11.07.2015 Views

MD10V 14/18 - Federal Fluid Power, Inc.

MD10V 14/18 - Federal Fluid Power, Inc.

MD10V 14/18 - Federal Fluid Power, Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

R1 2 3 4 5 6 7 7A 8 9 10 11 12 13 <strong>14</strong> 1511 - FILTRO / FILTER00FIFE00Senza FiltroWithout FilterCon FiltroWith FilterFiltro con sensore elettricoFilter with Electric sensor12 - PREDISPOSIZIONI / THROUGH DRIVENessuna PredisposizioneWithout through driveSTANDARDESTREMITÀ ALBERO / SHAFT END06 09 08 07● / ● ●SA SAE A = Z9 - 16/32 DP ● / ● ●SB SAE B = Z13 16/32 DP / ● / /TAPredisposizione Tandem per assemblaggio mediante SAE A = Z9 - 16/32 DPPump combination c/w through drive SAE A = 9T - 16/32 DP● / ● /TBPredisposizione Tandem per assemblaggio mediante SAE B = Z13 16/32 DPPump combination c/w through drive SAE B = 13T 16/32 DP/ ● / /TSTandem (Versione Corta) assemblataPump combination (Short Version)/ ● / /● Disponibile - Available/ Non Disponibile - Not Available13 - LIMITAZIONE CILINDRATA RAMO A / DISPLACEMENT LIMITATION SIDE AXX00÷27Non RichiestaNot RequiredDa 0 cm 3 /giro a 27 cm 3 /giroFrom 0 cm 3 /giro To 27 cm 3 /giro<strong>14</strong> - LIMITAZIONE CILINDRATA RAMO B / DISPLACEMENT LIMITATION SIDE BXX00÷2700Non RichiestaNot RequiredDa 0 cm 3 /giro a 27 cm 3 /giroFrom 0 cm 3 /giro To 27 cm 3 /giro15 - OPZIONI / OPTIONSNessuna OpzioneWithout OptionREGOLATORE / CONTROLHIN HIR HLR HE2 HER HEI● ● ● ● ● ●01 By pass ● ● ● ● ● ●0205Limitatore di potenza (annullamento a 270 bar)<strong>Power</strong> limiter [destroke at 3915 psi]Attacchi supplementari manometroAdditional control pressure gauge portsContattare Servizio TecnicoContact Technical Department● ● ● ● ● ●● ● ● ● ● ●By pass + Attacchi supplementari manometroAH ● ● ● ● ● ●By pass + Additional control pressure gauge portsAAADAEAIALLimitatore di potenza (annullamento a 270 bar) + By pass<strong>Power</strong> limiter [destroke at 3915 psi] + By passValvola Taglio Elettrico 12VElectric Cut-off valve 12VValvola Taglio Elettrico 24VElectric Cut-off valve 24VBy pass + Valvola Taglio Elettrico 12VBy pass + Electric Cut-off valve 12VBy pass + Valvola Taglio Elettrico 24VBy pass + Electric Cut-off valve 24VContattare Servizio TecnicoContact Technical DepartmentNon disponibile con predisposizione TSNot available with TS through driveNon disponibile con predisposizione TSNot available with TS through driveNon disponibile con predisposizione TSNot available with TS through driveNon disponibile con predisposizione TSNot available with TS through drive● ● ● ● ● ●● / ● / / /● / ● / / /● / ● / / /● / ● / / /● Disponibile - Available/ Non Disponibile - Not AvailablePag. C/5axial piston

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!