Application range:<br />
- Suitable for fibrous and long foil scraps<br />
- Suitable in all installation positions<br />
- Suitable in all fields of application where no<br />
tightness is needed<br />
Special features:<br />
- Can be operated by standing products in the pipe system<br />
- Very rugged design<br />
- Optional: Solenoid valve and<br />
2 limit switches (Additional charge = 190,20 €)<br />
For notice:<br />
- Shut off sleeve valve without any sealing<br />
(Result: Leakage air / out falling products)<br />
- Not oil-tight!<br />
Special constructions:<br />
- Shut off sleeve valve with flanges on request<br />
- Valve plates with special dimensions on request<br />
Domaines d'application :<br />
- Très bien adapté pour des découpes de film à<br />
copeaux longs<br />
- Position de montage comme souhaité<br />
- Adapté pour tous les domaines d’application<br />
sans exigences quant à l’étanchéité<br />
Particularités :<br />
- Peut être commuté en présence d’une colonne de<br />
produit en position debout<br />
- Le matériau ne peut pas se poser sur la surface de<br />
roulement puisqu’il est<br />
toujours recouvert par la feuille de coulisse<br />
- Forme de construction très robuste et discrète<br />
- Vanne magnétique et 2 commutateurs finaux en<br />
option (majoration = 190,20 €)<br />
Veuillez observer :<br />
- Coulisse entièrement sans étanchements (conséquences :<br />
air issu d’une fuite d’air /<br />
produit chutant hors du dispositif)<br />
- N’est pas étanche à l’huile !<br />
Pièces spéciales :<br />
- Coulisses avec brides sur demande<br />
- Plaques de coulisse avec des dimensions spéciales sur demande<br />
Technical remarks shut off sleeve valve pneumatically operated<br />
(Working pressure 5 bar / shut off sleeve valve is closed by absence of current)<br />
Assembled pneumatic components manuf. Festo:<br />
Cylinders (2 pieces): (for non contact position indicating,<br />
both sides with adjustable damping feature)<br />
Operating pressure (max.) 12 bar<br />
Thermal range of application -20° up to +80° C<br />
Cylinder ø40 (air consumption / cm 0,136 litre<br />
working stroke at 5 bar working pressure)<br />
Cylinder ø50 (air consumption / cm 0,22 litre<br />
working stroke at 5 bar working pressure)<br />
Magnetic field switch with LED (as option)<br />
Thermal range of application -20° up to 60° C<br />
Switching capacity max. 10 W<br />
Nominal voltage 3 V up to 250 V<br />
Type of enclosure IP 65<br />
5/2-way-<br />
solenoid (one side electro-magnetic operated, other side spring<br />
(as option) retraction, manual auxiliary actuation, 2 throttling valves,<br />
2 noise absorbers and connection for hose ø 8 mm)<br />
Nominal width 5 mm<br />
Operating pressure (min./max.) 2,2 bar / 8 bar<br />
Thermal range of application -10° up to +50° C<br />
Isolation class F<br />
Duty cycle 100 %<br />
Type of enclosure IP 65<br />
Voltage 230 V, 50 Hz. / 60 Hz. or 24V/DC<br />
Power consumption of holding 7,5 VA<br />
Power consumption 6,0 VA<br />
Caractéristiques techniques de la vanne tiroir d’obturation (à actionnement pneum.)<br />
(Pression de service 5 bars / Coulisse se ferme en cas de panne de courant)<br />
Modules pneumatiques montés de marque Festo, composés de :<br />
Cylindres (2 pièces) : (pour un affichage de la position sans contacts,<br />
amortissement réglable des deux côtés)<br />
Pression de service (max.):<br />
Domaine d’application thermique<br />
12 bars<br />
-20° à +80° C<br />
Cylindre Ø 40 (consommation d’air / cm 0,136 litres<br />
Course motrice pour 5 bars de pression de service)<br />
Cylindre Ø 50 (consommation d’air / cm<br />
Course motrice pour 5 bars de pression de service)<br />
0,22 litres<br />
Commutateur à champ magnétique avec lampe DEL (en option)<br />
Domaine d’application thermique -20° à 60° C<br />
Puissance de rupture 10 W maximum<br />
Tension de commutation 3 V à 250 V<br />
Indice de protection IP 65<br />
Électrovalve à 5/2 voies<br />
Electrovanne (actionné électromagnétiquement d’un côté, autre côté<br />
(en option) réaction à ressort, actionnement secondaire manuel,<br />
2 vannes d’étranglement, 2 amortisseurs de bruit et<br />
raccordement pour un tuyau de ? 8 mm)<br />
Diamètre nominal 5 mm<br />
Pression de service (min./ max.) 2,2 bars / 8 bars<br />
Domaine d’application thermique -10° à +50° C<br />
Classe d’isolement F<br />
Durée de mise en circuit 100 %<br />
Indice de protection IP 65<br />
Tension 230 V, 50 Hz. / 60 Hz.<br />
Courant de maintien nominal 7,5 VA<br />
Courant de démarrage nominal 6,0 VA<br />
95