14.02.2014 Views

TGB-40/60 Wartungsanleitung

TGB-40/60 Wartungsanleitung

TGB-40/60 Wartungsanleitung

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>TGB</strong>-<strong>40</strong>/<strong>60</strong> Maintenance instructions<br />

• Remove the plug connections from the following<br />

components: ignition, ionisation, earth, flow and return<br />

temperature sensor, flue gas temperature sensor and gas<br />

fan.<br />

Remove the hose from the mixing chamber.<br />

Gas fan plug<br />

Mixing chamber<br />

Flow sensor<br />

plug<br />

Flue gas<br />

sensor plug<br />

Ignition plug<br />

Ionisation plug<br />

Earth plug<br />

Return<br />

sensor plug<br />

Gas fired condensing boiler with combustion chamber<br />

housing removed<br />

• Pull the anti-radiation panel forward and unhook the<br />

panel.<br />

Anti-radiation panel<br />

Location of anti-radiation panel<br />

• Release the joint between the gas connection and the<br />

mixing chamber.<br />

Joint between the gas connection and mixing chamber<br />

Location of joint<br />

• Release the nuts (3 no.) on the burner flange.<br />

• Remove the whole assembly (mixing chamber, fan and<br />

burner flange).<br />

Nut on the burner flange<br />

<strong>40</strong><br />

Location of nut on the burner flange