- Page 1: TÓPICOS EM DETECÇÃO QUÍMICA UTI
- Page 5 and 6: Transductor: [ETYMOLOGY: 20th Centu
- Page 7 and 8: Sistema: [ETYMOLOGY: 17th Century:
- Page 9 and 10: Sequência de detecção (Sensibili
- Page 11 and 12: Ambientes complexos
- Page 13 and 14: HISTÓRICO DO DESENVOLVIMENTO DE SE
- Page 15 and 16: I-STAT Chemfet (quimio-transistor)
- Page 18 and 19: TAS: Micro Total Analysis System An
- Page 20 and 21: -ChemLab (Sandia) http://www.ca.san
- Page 22 and 23: Qual sensor utilizar
- Page 24 and 25: QUIMIO-RESISTORES Óxidos metálico
- Page 26 and 27: QUIMIO-RESISTORES Seletividade / se
- Page 28 and 29: QUIMIO-RESISTORES Cristais orgânic
- Page 30 and 31: QUIMIO-CAPACITORES
- Page 32 and 33: Quimio-Diodos Pd Semicondutor
- Page 34 and 35: Quimio-transistores Porous Pd gate
- Page 36 and 37: Chemfets - materiais
- Page 38 and 39: Teoria dos Centros Ativos
- Page 40: ISE -> CHEMFET
- Page 47 and 48: Sensores Potenciométricos ISE - io
- Page 49 and 50: Membrana de vidro Vidro (pH - 1922)
- Page 51 and 52: Membrana de vidro (gases) E = cte -
- Page 53 and 54:
Membranas poliméricas com ionófor
- Page 55 and 56:
Detecção de K +
- Page 57 and 58:
CWE (coated-wire electrode)
- Page 59 and 60:
Quimio-transistores pH Urea
- Page 61 and 62:
Sensor de Oxigênio V = -800 mV | A
- Page 63 and 64:
Sensor de Glicose V = +600 mV | AgA
- Page 65 and 66:
Sensor de Colesterol V = - 50 mV |
- Page 67 and 68:
Glucose - Commercial applications (
- Page 69 and 70:
Detecção Eletroanalítica de meta
- Page 71 and 72:
Curva de Calibração Finalmente um
- Page 73 and 74:
LTCC Processing
- Page 75 and 76:
Resultados (Hg)
- Page 77 and 78:
Implantes DEVELOPMENT OF AN ARRAY O
- Page 79 and 80:
AMPEROMETRIC DETECTION NO NO 2- N
- Page 81 and 82:
MICROMACHINING TECHNIQUES Boron etc
- Page 83 and 84:
FABRICATION RESULTS - SEM and AFM H
- Page 85 and 86:
FABRICATION RESULTS - FINAL DEVICE
- Page 87 and 88:
SENSOR DESIGN SENSOR 3 x 10 mm FEAT
- Page 89 and 90:
Tecnologia de modificação de elet
- Page 91 and 92:
Self-Assembled Monolayers (SAM) of
- Page 93 and 94:
Porphryrins Nickel-Tetrakis Porphyr
- Page 95 and 96:
ELECTROCHEMICAL DETECTION : DPV PAR
- Page 97 and 98:
IN VITRO DETECTION ELECTROCHEMICAL
- Page 99 and 100:
NITRIDE SENSITIVITY 8.67 x 10 -5 A
- Page 101 and 102:
SENSOR'S RESPONSE : NITRIC OXIDE CO
- Page 103 and 104:
Aplicações médicas
- Page 105 and 106:
Aplicações médicas
- Page 107 and 108:
Aplicações médicas
- Page 109 and 110:
Microelectrodes Array
- Page 111 and 112:
Microelectrodes Array
- Page 113 and 114:
Sensores de massa Sensor SAW (LiNbO
- Page 115 and 116:
Sensores ópticos
- Page 117:
Evanescent field Chemical Optical S