HEMPEL<br />

TANKS - VENTILATION R 14<br />

SOLVENT VAPOURS ARE MORE HEAVY THAN AIR.<br />

Therefore they always tend to go to the bottom of confined spaces<br />

and consequently their removal must always take place by suction<br />

from the lower part of such areas.<br />

Control both Inlet Air and Exhaust Air<br />

Exhaust by suction is the normal way - but to fully control the<br />

ventilation flow, forced inlet blowing should always be used in<br />

cooperation with the suction.<br />

Forced inlet blowing is also necessary when controlling the<br />

atmosphere in the confined space through dehumidifiers.<br />

Sometimes general ventilation is not enough.<br />

Local areas inside the confined space may not be sufficiently<br />

ventilated via the general ventilation installation.<br />

To secure ventilation of the local areas ex-proof portable<br />

blowers can be put in these areas.<br />

GENERAL<br />

VENTILATION FLOW<br />

VENTILATE BY<br />

EXPROOF BLOWER<br />

FORCED INLET<br />

BLOWING AT TOP<br />

EXHAUST SUCTION<br />

AT BOTTOM<br />

INSPR14 ed2 VALIDITY SUBJECT TO CONFIRMATION 30/04/97 EMi