01.02.2013 Views

Lenze three-phase AC motors - MEYLE - Meyer Industrie Electronic ...

Lenze three-phase AC motors - MEYLE - Meyer Industrie Electronic ...

Lenze three-phase AC motors - MEYLE - Meyer Industrie Electronic ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical data, <strong>motors</strong><br />

Rated data for operation at 50 Hz<br />

<strong>Lenze</strong> <strong>three</strong>-<strong>phase</strong> <strong>AC</strong> <strong>motors</strong> are designed for operation on<br />

230/400 V <strong>three</strong>-<strong>phase</strong> mains and with <strong>Lenze</strong> 8200, 8210,<br />

9300 vector control and motec inverters.<br />

Rated data for operation at 50 Hz<br />

Type of protection: IP54, insulation class F<br />

Motor type Shaft Speed Torque Power Current Supply Fre- Power- Effici- Stalling Starting Starting Moment Weight<br />

height voltage quency factor ency torque torque current of<br />

inertia<br />

h<br />

[mm]<br />

nr [rpm]<br />

Mr [Nm]<br />

Pr [kW]<br />

I<br />

[A]<br />

U<br />

[V] [Hz] cos � �<br />

MK [Nm]<br />

MA [Nm]<br />

IA/Ir J<br />

[kgm<br />

m<br />

2] [kg]<br />

MDòMAòò 071-12 71 1370 1.8 0.25 1.1/1.8 400/230 50 0.60 0.62 3.4 3.4 3.8 0.0006 5.9<br />

MDòMAòò 071-32 71 1310 2.7 0.37 1.15/2.0 400/230 50 0.74 0.63 5.2 5.2 3.7 0.0008 6.6<br />

MDòMAòò 080-12 80 1370 3.9 0.55 1.6/2.8 400/230 50 0.78 0.65 6.8 6.5 3.8 0.0016 8.6<br />

MDòMAòò 080-32 80 1390 5.2 0.75 1.9/3.3 400/230 50 0.80 0.71 9.7 9.2 4.5 0.0019 9.88<br />

MDòMAòò 090-12 90 1405 7.5 1.1 2.6/4.5 400/230 50 0.80 0.77 21.0 16.5 4.9 0.0026 14.0<br />

MDòMAòò 090-32 90 1410 10.2 1.5 3.5/6.1 400/230 50 0.78 0.79 28.6 25.5 5.3 0.0034 17.2<br />

MDòMAòò 100-12 100 1425 14.7 2.2 4.8/8.3 400/230 50 0.80 0.82 37.8 35.0 6.1 0.0057 25.0<br />

MDòMAòò 100-32 100 1415 20.2 3.0 6.5/11.4 400/230 50 0.81 0.82 48.5 46.5 6.1 0.0065 26.0<br />

MDòMAòò 112-22 112 1435 26.6 4.0 8.3/14.3 400/230 50 0.82 0.85 73.4 66.5 6.3 0.0118 34.0<br />

MDòMAòò 132-12 132 1450 36.2 5.5 11.0/19.1 400/230 50 0.84 0.86 103.0 72.5 6.9 0.0290 62.0<br />

MDòMAòò 132-22 132 1450 49.4 7.5 14.6/25.4 400/230 50 0.85 0.87 140.0 107.0 6.7 0.0350 73.0<br />

MDòMAòò 160-22 160 1460 71.9 11.0 21.0/36.5 400/230 50 0.85 0.89 204.0 150.0 7.0 0.0610 110.0<br />

MDòMAòò 160-32 160 1460 98.1 15.0 27.8/48.4 400/230 50 0.87 0.90 288.0 214.0 7.1 0.0750 130.0<br />

MDòMAòò 180-12 180 1470 120.2 18.5 32.8/57.8 400/230 50 0.90 0.905 313.0 260.0 6.8 0.1350 165.0<br />

MDòMAòò 180-22 180 1456 144.3 22.0 38.8/67.4 400/230 50 0.90 0.91 360.0 330.0 7.3 0.1550 175.0<br />

* The <strong>motors</strong> can be operated at their rated torque in the voltage range between<br />

360 and 440 V without thermally overloading the motor.<br />

How operating frequency affects rated data<br />

Please refer to the table for the rated data for operation at<br />

50 Hz.<br />

In the power range from 3 ... 7.5 kW, on self-ventilated<br />

<strong>motors</strong>, please note the current derating of the<br />

8200 motec.<br />

The <strong>motors</strong> can be operated on 60 Hz mains. The table<br />

below shows how the rated data is affected by the operating<br />

frequency.<br />

Frequency Voltage Power Speed Torque Motor starting torque<br />

f in Hz<br />

U<br />

in %<br />

P<br />

in %<br />

n<br />

in %<br />

M<br />

in %<br />

MAin %<br />

Un Pn nn Mn MAN 50 100 100 100 100 100<br />

60 100 100 120 83 70<br />

60 120 120 120 100 100<br />

22 Three-<strong>phase</strong> <strong>AC</strong> <strong>motors</strong> en 1/2006