VCB 400 - Bonfiglioli USA
VCB 400 - Bonfiglioli USA
VCB 400 - Bonfiglioli USA
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
Digital Inverter<br />
<strong>VCB</strong> <strong>400</strong>
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
<strong>VCB</strong> <strong>400</strong> Inverter<br />
Convenient in operation and flexible in application<br />
Smooth acceleration With torque control<br />
Excellent revolving At high and very low speeds<br />
Pretentious positioning Even with full load torque at zero speed<br />
Highly accurate<br />
synchronous operation For multi-motor drives and electronic gears<br />
Highdynamic current<br />
and torque limiting For proper operation under fast load shocks<br />
Sweep function With periodical speed reference profiles<br />
With the <strong>VCB</strong> range, BONFIGLIOLI VECTRON introduces a<br />
powerful generation of frequency inverters.<br />
Their all-in-one features are bound to provide the right solution<br />
for your drive requirements - from simple speed variation<br />
applications up to high dynamic servo applications.<br />
You will find the right specialist partner in BONFIGLIOLI<br />
VECTRON who gained a wealth of experience accumulated<br />
from several 100,000 installed frequency inverters.<br />
Drives with BONFIGLIOLI VECTRON frequency inverters offer<br />
solutions of rational use of energy and materials in smallest<br />
possible physical size - it is a way to bionic drives.
Frequency inverters of the <strong>VCB</strong> range operate at input voltages from 230 to 500 Vrms<br />
Means free choice of the most suitable control method for specific applications<br />
up to positioning and synchronous drives - using the key pad or any other control unit<br />
For space and cost saving installation.<br />
All drives may be connected to a common DC bus in order to interchange energy<br />
Is a commissioning and parameterising software, which is available as an accessory and<br />
can be used with the 32 bit windows operating systems on your notebook or personal<br />
computer. It allows the convenient setting of the frequency inverter to its drive task<br />
Are available for all control inputs and outputs for quick connection and disconnection<br />
To prevent unintentional starting during work on the system,<br />
e.g. during inspection and servicing<br />
Throughout the whole power range<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
Inverter <strong>VCB</strong> <strong>400</strong> 1<br />
Can be done using<br />
- RS 232<br />
- RS 485<br />
- CAN open<br />
- Profibus-DP<br />
- LON<br />
Is a light, handy unit with 4 key operation and with a 140 segment display for alphanumeric<br />
characters and symbols. The KP 100 is used for setting up the frequency inverter<br />
to the required drive tasks and for displaying the drive parameters<br />
Separate cooling for control electronic and power electronic can be realized<br />
Wide voltage range<br />
Different control methods<br />
made to measure<br />
Butt mounting size<br />
PC software VPlus<br />
Plug-in terminals<br />
Safety relay as per EN 60204<br />
Standardized interfaces<br />
Digital communication<br />
Keypad KP 100<br />
Mounting and installation
2<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
<strong>VCB</strong> <strong>400</strong> Inverter<br />
Integrated brake chopper For limitation of the DC link voltage during regenerative operation<br />
Inputs and outputs<br />
Extensions and accessories<br />
The <strong>VCB</strong> range of frequency inverters offers the following control connections for all<br />
power classes. They all have a safe isolation and are accessible in the sense of EN.<br />
All outputs are also individually isolated<br />
1 +10V reference supply<br />
2 analog 0 V (GND)<br />
3 analog input 1<br />
4 analog input 1<br />
(GND, reference)<br />
5 analog input 2<br />
6 analog input 2, 3<br />
(GND, reference)<br />
7 analog input 3<br />
8 analog output<br />
1 NO contact<br />
2 centre point relay<br />
3 NC contact<br />
1 +24 V supply output<br />
2 digital 0 V (GND)<br />
3 digital input 1<br />
4 digital input 2<br />
5 digital input 3<br />
6 digital input 4<br />
7 digital input 5<br />
8 digital input 6<br />
9 digital input 7<br />
10 digital input 8<br />
11 external supply 30 V<br />
12 digital output 1<br />
13 digital output 2<br />
14 external supply 0 V (GND)<br />
15 15 external supply +8 V<br />
VECTRON offers a wide choice of additional facilities for controlling, communication<br />
and special control connections as well as accessories to suit your specific requirements
Depending on the requirements you have to incorporate various features in your drives.<br />
The <strong>VCB</strong> range of frequency inverters offers you a selection of basic functions which can<br />
be activated time and/or event related.<br />
Give you push-button control for a variety of pre-configurated function sequences<br />
for lifting drives, winding drives, pressure control etc.<br />
For range adjustment to peripheral control elements<br />
Can be implemented on request.<br />
Consequently, elimination of peripheral components is possible<br />
The properties of the <strong>VCB</strong> range can be flexibly adapted to any given drive task thanks<br />
to their freely programmable functions<br />
If the operating modes change<br />
Enables your drive also for high starting torque<br />
Enables starting at any operation point<br />
If you need very fast shut-down without mains unit or brake unit, you can use the<br />
voltage control and the motor chopper<br />
If you wish to set the speed through a contact input<br />
If you like to carry out for example pressure, volume flow or speed regulation with the<br />
integrated PI controller<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
Inverter <strong>VCB</strong> <strong>400</strong> 3<br />
Basic functions<br />
Application functions<br />
Adaptation for analogue<br />
inputs and outputs<br />
Customer’s own functions<br />
Unlimited interlinking<br />
of function blocks<br />
Four different data sets<br />
Torque boost<br />
Synchronisation<br />
to a rotating motor<br />
Controlled braking<br />
Motor potentiometer function<br />
Technology controller
4<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
<strong>VCB</strong> <strong>400</strong> Inverter<br />
Programmable starting<br />
and stopping behaviour<br />
Status display<br />
of the digital inputs and outputs<br />
So that the drive can be safely started and stopped and can also be controlled at a<br />
standstill according to the application<br />
S ramp profile If your drive has to make a smooth transition from one speed to another<br />
Power failure regulation<br />
Can be activated using kinetic energies to maintain operation during short blackouts<br />
of the mains<br />
Parameter identification If you wish to start your drive with menu guidance<br />
Intelligent current limits<br />
Allowing the drive to automatically and safely adjust to dynamic load changes and<br />
different ambient conditions using its power reserves<br />
Brake control If you want to activate your stop brake at an exact time and without wear<br />
Actual value memory<br />
Storing last 16 trips<br />
Warning messages<br />
Free choice<br />
of the reference value source<br />
Motor circuit breaker<br />
Keeps you constantly informed and allows you to monitor various actual values for the<br />
application<br />
Gives information on irregularities in operation; the last four trips show the accurate<br />
operating point of the drive<br />
Which are signalled by the frequency inverter via digital output as soon as a configurable<br />
limit has been reached<br />
Via the frequency reference value channel or percentage reference value channel for<br />
each data set. Here several sources can be connected additively<br />
For individual and multiple motor operation to protect the motor and its leads from<br />
overheating so that protection is possible in case of a short circuit or overloading<br />
So that the present state of the digital inputs and outputs can be controlled during the<br />
commissioning phase
Output motor side<br />
Input<br />
mains side<br />
General<br />
Environment<br />
Options &<br />
Acces-sories<br />
<strong>VCB</strong> <strong>400</strong> / 22-65 kW<br />
overload 1.5<br />
Rated motor output rec. P kW<br />
Nominal power S kVA<br />
Nominal current I A<br />
Voltage<br />
U V<br />
Overload capacity - -<br />
Frequency<br />
f Hz<br />
Voltage<br />
U V<br />
Frequency<br />
f Hz<br />
Power factor cosϕ -<br />
Short circuit/<br />
earth fault<br />
- -<br />
Efficiency (approx.) η %<br />
Switching frequency f kHZ<br />
Protection<br />
- -<br />
Dimensions WxHxD mm<br />
Weight (approx.) m kg<br />
Coolant temperature Tn °C<br />
Rel. Humidity<br />
- %<br />
Power reduction P %<br />
Line choke (uk=4%) - -<br />
EMC filter<br />
- -<br />
Brake unit<br />
- -<br />
<strong>VCB</strong> <strong>400</strong><br />
045<br />
OL 1.5<br />
22<br />
31,2<br />
45<br />
We reserve the right to introduce changes without notice<br />
Expansions<br />
<strong>VCB</strong> <strong>400</strong><br />
060<br />
OL 1.5<br />
30<br />
41,6<br />
60<br />
Inverter <strong>VCB</strong> <strong>400</strong> 5<br />
<strong>VCB</strong> <strong>400</strong><br />
075<br />
OL 1.5<br />
KP100 Control unit<br />
VPlus PC software for 32 bit windows operating systems<br />
ADA-<strong>VCB</strong>-2 RS232 / KP100 interface converter set<br />
VCM-PTC Motor PTC monitoring<br />
ENC-1 Speed feedback and motor PTC monitoring<br />
EAL-1 Expansion for analog outputs, leading frequency and motor PTC monitoring<br />
VCI-232 RS232 - connection<br />
VCI-485 RS485 - connection<br />
VCI-CAN CANopen - connection<br />
VCI-PROF Profibus-DP - connection<br />
VCI-LON LON - connection<br />
<strong>VCB</strong> <strong>400</strong><br />
090<br />
OL 1.5<br />
37<br />
45<br />
52,0 62,4<br />
75<br />
90<br />
3 x 0 ... mains voltage input<br />
1,5 for 60 s<br />
0 ... <strong>400</strong>, according to switching frequency<br />
3 x <strong>400</strong> (-20%) ... 460 (+10%)<br />
50 (-10%) ... 60 (+10%)<br />
~1 (Power factor of the fundamental)<br />
yes, unlimited<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
<strong>VCB</strong> <strong>400</strong><br />
115<br />
OL 1.5<br />
55<br />
79,7<br />
115<br />
Technical data<br />
<strong>VCB</strong> <strong>400</strong><br />
135<br />
OL 1.5<br />
65<br />
93,5<br />
135<br />
98 , at 2 kHz switching frequency<br />
1 ... 8<br />
IP20, VBG4<br />
1 ... 4<br />
250 x 376 x 317<br />
300 x 602 x 298<br />
17 18 19 31,5 32,5<br />
0 ... 40 , forced ventilation<br />
15 ... 85 , no condensation<br />
2,5%/K above Tn, Tmax=50°C; 5%/1000 m above 1000 m above sea level; hmax=<strong>400</strong>0 m<br />
external<br />
external<br />
internal brake transistor, external
6<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
<strong>VCB</strong> <strong>400</strong> Inverter<br />
Output motor side<br />
Input<br />
mains side<br />
General<br />
Environment<br />
Options &<br />
Acces-sories<br />
Rated motor output rec. P<br />
Nominal power S<br />
Nominal current I<br />
Voltage<br />
U<br />
Overload capacity -<br />
Frequency<br />
f<br />
Voltage<br />
U<br />
Frequency<br />
f<br />
Power factor cosϕ<br />
Short circuit/<br />
earth fault<br />
-<br />
Efficiency (approx.) η<br />
Switching frequency f<br />
Protection<br />
-<br />
Dimensions WxHxD<br />
Weight (approx.) m<br />
Coolant temperature Tn<br />
Rel. Humidity<br />
-<br />
Power reduction P<br />
Line choke (uk=4%) -<br />
EMC filter<br />
-<br />
Brake unit<br />
-<br />
kW<br />
kVA<br />
A<br />
V<br />
Hz<br />
V<br />
Hz<br />
-<br />
-<br />
%<br />
kHZ<br />
-<br />
mm<br />
kg<br />
°C<br />
%<br />
%<br />
-<br />
-<br />
-<br />
<strong>VCB</strong> <strong>400</strong><br />
150<br />
OL 1.5<br />
75<br />
103,9<br />
150<br />
We reserve the right to introduce changes without notice<br />
EU guidelines<br />
<strong>VCB</strong> <strong>400</strong> / 75-250 kW<br />
overload 1.5<br />
<strong>VCB</strong> <strong>400</strong><br />
180<br />
OL 1.5<br />
90<br />
124,7<br />
180<br />
<strong>VCB</strong> <strong>400</strong><br />
210<br />
OL 1.5<br />
<strong>VCB</strong> <strong>400</strong><br />
250<br />
OL 1.5<br />
<strong>VCB</strong> <strong>400</strong><br />
300<br />
OL 1.5<br />
110 132 160<br />
145,5 173,2 207,8<br />
210 250 300<br />
3 x 0 ... mains voltage input<br />
1,5 for 60 s<br />
0 ... <strong>400</strong>, according to switching frequency<br />
3 x <strong>400</strong> (-20%) ... 460 (+10%)<br />
50 (-10%) ... 60 (+10%)<br />
~1 (Power factor of the fundamental)<br />
yes, unlimited<br />
<strong>VCB</strong> <strong>400</strong><br />
370<br />
OL 1.5<br />
200<br />
256,3<br />
370<br />
<strong>VCB</strong> <strong>400</strong><br />
460<br />
OL 1.5<br />
250<br />
318,7<br />
460<br />
98 , at 2 kHz switching frequency<br />
1 ... 8 1 ... 4<br />
IP20, VBG4<br />
412 x 510 x 362<br />
518 x 820 x 406<br />
50<br />
110<br />
0 ... 40 , forced ventilation<br />
15 ... 85 , no condensation<br />
2,5%/K above Tn, Tmax=50°C; 5%/1000 m above 1000 m above sea level; hmax=<strong>400</strong>0 m<br />
external<br />
external<br />
internal brake transistor, external<br />
All units from the <strong>VCB</strong> range are designed and built in accordance with the requirements<br />
of the 73/23/EEC guidelines (CE conformity). The EMC 89/336/EEC requirements are<br />
also fulfilled subject to correct installation.<br />
The required manufacturer’s and conformity declarations are included in the documentation<br />
supplied with the equipment.<br />
The frequency inverters VBC <strong>400</strong>-010 up to <strong>VCB</strong> <strong>400</strong>-135 are released as per UL in compliane<br />
with UL 508c and are in compliance with the CSA stndards C22.2 - No. 14-95.<br />
The release of the frequency inverters <strong>VCB</strong> <strong>400</strong>-150 to <strong>VCB</strong> <strong>400</strong>-610 complying with UL<br />
and CSA Rules are under development.
Output motor side<br />
Input<br />
mains side<br />
General<br />
Environment<br />
Options &<br />
Acces-sories<br />
<strong>VCB</strong> <strong>400</strong> / 22-65 kW<br />
overload 1.2<br />
Rated motor output rec. P kW<br />
Nominal power S kVA<br />
Nominal current I A<br />
Voltage<br />
U V<br />
Overload capacity -<br />
Frequency<br />
f Hz<br />
Voltage<br />
U V<br />
Frequency<br />
f Hz<br />
Power factor cosϕ -<br />
Short circuit/<br />
earth fault<br />
- -<br />
Efficiency (approx.) η %<br />
Switching frequency f kHZ<br />
Protection<br />
- -<br />
Dimensions WxHxD mm<br />
Weight (approx.) m kg<br />
Coolant temperature Tn °C<br />
Rel. Humidity<br />
- %<br />
Power reduction P %<br />
Line choke (uk=4%) - -<br />
EMC filter<br />
- -<br />
Brake unit<br />
- -<br />
<strong>VCB</strong> <strong>400</strong><br />
045<br />
OL 1.2<br />
22<br />
31,2<br />
45<br />
We reserve the right to introduce changes without notice<br />
Expansions<br />
<strong>VCB</strong> <strong>400</strong><br />
060<br />
OL 1.2<br />
30<br />
41,6<br />
60<br />
Inverter <strong>VCB</strong> <strong>400</strong> 7<br />
<strong>VCB</strong> <strong>400</strong><br />
075<br />
OL 1.2<br />
KP100 Control unit<br />
VPlus PC software for 32 bit windows operating systems<br />
ADA-<strong>VCB</strong>-2 RS232 / KP100 interface converter set<br />
VCM-PTC Motor PTC monitoring<br />
ENC-1 Speed feedback and motor PTC monitoring<br />
EAL-1 Expansion for analog outputs, leading frequency and motor PTC monitoring<br />
VCI-232 RS232 - connection<br />
VCI-485 RS485 - connection<br />
VCI-CAN CANopen - connection<br />
VCI-PROF Profibus-DP - connection<br />
VCI-LON LON - connection<br />
<strong>VCB</strong> <strong>400</strong><br />
090<br />
OL 1.2<br />
37<br />
45<br />
52,0 62,4<br />
75<br />
90<br />
3 x 0 ... mains voltage input<br />
1,5 for 60 s<br />
0 ... <strong>400</strong>, according to switching frequency<br />
3 x <strong>400</strong> (-20%) ... 460 (+10%)<br />
50 (-10%) ... 60 (+10%)<br />
~1 (Power factor of the fundamental)<br />
yes, unlimited<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
<strong>VCB</strong> <strong>400</strong><br />
115<br />
OL 1.2<br />
55<br />
79,7<br />
115<br />
Technical data<br />
<strong>VCB</strong> <strong>400</strong><br />
135<br />
OL 1.2<br />
65<br />
93,5<br />
135<br />
98 , at 2 kHz switching frequency<br />
1 ... 8<br />
IP20, VBG4<br />
1 ... 4<br />
250 x 376 x 317<br />
300 x 602 x 298<br />
17 18 19 31,5 32,5<br />
0 ... 40 , forced ventilation<br />
15 ... 85 , no condensation<br />
2,5%/K above Tn, Tmax=50°C; 5%/1000 m above 1000 m above sea level; hmax=<strong>400</strong>0 m<br />
external<br />
external<br />
internal brake transistor, external
8<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
<strong>VCB</strong> <strong>400</strong> Inverter<br />
Output motor side<br />
Input<br />
mains side<br />
General<br />
Environment<br />
Options &<br />
Acces-sories<br />
<strong>VCB</strong> <strong>400</strong> / 75-355 kW<br />
overload 1.2<br />
Rated motor output rec. P<br />
Nominal power S<br />
Nominal current I<br />
Voltage<br />
U<br />
Overload capacity -<br />
Frequency<br />
f<br />
Voltage<br />
U<br />
Frequency<br />
f<br />
Power factor cosϕ<br />
Short circuit/<br />
earth fault<br />
-<br />
Efficiency (approx.) η<br />
Switching frequency f<br />
Protection<br />
-<br />
Dimensions WxHxD<br />
Weight (approx.) m<br />
Coolant temperature Tn<br />
Rel. Humidity<br />
-<br />
Power reduction P<br />
Line choke (uk=4%) -<br />
EMC filter<br />
-<br />
Brake unit<br />
-<br />
kW<br />
kVA<br />
A<br />
V<br />
Hz<br />
V<br />
Hz<br />
-<br />
-<br />
%<br />
kHZ<br />
-<br />
mm<br />
kg<br />
°C<br />
%<br />
%<br />
-<br />
-<br />
-<br />
<strong>VCB</strong> <strong>400</strong><br />
150<br />
OL 1.2<br />
75<br />
103,9<br />
150<br />
We reserve the right to introduce changes without notice<br />
EU guidelines<br />
<strong>VCB</strong> <strong>400</strong><br />
180<br />
OL 1.2<br />
90<br />
124,7<br />
180<br />
<strong>VCB</strong> <strong>400</strong><br />
210<br />
OL 1.2<br />
<strong>VCB</strong> <strong>400</strong><br />
250<br />
OL 1.2<br />
<strong>VCB</strong> <strong>400</strong><br />
300<br />
OL 1.2<br />
<strong>VCB</strong> <strong>400</strong><br />
370<br />
OL 1.2<br />
<strong>VCB</strong> <strong>400</strong><br />
460<br />
OL 1.2<br />
110 132 160 200 250<br />
145,5 173,2 207,8 256,3 318,7<br />
210 250 300 370 460<br />
3 x 0 ... mains voltage input<br />
1,5 for 60 s<br />
0 ... <strong>400</strong>, according to switching frequency<br />
3 x <strong>400</strong> (-20%) ... 460 (+10%)<br />
50 (-10%) ... 60 (+10%)<br />
~1 (Power factor of the fundamental)<br />
yes, unlimited<br />
<strong>VCB</strong> <strong>400</strong><br />
570<br />
OL 1.2<br />
315<br />
395<br />
570<br />
<strong>VCB</strong> <strong>400</strong><br />
610<br />
OL 1.2<br />
355<br />
422,6<br />
610<br />
1 ... 8<br />
98 , at 2 kHz switching frequency<br />
1 ... 4<br />
IP20, VBG4<br />
412 x 510 x 362<br />
518 x 820 x 406 518 x 1095 x 406<br />
50<br />
110<br />
0 ... 40 , forced ventilation<br />
15 ... 85 , no condensation<br />
120<br />
2,5%/K above Tn, Tmax=50°C; 5%/1000 m above 1000 m above sea level; hmax=<strong>400</strong>0 m<br />
external<br />
external<br />
internal brake transistor, external<br />
external<br />
All units from the <strong>VCB</strong> range are designed and built in accordance with the requirements<br />
of the 73/23/EEC guidelines (CE conformity). The EMC 89/336/EEC requirements are<br />
also fulfilled subject to correct installation.<br />
The required manufacturer’s and conformity declarations are included in the documentation<br />
supplied with the equipment.<br />
The frequency inverters VBC <strong>400</strong>-010 up to <strong>VCB</strong> <strong>400</strong>-135 are released as per UL in compliane<br />
with UL 508c and are in compliance with the CSA stndards C22.2 - No. 14-95.<br />
The release of the frequency inverters <strong>VCB</strong> <strong>400</strong>-150 to <strong>VCB</strong> <strong>400</strong>-610 complying with UL<br />
and CSA Rules are under development.
Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Field 7<br />
Inverter<br />
series<br />
Size<br />
Overload<br />
OL<br />
<strong>VCB</strong> <strong>400</strong><br />
045<br />
060<br />
075<br />
090<br />
115<br />
135<br />
150<br />
180<br />
210<br />
250<br />
300<br />
370<br />
460<br />
570<br />
610<br />
OL1.5<br />
OL1.2<br />
Standard values are shown in bold<br />
Designation rules<br />
- The BU option is only available with overload OL1.5<br />
- Sizes 570 and 610 are only available with overload OL1.2<br />
- Communication modules (Field 6) are alternatives<br />
- Expansion modules (Field 7) are alternatives<br />
Field 1: <strong>VCB</strong><strong>400</strong> = inverter <strong>VCB</strong> 3ph <strong>400</strong>VAC<br />
Field 2: 045 = 22 kW<br />
060 = 30 kW<br />
075 = 37 kW<br />
090 = 45 kW<br />
115 = 55 kW<br />
135 = 65 kW<br />
150 = 75 kW<br />
180 = 90 kW<br />
210 = 110 kW<br />
250 = 132 kW<br />
300 = 160 kW<br />
370 = 200 kW<br />
460 = 250 kW<br />
570 = 315 kW<br />
610 = 355 kW<br />
Braking<br />
unit<br />
_no BU<br />
BU<br />
Example of designation: <strong>VCB</strong><strong>400</strong> 060 OL1.5 BU KP100 VCI232<br />
Inverter <strong>VCB</strong> <strong>400</strong> 9<br />
KP<br />
keypad<br />
KP100<br />
_no KP<br />
Communication<br />
modules<br />
VCI 232<br />
_no communic.<br />
VCI485<br />
VCICAN<br />
VCIPROF<br />
VCILON<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
<strong>VCB</strong> designation<br />
Expansion<br />
modules<br />
_no exp<br />
EAL1<br />
ENC1<br />
VCMPTC<br />
Specialist<br />
applications<br />
Field 3: OL1.2 = overload 120%<br />
OL1.5 = overload 150%<br />
Field 4: _ (blank) = no braking unit<br />
BU = internal braking unit<br />
Field 5: _ (blank) = no keypad<br />
KP100 = keypad<br />
Field 6: _ (blank) = no communication module<br />
VCI232 = RS232 serial interface<br />
VCI485 = RS485 serial interface<br />
VCICAN = CAN BUS interface<br />
VCIPROF = PROFIBUS interface<br />
VCILON = LON interface<br />
Field 7: _ (blank) = no expansion module<br />
EAL1 = analog expansion module<br />
ENC1 = encoder module<br />
VCMPTC = temperature control module with PTC thermistor
10<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
<strong>VCB</strong> <strong>400</strong> Inverter<br />
3x<strong>400</strong>V line inductor for <strong>VCB</strong> <strong>400</strong> inverters<br />
Size<br />
Description<br />
of inductor<br />
Rated<br />
current (A)<br />
Inductance<br />
(mH)<br />
Dissipated<br />
power (W)<br />
Dimensions (mm) Installation (mm)<br />
a b c n2 n1 d<br />
045<br />
LCVT050<br />
50<br />
0.59<br />
100 155 115 190 130<br />
060<br />
LCVT060<br />
60<br />
0.49<br />
100 190 110 220 170<br />
075<br />
LCVT075<br />
75<br />
0.37<br />
110 190 120 250 170<br />
090<br />
LCVT090<br />
90<br />
0.33<br />
120 190 130 250 170<br />
115<br />
LCVT115<br />
115 0.25<br />
140 210 140 270 180<br />
135<br />
LCVT135<br />
135 0.22<br />
180 240 160 300 190<br />
150<br />
LCVT160<br />
160 0.18<br />
180 240 160 310 190<br />
180<br />
LCVT180<br />
180 0.16<br />
185 240 175 320 190<br />
210<br />
LCVT210<br />
210 0.14<br />
200 240 200 335 190<br />
250<br />
LCVT250<br />
250 0.12<br />
210 240 210 350 190<br />
300<br />
LCVT300<br />
300 0.098 290 320 210 410 240<br />
370<br />
LCVT370<br />
370 0.077 350 320 230 410 240<br />
460<br />
LCVT460<br />
460 0.064 410 360 270 460 240<br />
570<br />
LCVT600<br />
610 0.049 480 360 290 510 310<br />
610 verify the application with <strong>Bonfiglioli</strong>’s technical service<br />
Always fit the inductor on the input<br />
LCVT050 ... LCVT370<br />
LCVT460 ... LCVT600<br />
72<br />
58<br />
68<br />
78<br />
82<br />
100<br />
100<br />
106<br />
121<br />
126<br />
121<br />
134<br />
146<br />
126<br />
8<br />
8<br />
8<br />
8<br />
8<br />
11<br />
11<br />
11<br />
11<br />
11<br />
11<br />
11<br />
11<br />
11<br />
Weight<br />
(kg)<br />
4,5<br />
9,0<br />
12<br />
12<br />
14<br />
20<br />
20<br />
22<br />
26<br />
28<br />
38<br />
46<br />
55<br />
65
Size<br />
045<br />
060<br />
075<br />
90<br />
115<br />
135/150<br />
180<br />
210<br />
250<br />
300<br />
370<br />
460<br />
570<br />
610<br />
Description<br />
of filter<br />
FTV050<br />
FTV063<br />
FTV080<br />
FTV100<br />
FTV125<br />
FTV150<br />
FTV180<br />
FTV210<br />
FTV250<br />
FTV300<br />
FTV<strong>400</strong><br />
FTV500<br />
FTV600<br />
FTV700<br />
Rated<br />
current (A)<br />
50<br />
63<br />
80<br />
100<br />
125<br />
150<br />
180<br />
220<br />
250<br />
300<br />
<strong>400</strong><br />
500<br />
600<br />
Overload<br />
(A)<br />
Dissipated<br />
power (W)<br />
FTV050 FTV063 ... FTV150<br />
FTV180 ... FTV<strong>400</strong><br />
Inverter <strong>VCB</strong> <strong>400</strong> 11<br />
75<br />
31 290 90 100<br />
94,5<br />
53 330 150 103<br />
120<br />
68 325 150 107<br />
150<br />
68 325 150 107<br />
187,5<br />
82 345 175 137<br />
225<br />
88 405 175 156<br />
270<br />
150 490 170 158<br />
330<br />
180 490 170 158<br />
375<br />
180 490 230 158<br />
<strong>400</strong><br />
200 490 230 158<br />
600<br />
230 580 230 158<br />
750<br />
270 630 345 158<br />
900<br />
290 660 375 187<br />
verify the application with <strong>Bonfiglioli</strong>’s technical service<br />
FTV500 ... FTV600<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
EMC filters for <strong>VCB</strong> <strong>400</strong> inverters<br />
Dimensions (mm) Installation (mm)<br />
H B T D E<br />
275<br />
315<br />
310<br />
310<br />
330<br />
390<br />
470<br />
470<br />
470<br />
470<br />
560<br />
530<br />
450<br />
50/76<br />
105<br />
105<br />
105<br />
120<br />
120<br />
110<br />
110<br />
170<br />
170<br />
170<br />
325<br />
355
12<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
Worldwide<br />
<strong>Bonfiglioli</strong> is a Partner Worldwide for Power Transmission and Motion Control<br />
The ever-growing export share has led <strong>Bonfiglioli</strong> into the most far away Countries.<br />
With expansion plans entailing a further growth of the sales network <strong>Bonfiglioli</strong> aims at improving<br />
both the competitiveness of its products and the effectiveness of the Customer service.<br />
In every market place <strong>Bonfiglioli</strong> is committed to improve the Customer satisfaction by offering<br />
state-of-the-art technology and shorter deliveries. Nowadays branch companies and BEST Partners<br />
bearing the <strong>Bonfiglioli</strong> name are operating in seventeen Countries outside Italy, with sales and<br />
service in the other countries managed by appointed dealers.<br />
The domestic network is made up of 30 sales office and representatives and 100 dealers operating<br />
with their own warehouse and supporting Customers locally. Throughout the World <strong>Bonfiglioli</strong>’s<br />
reputed know-how and Service guarantee effective and timely assistance.
AUSTRALIA<br />
BONFIGLIOLI TRANSMISSION (Aust) Pty Ltd.<br />
48-50 Adderley St. (East) Auburn (Sydney) N.S.W. 2144<br />
Tel. (+61) 2 8748 4<strong>400</strong> - Fax (+61) 2 9748 8740<br />
P.o. Box 6705 Silverwater NSW 1811<br />
www.bonfiglioli.com.au - bta1@bonfiglioli.com.au<br />
AUSTRIA<br />
MOLL MOTOR GmbH<br />
Industriestrasse 8 - 2000 Stockerau<br />
Tel. (+43) 2266 63421+DW - Fax (+43) 6342 180<br />
Tlx 61 32 22 348 Molla<br />
www.mollmotor.at - office@mollmotor.at<br />
BELGIUM<br />
N.V. ESCO TRANSMISSION S.A.<br />
Culliganlaan 3 - 1831 Machelem Diegem<br />
Tel. 0032 2 7204880 - Fax 0032 2 7212827<br />
Tlx 21930 Escopo B<br />
www.escotrans.be - info@escotrans.be<br />
BRASIL<br />
ATI BRASIL<br />
Rua Omlio Monteiro Soares, 260 - Vila Fanny - 81030-000<br />
Tel. (+41) 334 2091 - Fax (+41) 332 8669<br />
www.atibrasil.com.br - vendas@atibrasil.com.br<br />
CANADA<br />
BONFIGLIOLI CANADA INC.<br />
2-7941 Jane Street - Concord, ONTARIO L4K 4L6<br />
Tel. (+1) 905 7384466 - Fax (+1) 905 7389833<br />
www.bonfigliolicanada.com - sales@bonfigliolicanada.com<br />
CHINA<br />
BONFIGLIOLI DRIVES (SHANGHAI) CO. LTD.<br />
No. 8 Building, Area C1 - 318<br />
SuHong Road, Qingpu, Shanghai 201700<br />
Tel. +86 21 69225500 - Fax +86 21 69225511<br />
www.bonfiglioli.cn - linkn@bonfiglioli.com<br />
FRANCE<br />
BONFIGLIOLI TRANSMISSIONS S.A.<br />
14 Rue Eugène Pottier BP 19<br />
Zone Industrielle de Moimont II - 95670 Marly la Ville<br />
Tel. (+33) 1 34474510 - Fax (+33) 1 34688800<br />
www.bonfiglioli.fr - btf@bonfiglioli.fr<br />
GERMANY<br />
BONFIGLIOLI DEUTSCHLAND GmbH<br />
Hamburger Straße 18 - 41540 Dormagen<br />
Tel. (+49) 2133 50260 - Fax (+49) 2133 502610<br />
www.bonfiglioli.de - info@bonfiglioli.de<br />
GREAT BRITAIN<br />
BONFIGLIOLI UK Ltd<br />
Unit 3 Colemeadow Road - North Moons Moat<br />
Redditch. Worcestershire B98 9PB<br />
Tel. (+44) 1527 65022 - Fax (+44) 1527 61995<br />
www.bonfiglioli.co.uk - marwaha@bonfiglioli.com<br />
BONFIGLIOLI (UK) LIMITED<br />
5 Grosvenor Grange - Woolston - Warrington, Cheshire WA1 4SF<br />
Tel. (+44) 1925 852667 - Fax (+44) 1925 852668<br />
www.bonfiglioliuk.co.uk - sales@bonfiglioliuk.co.uk<br />
GREECE<br />
BONFIGLIOLI HELLAS S.A.<br />
O.T. 48A T.O. 230 - C.P. 570 22 Industrial Area - Thessaloniki<br />
Tel. (+30) 2310 796456 - Fax (+30) 2310 795903<br />
www.bonfiglioli.gr - info@bonfiglioli.gr<br />
HOLLAND<br />
ELSTO AANDRIJFTECHNIEK<br />
Loosterweg, 7 - 2215 TL Voorhout<br />
Tel. (+31) 252 219 123 - Fax (+31) 252 231 660<br />
www.elsto.nl - imfo@elsto.nl<br />
HUNGARY<br />
AGISYS AGITATORS & TRANSMISSIONS Ltd<br />
2045 Törökbálint, Tö u.2. Hungary<br />
Tel. +36 23 50 11 50 - Fax +36 23 50 11 59<br />
www.agisys.hu - info@agisys.com<br />
INDIA<br />
BONFIGLIOLI TRANSMISSIONS PVT Ltd.<br />
PLOT AC7-AC11 Sidco Industrial Estate<br />
Thirumudivakkam - Chennai 600 044<br />
Tel. +91(0)44 24781035 / 24781036 / 24781037<br />
Fax +91(0)44 24780091 / 24781904<br />
www.bonfiglioli.co.in - bonfig@vsnl.com<br />
NEW ZEALAND<br />
SAECO BEARINGS TRANSMISSION<br />
36 Hastie Avenue, Mangere<br />
Po Box 22256, Otahuhu - Auckland<br />
Tel. +64 9 634 7540 - Fax +64 9 634 7552<br />
mark@saeco.co.nz<br />
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
Worldwide<br />
<strong>Bonfiglioli</strong> Worldwide & BEST Partners<br />
POLAND<br />
POLPACK Sp. z o.o. - Ul. Chrobrego 135/137 - 87100 Torun<br />
Tel. 0048.56.6559235 - 6559236 - Fax 0048.56.6559238<br />
www.polpack.com.pl - polpack@polpack.com.pl<br />
RUSSIA<br />
FAM<br />
57, Maly prospekt, V.O. - 199048, St. Petersburg<br />
Tel. +7 812 3319333 - Fax +7 812 3271454<br />
www.fam-drive.ru - info@fam-drive.ru<br />
SPAIN<br />
TECNOTRANS SABRE S.A.<br />
Pol. Ind. Zona Franca sector C, calle F, n°6 08040 Barcelona<br />
Tel. (+34) 93 4478<strong>400</strong> - Fax (+34) 93 3360402<br />
www.tecnotrans.com - tecnotrans@tecnotrans.com<br />
SOUTH AFRICA<br />
BONFIGLIOLI POWER TRANSMISSION Pty Ltd.<br />
55 Galaxy Avenue, Linbro Business Park - Sandton<br />
Tel. (+27) 11 608 2030 OR - Fax (+27) 11 608 2631<br />
www.bonfiglioli.co.za - bonfigsales@bonfiglioli.co.za<br />
SWEDEN<br />
BONFIGLIOLI SKANDINAVIEN AB<br />
Kontorsgatan - 234 34 Lomma<br />
Tel. (+46) 40 412545 - Fax (+46) 40 414508<br />
www.bonfiglioli.se - info@bonfiglioli.se<br />
THAILAND<br />
K.P.T MACHINERY (1993) CO.LTD.<br />
259/83 Soi Phiboonves, Sukhumvit 71 Rd. Phrakanong-nur,<br />
Wattana, Bangkok 10110<br />
Tel. 0066.2.3913030/7111998<br />
Fax 0066.2.7112852/3811308/3814905<br />
www.kpt-group.com - sales@kpt-group.com<br />
<strong>USA</strong><br />
BONFIGLIOLI <strong>USA</strong> INC<br />
1000 Worldwide Boulevard - Hebron, KY 41048<br />
Tel.: (+1) 859 334 3333 - Fax: (+1) 859 334 8888<br />
www.bonfiglioliusa.com<br />
industrialsales@bonfiglioliusa.com<br />
mobilesales@bonfiglioliusa.com<br />
VENEZUELA<br />
MAQUINARIA Y ACCESSORIOS IND.-C.A.<br />
Calle 3B - Edif. Comindu - Planta Baja - Local B<br />
La Urbina - Caracas 1070<br />
Tel. 0058.212.2413570 / 2425268 / 2418263<br />
Fax 0058.212.2424552<br />
Tlx 24780 Maica V<br />
www.maica-ve.com - maica@telcel.net.ve<br />
HEADQUARTERS<br />
BONFIGLIOLI RIDUTTORI S.p.A.<br />
Via Giovanni XXIII, 7/A<br />
<strong>400</strong>12 Lippo di Calderara di Reno<br />
Bologna (ITALY)<br />
Tel. (+39) 051 6473111<br />
Fax (+39) 051 6473126<br />
www.bonfiglioli.com<br />
bonfiglioli@bonfiglioli.com<br />
SPARE PARTS BONFIGLIOLI<br />
B.R.T.<br />
Via Castagnini, 2-4<br />
Z.I. Bargellino - <strong>400</strong>12<br />
Calderara di Reno - Bologna (ITALY)<br />
Tel. (+39) 051 727844<br />
Fax (+39) 051 727066<br />
www.brtbonfiglioliricambi.it<br />
brt@bonfiglioli.com
INDUSTRY PROCESS<br />
AND AUTOMATION SOLUTIONS<br />
COD. VEC 104 R1<br />
<strong>VCB</strong> <strong>400</strong><br />
www.bonfiglioli.com