10.02.2013 Views

Directory of Cyclotrons used for Radionuclide Production in Member ...

Directory of Cyclotrons used for Radionuclide Production in Member ...

Directory of Cyclotrons used for Radionuclide Production in Member ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2005 COUNTRY: JAPAN JPN-24<br />

[1] INSTITUTE: Nihon Medi-Physics Co. Ltd. Chiba Facility<br />

3-1 Kitasode, Sodegaura City<br />

Chiba Pref., 299-0266<br />

TELEPHONE NO.:<br />

E-MAIL ADDRESS:<br />

+81 438 634 771<br />

FAX NO.:<br />

+81 438 633 306<br />

[2] PERSON IN CHARGE:<br />

Dr. Masaji Takahashi<br />

POSITION:<br />

OTHER SENIOR STAFF:<br />

NAME/POSITION<br />

Manager <strong>of</strong> Technical Section 1<br />

[3] TYPE OF<br />

AVF YEAR OF: (I)<br />

1986<br />

CYCLOTRON:<br />

INSTALLATION<br />

MANUFACTURER: Sumitomo Heavy<br />

Industries<br />

(II) UPGRADE:<br />

MODEL: 750 PV<br />

[4] CYCLOTRON CHARACTERISTICS:<br />

1<br />

H<br />

2<br />

H<br />

3<br />

He<br />

4<br />

He Dual Beams<br />

Beam energies (MeV) 30 Yes No<br />

Maximum beam available (µA) 130/55<br />

Typical beam employed (µA) 120/50<br />

[5] CYCLOTRON OPERATION:<br />

Total hours (h)/ week h/week <strong>for</strong> radionuclide h/week <strong>for</strong> h/week <strong>for</strong><br />

h/week <strong>for</strong><br />

production<br />

research<br />

ma<strong>in</strong>tenance applications<br />

130 90 40<br />

[6] CYCLOTRON APPLICATIONS: h/week h/week<br />

Radiobiology: Radiography:<br />

Materials science: Proton therapy:<br />

Physics: Neutron therapy:<br />

Activation analysis: Other (specify)<br />

[7] IS THE CYCLOTRON USED TO PRODUCE:<br />

Calibration sources? (specify which & quantity) Yes No<br />

Mössbauer sources? (specify which & quantity) Yes No<br />

X ray sources? (specify which & quantity) Yes No<br />

Intense neutron beam? (specify average En = ?) Yes No<br />

[8] <strong>Radionuclide</strong>s and radiopharmaceuticals planned to be produced <strong>in</strong> the next 1-3 years (specify):<br />

18 F<br />

[9] Do you supply radionuclides to other <strong>in</strong>stitutions?<br />

If yes and available, name <strong>of</strong> <strong>in</strong>stitution/s & how <strong>of</strong>ten? — everyday to hospitals.<br />

Yes No<br />

[10] Are cl<strong>in</strong>ical studies and/or medical research us<strong>in</strong>g cyclotron radiopharmaceuticals carried<br />

out on-site?<br />

Yes No<br />

[11] TYPE OF IMAGING EQUIPMENT AVAILABLE ON-SITE Number<br />

� 511 KeV co<strong>in</strong>cidence<br />

� Gamma camera<br />

� S<strong>in</strong>gle photon tomography (SPET)<br />

� Positron emission tomography (PET)<br />

– Cl<strong>in</strong>ical<br />

– Small animal<br />

– Plant biochemistry<br />

[12] Are cyclotron radionuclides/labelled compounds <strong>used</strong> or planned to be <strong>used</strong> <strong>for</strong><br />

agricultural applications such as plant biochemistry/research?<br />

Yes No<br />

[13] Is the cyclotron <strong>used</strong> <strong>for</strong> nuclear reaction cross-section measurements? Yes No<br />

[14] Is the cyclotron <strong>used</strong> <strong>for</strong> targetry development? Yes No<br />

[15] Is the cyclotron <strong>used</strong> <strong>for</strong> education and tra<strong>in</strong><strong>in</strong>g <strong>in</strong> nuclear sciences, health physics, etc.? Yes No<br />

[16] Does your <strong>in</strong>stitute accept IAEA research fellows <strong>for</strong> tra<strong>in</strong><strong>in</strong>g/experience? Yes No<br />

239<br />

233

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!