />

106 106 106 106 98 98 98 93 93 93<br />

100 97 94 92 90 88 86 86 84 83<br />

93 88 84 80 82 79 76 79 76 74<br />

87 80 74 70 75 71 67 72 69 66<br />

81 73 67 62 69 64 60 66 62 59<br />

75 66 59 54 62 57 53 60 56 52<br />

70 60 54 49 57 52 48 55 50 47<br />

65 55 48 44 52 47 43 51 46 42<br />

61 50 43 39 48 42 38 46 41 37<br />

56 45 39 34 43 37 33 42 37 33<br />

52 41 35 30 40 34 30 39 33 30<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 13023 36 2 40 0<br />

0-40 19856 55 2 61 1<br />

0-60 28801 80 0 88 6<br />

0-90 30819 85 6 94 8<br />

0-180 32523 90 3 100 0<br />

Dimensions<br />

3HBOT Lamp Configurations<br />

8-lamp<br />

5-3/16" [131mm]<br />

Dimensions for Top View<br />

32-5/16"<br />

[820mm]<br />

X=4"<br />

[102mm]<br />

Illuminance Estimator<br />

Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />

Based on 100 ft. x 100 ft. Open Area<br />

3HBOT 8L 54W T5HO w/Uplight<br />

Spacing 15 ft 20 ft 25 ft 30 ft 35 ft 40 ft<br />

on Center FC LPD FC LPD FC LPD FC LPD FC LPD FC LPD<br />

20 ft 57 0.91 53 0.91 50 0.91 47 0.91 45 0.91 42 0.91<br />

25 ft 36 0.58 34 0.58 32 0.58 30 0.58 29 0.58 27 0.58<br />

30 ft 20 0.33 19 0.33 18 0.33 17 0.33 16 0.33 15 0.33<br />

35 ft 9 0.15 9 0.15 8 0.15 8 0.15 7 0.15 7 0.15<br />

Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />

Based on 100 ft. x 100 ft. Open Area<br />

3HBOT 8L 32W T8 w/Uplight<br />

Choose the spacing and mounting height to determine the average footcandle and<br />

watts per square foot values.<br />

X X X X X X X<br />

32-11/16" [830mm]<br />

Ceiling Standoff<br />

Embossment<br />

41-1/2" [1054mm]<br />

33" [838mm]<br />

48" [1220mm]<br />

Top Connector<br />

Emboss<br />

7/8" KO (4)<br />

11/16" X 1"<br />

KO (2)<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

Mounting<br />

Height<br />

Mounting<br />

Height<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

Spacing 15 ft 20 ft 25 ft 30 ft 35 ft 40 ft<br />

on Center FC LPD FC LPD FC LPD FC LPD FC LPD FC LPD<br />

20 ft 52 0.56 48 0.56 45 0.56 42 0.56 40 0.56 37 0.56<br />

25 ft 33 0.36 31 0.36 29 0.36 27 0.36 25 0.36 24 0.36<br />

30 ft 19 0.20 17 0.20 16 0.20 15 0.20 14 0.20 13 0.20<br />

35 ft 8 0.09 8 0.09 7 0.09 7 0.09 6 0.09 6 0.09<br />

3HBO System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4 Wattage LER5 3HBOT-832-EB/PLUS 8 3100 94% 90% 1.15 24128 1.95 1.40 33693 302 $2.77 115<br />

3HBOT-854T5-EBT2<br />

Comparison System<br />

8 5000 93% 90% 1.00 33480 1.90 1.38 46149 458 $3.53 91<br />

1000W Metal Halide High Bay 1 102800 45% 70% 1.00 32382 1.50 1.22 39660 1085 $12.51 26<br />

22


23<br />

2HBG RECESSED HIGH-BAY INDUSTRIAL LUMINAIRE<br />

Heavy gauge end plates, securely<br />

attached with interlocking tabs<br />

and screws.<br />

Recessed mount for in standard grid/lay-in,<br />

concealed T, and slot grid ceilings.<br />

Flange trim with supporting swing<br />

gates conceal the edges of the<br />

ceiling opening.<br />

Pressure lock lampholders.<br />

Ordering Information Sample Number: 2HBG-654T5-A-UNV-EBT2-U<br />

Width<br />

2=24"<br />

Series<br />

HB=High Bay<br />

No of Lamps<br />

4=4 Lamps<br />

6=6 Lamps<br />

Prismatic and clear lens with<br />

door frame option<br />

Trim Type<br />

G=Grid/Lay-in (Standard)<br />

F=Flange Trim<br />

Lamp Type<br />

32=32W T8 Lamps (48")<br />

28T5=28W T5 Lamps (48")<br />

54T5=54W T5HO Lamps (48")<br />

Distribution Optic<br />

Blank=Medium (Specular Aluminum)<br />

G=Wide (White Painted)<br />

Downlight Optic<br />

Blank=Open<br />

A=Prismatic Acrylic Lens & Steel Door Frame<br />

CL=Clear Acrylic Lens & Steel Door Frame<br />

NOTES: (1) Voltage must be specified when ordered with emergency ballasts (2) ER8 and EB8 ballast systems suitable for operation<br />

in ambient environments up to 122°F (50°C) without lens option<br />

Nominal 6-5/8" deep, para-contoured<br />

housing, die formed 20 gauge cold<br />

rolled steel.<br />

End plates have integral Grid-Lock feature for safety and<br />

convenience. Housing features enable fixture to be converted<br />

from Grid to T-Option or vice-versa in the field.<br />

Die formed reflectors are faceted for 4 and 6 lamp configurations with two optical distributions<br />

medium and wide. Medium beam optical modules utilize 95% specular Miro 4 substrate while<br />

the wide distribution utilizes a high performance 95% reflective polyester powder coated finish.<br />

Voltage (1)<br />

UNV=Universal<br />

120/277 Voltage<br />

UNC=Universal<br />

347/480 Voltage (T5 linear only)<br />

120V=120 Volt<br />

277V=277 Volt<br />

347V=347 Volt<br />

Options<br />

Lamps Installed<br />

L8830=T8 Lamp, 85CRI 3000K<br />

L8835=T8 Lamp, 85CRI 3500K<br />

L8841=T8 Lamp, 85CRI 4100K<br />

L8850=T8 Lamp, 85CRI 5000K<br />

L5830=T5 Lamp, 85CRI 3000K<br />

L5835=T5 Lamp, 85CRI 3500K<br />

L5841=T5 Lamp, 85CRI 4100K<br />

L5850=T5 Lamp, 85CRI 5000K<br />

GL=Single Element Fuse<br />

GM=Double Element Fuse<br />

EL=Emergency Installed (1)<br />

(see table on pg 36)<br />

Ballast Type<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start (2)<br />

Total Harmonic Distortion < 10%<br />

EB8 /PLUS= T8 Electronic Instant Start (2)<br />

No of Ballast<br />

1 or 2<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

Ceiling Compatibility<br />

G<br />

Grid/Lay-in<br />

Standard<br />

F<br />

Flange Trim<br />

With Supporting<br />

Swing Gates<br />

Packaging<br />

U=Unit Pack<br />

PAL=Job Pack, out of carton<br />

PALC=Job Pack, in carton<br />

Accessories (order separately)<br />

MWS=Modular Wiring System,<br />

(Refer to MWS Catalog Online)<br />

ER8 =T8 Electronic Program Rapid Start Total Harmonic Distortion < 10% (2)<br />

ER8 /PLUS= T8 Electronic Program Start High Ballast Factor >1 15 (2)<br />

No of<br />

Ballast<br />

1 or 2<br />

No of Ballast<br />

1 or 2<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1 or 2<br />

T5 Systems<br />

EBT =T5 or T5HO Linear Electronic Program Rapid Start<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1 or 2<br />

Ceiling Trim<br />

Type Type<br />

Exposed Grid G<br />

Concealed T G<br />

Slot Grid G<br />

Flange F


Photometrics<br />

||<br />

2HBG-632-UNV-EB82<br />

(2) Electronic Ballasts<br />

(6) F32T8/TL835 lamps 3000 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 4 x mounting height<br />

Efficiency 83 4%<br />

Test Report: 2HBG632 IES<br />

System Performance<br />

Mounting<br />

Height<br />

40'<br />

Energy<br />

Savings<br />

30'<br />

20'<br />

10'<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

⊥<br />

250W MH<br />

-33%<br />

68%<br />

- 33%<br />

68%<br />

2HBG-432-ER8/PLUS<br />

System Performance Table<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

250W HID<br />

99 99 99 99 93 93 93 89 89 89<br />

91 87 83 80 81 79 76 78 76 74<br />

82 76 70 65 71 67 63 68 65 61<br />

75 66 59 54 62 57 53 60 56 52<br />

69 59 51 46 56 50 45 54 48 44<br />

63 53 45 39 50 44 39 48 43 38<br />

58 47 40 34 45 39 34 44 38 34<br />

54 43 36 30 41 35 30 40 34 30<br />

50 39 32 27 37 31 27 36 31 27<br />

47 36 29 24 34 28 24 34 28 24<br />

44 33 26 22 32 26 22 31 26 22<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 4174 23 2 27 8<br />

0-40 6937 38 5 46 2<br />

0-60 11814 65 6 78 7<br />

0-90 15014 83 4 91 5<br />

0-180 15014 83 4 100 0<br />

400W MH 400W HID<br />

51%<br />

11%<br />

51%<br />

11%<br />

2HBG-632-ER82/PLUS<br />

2HBG<br />

50%<br />

3%<br />

2HBG-454-EBT1<br />

51%<br />

3%<br />

T8 T5<br />

% light gain/light loss utilize S/P adjusted lumens.<br />

250W MH 250W HID<br />

400W MH 400W HID<br />

24%<br />

35%<br />

2HBG-654-EBT2<br />

25%<br />

35%<br />

Dimensions for Top View<br />

23-3/4"<br />

[603mm]<br />

7/8" [22mm]<br />

K.O. (4)<br />

Access Plate<br />

7/8" [22mm] K.O. (2)<br />

5-1/4" [133mm]<br />

3-3/4" [95mm]<br />

7-23/32" [196mm]<br />

48" [1219mm]<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 4100K lamps 5 LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

⊥<br />

2HBG-654T5-UNV-EBT2<br />

(3) Electronic Ballasts<br />

(6) F54T5HO/841 lamps 4400 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 1 x mounting height<br />

Efficiency 73 5%<br />

Test Report: 2HBG654T5 IES<br />

6-lamp<br />

||<br />

4-5/8"<br />

[117mm]<br />

X=3-1/2"<br />

[89mm]<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

Dimensions<br />

88 88 88 88 82 82 82 78 78 78<br />

81 78 75 72 73 71 69 70 68 67<br />

74 68 64 60 65 61 58 62 59 57<br />

68 61 55 51 58 53 50 56 52 49<br />

63 55 48 44 52 47 43 50 46 42<br />

58 49 43 38 47 42 38 45 41 37<br />

54 45 38 34 43 37 34 41 37 33<br />

50 41 35 30 39 34 30 38 33 30<br />

47 37 32 27 36 31 27 35 30 27<br />

44 35 29 25 33 28 25 33 28 25<br />

41 32 27 23 31 26 23 30 26 23<br />

2HBG Lamp Configurations<br />

4-lamp<br />

5-5/8"<br />

[143mm]<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 6821 25 8 35 1<br />

0-40 10503 39 8 54 1<br />

0-60 16195 61 3 83 4<br />

0-90 19412 73 5 100 0<br />

0-180 19412 73 5 100 0<br />

X X X X X<br />

23-3/4" [603mm]<br />

23-3/4" [603mm]<br />

2HBG System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4 Wattage LER5 2HBG-432-ER81/PLUS 4 3100 94% 80% 1.15 10724 1.95 1.40 14975 147 $3.41 94<br />

2HBG-632-EB82/PLUS 6 3100 94% 80% 1.15 16085 1.95 1.40 22462 221 $3.42 94<br />

2HBG-454T5-EBT1 4 5000 93% 80% 1.00 14880 1.90 1.38 20511 229 $4.47 72<br />

2HBG-654T5-EBT2<br />

Comparison System<br />

6 5000 93% 80% 1.00 22320 1.90 1.38 30766 346 $4.50 71<br />

250W Metal Halide High Bay 1 20800 58% 78% 1.00 9422 1.50 1.22 11540 295 $10.47 31<br />

250W High Pressure Sodium High Bay 1 30000 81% 78% 1.00 18978 0.62 0.79 14944 300 $8.23 39<br />

400W Metal Halide High Bay 1 36000 58% 78% 1.00 16307 1.50 1.22 19972 455 $9.33 34<br />

400W High Pressure Sodium High Bay 1 50000 81% 78% 1.00 31631 0.62 0.79 24906 464 $7.63 42<br />

1-1/2"<br />

[38mm]<br />

24


25<br />

HBHD HOSEDOWN HIGH-BAY INDUSTRIAL LUMINAIRE<br />

High performance white enamel finish improves efficiency<br />

and protects against elements. Optional brushed stainless<br />

steel finish for corrosive chemical environments.<br />

White, closed cell, Flexiseal gasketing<br />

surrounds perimeter of lens to seal lens<br />

to door frame and around perimeter of<br />

door to seal door to housing. Another<br />

layer seals fixture to ceiling<br />

system after installation.<br />

Sealed housing is enclosed and<br />

gasketed to provide 800 psi hose<br />

down protection.<br />

One piece, heavy gauge extruded lens<br />

in prismatic clear acrylic.<br />

Die formed reflectors are faceted for 4 and 6 lamp configurations with two optical distributions medium and wide.<br />

Medium beam optical modules utilize 95% specular Miro 4 substrate while the wide distribution utilizes a high<br />

performance 95% reflective polyester powder coated finish.<br />

UL/cUL and CSA listed for wet locations. Manufactured in compliance with USDA, FDA, NSF and Federal Standard 209E in surface mount applications.<br />

Ordering Information Sample Number: 2HBHD-654T5-A-UNV-EBT2-U<br />

Width<br />

2=24"<br />

Series<br />

HBHD=High Bay<br />

Hose Down<br />

No of Lamps<br />

4=4 Lamps<br />

6=6 Lamps<br />

Product can be surface or<br />

suspension mounted.<br />

Lamp Type<br />

32=32W T8 Lamps (48")<br />

28T5=28W T5 Lamps (48")<br />

54T5=54W T5HO Lamps (48")<br />

Distribution<br />

Blank=Medium (Specular Aluminum)<br />

G=Wide (High Reflectance White)<br />

Shielding<br />

A=Prismatic Acrylic<br />

Lens & Door Frame<br />

CL=Clear Acrylic Lens<br />

& Door Frame<br />

Voltage (1)<br />

UNV=Universal<br />

120/277 Voltage<br />

UNC=Universal<br />

347/480 Voltage (T5 linear only) (2)<br />

120V=120 Volt<br />

277V=277 Volt<br />

347V=347 Volt<br />

480V=480 Volt<br />

Options<br />

Lamps Installed<br />

L8830=T8 Lamp, 85CRI 3000K<br />

L8835=T8 Lamp, 85CRI 3500K<br />

L8841=T8 Lamp, 85CRI 4100K<br />

L8850=T8 Lamp, 85CRI 5000K<br />

L5830=T5 Lamp, 85CRI 3000K<br />

L5835=T5 Lamp, 85CRI 3500K<br />

L5841=T5 Lamp, 85CRI 4100K<br />

L5850=T5 Lamp, 85CRI 5000K<br />

GL=Single Element Fuse<br />

GM=Double Element Fuse<br />

EL=Emergency Installed (1)<br />

(see table on pg 36)<br />

Ballast Type (1)<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1 or 2<br />

EB8 /PLUS= T8 Electronic Instant Start<br />

No of<br />

Ballast<br />

1 or 2<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

ER8 =T8 Electronic Program Rapid Start<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1 or 2<br />

ER8 /PLUS= T8 Electronic Program Start<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

T5 Systems<br />

EBT =T5 Linear Electronic Program Rapid Start<br />

Total Harmonic Distortion < 10%<br />

EHT =T5 Linear Electronic Start High Ambient (2)<br />

No of Ballast<br />

1, 2 or 3<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1, 2 or 3<br />

DIM=Dimming<br />

Captive, flush mounted stainless steel fasteners secure one<br />

piece door to housing.<br />

Options (3)<br />

C3=3' Power Cord<br />

C6=6' Power Cord<br />

PC3-=3' Power Cord & Plug<br />

(Specify Voltage) (1)<br />

PC6-=6' Power Cord & Plug<br />

(Specify Voltage) (1)<br />

SSN=Stainless Steel Door/Brushed<br />

304 Finish<br />

SHN=Stainless Steel Housing<br />

Brushed 304 Finish<br />

PM=Pendant Mount (4)<br />

Packaging<br />

U=Unit Pack<br />

PAL=Pallet Pack<br />

PALC=Job Pack<br />

In Carton<br />

Accessories (order separately)<br />

SCA-48=Stem Set Adjustable 48" length<br />

SCF-=Stem Set Fixed (specify length)<br />

SCS=Stem Set 45° Swivel (specify length)<br />

NOTES: (1) Voltage must be specified when ordered with plugs or emergency ballasts (2) 2 lamp ballast configurations only in UNC versions (3) Cord and plug options only available with pendant mount option (4) Stems must be<br />

ordered separately, see accessories<br />

No of<br />

Ballast<br />

1 or 2


Photometrics<br />

System Performance Table<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

2HBHD-632-CL-UNV-EB82<br />

(2) Electronic Ballasts<br />

(6) F32T8/TL835 lamps 3000 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 2 x mounting height<br />

Efficiency 68 1%<br />

Test Report: 2HBHD632CL IES<br />

System Performance<br />

Mounting<br />

Height<br />

40'<br />

Energy<br />

Savings<br />

30'<br />

20'<br />

10'<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

250W MH 250W HPS<br />

50%<br />

21%<br />

-2%<br />

2HBHD-432-CL-<br />

EB81/PLUS<br />

81 81 81 81 76 76 76 72 72 72<br />

75 72 69 66 67 65 63 65 63 61<br />

68 63 58 55 59 56 53 57 54 52<br />

62 56 50 46 52 48 45 51 47 44<br />

57 49 44 39 47 42 38 45 41 38<br />

53 44 38 34 42 37 34 41 37 33<br />

49 40 34 30 38 33 30 37 33 29<br />

45 36 31 27 35 30 26 34 29 26<br />

42 33 28 24 32 27 24 31 27 23<br />

40 31 25 21 29 25 21 29 24 21<br />

37 28 23 19 27 23 19 27 22 19<br />

51%<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30<br />

0-40<br />

0-60<br />

0-90<br />

0-180<br />

3768 20 9 30 7<br />

6124 34 0 50 0<br />

10121 56 2 82 6<br />

12258 68 1 91 5<br />

12258 68 1 100 0<br />

400W MH 400W HPS<br />

51%<br />

9%<br />

-13%<br />

2HBHD-632-CL-<br />

EB81/PLUS<br />

2HBHD<br />

52%<br />

T8 T5<br />

% light gain/light loss utilize S/P adjusted lumens.<br />

250W MH 250W HPS<br />

22%<br />

26%<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

HBHD Lamp Configurations<br />

Dimensions for Top View<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

24%<br />

4%<br />

400W MH 400W HPS<br />

24%<br />

15%<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

2HBHD-654T5-CL-UNV-EBT2<br />

(3) Electronic Ballasts<br />

(6) F54T5HO/841 54W lamps 4400 lumens<br />

Spacing criterion: (II) 1 0 x mounting<br />

height, (⊥) 1 2 x mounting height<br />

Efficiency 52 9%<br />

Test Report: 2HBHD654T5CL IES<br />

-6%<br />

25%<br />

2HBHD-454-CL-EBT1 2HBHD-654-CL-EBT2<br />

Dimensions<br />

4-lamp<br />

4-1/2"<br />

[115mm]<br />

6-lamp<br />

4-1/2"<br />

[115mm]<br />

X=3-1/2"<br />

[89mm]<br />

(4) 3/8" [10mm] Dia<br />

Mounting Hole<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

70 70 70 70 66 66 66 63 63 63<br />

65 63 61 59 59 57 56 57 55 54<br />

60 56 52 49 53 50 47 51 48 46<br />

55 50 45 42 47 44 41 46 43 40<br />

51 45 40 36 42 39 36 41 38 35<br />

47 40 36 32 39 35 31 37 34 31<br />

44 37 32 28 35 31 28 34 31 28<br />

41 34 29 26 32 28 25 32 28 25<br />

38 31 26 23 30 26 23 29 26 23<br />

36 29 24 21 28 24 21 27 23 21<br />

34 27 22 19 26 22 19 25 22 19<br />

36"<br />

[914mm]<br />

48"<br />

[1219mm]<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30<br />

0-40<br />

0-60<br />

0-90<br />

0-180<br />

5876 22 3 37 6<br />

8802 33 3 56 3<br />

13385 50 7 85 7<br />

15627 59 2 75 3<br />

15627 59 2 100 0<br />

5" 5" 5"<br />

[127mm] [127mm] [127mm]<br />

X<br />

23-11/16" [602mm]<br />

X X X X<br />

23-11/16" [602mm]<br />

2HBHD System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens 2 Ratio 3 Perception Lumens 4 Wattage LER 5<br />

2HBHD-432-CL-EB81/PLUS 4 3100 94% 68% 1.15 9128 1.95 1.40 12747 147 $4.71 68<br />

2HBHD-632-CL-EB82/PLUS 6 3100 94% 68% 1.15 13693 1.95 1.40 19121 221 $4.72 68<br />

2HBHD-454T5-CL-EBT1 4 5000 93% 53% 1.00 9839 1.90 1.38 13563 229 $10.21 31<br />

2HBHD-654T5-CL-EBT2 6 5000 93% 53% 1.00 14759 1.90 1.38 20344 346 $10.29 31<br />

Comparison System<br />

250W Metal Halide Encl & Gasketed High Bay 1 20800 58% 68% 1.00 8179 1.50 1.22 10018 295 $13.90 23<br />

250W High Pressure Sodium Encl & Gasketed High Bay 1 30000 81% 68% 1.00 16475 0.62 0.79 12973 300 $10.91 29<br />

400W Metal Halide Encl & Gasketed High Bay 1 36000 58% 68% 1.00 14157 1.50 1.22 17338 455 $12.39 26<br />

400W High Pressure Sodium Encl & Gasketed High Bay 1 50000 81% 68% 1.00 27459 0.62 0.79 21621 464 $10.13 32<br />

(2) 7/8" [22mm] KO<br />

Gasketed Access Plate<br />

1 1/2"<br />

[38mm]<br />

12"<br />

[305mm]<br />

10 3/16"<br />

[259mm]<br />

23 11/16"<br />

[602mm]<br />

26


27<br />

ARCTIC BAY - AB Series HIGH-BAY INDUSTRIAL LUMINAIRE<br />

Enclosed, full bodied 20 gauge housing utilizes captive fasteners<br />

to protect optical assembly and assure structural integrity of<br />

housing while retaining heat for optimal system performance.<br />

Thermally optimized Arctic Bay is suitable for<br />

environments down to -20°F (-29°C).<br />

Housing is “post” painted with a<br />

high performance polyester<br />

powder coat finish to protect<br />

against contaminants and<br />

oxidation.<br />

Sealed and gasketed door frame provides a thermal<br />

environment for optimal lamp operation. Optional<br />

clear or prismatic shielding available.<br />

Ordering Information Sample Number: 2AB-654T5-UNV-EBT2-MS/0B-U<br />

Width<br />

Blank=15"<br />

2=24"<br />

Series<br />

AB=Arctic Bay<br />

Mounting Arrangement<br />

Blank=Stand Alone<br />

R=Continuous Row Mount<br />

No of Lamps<br />

4=4 Lamps (AB)<br />

6=6 Lamps (2AB)<br />

Lamp Type<br />

54T5=54W T5HO Lamps (48")<br />

Distribution<br />

Blank=Medium (Specular Aluminum)<br />

G=Wide (White Painted)<br />

Thermal Optimization<br />

The Arctic Bay provides over 90%<br />

of it’s rated light output in ambient<br />

environments down to -15°F (-26°C).<br />

Recommended for use in -20°F<br />

(-29°C) to 32°F (0°C) environments.<br />

Shielding<br />

Blank=Prismatic Acrylic<br />

Lens w/Gasketed Door<br />

Frame<br />

CL=Clear Acrylic Lens<br />

w/Gasketed Door Frame<br />

Voltage (2)<br />

UNV=Universal 120/277 Voltage<br />

UNC=Universal 347/480 Voltage<br />

120V=120 Volt<br />

277V=277 Volt<br />

347V=347 Volt<br />

480V=480 Volt<br />

Options<br />

Lamps Installed<br />

L5835=T5 Lamp, 85CRI 3500K<br />

L5841=T5 Lamp, 85CRI 4100K<br />

L5850=T5 Lamp, 85CRI 5000K<br />

GL=Single Element Fuse<br />

GM=Double Element Fuse<br />

EL=Emergency installed (see table on pg 36) (2)<br />

RELATIVE LIGHT OUTPUT<br />

120%<br />

110%<br />

100%<br />

90%<br />

80%<br />

70%<br />

60%<br />

50%<br />

40%<br />

30%<br />

20%<br />

10%<br />

0<br />

Occupancy sensor: integral high humidity, low temperature<br />

sensor provides 1400 sq. ft. of coverage in mounting heights<br />

up to 40'. MS/OB option keeps two inner lamps illuminated<br />

full time using outer lamps for occupancy control. MS/AO<br />

Option relay rotates on/off cycle between 2 lamp and 4 lamp<br />

ballasts to minimize lamp degradation.<br />

ARCTIC BAY<br />

-15°F (-26°C)<br />

Ballast Type<br />

EBTL =T5 Linear Electronic Program Rapid Start<br />

Total Harmonic Distortion < 10%<br />

Minimum Start Temp -20°F (-29°C)<br />

No of Ballast<br />

1, 2 or 3<br />

DIM=Dimming<br />

Options<br />

C3=3' White Cord Fixture Attached<br />

C6=6' White Cord Fixture Attached<br />

MS/OB=Aisle Modular Sensor Wired with Inner<br />

Two Lamps Constant On (3)<br />

MSO/OB=360° Modular Sensor Wired with<br />

Inner Two Lamps Constant On (3)<br />

MS/AO=Aisle Motion Sensor/Alternate Off<br />

(3) (4)<br />

(Alternate Ballast Relay)<br />

MSO/AO=360° Motion Sensor/Alternate Off<br />

(3) (4)<br />

(Alternate Ballast Relay)<br />

PC3-Voltage=3' Cord/Plug Fixture Attached (2)<br />

PC6-Voltage=6' Cord/Plug Fixture Attached (2)<br />

TCBP=Top Connector Box Plate<br />

-5°F (-20°C) 15°F (-9°C) 35°F (1°C) 55°F (12°C)<br />

AMBIENT TEMPERATURE - DEGREE (F)<br />

Packaging<br />

U=Unit Pack<br />

PAL=Palletized Out of Carton<br />

PALC=Job Pack In Carton<br />

Accessories (order separately)<br />

AYC-CHAIN/SET/U=(2) Hooks, 36" Chain<br />

Sets w/S-Hooks<br />

RH-1=Retrofit Hanger<br />

FH-1=Fixture Hook<br />

FL-1=Fixture Loop<br />

HB-SPS=Single Point Cable Kit<br />

(13" Drop Length)<br />

Gripple Y-=Y Mounting Toggle, #2 Cable<br />

(Specify 10' or 30')<br />

TCB=Top Connector Box<br />

SCA-48=Stem Set Adjustable 48" length<br />

SCF-=Stem Set Fixed (specify length)<br />

SCS=Stem Set 45° Swivel (specify<br />

length)<br />

NOTES: (1) Requires use of voltage specific modular cord assembly See accessories (2) Voltage must be specified when ordered with plugs, motion or emergency ballasts (3) Specify voltage of ballast (4) Requires (2) ballasts Not available in 480V


Mounting Accessories<br />

TCB=Top Connector Box<br />

HB-SPS=Single Point Cable Kit<br />

Dimensions<br />

System Performance<br />

Mounting<br />

Height<br />

40'<br />

Energy<br />

Savings<br />

30'<br />

20'<br />

10'<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

400W MH 400W HPS<br />

50%<br />

3%<br />

FH-1=Fixture Hook 2-1/2"<br />

(must be used with TCB)<br />

HB-SPS=Two Point<br />

Suspension<br />

-21%<br />

51%<br />

2AB-454T5-UNV-EBTL<br />

AB<br />

T5<br />

400W MH 400W HPS<br />

24%<br />

35%<br />

FL-1=Fixture Loop 2-1/2"<br />

(must be used with TCB)<br />

25%<br />

19%<br />

2AB-654T5-UNV-EBTL<br />

RH-1=Retrofit Hanger<br />

(must be used with TCB)<br />

Arctic Bay Lamp Configurations Dimensions for Top View<br />

4-3/4"<br />

[121mm]<br />

AB 4-Lamp 2AB 6-Lamp<br />

X=2-7/8"<br />

[74mm]<br />

X X X<br />

15-7/16" [392mm]<br />

5-1/2"<br />

[140mm]<br />

% light gain/light loss utilize S/P adjusted lumens.<br />

System Performance Table<br />

X=3-1/2"<br />

[89mm]<br />

X X X X X<br />

24" [610mm]<br />

24"<br />

[610mm]<br />

SC-_-_=Stem Sets (fixed,<br />

Swivel or Adjustable<br />

SCF=Fixed<br />

SCA=Adjustable<br />

SCS=Swivel<br />

Photometrics<br />

Access Plate Opening<br />

AYC-Mounting chain set<br />

Coefficients of Utilization<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

Y=Mounting Toggle and<br />

10' or 25' cable<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

2AB-654T5-UNV-EBT2-U<br />

Electronic Ballasts<br />

(6) F54W T5HO lamps 5000 lumens<br />

Spacing criterion: (II) 1 1 x mounting<br />

height, (⊥) 1 2 x mounting height<br />

Efficiency 65 1%<br />

Test Report: BAL13590 IES<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

Mounting for<br />

Top Connector Box 11/16" [18mm] K O<br />

17/64"<br />

Diameter<br />

Hole<br />

48" [1219mm]<br />

78 78 78 78 72 72 72 69 69 69<br />

71 69 66 64 64 63 61 62 60 59<br />

66 61 57 53 57 54 51 55 52 50<br />

60 54 49 45 51 47 44 49 46 43<br />

56 48 43 39 46 42 38 44 41 38<br />

51 44 38 34 42 37 34 40 36 33<br />

48 40 34 30 38 33 30 37 33 30<br />

45 36 31 27 35 30 27 34 30 27<br />

42 33 28 24 32 27 24 31 27 24<br />

39 31 26 22 30 25 22 29 25 22<br />

37 29 24 20 28 23 20 27 23 20<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30<br />

0-40<br />

0-60<br />

0-90<br />

0-180<br />

6856 22 9 35 1<br />

10426 34 8 53 4<br />

16414 54 7 84 0<br />

19532 65 1 100 0<br />

19532 65 1 100 0<br />

Arctic Bay System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4 Wattage LER5 AB-454T5-UNV-EBTL1 4 5000 93% 73% 1.00 13578 1.90 1.38 18716 229 $5.36 60<br />

2AB-654T5-UNV-EBTL2<br />

Comparison System<br />

6 5000 93% 73% 1.00 20367 1.90 1.38 28074 346 $5.40 59<br />

400W Metal Halide High Bay 1 36000 58% 71% 1.00 14825 1.50 1.22 18157 455 $11.29 28<br />

400W High Pressure Sodium High Bay 1 50000 81% 71% 1.00 28755 0.62 0.79 22642 464 $9.24 35<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

2-1/4"<br />

[58mm]<br />

3-1/2"<br />

[89mm]<br />

28


29<br />

VT2/VT3 VAPORTITE INDUSTRIAL<br />

Fiberglass housing is reinforced polyester and self-extinguishing<br />

(ASTM-D635-74) plastic of a permanent pearl gray color.<br />

Polyurethane gasketing is formed in<br />

the housing providing a continuous<br />

seamless seal for the diffuser.<br />

High impact lens options to withstand<br />

the most demanding environments<br />

UL Listed for wet locations<br />

(standard).UL/cUL Listed.<br />

Optional die formed or 95% Specular<br />

Miro finished reflector.<br />

Ordering Information Sample Number: 8TVT2-254DR-UNV-EB82-M4-U<br />

Width<br />

Blank=4' Length<br />

8T=8' Length<br />

Series<br />

VT2=Vaportite<br />

VT3=Vaportite (Gasketed<br />

Enclosure)<br />

Number of Lamps (3)<br />

1=1 lamp (T5 or T8)<br />

2=2 lamps (T5 or T8)<br />

3=3 lamps (T8 only)<br />

(Lamps not included)<br />

Lamp Type<br />

28=28W T5 Lamp (4' Long)<br />

32=32W T8 Lamp (4' Long)<br />

54T5=54W T5HO Lamp (4' Long)<br />

Voltage (1)<br />

120V=120 Volt<br />

277V=277 Volt<br />

347V=347 Volt<br />

480V=480 Volt<br />

UNV=Universal<br />

Voltage 120/277V<br />

UNC=Universal<br />

Voltage 347/480V<br />

Options<br />

GL=Single Element Fuse<br />

GM=Double Element Fuse<br />

EL=Emergency Installed<br />

(see table on pg 36)<br />

Lens<br />

DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard)<br />

DR-50=50% High Impact Additive<br />

DR-100%=100% High Impact Additive (Extreme)<br />

LEX=High Impact Clear Polycarbonate LEXAN Lens/Low Brightness Pattern<br />

NOTES: (1) Ballast type used only if ballast & voltage is chosen (2) Not available when specifying emergency<br />

ballasts, voltage must be specific (3) T5HO is only available in 1 or 2-lamp versions only (4) Emergency<br />

option in 3 lamp version must use remote mount test switch (5) Top Hub required when stem mounting<br />

(6) VT2 only<br />

(3) (4)<br />

No holes required for surface/chain<br />

mounting from supplied mounting<br />

bracket.<br />

A watertite hub for 1/2" conduit entry is<br />

provided at each end of housing (standard)<br />

for continuous feed.<br />

Sturdy cam latches clamp diffuser tightly for a positive seal<br />

between housing, gasketing and diffuser.<br />

Unit has full metal liner (channel) secured by brass internal/external mounting<br />

studs for positive grounding, maximum protection and rigidity.<br />

Ballast Type (1)<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start (4)<br />

Total Harmonic Distortion < 10%<br />

EB8 /PLUS= T8 Electronic Instant Start (4)<br />

WL=Wet<br />

Location<br />

Label<br />

No of Ballast<br />

1 or 2<br />

No of<br />

Ballast<br />

1 or 2<br />

VT3’s EN-SEAL TM<br />

New Architectural Form VT3<br />

gasketing offers IP65<br />

resistance to water absorption.<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

ER8 =T8 Electronic Program Rapid Start (4)<br />

Total Harmonic Distortion < 10%<br />

ER8 /PLUS= T8 Electronic Program Start (4)<br />

No of Ballast<br />

1 or 2<br />

High Ballast Factor >1 15<br />

No of<br />

Total Harmonic Distortion < 10%<br />

Ballast<br />

1 or 2<br />

EB8 /L= T8 Electronic Instant Start<br />

Low Ballast Factor > 0 80<br />

No of Total Harmonic Distortion < 40%<br />

Ballast<br />

1 or 2<br />

T5 Systems<br />

EBT =T5 Electronic Program Start<br />

No of Ballast<br />

1 or 2<br />

EHT =T5HO Linear Electronic Program Rapid Start<br />

High Ambient Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1 or 2<br />

Options<br />

RIF1=Radio<br />

Interference Suppressor<br />

TH=(2) Top Watertite Hubs (5)<br />

TEH=(2) Top & (2) End Watertite<br />

Hubs (all Watertite Hubs have 1/2"<br />

Conduit Entry) (5)<br />

DD=Deep Diffuser (4' Length) (6)<br />

Packaging<br />

U=Unit Pack<br />

PALC=Job Pack<br />

in Carton<br />

(Available for 4' Fixture<br />

Length) To Complement<br />

Deep Diffuser Depth of 5-7/8"<br />

[150mm]<br />

8' Fixture<br />

M4=Specular Reflector<br />

SSL=Stainless Steel Latches<br />

Accessories (order separately)<br />

VT2-Chain/Set-U=Chain Hanging Set<br />

Includes 6 ft of chain, 4 large<br />

S-Hooks and 4 small S-Hooks<br />

Order Two (2) Kits for each<br />

4' or 8' Fixture<br />

VT2-SS-MBK=Stainless<br />

Steel Mounting Bracket<br />

VT2 Stem Bushing=1/2"<br />

3/8" (Required when using<br />

Stem Sets Requires (1) per<br />

Stem Set )


Photometrics<br />

||<br />

⊥<br />

VT2-254DR -UNV-EB81-WL-M4-U<br />

Electronic Ballast<br />

(2) F54/T5/835 Lamps 4460 Lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 6 x mounting height<br />

Efficiency 74 3%<br />

Test Report: 127P111<br />

Dimensions<br />

System Performance<br />

Lamp<br />

Type<br />

Energy<br />

Savings<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

175 MH<br />

45%<br />

30%<br />

150W HPS<br />

VT2-254T5DR-M4<br />

System Performance Table<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

1-lamp 2-lamp<br />

5"<br />

[127mm] X<br />

6-5/8"<br />

[168mm]<br />

7"<br />

[178mm]<br />

Z<br />

Y<br />

5"<br />

[127mm] X<br />

W=2-5/8"<br />

[67mm]<br />

X=2-1/8"<br />

[54mm]<br />

Y=3-3/16"<br />

[81mm]<br />

Z=1-1/2"<br />

[38mm]<br />

87 87 87 87 80 80 80 76 76 76<br />

78 73 70 66 67 64 62 64 61 59<br />

70 63 57 52 58 53 50 55 51 48<br />

64 55 48 43 51 45 41 48 43 40<br />

58 48 41 36 45 39 34 42 38 34<br />

53 43 36 31 40 34 30 38 33 29<br />

49 39 32 27 36 30 26 34 29 25<br />

45 35 28 23 32 27 23 31 26 22<br />

42 32 25 21 30 24 20 28 23 20<br />

39 29 23 18 27 22 18 26 21 18<br />

37 27 21 17 25 20 16 24 19 16<br />

38% 66% 61%<br />

39%<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30<br />

0-40<br />

0-60<br />

0-90<br />

0-180<br />

W<br />

6-5/8"<br />

[168mm]<br />

7"<br />

[178mm]<br />

1411 15 8 21 3<br />

2397 26 9 36 2<br />

4380 49 1 66 2<br />

6268 70 3 94 8<br />

6614 74 2 100 0<br />

Z<br />

Y<br />

6-5/8"<br />

[168mm]<br />

X=5-3/8"<br />

[137mm]<br />

Y=5-3/8"<br />

[102mm]<br />

VT2<br />

175 MH 150W HPS 175 MH 150W HPS<br />

12%<br />

5"<br />

[127mm] X<br />

W<br />

6-5/8"<br />

[168mm]<br />

7"<br />

[178mm]<br />

24%<br />

VT2-232DR-EB8/PLUS-M4<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

49%<br />

42%<br />

43%<br />

50%<br />

VT2-332DR-EB8/PLUS-M4<br />

T5 T8 T8<br />

% light gain/light loss utilize S/P adjusted lumens.<br />

3-lamp (T8 only) Dimensions for Top View<br />

8'<br />

Z<br />

Y<br />

||<br />

4'<br />

6-5/8"<br />

[168mm]<br />

X=5-3/8"<br />

[137mm]<br />

⊥<br />

VT2-232DR-UNV-EB81-WL-M4-U<br />

Electronic Ballast<br />

(2) T8 Lamps 2850 Lumens<br />

Spacing criterion: (II) 1 3 x mounting<br />

height, (⊥) 1 6 x mounting height<br />

Efficiency 81 7%<br />

Test Report: 127P113<br />

X<br />

89-1/2" [2273mm] Optional Back Hub Locations<br />

87-1/16" [2211mm] 1/4" x 28" Stud (4 Places)<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

41-1/2" [1054mm] Optional Back Hub Locations<br />

38-3/4" [984mm] 1/4" x 28" Stud (2 Places)<br />

49-13/16" [1265mm]<br />

X 40-13/16"<br />

5-1/8"<br />

40-13/16"<br />

Y<br />

[1037mm]<br />

[130mm]<br />

97-13/16" [2484mm]<br />

[1037mm]<br />

Design S/P<br />

Vaportite Comparison No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

96 96 96 96 87 87 87 82 82 82<br />

86 81 77 73 74 70 68 69 67 64<br />

77 69 63 58 63 58 54 60 56 52<br />

70 60 53 47 55 49 45 52 47 43<br />

64 53 45 40 49 43 38 46 41 37<br />

58 47 39 34 44 37 32 41 36 31<br />

54 42 35 29 39 33 28 37 32 27<br />

50 38 31 26 35 29 25 34 28 24<br />

46 35 28 23 32 26 22 31 25 21<br />

43 32 25 20 30 24 20 28 23 19<br />

40 29 23 18 27 22 18 26 21 17<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 985 17 3 21 1<br />

0-40 1675 29 4 36 0<br />

0-60 2999 52 6 64 4<br />

0-90 4316 75 7 92 7<br />

0-180 4658 81 7 100 0<br />

(Specular Reflector) Lamps Lumens Maintenance 1 Efficiency Factor Lumens 2 Ratio 3 Perception Lumens 4 Wattage LER 5<br />

VT2-254T5DR-M4 2 5000 93% 74% 1.00 6910 1.90 1.50 6910 117 $5.29 60<br />

VT2-232DR-EB8/PLUS-M4 2 3100 94% 82% 1.15 5476 1.95 1.40 7646 73 $3.25 98<br />

VT2-332DR-EB8/PLUS-M4 3 3100 94% 82% 1.15 8214 1.95 1.40 11470 108 $7.43 43<br />

Comparison System<br />

175W Metal Halide Garage Light 1 13600 58% 70% 1.00 5474 1.50 1.22 6705 213 $14.65 22<br />

150W High Pressure Sodium Garage Light 1 12900 81% 70% 1.00 7335 0.62 0.79 5776 188 $14.84 22<br />

Y<br />

Y=5-3/8"<br />

[102mm]<br />

30


31<br />

ECOFIT – STRIPS ENERGY EFFICIENT CONVERSION KITS<br />

Description<br />

Ecofit conversion kits are an<br />

economical means of increasing<br />

fixture efficiency and energy<br />

savings. Ecofit conversion kits<br />

are ideal for applications where<br />

fixture removal is cost-prohibitive.<br />

Ecofit conversion kits are<br />

designed for applications with<br />

conventional 1 or 2-lamp<br />

strip/channel fixtures, such as<br />

task, coves, display cases, utility,<br />

and general area lighting.<br />

Construction<br />

Socket tracks are die formed 20<br />

gauge cold rolled steel. Toolless<br />

ballast access for easy wiring<br />

access and installation<br />

Optical Modules<br />

Die formed reflectors faceted for 1 and 2 lamp configurations with<br />

two optical distributions medium and wide. Medium beam optical<br />

modules utilize 95% specular Miro 4 substrate while the wide<br />

distribution utilizes a high performance 91% reflective polyester<br />

powder coated finish.<br />

Ordering Information Sample Number: ECS-232-M-UNV-EB81-10B<br />

Width<br />

Blank=4'<br />

8=8'<br />

Series<br />

ECS=Ecofit Strip<br />

No of Lamps<br />

1=1 Lamp<br />

2=2 Lamps<br />

Lamp Type<br />

32=32W T8 Lamp (48")<br />

54=54W T5HO Lamp (48")<br />

Optics<br />

M=Medium (Specular<br />

Aluminum)<br />

W=Wide (White Painted)<br />

Electrical<br />

Optional electronic ballasts are Class<br />

“P” and are positively secured by<br />

mounting bolts. Twist-lock lampholders.<br />

UL/cUL listed. Suitable for damp<br />

locations.<br />

Voltage<br />

NB=No Ballast<br />

UNV=Universal Voltage<br />

Ballast Included<br />

Ballast/Socket Type<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start (1)<br />

Total Harmonic Distortion < 10%<br />

EB8 /PLUS=T8 Electronic Instant Start (1)<br />

No of Ballast<br />

1, 2 or Blank<br />

No of<br />

Ballast<br />

1 or 2<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

EB8 /L=T8 Electronic Instant Start w/ < 0 80 (1)<br />

Ballast Factor Total Harmonic<br />

Distortion < 10%<br />

ER8 =T8 Electronic Program Rapid Start (1)<br />

No of<br />

Ballast<br />

1 or 2<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1, 2 or Blank<br />

ER8 /PLUS= T8 Electronic Program Rapid Start<br />

No of<br />

Ballast<br />

1 or 2<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

T5 Systems<br />

EBT =T5HO Electronic Program Start<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1 or 2<br />

NOTES: (1) When using Ecofit Kits without ballasts, indicate ballast type and system to designate shunted or unshunted sockets Ex: ECS-232-M-NB-EB8-10B<br />

Mounting<br />

Retrofit installation in standard 4' and<br />

8' strip lengths and fits channels 4" to<br />

5-5/8" wide. Hardware included. Kits<br />

are bulk packed for easier handling.<br />

Packaging<br />

10B=10 Pack Quantities<br />

80B=80 Pack Quantities<br />

U=Unit Pack


Photometrics<br />

System Performance Table<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

ECS-132-M-EB81<br />

Electronic Ballast<br />

(1) 32W T8 2900 lumens<br />

Spacing criterion: (II) 1 3 x mounting<br />

height, (⊥) 1 5 x mounting height<br />

Efficiency 91 7%<br />

Test Report: ECS132MEB81<br />

Installation<br />

1-Lamp<br />

System Performance<br />

Energy<br />

Savings<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

Strip ECOFIT<br />

2 LAMP T12 2 LAMP T12<br />

SL<br />

51%<br />

9%<br />

ECS-132-<br />

M-EB81<br />

109 109 109 109 102 102 102 97 97 97<br />

97 92 87 83 86 82 79 82 79 76<br />

87 79 71 65 73 68 63 70 65 61<br />

79 68 60 53 64 57 51 61 55 50<br />

72 60 51 44 56 49 43 54 47 42<br />

66 53 44 37 50 42 36 48 41 36<br />

60 47 38 32 45 37 32 43 36 31<br />

56 43 34 28 40 33 28 39 32 27<br />

52 39 31 25 37 30 25 36 29 24<br />

49 36 28 22 34 27 22 33 26 22<br />

45 33 25 20 31 24 20 30 24 20<br />

42%<br />

1%<br />

8ECS-132-<br />

M -<br />

EB81/PLUS<br />

% light gain/light loss utilize<br />

S/P adjusted lumens.<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 571 19 7 21 5<br />

0-40 952 32 8 35 8<br />

0-60 1809 62 4 68 0<br />

0-90 2645 91 2 99 4<br />

0-180 2661 91 7 100 0<br />

2-Lamp<br />

Reflector Dimensions<br />

5-1/8"<br />

[131mm]<br />

2"<br />

[51mm]<br />

X X=2-1/2"<br />

[64mm]<br />

10-5/8"<br />

[270mm]<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

ECS-232-M-EB81<br />

Electronic Ballast<br />

(2) 32W T8 2900 lumens<br />

Spacing criterion: (II) 1 3 x mounting<br />

height, (⊥) 1 4 x mounting height<br />

Efficiency 89 4%<br />

Test Report: ECS232MEB81<br />

106 106 106 106 99 99 99 95 95 95<br />

96 91 86 82 85 81 78 81 78 76<br />

86 78 71 65 73 67 63 70 65 61<br />

78 68 60 53 63 57 52 61 55 51<br />

71 59 51 44 56 49 43 54 48 43<br />

65 53 44 38 50 43 37 48 42 37<br />

60 47 39 33 45 38 32 43 37 32<br />

55 43 35 29 41 33 28 39 33 28<br />

52 39 31 25 37 30 25 36 30 25<br />

48 36 28 23 34 27 23 33 27 22<br />

45 33 25 21 31 25 20 30 25 20<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 1194 20 6 23 0<br />

0-40 1983 34 2 38 2<br />

0-60 3682 63 5 71 0<br />

0-90 5161 89 0 99 5<br />

0-180 5185 89 4 100 0<br />

All components (reflectors, socket brackets, sockets, screws, and wire nuts)<br />

are included in each kit for installation and require only a few basic tools<br />

for assembly.<br />

Design S/P<br />

<strong>Industrial</strong> & Channel (Strip) No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

$0.08 kWh<br />

Ecofit Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4 Wattage LER5 ECS-132-M-EB81 1 3100 94% 89% 1.15 2993 1.95 1.40 4179 46 $3.43 93<br />

8ECS-132-M-EB81/PLUS<br />

Comparison System<br />

2 3100 94% 89% 1.15 5985 1.95 1.40 8358 73 $2.72 118<br />

2L T12 Strip 2 2750 88% 71% 0.90 3093 1.50 1.22 3788 94 $12.43 26<br />

2L T12 SL Strip 2 5330 93% 79% 0.88 6883 1.50 1.22 8430 126 $6.89 46<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

32


33<br />

ECOFIT – TROFFERS ENERGY EFFICIENT CONVERSION KITS<br />

Description<br />

Ecofit conversion kits are an<br />

economical means of increasing<br />

fixture efficiency and energy<br />

savings. Ecofit conversion kits<br />

are ideal for applications where<br />

fixture removal is cost-prohibitive.<br />

Ecofit conversion kits are<br />

designed for applications with<br />

conventional 3 or 4-lamp recessed<br />

2' x 4' fixtures. Retrofitting 3 and<br />

4-lamp troffers to 2-lamps with<br />

high performance retrofit<br />

conversion kits can reap up to<br />

50% energy savings.<br />

Construction<br />

Socket tracks are die formed 20<br />

gauge cold rolled steel. Toolless<br />

ballast access for easy wiring<br />

access and installation.<br />

Optical Modules<br />

Die formed reflectors are faceted for 2 lamp configuration with<br />

two optical distributions medium and wide. Medium beam optical<br />

modules utilize 95% specular Miro 4 substrate while the wide<br />

distribution utilizes a high performance 91% reflective polyester<br />

powder coated finish.<br />

Ordering Information Sample Number: 2ECT-217-M-UNV-EB81-10B<br />

Width<br />

2=24" Wide (only)<br />

Series<br />

ECT=Ecofit Troffer<br />

No of Lamps<br />

2=2 Lamps<br />

3=3 Lamps<br />

Lamp Type<br />

17=17W T8 Lamp (24")<br />

32=32W T8 Lamp (48")<br />

24=24W T5HO Lamp (24")<br />

54=54W T5HO Lamp (48")<br />

Optics<br />

M=Medium (Specular<br />

Aluminum)<br />

W=Wide (White Painted)<br />

Electrical<br />

Optional electronic ballasts are Class<br />

“P” and are positively secured by<br />

mounting bolts. Twist-lock lampholders. (1)<br />

UL/cUL listed. Suitable for damp<br />

locations.<br />

Voltage<br />

NB=No Ballast<br />

UNV=Universal Voltage<br />

Ballast Included<br />

NOTES: (1) When using Ecofit Kits without ballasts, indicate ballast type and system to designate shunted or unshunted sockets Ex: 2ECT-232-M-NB-EB8-10B<br />

Ballast/Socket Type<br />

T8 Systems<br />

EB8 =T8 Electronic Instant Start (1)<br />

Total Harmonic Distortion < 10%<br />

EB8 /PLUS= T8 Electronic Instant Start (1)<br />

No of Ballast<br />

1, 2 or Blank<br />

T5 Systems<br />

EBT =T5HO Electronic Program Start<br />

Total Harmonic Distortion < 10%<br />

No of Ballast<br />

1, 2 or Blank<br />

Mounting<br />

Retrofit installation in standard 2' x 2'<br />

and 2' x 4' recessed troffers.<br />

Hardware included.<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

ER8 =T8 Electronic Program Rapid Start (1)<br />

Total Harmonic Distortion < 10%<br />

ER8 /PLUS= T8 Electronic Program Rapid Start (1)<br />

High Ballast Factor >1 15<br />

Total Harmonic Distortion < 10%<br />

EB8 /L=T8 Electronic Instant Start w/ < 0 80 (1)<br />

No of<br />

Ballast<br />

1 or 2<br />

No of Ballast<br />

1, 2 or Blank<br />

No of<br />

Ballast<br />

1 or 2<br />

Ballast Factor Total Harmonic<br />

No of Distortion < 10%<br />

Ballast<br />

1 or 2<br />

Packaging<br />

10B=10 Pack Quantities<br />

80B=80 Pack Quantities<br />

U=Unit Pack


Photometrics<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

ECT-332-W-EB81<br />

Electronic Ballast<br />

(3) FO32/841 lamps 2850 lumens<br />

Spacing criterion: (II) 1 3 x mounting<br />

height, (⊥) 1 4 x mounting height<br />

Efficiency 88 1%<br />

Test Report: ECT332WEB81<br />

Installation<br />

System Performance<br />

Energy<br />

Savings<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

System Performance Table<br />

105 105 105 105 98 98 98 94 94 94<br />

95 91 87 84 85 82 80 82 79 77<br />

86 79 73 67 74 69 65 71 67 63<br />

78 69 61 55 65 59 54 62 57 53<br />

72 61 53 47 57 51 46 55 50 45<br />

66 54 46 40 51 44 39 49 43 39<br />

61 48 40 35 46 39 34 45 38 34<br />

56 44 36 30 42 35 30 40 34 30<br />

52 40 32 27 38 31 27 37 31 27<br />

49 37 29 24 35 29 24 34 28 24<br />

46 34 27 22 32 26 22 32 26 22<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30<br />

0-40<br />

0-60<br />

0-90<br />

0-180<br />

Troffer ECOFIT<br />

3 LAMP T12 4 LAMP T12 3 LAMP T12 4 LAMP T12<br />

44%<br />

37%<br />

54%<br />

3%<br />

ECT-232-M-EB81/PLUS<br />

1907 22 3 25 3<br />

3152 36 9 41 8<br />

5753 67 3 76 4<br />

7534 88 1 100 0<br />

7534 88 1 100 0<br />

All components (reflectors, socket brackets, sockets, screws, and wire<br />

nuts) are included in each kit for installation and require only a few<br />

basic tools for assembly.<br />

44%<br />

34%<br />

-1%<br />

54%<br />

ECT-232-W-EB81/PLUS<br />

% light gain/light loss utilize S/P adjusted lumens.<br />

3 LAMP T12 4 LAMP T12 3 LAMP T12 4 LAMP T12<br />

55%<br />

17% -27%<br />

ECT-232-M-EB82<br />

64%<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

ECT-232-M-EB81<br />

Electronic Ballast<br />

(2) 32W T8 F32T8/TL841 lamps 3050 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 1 x mounting height<br />

Efficiency 88%<br />

Test Report: ECT232MEB81<br />

105 105 105 105 98 98 98 94 94 94<br />

97 93 89 86 87 85 82 84 82 80<br />

89 82 77 73 78 74 70 75 71 68<br />

82 74 67 62 70 65 60 67 63 59<br />

76 66 59 54 63 57 53 61 56 52<br />

70 60 52 47 57 51 46 55 50 46<br />

65 54 47 42 52 46 41 51 45 41<br />

61 50 42 37 48 41 37 46 41 37<br />

57 46 39 34 55 45 38 34 37 33<br />

53 42 35 31 41 35 30 40 34 30<br />

50 39 32 28 38 32 28 37 32 28<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 1896 31 1 35 3<br />

0-40 2988 49 0 55 7<br />

0-60 4632 75 9 86 3<br />

0-90 5366 88 0 100 0<br />

0-180 5366 88 0 100 0<br />

Reflector Dimensions<br />

9-3/4" [248mm]<br />

19-13/16"<br />

[505mm]<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 4100K lamps 5 ECT-232-M-EB8/PLUS 2 3100 94% 88% 1.15 5898 1.95 1.68 8236 73<br />

$0.08 kWh<br />

$2.80 114<br />

ECT-232-W-EB8/PLUS 2 3100 94% 85% 1.15 5683 1.95 1.68 7937 73 $3.02 106<br />

ECT-232-M-EB81 2 3100 94% 88% 0.88 4513 1.95 1.68 6302 58 $3.80 84<br />

ECT-232-W-EB81<br />

Comparison System<br />

2 3100 94% 85% 0.88 4349 1.95 1.68 6073 58 $4.10 78<br />

3L T12 Parabolic 3 2750 88% 65% 0.90 4247 1.50 1.22 5202 130 $13.67 23<br />

4L T12 Troffer 4 2750 88% 75% 0.90 6534 1.50 1.22 8002 160 $9.48 34<br />

LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

55%<br />

14% -32%<br />

ECT-232-W-EB82<br />

64%<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

Troffer Ecofit Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens 2 Ratio 3 Perception Lumens 4 Wattage LER 5<br />

X<br />

X=1-7/8"<br />

[48mm]<br />

34


35<br />

Lamp Options<br />

OPTIONS & ACCESSORIES<br />

Brand Lamp HB/2HB I5 I8 MB (1) 3HBO/3HBOT HBG HBHD AB VT2 (1) VT3 (1)<br />

Generic L8730 X X X X X X X X<br />

L8735 X X X X X X X X<br />

L8741 X X X X X X X X<br />

LB30<br />

LB35<br />

LB41<br />

L5830 X X X X X X X X X<br />

L5835 X X X X X X X X X<br />

L5841 X X X X X X X X X<br />

GE LGSP30M/OC8 (GE) X X X X X X X X<br />

LGSP35M/OC8 (GE) X X X X X X X X<br />

LGSP41M/OC8 (GE) X X X X X X X X<br />

LGSPX30M/OC8 (GE) X X X X X X X X<br />

LGSPX35M/OC8 (GE) X X X X X X X X<br />

LGSPX41M/OC8 (GE)<br />

LGF24T5M/830 (GE)<br />

LGF24T5M/835 (GE)<br />

LGF24T5M/841 (GE)<br />

X X X X X X X X<br />

LGF28T5M/830 (GE) X X X X X X<br />

LGF28T5M/835 (GE) X X X X X X<br />

LGF28T5M/841 (GE) X X X X X X<br />

LGF54T5M/830 (GE) X X X X X X X X X<br />

LGF54T5M/835 (GE) X X X X X X X X X<br />

LGF54T5M/841 (GE) X X X X X X X X X<br />

Philips LWF17T8M/TL730 (Philips)<br />

LWF17T8M/TL735 (Philips)<br />

LWF17T8M/TL741 (Philips)<br />

LWF32T8M/TL730 (Philips) X X X X X X<br />

LWF32T8M/TL735 (Philips) X X X X X X<br />

LWF32T8M/TL741 (Philips)<br />

LWF17T8M/TL830 (Philips)<br />

LWF17T8M/TL835 (Philips)<br />

LWF17T8M/TL841 (Philips)<br />

X X X X X X<br />

LWF32T8M/TL830 (Philips) X X X X X X X<br />

LWF32T8M/TL835 (Philips) X X X X X X X<br />

LWF32T8M/TL841 (Philips)<br />

LWF24T5M/830 (Philips)<br />

LWF24T5M/835 (Philips)<br />

LWF24T5M/841 (Philips)<br />

X X X X X X X<br />

LWF28T5M/830 (Philips) X X X X X X<br />

LWF28T5M/835 (Philips) X X X X X X<br />

LWF28T5M/841 (Philips) X X X X X X<br />

LWF54T5M/830 (Philips) X X X X X X X X X<br />

LWF54T5M/835 (Philips) X X X X X X X X X<br />

LWF54T5M/841 (Philips) X X X X X X X X X<br />

Sylvania LSFO17M/730K (OSI)<br />

LSFO17M/735K (OSI)<br />

LSFO17M/741K (OSI)<br />

LSFO17M/830K (OSI)<br />

LSFO17M/835K (OSI)<br />

LSFO17M/841K (OSI)<br />

LSFO32M/730K (OSI) X X X X X X X X<br />

LSFO32M/735K (OSI) X X X X X X X X<br />

LSFO32M/741K (OSI) X X X X X X X X<br />

LSFO32M/830K (OSI) X X X X X X X X<br />

LSFO32M/835K (OSI) X X X X X X X X<br />

LSFO32M/841K (OSI)<br />

LSF24T5M/830 (OSI)<br />

LSF24T5M/835 (OSI)<br />

LSF24T5M/841 (OSI)<br />

X X X X X X X X<br />

LSF28T5M/830 (OSI) X X X X X X<br />

LSF28T5M/835 (OSI) X X X X X X<br />

LSF28T5M/841 (OSI) X X X X X X<br />

LSF54T5M/830 (OSI) X X X X X X X X X<br />

LSF54T5M/835 (OSI) X X X X X X X X X<br />

LSF54T5M/841 (OSI) X X X X X X X X X<br />

NOTES: (1) Lamps supplied, not installed


Emergency Options<br />

Nomenclature Description HB/2HB I5 I8 MB 3HBO/3HBOT HBG HBHD AB VT2 VT3<br />

Generic EL4 (350-450 Im) X X X X X X X X X<br />

EL8 (600-700 Im) X X X X X X X X X<br />

Sure-Lites EL-FBP140X (350-450 Im) X X X X X X X X<br />

EL-FBP240U (600-700 Im) X X X X X X X X<br />

EL-FBP240M (600-700 Im) X X X X X X X X<br />

EL-FBP240H (1100-1400 Im) X X X X X X X X<br />

Bodine EL-B100 (350-450 Im) X X X X X X X X<br />

EL-B90 (500-600 Im) X X X X X X X X<br />

EL-B70A (600-700 Im) X X X X X X X X<br />

EL-B60 (600-700 Im) X X X X X X X X<br />

EL-B60U (600-700 Im) X X X X X X X X<br />

EL-B50 (1100-1400 Im) (1) X X X X X X X X<br />

EL-B50U (1100-1400 Im) (1) X X X X X X X X<br />

EL-B50ST (1100-1400 Im) (1) X X X X X X X X<br />

EL-B50RCT (1100-1400 Im) (1) X X X X X X X X<br />

Iota EL-I32 (up to 550 Im) X X X X X X X X X<br />

EL-I40 (up to 700 Im) X X X X X X X X<br />

EL-I48 (up to 700 Im) X X X X X X X X<br />

EL-I320 (1300 Im) (1) X X X X X X X X X<br />

EL-I880 (2000 Im) (1) X X X X X X X X X<br />

EL-I232 (2 @ 1400 Im) X X X X X X X X X<br />

EL-ISD80 (1300 Im) (1) (2) X X X X X X X X X<br />

EL-I40DL (up to 700 Im) (2) X X X X X X X X X<br />

EL-I48DL (up to 700 Im) (2) X X X X X X X X X<br />

EL-I80DL (1300 Im) (2) X X X X X X X X X<br />

EL-I232DL (2 @ 1400 Im) (2) X X X X X X X X X<br />

NOTES: (1) For battery wired to two lamps, specify “/2L” after battery description (2) Approved for wet location listing<br />

F-Bay Mounting Accessories<br />

Gripple Gripple Gripple<br />

Fixture TCB/ TCB/ TCB/ TCB/ Single “Y” Loop<br />

Series AYC STEM RH-1 FH-1 FL-1 HB-SPS Toggle Toggle Hanger<br />

HB X X X X X X X<br />

2HB X X X X X X X<br />

3HBO/3HBOT X X X X X X X<br />

I5 X X X X X X X X<br />

I8 X X X X X X X X<br />

AB X X X X X X X<br />

MB X X X<br />

Packaging Options<br />

Nomenclature Description HB/2HB I5 I8 MB 3HBO/3HBOT HBG HBHD AB VT2 VT3<br />

U Unit Pack X X X X X X X X X X<br />

PAL Palletized out of carton on a X X X X (3) X X X<br />

25" x 48" pallet, shrink wrapped<br />

PALC Palletized in carton on a X X X X (3) X X X X X<br />

25" x 48" pallet, shrink wrapped<br />

NOTES: (3) Pallet size is 40" x 58"<br />

36


37<br />

Mounting<br />

MOUNTING ACCESSORIES DESIGNATION DESCRIPTION<br />

Top Connector Box<br />

TCB= Top Connector Box (Includes Plate)<br />

TCBP= Top Connector Box Plate (Mounted on fixture)<br />

HB-TCB-KIT-U= Complete TCB Kit (Supplied Separately)<br />

HB-TCB-KIT-NO-PLATE-U= Kit for Fixture w/TCBP Installed<br />

SIDE FRONT TOP<br />

2-5/16"<br />

[59mm]<br />

4-11/16"<br />

[120mm]<br />

3-9/16"<br />

[91mm]<br />

Accessories (order separately)<br />

SC = Stem Set (Order Two Per Fixture)<br />

Length: 6", 8", 12", 24", 36", 48", 60", 72")<br />

F=Fixed<br />

S=45° Swivel<br />

A=Adjustable (48" Only)<br />

X<br />

4-11/16" [120mm]<br />

Suitable for conduit mounting or for<br />

use with fixture hook, loop or safety<br />

hook. Use chain or cable set to<br />

meet NEC requirements for single<br />

point mounting, as well as to prevent<br />

cantilevering and rotation of fixture<br />

from one central location.<br />

Ideal for Retrofit opportunities!<br />

X=2-11/32"<br />

[60mm]<br />

MOUNTING METHODS DESIGNATION DESCRIPTION<br />

Hook and Safety Hook<br />

3-3/8"<br />

[86mm]<br />

1-3/16"<br />

[31mm]<br />

FH–1= Fixture Hook<br />

1-7/8"<br />

[48mm]<br />

1"<br />

[26mm]<br />

TOP<br />

1-1/2" HEX.<br />

[39mm]<br />

MOUNTING METHODS DESIGNATION DESCRIPTION<br />

Loop<br />

FL–1= Fixture Loop<br />

MOUNTING METHODS DESIGNATION DESCRIPTION<br />

Retrofit Hanger<br />

MOUNTING METHODS DESIGNATION DESCRIPTION<br />

Stem<br />

RH–1= Retrofit Hanger<br />

Fixture Hook 2-1/2" (must be used<br />

with TCB)<br />

Fixture Loop 2-1/2" (must be used<br />

with TCB)<br />

Cast Aluminum Hanger w/Toggle<br />

Nut & Carriage Bolt for quick<br />

installation (must be used with TCB)<br />

Fixed, swivel or adjustable stem<br />

sets are available in various lengths.


Mounting<br />

MOUNTING METHODS DESIGNATION DESCRIPTION<br />

AYC Chain Set<br />

AYC–Chain/Set–U=Mounting chain set (3)<br />

MOUNTING METHODS DESIGNATION DESCRIPTION<br />

“Y” Toggle<br />

Gripple–Y–10=Mounting Toggle and 10' Cable<br />

Gripple–Y–-25=Mounting Toggle and 25' Cable<br />

(2) sturdy Wire Hooks and 36" Chain<br />

Sets w/S-hooks<br />

10', Y Toggle #2 Cable<br />

25', Y Toggle #2 Cable<br />

MOUNTING METHODS DESIGNATION DESCRIPTION<br />

Loop Hanger/Single Toggle<br />

Loop Hanger Single Toggle<br />

SPS Cable Kit<br />

SINGLE POINT TWO<br />

POINT<br />

Note: Not for use in high abuse areas such as gymnasiums or similar recreational facilities.<br />

(1) (2)<br />

HB–SPS<br />

Gripple–Loop–10<br />

Gripple–Loop–30<br />

Gripple–Toggle–10<br />

Gripple–Toggle–30<br />

10' Loop Hanger #2 Cable<br />

30' Loop Hanger #2 Cable<br />

10' Single Toggle #2 Cable<br />

30' Single Toggle #2 Cable<br />

MOUNTING METHODS DESIGNATION DESCRIPTION<br />

NOTES: (1) Only one required per fixture (2) Fixture Hook not included<br />

Single Point Cable Kit= Stainless<br />

Steel Cable Kit for single point<br />

suspension. (Fixture dropped below<br />

mounting point by 13")<br />

Two Point Suspension= (Fixture<br />

dropped below mounting point by 29")<br />

Note: Not for use in high abuse areas such as gymnasiums or similar<br />

recreational facilities.<br />

38


39<br />

Occupancy Sensors<br />

OCCUPANCY SENSORS DESIGNATION DESCRIPTION<br />

CPD-1200H<br />

MS= Aisle Coverage Occupancy Sensor (120V-277V) (1)<br />

OCCUPANCY SENSORS DESIGNATION DESCRIPTION<br />

CPD-500H<br />

MMS-CPD1200H= Aisle Motion Sensor for<br />

Modular Power <strong>Supply</strong> Option (120V/277V) (1)<br />

ENDPLATE<br />

X=Height<br />

4-5/8"<br />

[118mm]<br />

X<br />

Length<br />

4-5/8"<br />

[118mm]<br />

NOTES: (1) One motion sensor per fixture required<br />

Width<br />

4-5/8"<br />

[118mm]<br />

MSO= 360° Coverage Occupancy Sensor (120V-277V) (1)<br />

MMS-CPD500H= 360° Motion Sensor for<br />

Modular Power <strong>Supply</strong> Option (120V/277V) (1)<br />

NOTES: (1) One Motion Sensor per fixture required<br />

CPD-1200 Aisle Coverage Occupancy<br />

Sensor (120V-277V)<br />

(Rectangular Beam, Pattern Coverage)<br />

600'<br />

sq ft<br />

40' Height<br />

Supplied with Mounting Box and<br />

Modular Power <strong>Supply</strong> Receptacle.<br />

600' sq. ft.<br />

For use with MP option<br />

CPD-500 360° Coverage Occupancy<br />

Sensor (120V-277V)<br />

(360° Circular Pattern Coverage)<br />

Approximately<br />

1250 sq ft<br />

@ 40 ft<br />

Supplied with Mounting Box and<br />

Modular Power <strong>Supply</strong> Receptacle<br />

For use with MP option


Power Connections<br />

POWER CONNECTIONS DESIGNATION DESCRIPTION<br />

PC3, PC6<br />

PC3= 3' Power Cord & Plug (specify voltage for plug)<br />

PC6= 6' Power Cord & Plug (specify voltage for plug)<br />

MPC3=3' Modular Power Cord & Plug<br />

MPC6=6' Modular Power Cord & Plug<br />

POWER CONNECTIONS DESIGNATION DESCRIPTION<br />

C3, C6<br />

POWER CONNECTIONS DESIGNATION DESCRIPTION<br />

MWS<br />

PI OPTION ORDERING INFORMATION<br />

Catalog Number Number of Circuit Wired<br />

Suffix Circuits To Ballast<br />

PI 1 BLK 1 Black<br />

PI 2 BLU 2 Blue<br />

PI 2 BLK 2 Black<br />

PI 3 RED 3 Red<br />

PI 3 BLU 3 Blue<br />

PI 3 BLK 3 Black<br />

PI1 - Single Circuit Plug-In<br />

SAMPLE NUMBER: PI1BLK-WG<br />

PI1= Single<br />

Circuit<br />

BLK=Black Hot<br />

NG= No Ground (ground<br />

provided by fixture body)<br />

WG= With Ground<br />

(separate ground wire<br />

in harness)<br />

For complete product data, reference the <strong>Fluorescent</strong><br />

Specification binder Specifications & dimensions subject to<br />

change without notice Consult your Cooper Lighting<br />

Representative for availability and ordering information<br />

PI2= Two<br />

Circuit<br />

C3= 3' Cord<br />

C6= 6' Cord<br />

MC3=3' Cord<br />

MC6=6' Cord<br />

MWS= Modular Wiring System<br />

MDS6= 6' Modular Power Cord<br />

with MWS<br />

PI2 - Two Circuit Plug-In<br />

SAMPLE NUMBER: PI2BLK-WG<br />

BLK=Black Hot<br />

BLU=Blue Hot<br />

Leave Blank=Single<br />

Neutral<br />

/WHT=White Neutral<br />

/GRY=Gray Neutral<br />

Leave Blank=Single Neutral<br />

2NEU=Two Neutrals<br />

NG= No Ground (ground<br />

provided by fixture body)<br />

WG= With Ground (separate<br />

ground wire in harness)<br />

PC3 – 3' long Cord & Plug set w/NEMA<br />

L515 or L715 twist lock plug (white)<br />

PC6 – 6' long Cord & Plug set w/NEMA<br />

L515 or L715 twist lock plug (white)<br />

MPC3=3' long Modular Cord & Plug set<br />

w/NEMA L/515 or L715 twist lock plug -<br />

white. Use with MP option.<br />

MPC6=6' long Modular Cord & Plug set<br />

w/NEMA L/515 or L715 twist lock plug -<br />

white. Use with MP option.<br />

C3 – 3' long 3/16 STW white Power Cord<br />

C6 – 6' long 3/16 STW white Power Cord<br />

MC3 – 3' long 3/16" Standard Modular Power Cord.<br />

For use with MP option.<br />

MC6 – 6' long 3/16" Standard Modular Power Cord.<br />

For use with MP option.<br />

MWS is a simple and cost effective modular wiring system<br />

consisting of factory assembled components.<br />

MWS arrives at the job site ready to be snapped together<br />

into a complete branch circuit wiring system.<br />

With MWS, branch circuit wiring can be installed in minutes<br />

instead of hours.<br />

Reduces labor by 80% for lowest total installed cost.<br />

Fixtures and wiring are portable for future flexibility.<br />

27DS18/2G06MP Connect directly to F-Bay or Motion Sensor<br />

Catalog Numbering System<br />

The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections<br />

together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows:<br />

PI-1 = One Circuit - 2 Wires: one black, one white<br />

PI-2 = Two Circuits - 3 Wires: one black, one blue, one white<br />

PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white<br />

When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. All<br />

wiring to external feeds, using cord or cord & plug, are responsibility of installing licensed contractor. Cord and<br />

cord & plug sets must be ordered separately if PI option is chosen.<br />

PI3 - Three Circuit Plug-In<br />

SAMPLE NUMBER: PI3BLK-WG<br />

PI3= Three<br />

Circuit<br />

BLK=Black Hot<br />

BLU=Blue Hot<br />

RED=Red Hot<br />

Leave Blank=Single Neutral<br />

/WHT=White Neutral<br />

/GRY=Gray Neutral<br />

Leave Blank=Single Neutral<br />

2NEU=Two Neutrals<br />

NG= No Ground (ground provided by<br />

fixture body)<br />

WG= With Ground (separate ground<br />

wire in harness)<br />

40


41<br />

I5/I8 Lens, Door Frames and Wireguards<br />

I5/I8 LENS DESIGNATION DESCRIPTION<br />

FROSTED ACRYLIC LENS<br />

HEAVY DUTY WIREGUARD<br />

I5-FRM/LENS= Frosted Acrylic Lens & Frame<br />

(use with general distribution reflector, I5 only)<br />

I8-FRM/LENS= Frosted Acrylic Lens & Frame<br />

(use with general distribution reflector, I8 only)<br />

I5-FRM/CL PK= Clear Acrylic Lens & Frame<br />

(use with general distribution reflector, I5 only)<br />

I8-FRM/CL PK= Clear Acrylic Lens & Frame<br />

(use with general distribution reflector, I8 only)<br />

I5/I8 WIREGUARD DESIGNATION DESCRIPTION<br />

WG/I5-4FT-B= 4' Heavy Duty Wireguard (for I5)<br />

WG/I8-4FT-B= 4' Heavy Duty Wireguard (for I8)<br />

I5/I8 BAFFLE DESIGNATION DESCRIPTION<br />

TBW<br />

90800PPK= 4' Thin Blade White Baffle (for I5)<br />

BAFFLE 4FT I8 (WHITE) 11571919= 4' Thin Blade<br />

White Blade Baffle (for I8)<br />

I5/I8 LOUVER DESIGNATION DESCRIPTION<br />

ASYMMETRIC LOUVER<br />

90801PPK= Asymmetric Directional Louver<br />

(use with general distribution reflector)<br />

In white door frame w/”Herringbone”<br />

patterned end rail<br />

Finished in white. Can be used alone or<br />

in combination with other shielding<br />

Thin Blade White Baffle w/23° longitudinal<br />

shielding<br />

Can be oriented in either direction for<br />

flexibility


HB/2HB Lens, Door Frames and Wireguards<br />

HB/2HB LENS & DOOR FRAME DESIGNATION DESCRIPTION<br />

PRISMATIC & CLEAR ACRYLIC<br />

LENS & DOOR FRAME<br />

HB/2HB LENS & WIREGUARD DESIGNATION<br />

WIREGUARD<br />

HB/2HB DROP WIREGUARD DESIGNATION<br />

DROP WIREGUARD<br />

HB-FRM/LENS PK= Prismatic Acrylic Lens & Door Frame for HB<br />

(use with general distribution reflector)<br />

2HB-4-A W/FRM PK= Prismatic Acrylic Lens & Door Frame for 2HB<br />

(use with general distribution reflector)<br />

HB-FRM/CL PK= Clear Acrylic Lens & Door Frame for HB<br />

2HB-FRM/CL PK= Clear Acrylic Lens & Door Frame for 2HB<br />

HB-FRM/WG PK= Frame and Wireguard for HB<br />

2HB-FRM/WG PK= Frame and Wireguard for 2HB<br />

HB-FRM/LENS/WG PK= Frame and Prismatic Acrylic Lens with Wireguard for HB<br />

2HB-FRM/CL/WG PK= Frame and Clear Lens with Wireguard for 2HB<br />

HB/2HB HEAVY DUTY WIREGUARD DESIGNATION DESCRIPTION<br />

HEAVY DUTY STOCK WIREGUARD<br />

SWG/2HB-4FT-B= Heavy Duty Wireguard for field<br />

installation, 2HB only<br />

SWG/HB-4FT-B= Heavy Duty Wireguard for field<br />

installation, HB only<br />

A wide choice of acrylic<br />

lenses in a steel door frame<br />

(G1 & G2 optional)<br />

HB-FRM/DROPWG PK= Frame and Drop Wireguard for HB<br />

2HB-FRM/CL/DROPWG PK= Drop Wireguard, Clear Acrylic Lens and Door Frame for 2HB<br />

2HB-FRM/LENS/DROPWG PK= Drop Wireguard, Prismatic Acrylic Lens and Door Frame for 2HB<br />

2HB-FRM/DROPWG PK= Drop Wireguard and Door Frame for 2HB<br />

Finished in white<br />

42


Cooper Lighting<br />

Customer First Center<br />

1121 Highway 74 South<br />

Peachtree City, GA 30269<br />

P: 770-486-4800<br />

F: 770-486-4801<br />

www.cooperlighting.com<br />

Domestic Facilities<br />

Cranbury, New Jersey<br />

Elk Grove Village, Illinois<br />

Irving, Texas<br />

Ontario, California<br />

Peachtree City, Georgia<br />

Cooper Lighting, Metalux and Fail-Safe are valuable trademarks of Cooper Industries in the United States and other countries.<br />

You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.<br />

Cooper Industries, Ltd.<br />

600 Travis, Ste. 5800<br />

Houston, TX 77002-1001<br />

P: 713-209-8400<br />

www.cooperindustries.com<br />

ACF080768<br />

International Sales, USA<br />

Cooper Lighting<br />

1121 Highway 74 South<br />

Peachtree City, GA 30269<br />

P: 770-486-4800<br />

F: 770-486-4801<br />

Canada<br />

Cooper Lighting<br />

5925 McLaughlin Road<br />

Mississauga, Ontario L5R 1B8<br />

P: 905-507-4000<br />

F: 905-568-7049<br />

Canadian Facility<br />

Calgary, Alberta T2E 7V9<br />

Printed in USA<br />

The Cooper Lighting Family<br />

Halo<br />

Metalux<br />

Lumark<br />

Sure-Lites<br />

Neo-Ray<br />

Corelite<br />

Portfolio<br />

Iris<br />

Shaper<br />

io<br />

Lumière<br />

Invue<br />

McGraw-Edison<br />

Streetworks<br />

Fail-Safe<br />

MWS<br />

DLS<br />

RSA<br />

Ametrix