Ciprea <strong>20</strong>4.3 Technical data tablePowers Pmax PminHeating Power (Net Heat Value - Hi) kW 25,8 11,5Available Thermal Power 80°C - 60°C kW 23,5 9,7Hot Water Heating Power kW 23,5 9,7Gas supply Pmax PminNatural Gas main nozzles (G<strong>20</strong>) mm 11x1.35Natural Gas supply pressure (G<strong>20</strong>) mbar <strong>20</strong>,0Pressure at Natural Gas burner (G<strong>20</strong>) mbar 11,8 2,5Natural Gas delivery (G<strong>20</strong>) nm3/h 2,73 1,22LPG main nozzles (G31) mm 11x0.79LPG supply pressure (G31) mbar 37,0Pressure at LPG burner (G31) mbar 36,0 7,2LPG delivery (G31) kg/h 2,00 0,89HeatingMaximum working temperature in heating °C 90Maximum working pressure in heating bar 3Minimum working pressure in heating bar 0,8Expansion tank capacity litres 8Expansion tank pre-filling pressure bar 1Boiler water content litres 0.5Energy Efficiency Marking (EEC 92/42) **Hot waterMaximum hot water production ∆t 30°C l/min 11,2Maximum working pressure in hot water production bar 10Minimum working pressure in hot water production bar 0,25Hot water content litres 0,3Electrical power supplyMax electrical power absorbed W 85Power voltage/frequency V/Hz 230/50Electrical protection rating IP X4DBoiler weight kg 254.4 DiagramsPressure - power diagramsHead available for the systemG31LPG65mbarG<strong>20</strong>NaturalH [m H 2O]43gas21kW00 500 1.000 1.500 2.000Q [l/h]32