FBR-remote room control unit<br />

part no<br />

FBR<br />

FBR-room control<br />

- +<br />

3<br />

0<br />

0<br />

2<br />

1<br />

- +<br />

3<br />

0<br />

2<br />

1<br />

- +<br />

3<br />

0<br />

2<br />

1<br />

- +<br />

LÜFTUNG<br />

AKTIV<br />

LÜFTUNG<br />

EIN/AUS<br />

FBR-DS-PO<br />

Programming<br />

Title: SLS-500-FBR<br />

digital switch potentiometer button LED Gehäusetypen<br />

left green LED right red housing type<br />

X01.00<br />

3:08 HIGH QUALITY ELECTRONICS<br />

L+<br />

L+<br />

L+<br />

L+<br />

FBR<br />

Out<br />

FBR-DS-PO-S<br />

FBR<br />

Out<br />

FBR<br />

Out<br />

FBR<br />

* At request are also other Labeling and assembly variants available<br />

-<br />

Out<br />

Switch<br />

FBR-DS-PO-S-LG<br />

Switch<br />

Switch<br />

LED green<br />

FBR-DS-PO-S-LG-LR<br />

LED green<br />

Led red<br />

overview<br />

digital remote room control unit<br />

supply voltage 24V=<br />

two-wire connection<br />

room temperature measuring,<br />

party-switch and ideal value adjustment<br />

with button and 2 LEDs available<br />

various printing options are possible<br />

2-piece housing for easy installation<br />

mountable on a standard flush box<br />

specification<br />

supply voltage<br />

24Vdc + -10%<br />

duty cycle<br />

100%<br />

temperature range -5 to +40°C<br />

weight<br />

dimensions<br />

80g<br />

width<br />

85mm<br />

height<br />

85mm<br />

depth<br />

25mm<br />

operating conditions -20 bis +40°C non condensing<br />

R1.DAY1<br />

Day<br />

R1.AUTO1<br />

Auto<br />

R1.TEMP1<br />

Temp<br />

R1.NIGHT1<br />

Night<br />

R1.CORR1<br />

Corr<br />

R1.OPEN1<br />

Open<br />

FBR_DAY<br />

FBR_Auto<br />

FBR_Temp<br />

FBR_Night<br />

FBR_Corr<br />

FBR_Open<br />

Digital switch of the FBR<br />

Temperatue of the FBR<br />

Potentiometer of the FBR<br />

Bestellinformationen<br />

ordering information<br />

- - -<br />

- special<br />

FBR-DS-PO-S FBR-DS<br />

1<br />

1-<br />

1-<br />

-<br />

- special<br />

FBR-PO<br />

-<br />

1 - -<br />

- special<br />

FBR-DS-PO<br />

1<br />

1<br />

-<br />

-<br />

-<br />

special<br />

FBR-DS-PO-S<br />

1 1 1 -<br />

-<br />

special<br />

FBR-DS-PO-S-LG 1<br />

1 1 1<br />

- special<br />

FBR-DS-PO-S-LG-LR 1<br />

1 1 1<br />

1 special<br />