14.02.2013 Views

MULTISTAGE CENTRIFUGAL PUMP TYPE SLM GV - Klaus Union

MULTISTAGE CENTRIFUGAL PUMP TYPE SLM GV - Klaus Union

MULTISTAGE CENTRIFUGAL PUMP TYPE SLM GV - Klaus Union

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Production range<br />

pumps:<br />

Pumps with magnet drive<br />

E Centrifugal pumps<br />

according to DIN EN 22858<br />

E Centrifugal pumps<br />

according to ANSI B73.3<br />

E Centrifugal pumps for refinery<br />

and petrochemical applications<br />

according to API 685<br />

E Centrifugal pumps for high<br />

pressure applications<br />

E Centrifugal pumps for high<br />

temperature applications<br />

E Centrifugal pumps for liquid<br />

containing solids<br />

E Centrifugal pumps, self-priming<br />

E Multistage pumps, tension-rod or<br />

barrel-type construction<br />

E Side channel pumps, self-priming<br />

E Screw pumps<br />

E Submerged centrifugal pumps<br />

E Double suction centrifugal pumps<br />

<strong>Klaus</strong> <strong>Union</strong> GmbH & Co. KG<br />

Blumenfeldstr. 18<br />

44795 Bochum<br />

Germany<br />

Phone +49 234 45 95 - 0<br />

Fax +49 234 45 95 - 7000<br />

E-Mail info@klaus-union.de<br />

Internet www.klaus-union.de<br />

Pumps with shaft sealing<br />

E Centrifugal pumps<br />

according to DIN EN 22858<br />

E Multistage pumps, tension-rod or<br />

barrel-type construction<br />

E Horizontal and vertical propeller pumps<br />

E Bottom-flange propeller pumps<br />

E Submerged centrifugal pumps<br />

E Double-suction chemical pumps<br />

Production range<br />

valves:<br />

E Valves, T-pattern<br />

E Valves, Y-pattern<br />

E Gate valves, isomorphous<br />

construction series<br />

E Gate valves, wedge or wedge plates<br />

E Relief valves<br />

E Check valves<br />

E Sight glasses<br />

E Strainers<br />

E Filters<br />

E Bottom valves<br />

KU_<strong>GV</strong>_E_01/11_0001<br />

S E R V I C E<br />

<strong>MULTISTAGE</strong> <strong>CENTRIFUGAL</strong><br />

<strong>PUMP</strong> <strong>TYPE</strong> <strong>SLM</strong> <strong>GV</strong><br />

SEALLESS WITH MAGNET DRIVE


2<br />

Sealless multistage centrifugal<br />

construction series <strong>SLM</strong> <strong>GV</strong><br />

As a member of <strong>Klaus</strong> <strong>Union</strong>’s successful<br />

modular pump concept, the <strong>SLM</strong> <strong>GV</strong> further<br />

extends our sealless application coverage.<br />

The <strong>SLM</strong> <strong>GV</strong> pump is primarily used for applications<br />

requiring high delivery heads.<br />

Requirements have increased, become<br />

more complex, and more specific in recent<br />

years, particularly in the chemical and<br />

petrochemical industry, where pumps handle<br />

aggressive, toxic, and explosive liquids under<br />

highest safety requirements. <strong>Klaus</strong> <strong>Union</strong>’s<br />

new <strong>SLM</strong> <strong>GV</strong> pump series addresses today‘s<br />

industry requirements – and offers new<br />

efficient and demand-driven solutions.<br />

<strong>Klaus</strong> <strong>Union</strong> satisfies these requirements<br />

with over fifty years of experience in development,<br />

construction, manufacturing, and in the<br />

application of magnet drive pumps.<br />

<strong>SLM</strong> <strong>GV</strong> – “V” stands for “variable” through<br />

modular design. Features and benefits of the<br />

modular “V-Concept” are:<br />

E Few individual components –<br />

multi-functional, individual application<br />

E Greater safety over the<br />

entire construction range<br />

E Suitable for serial fabrication<br />

at competitive prices<br />

E Standard modules offer<br />

many design variations<br />

E Energy efficient systems<br />

E Maximum flexibility and interchangeability<br />

E Off-the-shelf availability of parts,<br />

components and accessories<br />

The construction series <strong>SLM</strong> <strong>GV</strong> covers the<br />

complete performance range of multistage<br />

centrifugal pumps. Pumps for high system<br />

pressure applications are also available upon<br />

request.<br />

<strong>SLM</strong> <strong>GV</strong>OT Barrel construction type design <strong>SLM</strong> <strong>GV</strong>S tension rod construction design<br />

Safety and environmental protection<br />

Quality assurance<br />

A major component of our Company ethos is<br />

to ensure the highest quality of our products.<br />

Existing quality assurance procedures with our<br />

suppliers are constantly monitored from order<br />

placement, goods inward through to final<br />

assembly. This quality assurance system, developed<br />

on modern principles, complies with<br />

the requirements of international regulations.<br />

<strong>Klaus</strong> <strong>Union</strong> is a DIN EN ISO 9001 certified<br />

Company.<br />

Pumping of<br />

E Acids<br />

E Lyes<br />

E Hydrocarbon<br />

E Hot water (boiler water)<br />

E Heat transfer liquids<br />

E Liquid gas<br />

E Aggressive, explosive and<br />

toxic liquids<br />

Domains<br />

E Chemical and petrochemical industries<br />

E Refrigeration and heat<br />

E Liquid gas plants<br />

E Galvanic engineering<br />

E Power stations<br />

E Tank installations<br />

Performance range<br />

Flow rate: Q = up to 350 m³ /h<br />

Delivery head: H = up to 700 m L. C.<br />

Higher flow rates and delivery heads<br />

upon request<br />

Pressure ratings/temperature ranges<br />

Standard construction: PN 40 / PN 63<br />

at 120 °C<br />

Temperature range: -120 °C up to +450 °C<br />

Higher pressure ratings upon request<br />

3


1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

Constructional details <strong>SLM</strong> <strong>GV</strong>OT<br />

Barrel-type construction<br />

6.<br />

7.<br />

8.<br />

9.<br />

10.<br />

11.<br />

12.<br />

1. Barrel-type pump casing<br />

PN 40 / PN 63 at 120 °C;<br />

Suction nozzle with horizontal inlet<br />

Optionally with heating jacket<br />

2. Flushing system<br />

Pressurised to safely handle liquids close<br />

to boiling<br />

3. Radial journal bearing<br />

Radial journal bearing behind<br />

the suction impeller<br />

4. Impellers<br />

Arranged in series;<br />

First stage with suction impeller<br />

Optionally with suction inducer to reduce<br />

required NSPH<br />

5. Balancing holes<br />

Optimized thrust loads over the entire<br />

operating range via hydraulic measures<br />

6. Outer magnet carrier<br />

Two piece with rub ring on the<br />

intermediate lantern<br />

7. Isolation shell<br />

Self-venting and fully drainable;<br />

Vortex breaker<br />

8. Journal bearings<br />

Double bearing made of SSiC;<br />

Counter centred combination for universal<br />

utilisation over a wide temperature range<br />

9. Bearing support<br />

Oil-lubricated anti-friction bearings:<br />

<strong>SLM</strong> <strong>GV</strong>OT design<br />

Optionally with grease-lubricated<br />

anti-friction bearings: <strong>SLM</strong> <strong>GV</strong>ST design<br />

10. Inner magnet carrier<br />

With rub ring on the journal bearing bush<br />

11. Intermediate lantern<br />

With outer magnet carrier rub ring and<br />

assembly/disassembly guidance<br />

12. Static gasket<br />

Merely two static gaskets on isolation shell<br />

and casing<br />

4 5


Head [ m ]<br />

Head [ m ]<br />

Performance curve 50Hz<br />

135<br />

120<br />

105<br />

90<br />

75<br />

60<br />

45<br />

15<br />

0<br />

0<br />

550<br />

500<br />

450<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

50<br />

0<br />

0<br />

<strong>SLM</strong> <strong>GV</strong><br />

<strong>SLM</strong> <strong>GV</strong><br />

080-040-200/6<br />

<strong>SLM</strong> <strong>GV</strong><br />

30<br />

065-032-160/6<br />

<strong>SLM</strong> <strong>GV</strong><br />

080-040-200/6<br />

065-032-160/6<br />

100<br />

<strong>SLM</strong> <strong>GV</strong> 100-050-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 100-050-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 125-065-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 125-065-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 150-080-250/4<br />

<strong>SLM</strong> <strong>GV</strong> 150-080-250/4<br />

<strong>SLM</strong> <strong>GV</strong> 150-100-250/4<br />

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160<br />

50 100 150 200 250 300 350 400 450 500 550 600 650 700<br />

Performance curve 50Hz<br />

1450 1/min<br />

2900 1/min<br />

<strong>SLM</strong> <strong>GV</strong> 150-100-250/4<br />

25 50 75 100 125 150 175 200 225 250 275 300<br />

100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

1800<br />

1600<br />

1400<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

Head [ ft ]<br />

Flowrate<br />

[ m³/h ]<br />

Flowrate<br />

[ usgpm ]<br />

Head [ ft ]<br />

Flowrate<br />

[ m³/h ]<br />

Flowrate<br />

[ usgpm ]<br />

Head [ m ]<br />

Head [ m ]<br />

Performance curves <strong>SLM</strong> <strong>GV</strong><br />

Performance curve 60Hz<br />

180<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

065-032-160/6<br />

40<br />

20<br />

750<br />

700<br />

600<br />

500<br />

400<br />

300<br />

100<br />

0<br />

0<br />

0<br />

0<br />

<strong>SLM</strong> <strong>GV</strong><br />

<strong>SLM</strong> <strong>GV</strong><br />

080-040-200/6<br />

200<br />

<strong>SLM</strong> <strong>GV</strong><br />

065-032-160/6<br />

<strong>SLM</strong> <strong>GV</strong> 100-050-250/5 <strong>SLM</strong> <strong>GV</strong> 125-065-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 150-080-250/4<br />

1750 1/min<br />

<strong>SLM</strong> <strong>GV</strong> 150-100-250/4<br />

15 30 45 60 75 90 105 120 135 150 165 180 190<br />

50 100<br />

200<br />

300<br />

400<br />

500<br />

600<br />

700<br />

800<br />

Performance curve 60Hz<br />

<strong>SLM</strong> <strong>GV</strong><br />

080-040-200/6<br />

<strong>SLM</strong> <strong>GV</strong> 100-050-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 125-065-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 150-080-250/4<br />

3500 1/min<br />

<strong>SLM</strong> <strong>GV</strong> 150-100-250/4<br />

25 50 75 100 125 150 175 200 225 250 275 300 325 350 375<br />

100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600<br />

6 7<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

250<br />

Head [ ft ]<br />

Flowrate<br />

[ m³/h ]<br />

Flowrate<br />

[ usgpm ]<br />

2250<br />

2000<br />

1750<br />

1500<br />

1250<br />

1000<br />

750<br />

500<br />

250<br />

Head [ ft ]<br />

Flowrate<br />

[ m³/h ]<br />

Flowrate<br />

[ usgpm ]