09.02.2013 Views

JORDAHL - bolts - Spanelas

JORDAHL - bolts - Spanelas

JORDAHL - bolts - Spanelas

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installation Instructions<br />

Typ of <strong>bolts</strong><br />

for <strong>JORDAHL</strong> - <strong>bolts</strong><br />

Serrated<br />

<strong>bolts</strong><br />

Typ JXD, JXH<br />

Typ JZS<br />

T-head<br />

Hammer-head<br />

<strong>bolts</strong><br />

<strong>bolts</strong><br />

Typ JA, JB Typ JD, JUD<br />

Typ JC, JE<br />

Typ JH, JUH<br />

<strong>JORDAHL</strong> - anchor channel according to approval:<br />

JTA/JTA-R<br />

JXA<br />

Z-21.4-151<br />

Z-21.4-1690<br />

Marking on the<br />

bolt head<br />

JZA<br />

Z-21.4-741<br />

Marking two<br />

slots to check the correct<br />

enagement of the bolt<br />

Selection of <strong>JORDAHL</strong> - <strong>bolts</strong> to fit to the <strong>JORDAHL</strong> - anchor channel<br />

JTA-K 72/48<br />

72<br />

33<br />

JXA-W 38/23<br />

38<br />

18<br />

Marking one slot to check<br />

the correct engagement<br />

of the bolt<br />

Also applicable for <strong>JORDAHL</strong> - framing channels.<br />

JTA-W 74/48<br />

74<br />

33<br />

JA M20-30<br />

48<br />

JA M20-30<br />

23<br />

48<br />

JXH M12-16<br />

JUH M16<br />

R<br />

<strong>JORDAHL</strong><br />

FIXING TECHNOLOGY<br />

JTA-W 54/43<br />

54<br />

JTA-K 53/34<br />

53<br />

22<br />

JXA-W 29/20<br />

29<br />

14<br />

Headquarter Germany:<br />

Deutsche Kahneisen<br />

Gesellschaft mbH<br />

Nobelstraße 51-55<br />

12057 Berlin<br />

Phone: 0049 30 6 82 83 02<br />

Fax: 0049 30 6 82 83 497<br />

Technical<br />

Dept.: 0049 30 6 82 83 498 info@jordahl.de<br />

Sales: 0049 30 6 82 83 494 www.jordahl.de<br />

26<br />

JB M10-20<br />

20<br />

43<br />

JB M10-20<br />

JE M24<br />

34<br />

JXD M10-12<br />

JUD M12<br />

JTA-W 53/34<br />

22<br />

53<br />

22<br />

JTA-K50/30<br />

50<br />

JB M10-20<br />

31<br />

JB M10-20<br />

JZA-K 41/22<br />

41<br />

22<br />

34<br />

18<br />

JTA-K 40/25<br />

22<br />

40<br />

Strength grade / material grade<br />

steel<br />

stainless steel<br />

25<br />

JZS M12-16<br />

4.6<br />

8.8<br />

A4 - 50<br />

A4 - 70<br />

FA - 70<br />

22<br />

JC M10-16<br />

JB M10-20<br />

JTA-K 38/17<br />

18<br />

Strength grade 4.6 (elektroplated or hot dip galvan.)<br />

Strength grade 8.8 (elektroplated or hot dip galvan.)<br />

Stainless steel A4 , material grade 50<br />

Stainless steel A4 , material grade 70<br />

Stainless steel 1.4462 , material grade 70<br />

38<br />

17<br />

JH M10-12<br />

JUH M16<br />

Explaination of the bolt markings<br />

<strong>JORDAHL</strong>-<br />

Indicates manufacturer<br />

bolt typ<br />

Strength grade / material grade<br />

<strong>JORDAHL</strong> - <strong>bolts</strong> and <strong>JORDAHL</strong> - channels are a complete<br />

systems according the approval.<br />

The use of any other <strong>bolts</strong> is not admissible.<br />

JTA-W 50/30<br />

50<br />

JB 4.6 Herst.<br />

30<br />

JTA-W 40/22<br />

40<br />

18<br />

JTA-K 28/15<br />

28<br />

12<br />

JOS - 05/06<br />

Page 1/2<br />

23<br />

1)<br />

JC M10-16<br />

[dimensions in mm]<br />

15<br />

JD M6-10<br />

JUD M12<br />

framing channel<br />

JM K 21/12<br />

21<br />

11<br />

JG M 6-8<br />

Use <strong>JORDAHL</strong>- <strong>bolts</strong><br />

always in combination<br />

with the hexagonal nuts,<br />

which are supplied<br />

together with the <strong>bolts</strong>.<br />

12


Installation Instructions<br />

for <strong>JORDAHL</strong> - <strong>bolts</strong><br />

Removing the foam filler the anchor channel after striking the foam work<br />

After striking the foam work remove the fixing of concrete sedimentation.<br />

After wards remove the foam filler.<br />

Fig. 1<br />

Fig. 4<br />

Fig. 6<br />

Polystyrene bead filler<br />

Fixing the <strong>JORDAHL</strong> - bolt to the <strong>JORDAHL</strong> - anchor channel<br />

Fig. 3<br />

Use an appropriate<br />

tool (c.g. carpenters,<br />

hammer, hook with<br />

flat tip or similar.<br />

cast in anchor channel<br />

M D<br />

Fig. 5<br />

Nm<br />

<strong>JORDAHL</strong>- bolt<br />

with nut<br />

bolttype<br />

JA, JB<br />

JC, JE<br />

JD/JUD<br />

JH/JUH<br />

JXD<br />

JXH<br />

JZS<br />

Fig. 2<br />

After fixing: check the correct fit of the <strong>JORDAHL</strong> - bolt.<br />

The groove on the shank end of the bolt must be perpendicular to<br />

the channel longitudinal axis.<br />

Fig. 4:<br />

If the face of the channel is recessed from the concrete surface,<br />

then shims must be used between the face of the channel and<br />

the back of the component in order to create a flush surface.<br />

Note: The admissible bending moment of the <strong>JORDAHL</strong> - bolt<br />

may not be exceeded.<br />

Fig. 5:<br />

Washers should always be used under the nut.<br />

For space mounting use the special washers.<br />

The admissible bending moment of the <strong>JORDAHL</strong> - bolt<br />

may not be exceeded.<br />

Fig. 6:<br />

Tighten the nuts to the recommended torque according to the table.<br />

Strength/<br />

material<br />

grade<br />

4.6<br />

A4-50/70<br />

FA-70<br />

8.8<br />

8.8<br />

FA-70<br />

8.8<br />

A4-50<br />

Combination strip filler<br />

M 6<br />

3<br />

8<br />

Recommended torques [Nm]<br />

M 8 M 10 M 12 M 16 M 20 M 24 M 27 M 30<br />

15 25 60<br />

48 70<br />

40<br />

80<br />

200<br />

120<br />

50 90<br />

JOS - 05/06<br />

Page 2/2<br />

Catch the strip<br />

on one end by<br />

hand and pull it<br />

out with the aid<br />

of a tool, e.g.<br />

a scew driver.<br />

Fig. 3:<br />

The <strong>JORDAHL</strong> - bolt can be inserted into the channel slot at any<br />

point along the channel length. After a 90° turn clockwise, the<br />

head of the bolt locks into position to enable the nut to be tightened.<br />

<strong>JORDAHL</strong> - <strong>bolts</strong> must not be mounted closer than 25 mm from<br />

the end of a channel.<br />

120 200 300<br />

400<br />

400 680 1000 1400

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!