13.07.2015 Views

CO2 fertilizer system Exclusive DeLuxe - Dennerle

CO2 fertilizer system Exclusive DeLuxe - Dennerle

CO2 fertilizer system Exclusive DeLuxe - Dennerle

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

47484950517.3.2 Cleaning the CO 2 Maxi-Flipper• Take CO 2 Maxi-Flipper out of theaquarium.• Extract CO 2 collector vertically. 47• Place CO 2 Maxi-Flipper into your lefthand, so that the suction cups pointtowards the right. The open side (whichholds the collector) points upwards.• Slide front side wall of the Maxi-Flipperupward by approx. 2 cm. 48• Remove the side wall. 49• Remove the CO 2 tube, do not pull it out.• Now clean all components of the CO 2Maxi-Flipper with warm water and a softsponge. Do not use any detergents.• Reassemble the Maxi-Flipper in reverseorder.Attention: reinsert the CO 2 tube into theside wall so that the lower end is at thevery bottom of the reactor. 507.4 Note on the CO 2 hoseThe special Softflex <strong>CO2</strong> hose is self-sealingand self-locking for maximum safety.Always lever off the hose carefully with ascrewdriver, DO NOT pull off! 51TIP: Large quantities of valuable CO 2 maybe lost every day through leaking CO 2hoses. To avoid this, always use suitableCO 2 hoses, such as thespecial Softflex CO 2 hose fromDENNERLE.7.5 pH-Controller7.5.1 Replacing the fuseIf the connected solenoid valve does not open although the LED indicatesthat the valve is on, either the solenoid valve or the fuse is defective.• Checking the fuse: Connect a normal table lamp (max. 40 W) to thesocket on the power unit. Select a sufficiently low setting to ensurethat the solenoid valve is switched on. If the lamp does not light up,the fuse is defective.• Replacing the fuse: Disconnect the pH-Controller from the power supply.Unscrew fuse holder and remove defective fuse. Fit new fuse ofthe same type (from electrical retailer) and screw fuse holder backinto place.7.5.2 What will happen in case of a power failure?In case of a power failure, all programmed settings and functions will beretained in the internal permanent memory. As soon as the power supplyto the pH-Controller is resumed, it will automatically perform the necessarycontrol actions to restore the pH level in the aquarium to the setvalue.7.6 Cleaning the surfacesUse a moist cloth and a mild detergent. Do not use any aggressive detergentsor solvents!8 What if ... Troubleshooting8.1 CO 2 <strong>fertilizer</strong> <strong>system</strong>FaultA faint hissing sound isto be heard at the screwedconnection betweenpressure reducerand <strong>CO2</strong> cylinder.No bubbles on theMaxi-FlipperCO 2 bubbles issue fromthe hose but do notrise, or do not rise anyfurther after the firststep.Bubbles bob around inthe water, but do notrise.Gas escapes from theside of the Maxi-Flipper’s collector.CO 2 bubbles no longerrise unhindered on thesteps of the Maxi-Flipper.CausePressure reducer isskew or has not beenscrewed in tightenough.Washer in the connectionsocket of the pressurereducer is defective.CO 2 cylinder empty.Needle valve closed.Hose connection leaking.Operating pressure toolowMaxi-Flipper is not fittedin an upright position.Maxi-Flipper is still inthe running-in phase.Water is too agitated.Maxi-Flipper is not fittedin an upright position.Waste air vent on theCO 2 collector is dirty.CO 2 collector is skew.Algae formation, smallsnails or accumulationof sludge in Maxi-FlipperRemedyUnscrew pressure reducerand screw back inplace without canting.Screw finger-tight.Fit new washer (seeabove).Replace CO 2 cylinder.Open needle valve.Check hose connection,replace if necessary.Set operating pressureto approx. 1 bar.Fit Maxi-Flipper in anupright position.Await end of runninginphase.Restrict movement ofthe water or fit Maxi-Flipper at a calmerpoint.Fit Maxi-Flipper in anupright position.Clean Maxi-Flipper.Remove collector andrefit correctly.Clean Maxi-Flipper.FaultThe pH value in theaquarium does notattain the set levelCauseCO 2 supply rate too low8.2 CO 2 night cut-off valveFaultA faint hissing sound isto be heard at the hoseconnector of the nightcut-off valve or thecheck valveIndicator lamp is ON,but no CO 2 supplyIndicator lamp is OFF,but CO 2 is supplied tothe aquarium8.3 pH-ControllerFaultCalibration not possible,or "Err" appearson displayCauseHose connection leakingCO 2 cylinder emptyCylinder valve or needlevalve on pressurereducer closedSolenoid valve jammedSolenoid valve jammedor indicator lampdefectiveCauseThe electrode is in pH7 (pH 4) calibrationsolution, but you havepressed the "pH 4"("pH 7") key.Calibrating solutionsare contaminated/too oldpH-electrode soiledpH-electrode wornout or defectiveRemedyIncrease number of CO 2bubbles step-by-step by5 bubbles per 100 l ofaquarium waterRemedyCut approx. 2 cm off theend of the hose, ensuringthat the cut is straight,slide hose onto connectoras far as it will go andsecure with coupling ring.Replace CO 2 cylinderOpen cylinder valve orneedle valveSend night cut-offvalve in to CustomerService departmentSend night cut-offvalve in to CustomerService departmentRemedyRepeat calibrationprocedure, beginningwith pH 7Use fresh calibratingsolutions, repeat calibrationClean pH-electrodeConnect new pH-electrodeand calibrate;carry out additionalcalibration after 1weekFault"F 01" appears ondisplayNo supply of CO 2 , althoughindicator lampfor CO 2 supply is ONDisplay blankCauseElectrode cable notconnected properlyElectrode cable defectiveMeasured value outsideof measuringrangeProblem with CO 2supplySolenoid valve notconnected properly ordefectiveFuse defectiveConnecting lead notconnectedController defectiveRemedyCheck connectionReplace electrodeCheck CO 2 <strong>system</strong>(e.g. cylinder empty?Needle valve closed?Hose connection leaking?)Check connection,replace solenoidvalve if necessarySee Point 7.5.1Connect connectinglead properly andsecure with lockingscrewsSend controller in toDENNERLE after-salesservice for inspection50 51

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!