3.2.5. Type and number of samples<br />
The types and number of samples are summarized in the Table 3.<br />
Table 3 Number of samples for analysis of mineral oil<br />
Test<br />
day<br />
No.:<br />
Samples before filter<br />
Aerosol on<br />
plane filter<br />
Oil vapour on<br />
XAD-2<br />
Aerosol on<br />
plane filter<br />
Samples after filter<br />
Oil vapour on<br />
XAD-2<br />
2 3 2 3 2<br />
12 3 2 3 2<br />
Total 6 4 6 4<br />
Samples on filters and XAD-2 will be analysed and reported separately.<br />
3.2.6. Operation conditions<br />
The operation conditions applied during the verification of the product are:<br />
Operation parameters for the aerosol generator: Air pressure, temperature in the oil<br />
mist generator block, nozzle used (No. 1, 2 or 3).<br />
Operation parameters for the filter: Air flow and air temperature.<br />
Sampling conditions: Sampling in the centre of the duct, according to the<br />
requirements for sampling in the Danish Air guideline /2/.<br />
Each sampling campaign for mineral oils will consist of three one hour samples,<br />
according to the requirements for sampling in the Danish Air guideline /2/.<br />
3.2.7. Operation measurements<br />
During operation, the following operation conditions are recorded:<br />
• Flow<br />
• Inlet air temperature<br />
• Outlet air temperature<br />
• Pressure air pressure<br />
The data is stored in a data logging devise as 5 minutes average values.<br />
The following operation parameters are measured for the whole test period:<br />
• Total operating time<br />
• Oil consumption in aerosol generator<br />
• Oil separated regained from the filter<br />
• Weight increase of the pre-filter and the polishing filter<br />
See Appendix A for sampling and measurement methods.<br />