12<br />

230 kcal/h<br />

Modello<br />

Model<br />

Модель<br />

SLIM A1<br />

SLIM A2<br />

SLIM A3<br />

SLIM A4<br />

SLIM A5<br />

SLIM S1<br />

SLIM S2<br />

SLIM S3<br />

SLIM S4<br />

SLIM S5<br />

SLIM M1<br />

SLIM M2<br />

SLIM M3<br />

SLIM M4<br />

SLIM M5<br />

Resa (1) / Capacity / Мощность<br />

ΔTi = 10°K SC1<br />

- ккал/ч kW - КВт<br />

1640 1,9<br />

3280 3,8<br />

4910 5,7<br />

6550 7,6<br />

8190 9,5<br />

1340 1,6<br />

2670 3,1<br />

4000 4,7<br />

5340 6,2<br />

6670 7,8<br />

1150 1,3<br />

2300 2,7<br />

3450 4,0<br />

4590 5,3<br />

5740 6,7<br />

Prestazioni<br />

(1) Resa ΔTi = 10°K (indica la differenza<br />

tra la temperatura ingresso dell’aria<br />

all’apparecchio e la temperatura di evaporazione)<br />

La potenza di scambio termico in queste<br />

condizioni è stata ricavata con<br />

R404A, temperatura di evaporazione<br />

0°C, temperatura ambiente cella<br />

+10°C e UR=85%, condizioni corrispondenti<br />

allo standard “SC1” secondo<br />

ENV 328.<br />

(2) Resa ΔTi = 8°K (indica la differenza<br />

tra la temperatura ingresso dell’aria<br />

all’apparecchio e la temperatura di evaporazione)<br />

La potenza di scambio termico in queste<br />

condizioni è stata ricavata con<br />

R404A , temperatura di evaporazione -<br />

8°C, temperatura ingresso dell’aria<br />

0°C e UR=85%, condizioni corrispondenti<br />

allo standard “SC2” secondo<br />

ENV 328.<br />

Resa (2) / Capacity / Мощность<br />

ΔTi = 8°K SC2<br />

Portata aria<br />

Airflow / Расход воздуха<br />

Freccia aria<br />

Air throw / Длина струи<br />

Superficie<br />

Surface / Площадь<br />

kcal/h - ккал/ч kW - КВт m 3 /h - m 3 /ч m m 2<br />

1120 1,3<br />

2240 2,6<br />

3350 3,9<br />

4470 5,2<br />

5580 6,5<br />

910 1,1<br />

1820 2,1<br />

2730 3,2<br />

3640 4,2<br />

4550 5,3<br />

790 0,9<br />

1570 1,8<br />

2350 2,7<br />

3130 3,6<br />

3910 4,5<br />

Modello<br />

Model<br />

Модель<br />

Motoventilatori<br />

Fan motors / Моторы вентиляторов<br />

kcal/h RPM kW Assorbimento<br />

N x Ø 230<br />

Amps 230V (A)<br />

ОБ/МИН Ток при 230В (A)<br />

SLIM-1 1 1300 0,48 0,08<br />

SLIM-2 2 1300 0,96 0,16<br />

SLIM-3 3 1300 1,44 0,24<br />

SLIM-4 4 1300 1,92 0,32<br />

SLIM-5 5 1300 2,40 0,40<br />

700<br />

1400<br />

2100<br />

2800<br />

3500<br />

720<br />

1460<br />

2190<br />

2920<br />

3650<br />

750<br />

1500<br />

2250<br />

3000<br />

3750<br />

Capacity<br />

(1) Capacity ΔTi = 10° K (ΔTi indicates<br />

the difference between the air inlet<br />

temperature and the evaporating temperature).<br />

The capacity of the aircooler<br />

is calculate with freon R404A, evaporating<br />

temperature 0°C, room temperature<br />

+10°C RH=85%, conditions<br />

related to standard “SC1” in accordance<br />

with ENV 328.<br />

(2) Capacity ΔTi = 8° K (ΔTi indicates<br />

the difference between the air inlet<br />

temperature and the evaporating temperature).<br />

The capacity of the aircooler<br />

is calculated with R404A, evaporating<br />

temperature –8°C, inlet air temperature<br />

0°C RH=85%, conditions related<br />

to standard “SC2” in accordance<br />

with ENV 328.<br />

Potenza assorbita<br />

Absorbed power (kW)<br />

Мощность (кВт)<br />

3,3<br />

4,6<br />

5,2<br />

6,6<br />

7,1<br />

3,5<br />

4,9<br />

6,0<br />

6,7<br />

7,3<br />

3,6<br />

5,2<br />

6,3<br />

7,2<br />

7,6<br />

Sbrinamento / Defrost system<br />

Система оттайки<br />

Elettrico - Electric (kW)<br />

Электрическая (кВт)<br />

1,0<br />

1,8<br />

2,6<br />

3,3<br />

4,2<br />

5,7<br />

11,4<br />

17,1<br />

22,8<br />

28,5<br />

4,2<br />

8,4<br />

12,6<br />

16,8<br />

21,0<br />

3,3<br />

6,6<br />

9,9<br />

13,2<br />

16,5<br />

Мощность<br />

(1) Мощность ΔTi = 10° K (ΔTi<br />

Показывает разницу между температурой<br />

входящего воздуха и температурой<br />

испарения). Мощность воздухоохладителя<br />

рассчитывается при следующих<br />

параметрах: фреон R404A, температура<br />

испарения 0° С, емпература в помещении<br />

+10° С. Отн. влажность (RH) =<br />

85%.Указанные условия относятся к<br />

стандарту «SC1» в соответствии с европейским<br />

нормативом ENV 328.<br />

(2) Мощность ΔTi = 8° K (ΔTi<br />

Показывает разницу между температурой<br />

входящего воздуха и температурой<br />

испарения). Мощность воздухоохладителя<br />

рассчитывается при следующих параметрах:<br />

фреон R404A, температурой<br />

испарения -8° С, температура в помещении<br />

0° С. Отн. влажность (RH) = 85%.<br />

Указанные условия относятся к стандарту<br />

«SC2» в соответствии с европейским<br />

нормативом ENV 328.<br />

Volume int. batteria<br />

Coil capacity<br />

Объём трубки<br />

теплообменника<br />

(dm3 - дм3 )<br />

1,5<br />

3,2<br />

4,7<br />

6,2<br />

7,7