Operation at 87 Hz<br />

Setting the V/f break point to 87 Hz and 400 V in a<br />

Δ-connection for inverter operation enables the motor to<br />

be operated at up to 87 Hz with its rated torque without<br />

exceeding the thermal limit values of the motor.<br />

In comparison with operation at 50 Hz, this type of operation<br />

enables the permanent power of the motor to be<br />

increased by approximately 73%.<br />

However, throughout the range, the motor runs with the<br />

delta current increased by a factor of 400/230 = √3. Do not<br />

forget to dimension the inverter for the corresponding current.<br />

Torque reduction based on motor frame size<br />

with self-ventilation<br />

A motor protection relay is no longer sufficient to protect<br />

the motor as at operation at f