ILLUSTRATION OF A CONNECTION<br />

Recessed light 1 Recessed light 2<br />

Cable gland IP68<br />

Recessed box<br />

Layer of gravel<br />

(minimum 30cm)<br />

H07RN-F cable<br />

(or equivalent)<br />

Regulatory<br />

cable*<br />

(in sheath)<br />

Junction box<br />

Resin<br />

Electrical network<br />

* see national regulations.<br />

THE CABLE<br />

To ensure the tightness of the connection, with waterproof connectors or junction box, use a flexible rubber power cable type H07RN-F<br />

or equivalent. A flexible, rubber cable is much easier to seal off against water. When the swivel of the ground spot is fastened to the<br />

cable, the rubber cable sheath will function as a grommet. Nowadays, the cable will often be already attached to the ground spot. In<br />

this case, you don’t need a separate cable.<br />

Caution: if there’s a cable attached to the ground spot, don’t remove it! By doing this, you’ll lose your warranty.<br />

THE DEPTH OF THE ELECTRICAL SHEATH<br />

First of all, it is necessary to refer to national regulations.<br />

Here is what we recommend:<br />

- For an area not accessible to cars:<br />

The electrical conduits must be buried at a minimum depth of 50 cm.<br />

- For an area accessible to cars or under the sidewalks:<br />

Electrical conduits must be buried to a minimum depth of 80 cm.<br />

The buried electrical circuits must circulate in a sheath that can withstand shocks and crushing.<br />

When covering these sheaths, it will be necessary to use soil or sand.<br />

Under no circumstances should heavy stones be used to degrade the buried electric sheath with settlement.<br />

INTEGRATION IN A WOOD FLOOR OR TERRACE<br />

The drilling of the wood blades will be at the recommended drilling diameter (see product sheet, manual, etc ...). The depth under the<br />

floor must al<strong>low</strong> to embed the spot and the waterproof connections. It is also necessary to ensure that there is sufficient space under<br />

the recess to prevent stagnation of the water and not to «bend» the cable just at the exit of the cable gland. Otherwise, drainage will<br />

be done.<br />