Installation Instructions Section 2<br />
Maximum Breaker Size & Minimum Circuit Amperage Chart<br />
Important<br />
Due to continuous improvements, this information is for reference only.<br />
Please refer to the ice machine serial number tag to verify electrical data.<br />
Serial tag information overrides information listed on this page.<br />
Series Ice<br />
Machine<br />
Voltage<br />
Phase<br />
Cycle<br />
Max<br />
Fuse/<br />
Circuit<br />
Breaker<br />
QUIETQUBE REMOTE CONDENSING UNIT<br />
Air-Cooled Water-Cooled QuietQube<br />
Min<br />
Circuit<br />
Amps<br />
Total<br />
Circuit<br />
Amps<br />
Max<br />
Fuse/<br />
Circuit<br />
Breaker<br />
Min<br />
Circuit<br />
Amps<br />
Max<br />
Fuse/<br />
Circuit<br />
Breaker<br />
Total<br />
Circuit<br />
Amps<br />
<strong>RF</strong>0244<br />
115/1/60 15 Amp N/A 7.5 N/A N/A — —<br />
230/1/50 10 Amp N/A 0.87 N/A N/A — —<br />
<strong>RF</strong>0266<br />
115/1/60 15 Amp N/A 7.5 N/A N/A — —<br />
230/1/50 10 Amp N/A 0.87 N/A N/A — —<br />
<strong>RF</strong>0385<br />
115/1/60 15 Amp N/A 10.0 N/A N/A — —<br />
230/1/50 N/A N/A N/A N/A N/A — —<br />
<strong>RF</strong>0388<br />
115/1/60 15 Amp N/A 10.0 N/A N/A — —<br />
230/1/50 10 Amp N/A 2.9 N/A N/A — —<br />
<strong>RF</strong><strong>0399</strong><br />
115/1/60 15 Amp N/A 10.0 N/A N/A — —<br />
230/1/50 10 Amp N/A 2.9 N/A N/A — —<br />
<strong>RF</strong>0644 115/1/60 25 Amp N/A 13.5 N/A N/A — —<br />
<strong>RF</strong>S0300 115/1/60 20 Amp 12.8 N/A N/A N/A — —<br />
<strong>RF</strong>S0650<br />
115/60/1 25 Amp 16.3 N/A 25 Amp 15.4 — —<br />
208-230/1/60 15 Amp 8.7 N/A 15 Amp 8.2 — —<br />
<strong>RF</strong>1200<br />
208-230/1/60 15 Amp 15.0 N/A 15 Amp 15.0 15 Amp 1.4<br />
230/1/50 16 Amp 7.3 N/A 16 Amp 7.3 10 Amp 1.4<br />
<strong>RF</strong>2300<br />
208-230/3/60 20 Amp 15.0 N/A 20 Amp 15.0 15 Amp 3.2<br />
400-415/3/50 16 Amp 13.9 N/A 16 Amp 13.9 10 Amp 3.2<br />
<strong>RF</strong>1200R 208-230/1/60 15 Amp 1.4 N/A N/A N/A — —<br />
<strong>RF</strong>2300R 208-230/3/60 15 Amp 3.2 N/A N/A N/A — —<br />
Maximum allowable voltage variation at compressor start-up is ±10% of voltage listed above and on the model/serial plate.<br />
Condensing Unit Voltage Phase Cycle Maximum Fuse/Circuit Breaker Minimum Circuit Amps<br />
208-230/60/1 15 15<br />
RCU1075<br />
208-230/60/3 15 15<br />
208-230/50/1 15 15<br />
208-230/60/1 15 15<br />
RCU2375<br />
208-230/60/3 15 15<br />
208-230/50/1 15 15<br />
9 Part Number 000007644 3/11