Inntaksmåte A<br />

Tabell A<br />

Tabell for valg av vern/kabel IT, TT, TN-S<br />

1 2 3<br />

Tariff Kortslutn.vern Overbelastningsvern<br />

(Ved TN-S Skjult Åpent TN-S TT/IT<br />

2/...=1+N A1 A2 C<br />

Ik3 pol maks ≤ 6kA (* maks 10 kA) Ik3 pol maks ≤ 10kA<br />

3/...=3+N Lederstørrelse mm 2<br />

PN Ik min > 0,5kA opp til 63A Ik min> 0,5kA opp til 63A<br />

Kabel Kabel<br />

Ant.faser/A Type Cu Cu Al Cu Al Type Type<br />

2/25A 6 6 25 6 25 PLSM-OV25/1N PLSM-OV25/2<br />

3/25A 6 6 25 6 25 PLSM-OV25/4 PLSM-OV25/3<br />

2/32A 6 6 25 6 25 PLSM-OV32/1N PLSM-OV32/2<br />

3/32A 10 10 25 6 25 PLSM-OV32/4 PLSM-OV32/3<br />

2/40A Kombinert m/ 10 10 25 6 25 PLSM-OV40/1N PLSM-OV40/2<br />

3/40A<br />

overbelastningsvern<br />

10 16 25 6 25 PLSM-OV40/4 PLSM-OV40/3<br />

2/50A 16 16 25 10 25 PLSM-OV50/1N PLSM-OV50/2<br />

41<br />

3/50A 16 16 25 10 25 PLSM-OV50/4 PLSM-OV50/3<br />

2/56A 16 16 25 10 25 PLSM-OV56/1N PLSM-OV56/2<br />

3/56A 16 25 35 10 25 PLSM-OV56/4 PLSM-OV56/3<br />

2/63A 25 25 35 10 25 PLSM-OV63/1N PLSM-OV63/2<br />

3/63A 25 25 35 16 25 PLSM-OV63/4 PLSM-OV63/3<br />

Anbefaler FEBDOK beregning over 63A<br />

Selektivitetsnivå mellom kV og OV se tabell side 47