Stop screwSafeVision Switchbox<strong>Installation</strong> <strong>and</strong> <strong>setting</strong> <strong>instructions</strong>8 MaintenanceHyvision switch boxes require no servicing duringtheir normal working life. In the event of failurereplace parts only with HYTORK suppliedcomponents. In an emergency replace thecomplete switch box.Be sure to disconnect all air <strong>and</strong> electrical suppliesbefore starting any dismantling or maintenance onthe actuator or switchbox.Repair of this equipment shall be carried out bysuitably trained personnel in accordance with theapplicable code of practice e.g. EN 60079-19.EnglishThe top <strong>and</strong> bottom bearings are designed for 5million operations. If this is expected to beexceeded, the user should introduce routinemaintenance to check that the bearing clearancedoes not exceed 0.12 mm.Components to be incorporated into or used asreplacement parts of the equipment shall be fittedby suitably trained personnel in accordance with themanufacturer's documentation.Manufactured by:Emerson Process ManagementEl-O-Matic B.V.Asveldweg 17556 BT Hengelo (Ov.)The Netherl<strong>and</strong>sDOC.SVM.1 Rev: A 5March ‘04