6.1 Central lubricating system<br />
Proper lubrication of the spindle bearings and brake band<br />
is essential for trouble-free operation and long life for the<br />
machine. The central lubricating system makes this a very<br />
easy procedure.<br />
Check the reservoir and refill if necessary with SAE 30<br />
weight lubricating oil into inlet.<br />
Once a day, before starting the machine for the first<br />
time, lift and release the lubricator plunger six times.<br />
During normal operation, lift and release the plunger<br />
four times every two hours of operation.<br />
Replace filter element once a year on the central<br />
lubricator pump.<br />
6.2 Changing the jaws<br />
Keep clean with wire bush to avoid slippage. To replace jaws:<br />
� Unplug machine<br />
� Remove spindle cover<br />
� Remove jaw retaining rings and slide jaws off shaft<br />
If machine has been used for only right hand threading, reverse jaws and remount on jaw shafts<br />
so that the unused side faces spindle opening.<br />
� Inspect jaw shaft keys for wear.<br />
� Install replacement jaws so that single row jaws (1) are the opposite of each other and<br />
doubles (2) are opposite each other. Also alternate single and double jaws between front (3)<br />
and rear chucks (4).<br />
6.3 Daily inspection<br />
Attention! Before starting the lubrication-works the power plug has to be<br />
taken out of the power source.<br />
� Check the mains plug, mains cable and extension cable to ensure they are undamaged.<br />
� Correctly filled oil trough<br />
� Adjust the oil screw if necessary<br />
� Clean the oil tank if there are impurities in it.<br />
32 ENGLISH<br />
1<br />
2<br />
3<br />
4<br />
inlet plunger<br />
filter element