10.07.2015 Views

submersible effluent & sewage pumps rl series - Red Lion

submersible effluent & sewage pumps rl series - Red Lion

submersible effluent & sewage pumps rl series - Red Lion

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

INSTALLATIONTABLE 1Approximate 'pumpable volume' (gallons) for variouscombinations of basin diameters and fl oat switch tethe<strong>rl</strong>engths.....Tether Length Of Float Switch (inches)Tank6 8 10 12 14 16BasinApprox. Float Switch Range (inches)Dia.(inches)10 12 16 18 22 25Pumped Volume (U.S. Gallons)18 11 13 17 20 - -24 20 23 31 35 43 4930 31 37 49 55 67 7636 44 53 70 79 97 11048 78 94 125 141 172 19560 122 147 196 220 269 30572 176 211 282 317 387 4404. PLUMBING: PUMP AND DISCHARGE PIPINGa) Use steel or plastic pipe for all connecting linesbetween pump and sewer outlet. Keep pipe lengthto a minimum to reduce friction losses. Pump isequipped with a 2" NPT female outlet - DO NOTREDUCE TO A SMALLER SIZE.NOTE: Fluid fl ow velocity in the pump's discharge linemust be at least two feet per second to carrythe effl uent without clogging. This is ensuredif pump fl ow is at least:• 21 GPM through a 2" pipe• 30 GPM through a 2-1/2" pipe• 46 GPM through a 3" pipeWARNING: Some city regulations DO NOT allowthe installation of a pump with plastic pipe. Check localregulations.b) A union or quick disconnect connection should beinstalled to facilitate pump removal if necessary. AFULL FLOW CHECK VALVE IS RECOMMENDEDAFTER THE UNION TO PREVENT BACKFLOWAFTER EACH PUMPING CYCLE.NOTE: When a check valve is used, drill a 1/8" or3/16" air relief hole in the discharge pipe.This hole should be located below the fl oo<strong>rl</strong>ine within the sealed pump unit and betweenthe pump and check valve (see Fig. 2 & 3).Without this relief hole, the pump can air lockand will not pump even though it will run.5. MOUNTING THE FLOAT SWITCH:AUTOMATIC OPERATION MODELS ONLYa) All automatic models; Single Phase 115 voltmodels come supplied with a float switch for mountingto the pump's discharge pipe and requires finaladjustment to suit your systems needs.b) The fl oat switch is equipped with a cord and 115volt grounded piggyback plug confi guration (dependingon the voltage rating of the model youhave). The switch provides automatic operationof the pump in water, effl uent and <strong>sewage</strong> applications.WARNING - RISK OF ELECTRICAL SHOCKc) The fl oat switch is packaged separately within thepump carton and includes the switch manufacturer'sassembly, adjustment, operation, safetyand cautionary instructions. Follow the manufacturer'sinstructions explicitly for properinstallation and operation. The free length ofcable must be at least 4" to allow free movementof the float.6. MANUAL MODELS:SINGLE PHASE 115 VAC MODELSa) Single Phase 115 volt manual models DO NOTINCLUDE A FLOAT SWITCH.b) The pump comes equipped with a power cord and115 volt grounded plug confi guration (dependingon the voltage rating of the model you have).c) Plug in or unplug pump power cord as needed intoground fault interrupter (GFI) protected circuit oruse with an approved motor control that matchesthe pump/motor input rated amperes. The motorcontrol must be prope<strong>rl</strong>y sized for the pump,installed and wired in compliance with the NationalElectrical Code (NEC) and any local codes andordinances.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!