the following measures should be taken:<br />
During storage, the powered pallet truck should be raised to keep the wheels apart from ground completely. In this<br />
case, the wheels and bearings inside wheels are protected from damage.<br />
In case of storage duration of the truck over 6 months, please contact the maintenance service of the<br />
manufacture for other ad<strong>di</strong>tional measures.<br />
5.5.1 Operations to be done before storage<br />
Clean the powered pallet truck thoroughly<br />
Check the braking function<br />
Check the hydraulic oil capacity, feed it up if necessary<br />
Apply oil or grease to all parts for protection<br />
Consult detailed Lubrication List to feed lubrication to the truck<br />
Recharge the battery<br />
Cut off and clean the battery and apply grease to battery electrodes<br />
Besides the above, the instructions provided by the battery supplier are also to be observed.<br />
5.5.2 Measures to be taken during storage<br />
Every two months: charge the battery<br />
Operation of battery of the powered pallet truck:<br />
It is important to recharge the battery regularly. Otherwise, complete consumption of battery will cause<br />
automatic <strong>di</strong>scharge and even damage the battery.<br />
5.5.3 Re-commissioning<br />
Clean the powered pallet truck thoroughly<br />
Consult detailed Lubrication List to feed lubrication to the truck<br />
Clean the battery, apply grease to electrode bolt and connect the battery<br />
Recharge the battery<br />
Check if any moisture in the gear oil, replace it if required<br />
Check if any moisture in the hydraulic oil, replace it if required<br />
Start the pallet truck<br />
Operation of battery of the pallet truck<br />
In case of fault of the electrical system, brush all exposed electrical connections with contact cleaner.<br />
Repeat this step to eliminate the oxide layer on the connecting parts of the operating controller.<br />
Electromagnetic braking test should be imme<strong>di</strong>ately performed after re-commissioning.<br />
5.5.4 Faults Diagnosis<br />
In this section, we will introduce how to find out and handle some of the simple faults to the user as<br />
specified in the following sheet:<br />
mettere pag 16 17 18 19 wwp<br />
Le pag. 20-23a seconda del modello del commissionatore .<br />
Es wp10-20= enzo 20<br />
If there is any fault can not be eliminated through the above treatment, please notify the after-sales service of the<br />
manufacturer for trained professionals’ <strong>di</strong>sposal.<br />