AARDINGSBOLLEN BOULES DE MISE À LA TERRE<br />

45° angled with threaded pin and self-locking nut / 45° avec tige filetée et un écrou autobloquant<br />

Type 20 W45 M12 35SSM 20 W45 M16 45SSM 25 W45 M12 45SSM 25 W45 M16 45SSM<br />

Code 7<strong>06</strong> 235 7<strong>06</strong> 645 756 245 756 645<br />

Fixed ball point / Points fixe sphérique Ø 20 mm 20 mm 25 mm 25 mm<br />

Dimensions M12 x 35 mm M16 x 45 mm M12 x 45 mm M16 x 45 mm<br />

Width A/F / Largeur A/F 24 mm 24 mm 27 mm 27 mm<br />

Max. cable cross-section / Section max. 70 mm² 70 mm² 95 mm² 95 mm²<br />

Max. short-circuit current / I k 0.5 s 19.5 kA 19.5 kA 26.5 kA 26.5 kA<br />

Courant de court-circuit max. I k 1 s 13.8 kA 13.8 kA 18.7 kA 18.7 kA<br />

45° angled with female thread / 45° avec filetage intérieur<br />

Type 20 W45 M12 20 W45 M16 25 W45 M12 25 W45 M16<br />

Code 7<strong>06</strong> 200 7<strong>06</strong> 600 756 200 756 600<br />

Fixed ball point / Points fixe sphérique Ø 20 mm 20 mm 25 mm 25 mm<br />

Dimensions M12 mm M16 mm M12 mm M16 mm<br />

Width A/F / Largeur A/F 24 mm 24 mm 27 mm 27 mm<br />

Max. cable cross-section / Section max. 70 mm² 70 mm² 95 mm² 95 mm²<br />

Max. short-circuit current / I k 0.5 s 19.5 kA 19.5 kA 26.5 kA 26.5 kA<br />

Courant de court-circuit max. I k 1 s 13.8 kA 13.8 kA 18.7 kA 18.7 kA<br />

EAPA<br />

EARTH CONNECTING PLATES<br />

PLAQUES DE MISE À LA TERRE<br />

• In accordance with EN/IEC 61230 (DIN VDE <strong>06</strong>83-100).<br />

• For indoor and outdoor installations.<br />

• High short-circuit current carrying capacity.<br />

• Conforme à la norme EN/IEC 61230 (DIN VDE <strong>06</strong>83-100).<br />

• Pour utilisation en intérieur comme en extérieur.<br />

• Haute capacité de transport de courant de court-circuit.<br />

With three fixed ball points and ball head cap / Avec trois points fixes et tête sphérique<br />

Type EAPA 3 KFP 20 KKH EAPA 3 KFP 25 KKH<br />

Code 728 620 728 625<br />

Fixed ball point / Points fixe sphérique Ø 20 mm 25 mm<br />

Max. cable cross-section / Section max. 120 mm² 150 mm²<br />

Max. short-circuit current / I k 0.5 s 33.5 kA 42.0 kA<br />

Courant de court-circuit max. I k 1 s 23.7 kA 29.6 kA<br />

With three fixed ball points / Avec trois points fixes<br />

Type EAPA 3 KFP 20 B13 EAPA 3 KFP 25 B13<br />

Code 728 522 728 526<br />

Fixed ball point / Points fixe sphérique Ø 20 mm 25 mm<br />

Max. cable cross-section / Section max. 120 mm 150 mm²<br />

Max. short-circuit current / I k 0.5 s 33.5 kA 42.0 kA<br />

Courant de court-circuit max. I k 1 s 23.7 kA 29.6 kA<br />