23.11.2012 Views

Absackstutzen incl. Lederschnalle Sag socke - S&W RohrSysteme

Absackstutzen incl. Lederschnalle Sag socke - S&W RohrSysteme

Absackstutzen incl. Lederschnalle Sag socke - S&W RohrSysteme

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Application range:<br />

- Suitable for fibrous and long foil scraps<br />

- Suitable in all installation positions<br />

- Suitable in all fields of application where no<br />

tightness is needed<br />

Special features:<br />

- Can be operated by standing products in the pipe system<br />

- Very rugged design<br />

- Optional: Solenoid valve and<br />

2 limit switches (Additional charge = 190,20 €)<br />

For notice:<br />

- Shut off sleeve valve without any sealing<br />

(Result: Leakage air / out falling products)<br />

- Not oil-tight!<br />

Special constructions:<br />

- Shut off sleeve valve with flanges on request<br />

- Valve plates with special dimensions on request<br />

Domaines d'application :<br />

- Très bien adapté pour des découpes de film à<br />

copeaux longs<br />

- Position de montage comme souhaité<br />

- Adapté pour tous les domaines d’application<br />

sans exigences quant à l’étanchéité<br />

Particularités :<br />

- Peut être commuté en présence d’une colonne de<br />

produit en position debout<br />

- Le matériau ne peut pas se poser sur la surface de<br />

roulement puisqu’il est<br />

toujours recouvert par la feuille de coulisse<br />

- Forme de construction très robuste et discrète<br />

- Vanne magnétique et 2 commutateurs finaux en<br />

option (majoration = 190,20 €)<br />

Veuillez observer :<br />

- Coulisse entièrement sans étanchements (conséquences :<br />

air issu d’une fuite d’air /<br />

produit chutant hors du dispositif)<br />

- N’est pas étanche à l’huile !<br />

Pièces spéciales :<br />

- Coulisses avec brides sur demande<br />

- Plaques de coulisse avec des dimensions spéciales sur demande<br />

Technical remarks shut off sleeve valve pneumatically operated<br />

(Working pressure 5 bar / shut off sleeve valve is closed by absence of current)<br />

Assembled pneumatic components manuf. Festo:<br />

Cylinders (2 pieces): (for non contact position indicating,<br />

both sides with adjustable damping feature)<br />

Operating pressure (max.) 12 bar<br />

Thermal range of application -20° up to +80° C<br />

Cylinder ø40 (air consumption / cm 0,136 litre<br />

working stroke at 5 bar working pressure)<br />

Cylinder ø50 (air consumption / cm 0,22 litre<br />

working stroke at 5 bar working pressure)<br />

Magnetic field switch with LED (as option)<br />

Thermal range of application -20° up to 60° C<br />

Switching capacity max. 10 W<br />

Nominal voltage 3 V up to 250 V<br />

Type of enclosure IP 65<br />

5/2-way-<br />

solenoid (one side electro-magnetic operated, other side spring<br />

(as option) retraction, manual auxiliary actuation, 2 throttling valves,<br />

2 noise absorbers and connection for hose ø 8 mm)<br />

Nominal width 5 mm<br />

Operating pressure (min./max.) 2,2 bar / 8 bar<br />

Thermal range of application -10° up to +50° C<br />

Isolation class F<br />

Duty cycle 100 %<br />

Type of enclosure IP 65<br />

Voltage 230 V, 50 Hz. / 60 Hz. or 24V/DC<br />

Power consumption of holding 7,5 VA<br />

Power consumption 6,0 VA<br />

Caractéristiques techniques de la vanne tiroir d’obturation (à actionnement pneum.)<br />

(Pression de service 5 bars / Coulisse se ferme en cas de panne de courant)<br />

Modules pneumatiques montés de marque Festo, composés de :<br />

Cylindres (2 pièces) : (pour un affichage de la position sans contacts,<br />

amortissement réglable des deux côtés)<br />

Pression de service (max.):<br />

Domaine d’application thermique<br />

12 bars<br />

-20° à +80° C<br />

Cylindre Ø 40 (consommation d’air / cm 0,136 litres<br />

Course motrice pour 5 bars de pression de service)<br />

Cylindre Ø 50 (consommation d’air / cm<br />

Course motrice pour 5 bars de pression de service)<br />

0,22 litres<br />

Commutateur à champ magnétique avec lampe DEL (en option)<br />

Domaine d’application thermique -20° à 60° C<br />

Puissance de rupture 10 W maximum<br />

Tension de commutation 3 V à 250 V<br />

Indice de protection IP 65<br />

Électrovalve à 5/2 voies<br />

Electrovanne (actionné électromagnétiquement d’un côté, autre côté<br />

(en option) réaction à ressort, actionnement secondaire manuel,<br />

2 vannes d’étranglement, 2 amortisseurs de bruit et<br />

raccordement pour un tuyau de ? 8 mm)<br />

Diamètre nominal 5 mm<br />

Pression de service (min./ max.) 2,2 bars / 8 bars<br />

Domaine d’application thermique -10° à +50° C<br />

Classe d’isolement F<br />

Durée de mise en circuit 100 %<br />

Indice de protection IP 65<br />

Tension 230 V, 50 Hz. / 60 Hz.<br />

Courant de maintien nominal 7,5 VA<br />

Courant de démarrage nominal 6,0 VA<br />

95

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!