<strong>TGB</strong>-<strong>40</strong>/<strong>60</strong> Maintenance instructions<br />
Safety instructions<br />
Carry out the following steps before carrying out any<br />
maintenance work.<br />
• Switch OFF the system ON/OFF switch on the Wolf gas<br />
fired boiler.<br />
The mains terminals are ‘live‘ even when the<br />
ON/OFF switch has been switched OFF.<br />
• Switch OFF the emergency stop switch (or remove<br />
fuses).<br />
ON/OFF switch<br />
Control unit overview<br />
• Close the gas shut-off valve.<br />
• Close the shut-off valves on the heating flow and<br />
return, and drain the water from the boiler.<br />
• Remove the front panel and protect it from damage.<br />
Risk of burns<br />
Several components may be hot. Let these cool down or<br />
wear gloves.<br />
Dismantling the combustion chamber unit<br />
2 x top toggles<br />
• Remove the combustion chamber housing after releasing<br />
the toggles.<br />
Combustion chamber casing 2 x bottom toggles<br />
Gas fired condensing boiler with front casing removed<br />
39