31.07.2013 Views

Manual unitate de control ProControl - AQUAmax

Manual unitate de control ProControl - AQUAmax

Manual unitate de control ProControl - AQUAmax

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

proControl ©<br />

Unitate <strong>de</strong> <strong>control</strong> pentru <strong>AQUAmax</strong> ® BASIC/CLASSIC si PROFESSIONAL<br />

G/XL<br />

Instructiune <strong>de</strong> conectare si utilizare<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

1 / 42


INDEX<br />

Observatii generale si <strong>de</strong> siguranta 3<br />

Caracteristici ale echipamentului 3<br />

Montaj 4<br />

Principiul <strong>de</strong> functionare 6<br />

CLASSIC / BASIC 5<br />

PROFESSIONAL 6<br />

Functionare in cazul inundatilor 8 (doar Professional XL) 7<br />

Plutitorul 8<br />

Generalitati 8<br />

Utilizare 9<br />

Prima punere in functiune 9<br />

Indicarea statutului <strong>de</strong> functionare 11<br />

Nivel 1./2. 12<br />

Info 12<br />

Service info 13<br />

Data/ora 13<br />

Contor ore <strong>de</strong> operare 13<br />

Mod <strong>de</strong> operare manual 13<br />

Jurnal <strong>de</strong> functionare 14<br />

Setari 15<br />

Amperaj, valori limita 15<br />

Modul <strong>de</strong> service 16<br />

Resetarea <strong>de</strong>ranjamentelor 16<br />

Modul <strong>de</strong> service 17<br />

Service 18<br />

Setare limba 19<br />

Locuitori racordati 19<br />

Seria 19<br />

Testul agregatelor 19<br />

Lista <strong>de</strong>ranjamente 20<br />

Setari 21<br />

Amperaj, valori limita 24<br />

Extin<strong>de</strong>re 24<br />

Setari din fabrica 25<br />

Perioada <strong>de</strong> adaptare 26<br />

Precipitare fosfor 26<br />

Pompa dozaj 26<br />

Dezinfectare - UV 27<br />

Contactul fara potential 27<br />

Anexe 28<br />

Prezentarea timpilor preinstalati si a valorilor limita 28<br />

Semnalizarea <strong>de</strong>ranjamentelor 30<br />

Date tehnice 35<br />

Semnalizarea aprofundata a <strong>de</strong>ranjamentelor 36<br />

Declaratia <strong>de</strong> conformitate 38<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

2 / 42


Stimate client,<br />

va multumim pentru incre<strong>de</strong>rea acordata prin cumpararea acestui produs.<br />

Va rugam sa va luati cateva minute pentru a citi cu atentie aceste instructiuni <strong>de</strong> utilizare.<br />

Doar in acest fel se poate asigura o functionare sigura si fara <strong>de</strong>ranjamente a instalatiei!<br />

Observatii generale si <strong>de</strong> siguranta<br />

Unitatea <strong>de</strong> <strong>control</strong> proControl © serveste dirijarii instalatiilor <strong>de</strong> epurare SBR <strong>de</strong> tipul<br />

<strong>AQUAmax</strong> ® .<br />

proControl © este recomandata pentru racordarea a pana la doua aeratoare, doua<br />

pompe <strong>de</strong> alimentare, si doua pompe <strong>de</strong> evacuare, o pompa pentru namol, un mixer<br />

cat si patru plutitoare pentru semnalizarea nivelului.<br />

Nu exista nici un pericol provenit <strong>de</strong> la statia <strong>de</strong> epurare in cazul uitilizarii<br />

corespunzatoare. A se respecta regulile national valabile cat si datele tehnice!<br />

Daca proControl © se utilizeaza in alte scopuri <strong>de</strong>cat cele mentionate, fara aprobarea<br />

specifica a firmei ATB Umwelttechnologien GmbH si/sau nu sunt respectate<br />

instructiunile <strong>de</strong> siguranta atunci urmarea este <strong>de</strong>fectarea sau functionarea<br />

necorespunzatoare a statiei. In acest caz este exclusa orice garantie.<br />

Modificarile aparatului nu sunt admise si conduc la pier<strong>de</strong>rea pretentiilor <strong>de</strong> garantie.<br />

Nu utilizati nici un aparat care indica <strong>de</strong>ranjamente, care a cazut sau care a fost<br />

<strong>de</strong>teriorate intr-un fel.<br />

Explicatia semnelor <strong>de</strong> prevenire utilizate:<br />

Atentie! Pericol <strong>de</strong> inalta tensiune!<br />

Caracteristici ale echipamentului<br />

• Condusa <strong>de</strong> un microprocesor.<br />

• Folie <strong>de</strong> protectie. Conditionat indicata pentru spatii exterioare (IP65).<br />

• Montaj pe perete<br />

• Sesizare ca<strong>de</strong>re tensiune (UVS)<br />

• Contact fara potential pentru un echipament <strong>de</strong> alarma aditional si<br />

pentru activarea unei pompe <strong>de</strong> dozare pentru eliminare fosfor sau a unei unitati –<br />

UV - pentru igienizare<br />

• Jurnal <strong>de</strong> functionare complex<br />

• Utilizare simpla si rapida<br />

• Timpii pentru toate capacitatile sunt presetati complet<br />

• Perioada <strong>de</strong> adaptare automata in care nu este evacuat namolul in exces<br />

• Setarile parametriilor se pot alege liber<br />

• 4 limbaje la alegere pentru setarea meniului (germana, engleza, franceza,<br />

spaniola)<br />

• Se poate utiliza pentru <strong>AQUAmax</strong>® CLASSIC, BASIC si PROFESSIONAL<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

3 / 42


Montaj<br />

Fixati <strong>unitate</strong>a proControl © <strong>de</strong> unghiul special prevazut al carcasei, cu materialul <strong>de</strong><br />

prin<strong>de</strong>re livrat, intr-un loc <strong>de</strong> preferinta ferit <strong>de</strong> intemperii.<br />

In cazul unei temperaturi sub 0°C este <strong>de</strong> asteptat ca functionalitate display-ului LC sa<br />

fie puternic redusa.<br />

proControl® pentru variantele CLASSIC; BASIC si PROFESSIONAL G se livreaza gata<br />

precablate. Cablarea pe santier nu mai este necesara.<br />

proControl © pentru statiile PROFESSIONAL XL sunt livrate gata precablate cu un dulap<br />

<strong>de</strong> record separat pe o placa <strong>de</strong> montaj comuna. Deschi<strong>de</strong>rea unitatii <strong>de</strong> <strong>control</strong> nu mai<br />

este necesara!<br />

Un plan <strong>de</strong> racordare corespunzator este livrat aditional.<br />

Toate lucrarile care necesita totusi <strong>de</strong>schi<strong>de</strong>rea unitatii <strong>de</strong> <strong>control</strong> ca si racordurile<br />

electrice ale unei PROFESSIONAL XL trebuie efectuate <strong>de</strong> un electrician specialist!<br />

ATENTIE! Inainte <strong>de</strong> a <strong>de</strong>schi<strong>de</strong> <strong>unitate</strong>a proControl © si/sau dulapul <strong>de</strong><br />

racorduri trebuie intrerupt curentul electric. Lucrarile la un aparat<br />

<strong>de</strong>schis sunt efectuate doar <strong>de</strong> personal calificat! A se tine cont <strong>de</strong> un<br />

racord fazic corect. (chiar si la variantele precablate din fabrica)!<br />

Datorita faptului ca este vorba <strong>de</strong> o statie electrica cu pompe<br />

submersibile trebuie prevazuta neaparat o siguranta B16 separata si un<br />

(posibil tot separat) intrerupator diferential FI- 30 mA!<br />

Trebuie tinut cont <strong>de</strong> pozitionarea corespunzatoare a legaturilor <strong>de</strong><br />

siguranta pana la impamantarea cladirii.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

4 / 42<br />

Folie <strong>de</strong> protectie, IP 65<br />

Display cu patru randuri,<br />

luminat<br />

4 taste, tip Softkeys<br />

Soclu separat pentru racorduri,<br />

230 V, sigurante incluse<br />

Stecher rotund <strong>de</strong> legatura :<br />

Galben = bazin tampon<br />

Albastru = agregate SBR<br />

Negru = plutitori SBR<br />

(la BASIC si la CLASSIC cu ajutorul<br />

unui adaptor)


Principiul <strong>de</strong> functionare<br />

proControl © este conceputa pentru statii <strong>de</strong> epurare, care functioneaza conform<br />

principiului SBR.<br />

Aici are loc tratarea biologica, separarea namolului si evacuarea apelor epurate in unul<br />

si acelasi bazin. Apa menajera este tratata in sarje (ciclic) fiecare etapa <strong>de</strong> tratare<br />

urmand cronologic si nu in diferite bazine. Variatii <strong>de</strong> concentratie si <strong>de</strong>bit nu<br />

influenteaza calitatea epurarii apei.<br />

Un ciclu este format din<br />

1. Umplere<br />

}<br />

2. Denitrificare Faza <strong>de</strong> epurare (Faza <strong>de</strong> aerare)<br />

3. Nitrificare / eliminare carbon<br />

4. Evacuare namol in exces (nu la XL)<br />

5. Sedimentare<br />

6. Evacuare ape epurate<br />

7. Evacuare namol in exces (doar XL)<br />

8. Post operare<br />

Inainte <strong>de</strong> faza <strong>de</strong> sedimentare punctele 1.-3. sunt <strong>de</strong> regula parcurse <strong>de</strong> mai multe ori.<br />

(la CLASSIC si la BASIC)<br />

Toti timpii sunt presetati pentru utilizarea standard. D-vs introduceti doar numarul <strong>de</strong><br />

locuitori (PE)!<br />

Functionare BASIC<br />

Apa reziduala intra in bazinul <strong>de</strong> retentie grosier / namol. Aici este retinut respectiv<br />

stocat namolul primar si in unele cazuri si cel secundar. Dupa aceea apa ajunge<br />

gravitational in bazinul tampon.<br />

Apa menajera stocata este transferata in bazinul <strong>de</strong> tratare cu ajutorul principiului<br />

vaselor comunicante si a pompei <strong>de</strong> namol in exces. Aerator submersibil efectueaza<br />

intremitent aerarea si amestecarea.<br />

Dupa faza <strong>de</strong> aerare si sedimentare apa epurata este evacuata cu ajutorul unei pompe<br />

<strong>de</strong> evacuare.<br />

Faza <strong>de</strong> sedimentare se incheie :<br />

a) cu <strong>de</strong>schi<strong>de</strong>rea plutitorului [SW1] din bazinul <strong>de</strong> tratare sau<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

5 / 42


) dupa scurgerea timpului maxim programat pentru evacuare. In acest caz se<br />

activeaza o alarma.<br />

Faza <strong>de</strong> evacuare se poate prelungi (standard cu 25 sec. la echipamentele cu<br />

AQUAswitch [BASIC] iar in alte cazuri cu 0 sec). Dupa aceasta urmeaza o pauza <strong>de</strong> 1<br />

minut in care nici un agregat nu opereaza.<br />

In timpul fazei <strong>de</strong> epurare are loc inlaturarea namolului, etapa omisa in timpul perioa<strong>de</strong>i<br />

<strong>de</strong> adaptare.<br />

Functionare PROFESSIONAL<br />

Apa reziduala intra in bazinul <strong>de</strong> retentie grosier / namol. Aici este retinut respectiv<br />

stocat namolul primar si in unele cazuri si cel secundar. Dupa aceea apa ajunge<br />

gravitational in bazinul tampon.<br />

Ciclul <strong>de</strong> tratare porneste cu umplerea bazinului SBR. La atingerea in bazinul <strong>de</strong><br />

stocare a unui nivel <strong>de</strong> apa suficient (plutitorul <strong>de</strong> jos [SW3] inchis), aceasta este<br />

transportata cu ajutorul pompei <strong>de</strong> umplere in bazinul SBR.<br />

Umplerea se incheie:<br />

a) dupa scurgerea timpului programat<br />

b) cand [SW3] <strong>de</strong>schi<strong>de</strong> (nivelul minim in bazinul <strong>de</strong> stocare) sau<br />

c) volumul maxim in bazinul <strong>de</strong> tratare este atins (Hwmax, plutitorul <strong>de</strong> sus din bazinul<br />

SBR [SW2] inchis)<br />

Daca plutitorul <strong>de</strong> jos [SW1] din bazinul <strong>de</strong> tratare nu este inca inchis la inceputul fazei<br />

<strong>de</strong> sedimentare si / sau nu este suficienta apa in bazinul <strong>de</strong> stocare, atunci instalatia<br />

trece in modul econom <strong>de</strong> operare. In modul econom aerarea este redusa. Acesta se<br />

incheie odata ce plutitorul [SW3] inchi<strong>de</strong>.<br />

Dupa umplere porneste faza <strong>de</strong> <strong>de</strong>nitrificare, careia ii urmeaza faza <strong>de</strong> nitrificare. In<br />

ambele faze (ca si in modul econom <strong>de</strong> operare) aerarea este intermitenta.Toti timpii se<br />

pot seta separat.<br />

Umplerea, <strong>de</strong>nitrificarea si nitrificarea pot fi parcurse <strong>de</strong> mai multe ori consecutiv.<br />

Ultima umplere are loc cel tarziu la doua ore inainte <strong>de</strong> inceperea fazei <strong>de</strong><br />

sedimentare.<br />

Faza <strong>de</strong> sedimentare urmeaza dupa faza <strong>de</strong> tratare aeroba. Namolul sedimenteaza iar<br />

apa epurata este evacuata.<br />

Evacuarea se incheie:<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

6 / 42


a) cu <strong>de</strong>schi<strong>de</strong>rea plutitorului <strong>de</strong> jos [SW1] din bazinul <strong>de</strong> tratare sau<br />

b) dupa scurgerea timpului maxim programat pentru evacuare. In acest caz se<br />

activeaza o alarma.<br />

Dupa evacuarea apei la unitatile PROFESSIONAL G se incheie si ciclul.<br />

La PROFESSIONAL XL urmeaza dupa evacuarea apei epurate si evacuarea namolului<br />

in exces. La PROFESSIONAL G evacuarea namolului in exces are loc in timpul fazei<br />

<strong>de</strong> aerare.<br />

Evacuarea namolului in exces in timpul fazei <strong>de</strong> adaptare este omisa la ambele tipuri.<br />

Dupa aceasta urmeaza o pauza <strong>de</strong> 1 minut in care nici un agregat nu opereaza.<br />

Functionare in cazul inundatilor (doar PROFESSIONAL XL)<br />

In cazul in care statia este alimentata cu atata apa incat volumul <strong>de</strong> utilizare maxim al<br />

bazinultui tampon este <strong>de</strong>pasit (plutitorul <strong>de</strong> sus in bazinul tampon [SW4] inchi<strong>de</strong>), iar<br />

in bazinul SBR mai este disponibila capacitate <strong>de</strong> umplere (plutitorul <strong>de</strong> sus in SBR<br />

[SW2] inca <strong>de</strong>schis), se efectueaza o umplere imediata pana cand:<br />

a) Plutitorul <strong>de</strong> sus in bazinul SBR- [SW2] inchis (urmeaza imediat o sedimentare,<br />

scurtata la jumatate din timpul normal si este indicata o alarma)<br />

b) Timpul <strong>de</strong> umplere standard a expirat (daca dupa aceea plutitorul <strong>de</strong> sus in bazinul<br />

tampon [SW4] se <strong>de</strong>schi<strong>de</strong> continua ciclul normal <strong>de</strong> tratare. In cazul in care mai<br />

este inca inchis dupa o aerare intermediara se umple in continuare)<br />

c) Plutitorul <strong>de</strong> jos din bazinul tampon [SW3] <strong>de</strong>schi<strong>de</strong>.<br />

ATENTIE! In ultimele doua ore inainte <strong>de</strong> faza <strong>de</strong> sedimentare cat si in faza <strong>de</strong> sedimentare<br />

nu se efectueaza NICI o umplere!<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

7 / 42


Plutitorul <strong>de</strong> comutare<br />

Plutitor <strong>de</strong>schis<br />

= 0 in display<br />

(plutitorul este in pozitia <strong>de</strong> jos)<br />

Plutitor inchis<br />

= 1 in display<br />

(plutitorul este in pozitia sus)<br />

ATENTIE! Schimbarea <strong>de</strong> comutare are un sunet tipic. Comutarea are loc <strong>de</strong>stul<br />

<strong>de</strong> tarziu chiar daca optic plutitorul pare sa fie sus sau respectiv jos (unghiul <strong>de</strong><br />

comutare fata <strong>de</strong> suprafata apei +/- 50°).<br />

Atentie la indicatorul <strong>de</strong> statut din display-ul unitatii <strong>de</strong> <strong>control</strong>!<br />

AQUAswitch<br />

In cazul plutitorului AQUAswitch este vorba <strong>de</strong> un comutator cu contact Reed<br />

integrat in conducta <strong>de</strong> aerisire la BASIC. Plutitorul nu este vizibil din exterior.<br />

Statutul <strong>de</strong> comuntare poate fi verificat in modul <strong>de</strong> operare manual.<br />

Generalitati<br />

Manipularea se efectueaza cu ajutorul celor 4 taste, ale caror<br />

functie <strong>de</strong>pin<strong>de</strong> <strong>de</strong> meniul, respectiv submeniul in care va<br />

aflati.<br />

In ultimul rand pe display sunt indicate functiile tastelor in<br />

respectivul meniu. Cel <strong>de</strong>-al doilea rand <strong>de</strong> sus – cel care se<br />

afla intre doua sageti – este randul in care se efectueaza<br />

modificarile. Adica cu ajutorul tastelor cu sageata <strong>de</strong>asupra<br />

se alege submeniul dorit (asemanator numerelor <strong>de</strong> telefon<br />

din agenda unui telefon mobil); cand acesta este intre cele<br />

doua sageti () se confirma cu tasta “OK”.<br />

Functii posibile ale tastelor<br />

-  ↓ Rasfoire meniu sus jos<br />

- Pos Apasand ajungeti cu cursorul in dreptul cifrei pe care dorti sa o modificati.<br />

Cursorul inainteaza doar intr-o singura directie; daca ati trecut <strong>de</strong> cifra dorita<br />

apasati pana ajungeti din nou la pozitia prece<strong>de</strong>nta!<br />

- Value Apasand, rasfoiti cifrele posibile. Adica 0 – 9 sau respectiv zilele Mo – Su.<br />

- OK Prin apasarea tastei respective confirmati modificarea efectuata.<br />

- ESC Prin apasarea tastei ajungeti in meniu un nivel mai sus.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

8 / 42


Prima punere in functiune<br />

La prima punere in functiune se efectueaza reglarile <strong>de</strong> baza si teste. Odata cu introducerea<br />

numarului <strong>de</strong> locuitori ceilalti parametrii importanti vor fi automat presetati. Va recomandam<br />

insa, dupa punerea in functiune, sa mai verificati inca o data, la SETARI, parametrii presetati.<br />

In Service Mo<strong>de</strong> aveti posibilitatea si ulterior sa efectuati modificarile dorite.<br />

Professional XL<br />

Ver2.01 (30.05.08)<br />

Beliebige Taste<br />

Sprache wählen<br />

<strong>de</strong>utsch<br />

↓ ↑ OK ESC<br />

Service Mo<strong>de</strong><br />

Bitte Co<strong>de</strong> eingeben<br />

_ _ _ _ _ _ _<br />

Pos Wert OK ESC<br />

Datum/Uhr stellen<br />

Datum : Di,09.05.06<br />

Uhrzeit: 12:49:21<br />

Pos Wert OK ESC<br />

Bitte wählen Sie<br />

Anlage<br />

Professional XL<br />

↓ ↑ OK ESC<br />

Bitte wählen Sie<br />

Anlagengrosse<br />

Professional XL 60<br />

↓ ↑ OK ESC<br />

Bitte wählen Sie<br />

Seriennummer<br />

00000000<br />

Pos Wert OK ESC<br />

Service<br />

00 Monate<br />

Tel………<br />

Pos Wert OK ESC<br />

Tipul statiei.<br />

Indicatia versiunii si a datei <strong>de</strong> fabricatie<br />

Continuare cu o tasta oarecare.<br />

Alegeti limba dorita cu tastele ↑↓ si confirmati cu tasta OK. Limbile care<br />

stau la dispozitie sunt: germana, engleza, franceza si spaniola.<br />

Pentru programarea parametrilor <strong>de</strong> operare este necesar codul <strong>de</strong><br />

service. In meniul “Service mo<strong>de</strong>” se tasteaza codul <strong>de</strong> acces. Acesta<br />

este disponibil doar firmei care a efectuat montajul si efectueaza<br />

punerea in functiune. Cu tastele POS si Wert introduceti codul. Dupa<br />

introducerea corecta a codului ajungeti in meniul <strong>de</strong> activare.<br />

Cu tastele Pos si Wert introduceti data (indicatie = TT.MM.JJ) si<br />

ora (indicatie = HH:MM:SS) si confirmati cu OK.<br />

Ziua saptamanii este introdusa automat.<br />

Este foarte important pentru introducerile corecte in jurnalul <strong>de</strong><br />

functionare!<br />

Alegeti cu tastele ↑↓ tipul statiei si confirmati cu OK.<br />

Alegeti cu tastele ↑↓ marimea statiei ( numarul <strong>de</strong> locuitori<br />

racordati ) si confirmati cu OK.<br />

Important pentru alegerea corecta a parametriilor presetati!<br />

Introduceti cu Pos si Wert numarul <strong>de</strong> serie, il regasiti pe rama statiei<br />

<strong>AQUAmax</strong> ® (BASIC/CLASSIC/PROFESSIONAL G) resp. pe dulapul<br />

electric sau pe placa <strong>de</strong> montaj (PROFESSIONAL XL) (nu pe cea a<br />

unitatii <strong>de</strong> <strong>control</strong>!) si confirmati cu OK.<br />

Va rugam sa tineti cont ca si numarul introdus sa fie corect.<br />

Exista posibilitatea <strong>de</strong> a introduce un interval <strong>de</strong> timp pentru efectuarea<br />

lucrarilor <strong>de</strong> intretinere. Dupa expirarea acestei perioa<strong>de</strong> va aparea un<br />

anunt in display (00 Monate=Funktion ausser Kraft- 00 luni= functiune<br />

scoasa din utilizare)<br />

Aditional poate fi introdus si un nr. <strong>de</strong> telefon (Service). In cazul in care<br />

aceasta optiune nu se utilizeaza <strong>unitate</strong>a preia automat nr. <strong>de</strong> service al ATB.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

9 / 42


Testlauf<br />

Belüfter 1<br />

=aus SW=1000<br />

Beliebige Taste…<br />

Grun<strong>de</strong>instellungen<br />

korrekt?<br />

ja nein<br />

ATB<br />

Umwelttechnologien<br />

Professional XL 60<br />

Ver2.01 (30.05.08)<br />

Vezi <strong>de</strong>scriere capitolul testul agregatelor, pag. 17.<br />

Important pentru functionarea corecta a agregatelor!<br />

Ati introdus date gresite? Prin apasarea tastei nein poate fi repetata<br />

prima punere in functiune.<br />

Daca datele sunt corecte, confirmati cu ja si va aparea pentru circa<br />

5 secun<strong>de</strong> indicatia cu datele producatorului, marimea statiei (numarul<br />

<strong>de</strong> locuitori racordati), numarul versiunii si data programarii.<br />

Dupa aceea are loc modificarea indicatiei <strong>de</strong> statut.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

10 / 42


Indicarea statutului <strong>de</strong> operare Nivelul 1. Nivelul 2.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

11 / 42


Indicarea statutului <strong>de</strong> operare<br />

Normalbetr 2h 58:55<br />

Belüften: 0h 00:30<br />

Schwimmer=1010<br />

beliebige Taste ...<br />

Fehler [10]<br />

Hochwasser<br />

max. Niveau<br />

beliebige Taste ...<br />

Statutul <strong>de</strong> operare va informeaza <strong>de</strong>spre actuala stare a statiei <strong>de</strong><br />

epurare. Sunt indicate umplerea, <strong>de</strong>nitrificarea, operarea normala, faza<br />

<strong>de</strong> sedimentare, evacuarea, modul econom si timpul ramas al fazei<br />

respective (exceptia o face modul econom). In timpul operarii normale si<br />

a operarii in modul econom este indicat timpul <strong>de</strong> aerare ramas<br />

respectiv pauza intre doua faze <strong>de</strong> aerare.<br />

In al treilea rand aveti informatii <strong>de</strong>spre actuala pozitie a plutitoarelor. 1<br />

sta pentru pozitia “inchis” a plutitorului, 0 pentru pozitia “<strong>de</strong>schis” a<br />

plutitorului.<br />

Ordinea in care sunt indicate corespun<strong>de</strong> numerotarii (racordul electric)<br />

din dulapul electric.<br />

Pos. 1 = SW1 = Plutitor SBR jos [HW, min]<br />

Pos. 2 = SW2 = Plutitor SBR sus [HW, max] nur PROFESSIONAL (BASIC si CLASSIC-0)<br />

Pos. 3 = SW3 = Plutitor bazin tampon jos [doar PROFESSIONAL (BASIC si CALSSIC-0)]<br />

Pos. 4 = SW4 = Plutitor bazin tampon sus doar la [PROFESSIONAL XL (optional la<br />

PROFESSIONAL G; BASIC si CLASSIC -0)]<br />

In cazul unui <strong>de</strong>ranjament apare in display raportul respectiv alternativ<br />

cu statutul <strong>de</strong> operare.<br />

Prin apasarea unei taste oarecare se aprin<strong>de</strong> iluminatia in display.<br />

Printr-o a doua apasare a unei taste oarecare ajungeti in primul meniu.<br />

Daca nu se mai apasa nici o tasta iluminatia se stinge dupa cca. 10 min.<br />

Primul meniu / submeniul (Nivel 1/ Nivel 2)<br />

Prin apasarea unei taste oarecare ajungeti in primul meniu (Nivel 1). Aici obtineti informatii<br />

suplimentare. Prin apasarea tastei “OK” in acest meniu, ajungeti la submeniul (Nivel 2)<br />

corespunzator punctului care se afla in paranteze .<br />

Prin apasarea ↓↑ alegeti optiunile posibile ale meniului. Prin apasarea tastei “ESC” ajungeti<br />

din meniu la indicatorul <strong>de</strong> statut.<br />

Info<br />

Fehler-Reset<br />

< Info ><br />

Service Info<br />

↓ ↑ OK ESC<br />

OK<br />

Professional XL 60<br />

Ver2.01 (30.05.08)<br />

Seriennummer<br />

00000003<br />

Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />

Indicarea informatiilor <strong>de</strong>spre actuala<br />

instalatie, tip si marime instalatie (persoane<br />

racordate), versiunea si numarul <strong>de</strong> serie.<br />

Afisajul poate fi parasit prin apasarea unei<br />

taste sau dupa 7 secun<strong>de</strong> afisajul dispare<br />

automat si se ajunge iarasi in primul meniu.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

12 / 42


Service Info<br />

Info<br />

< Service Info ><br />

Datum/Uhrzeit<br />

↓ ↑ OK ESC<br />

Afisare datei pentru urmatorul service si a numarului <strong>de</strong> telefon al firmei resposabile ( in<br />

cazul in care a fost introdus la punerea in functiune).<br />

Prin apasare unei taste oarecare va intoarceti inapoi in meniu.<br />

Data/ora (Datum / Uhrzeit)<br />

Service Info<br />

< Datum/Uhrzeit ><br />

Betriebszähler<br />

↓ ↑ OK ESC<br />

Cu “OK” ajungeti in submeniu. Cu tastele Pos si Wert fixati data si ora. Pentru<br />

documentarea in jurnalul <strong>de</strong> functionare este absolut necesara o setare corecta!<br />

Cu tasta Pos alegeti parametrul care doriti sa fie modificat (ziua saptamanii este<br />

setata automat). Prin apasarea tastei Wert se creste cu valoarea 1. Cu OK salvati<br />

modificarile iar indicatia sare in meniul 1. Cu ESC parasiti meniul fara salvare.<br />

Prin apasarea tastei ↓ ajungeti la punctul urmator.<br />

Contor ore <strong>de</strong> operare (Betriebszähler)<br />

Datum/Uhrzeit<br />

< Betriebszähler ><br />

Hand-Modus<br />

↓ ↑ OK ESC<br />

La rasfoirea acestui meniu apar urmatoarele submeniuri cu aceasi structura <strong>de</strong> operare:<br />

Belüfter = Aerator, Beschickungspumpe = Pompa <strong>de</strong> admisie, Klarwasserpumpe = Pompa<br />

<strong>de</strong> evacuare, Gesamtlaufzeit = Timp total <strong>de</strong> operare, Lfzt. Spar-Modus = Timp <strong>de</strong><br />

functionare in modul economic. Aici sunt protocolati timpii totali <strong>de</strong> functionare ai agregatelor<br />

<strong>de</strong> la punerea in functiune. Sunt indicate si agregate (d.ex. aerator 2 la PROFESSIONAL G),<br />

chiar daca acestea nu sunt montat la unele instalatii. Ca timp <strong>de</strong> functionare apare atunci 0.<br />

Cu ”ESC” parasiti meniul.<br />

Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />

Modul <strong>de</strong> operare manual (Hand-Modus)<br />

Betriebszähler<br />

< Hand-Modus ><br />

Logbuch<br />

↓ ↑ OK ESC<br />

OK<br />

OK<br />

ESC<br />

OK<br />

ESC<br />

OK<br />

ESC<br />

Service<br />

03.01.09<br />

Tel.05731302300<br />

beliebige Taste<br />

Datum/Uhr stellen<br />

Datum : Di,09.05.06<br />

Uhrzeit: 12:49:21<br />

Pos Wert OK ESC<br />

Betriebszähler<br />

Belüfter1<br />

4h 10:49<br />

↓ ↑ ESC<br />

pot. Kontakt<br />

< Belüfter1 ><br />

Belüfter2<br />

↓ ↑ OK ESC<br />

La rasfoirea acestui meniu apar urmatoarele submeniuri cu aceasi structura <strong>de</strong> operare:<br />

OK<br />

OK<br />

ESC<br />

Datum/Uhrzeit<br />

geän<strong>de</strong>rt<br />

Hand-Modus (1010)<br />

Belüfter1<br />

aus I= 0,0A<br />

an aus ESC<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

13 / 42<br />

Service Info<br />

< Datum/Uhrzeit ><br />

Betriebszähler<br />

↓ ↑ OK ESC


Hand-Modus<br />

< Logbuch ><br />

Einstellungen<br />

↓ ↑ OK ESC<br />

Belüfter = Aerator, Beschickungspumpe = Pompa <strong>de</strong> admisie, Klarwasserpumpe = Pompa<br />

<strong>de</strong> evacuare, SWx = plutitor.<br />

Aici aflati informatii <strong>de</strong>spre amperajul actual al agregatelor si <strong>de</strong>spre pozitia plutitoarelor.<br />

Dupa ce ati trecut in unul din aceste submeniuri puteti testa fiecare agregat in parte sau<br />

activa in cazul lucrarilor <strong>de</strong> intretinere in<strong>de</strong>pen<strong>de</strong>nt <strong>de</strong> programul <strong>de</strong> operare automat. Cu OK<br />

confirmati agregatul respectiv. Cu tastele “An” (pornit) respectiv “Aus” (oprit) activati sau<br />

<strong>de</strong>zactivati agregatul respectiv.<br />

In cazul in care a aparut un <strong>de</strong>ranjament la un anumit agregat, atunci apare “Fehler” in<br />

penultimul rand pe display. Daca totul este in ordine este indicat amperajul momentan al<br />

agregatului.<br />

Grupurile <strong>de</strong> agregate sunt conectate intre ele, astfel incat nu se poate folosi modul <strong>de</strong><br />

operare manual simultan pentru <strong>de</strong> ex. aerator si pompa <strong>de</strong> evacuare. Daca un agregat sau<br />

un grup <strong>de</strong> agregate functioneaza acesta se va opri imediat la operarea altui agregat in<br />

modul <strong>de</strong> operare manual.<br />

ATENTIE! Modul <strong>de</strong> operare manual este in<strong>de</strong>pen<strong>de</strong>nt <strong>de</strong> pozitia actuala a<br />

plutitoarelor <strong>de</strong> comutare!<br />

Dupa 15 minute instalatia trece automat din modul <strong>de</strong> operare manual in cel automat.<br />

Parasiti meniul cu tasta “ESC”.<br />

Dupa incheierea operarii manuale, instalatia porneste din punctul in care se afla in momentul<br />

accesarii meniului manual.<br />

Daca instalatia se afla in faza <strong>de</strong> sedimentare, atunci aceasta va continua sa cronometreze<br />

timpul necesar ramas pentru aceasta faza.<br />

Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />

Jurnal electronic (Logbuch)<br />

ESC<br />

OK<br />

Tageswert<br />

< Meldung ><br />

Fehler<br />

↓ ↑ OK ESC<br />

ESC<br />

OK<br />

Meldung<br />

10.05.06 12:24:59<br />

Belüfter1<br />

↓ ↑ --> ESC<br />

Nächste<br />

Meldung<br />

In jurnalul electronic sunt memorati timpi <strong>de</strong> functionare, evenimente si <strong>de</strong>ranjamente.<br />

Astfel in cazul unui <strong>de</strong>fect sau lucrarilor <strong>de</strong> intretinere se pot obtine repe<strong>de</strong> informatii<br />

folositoare.<br />

Cu “OK” ajungeti in submeniu. Cu sagetile ↓ si “OK” alegeti parametrul dorit (Meldung =<br />

Raport; Fehler = Deranjament; Ereignis = Eveniment).<br />

Este intot<strong>de</strong>auna indicat ultimul <strong>de</strong>ranjament, raport, eveniment etc. Cu sagetile ↓↑se poate<br />

parcurge toata lista. Cu sageata → puteti obtine informatii suplimentare <strong>de</strong>spre actualul<br />

eveniment.<br />

Unitatea memoreaza maxim 4096 <strong>de</strong> informatii. La atingerea numarului maxim, noile<br />

evenimete sunt trecute pe locul evenimentului celui mai vechi, adica evenimentul 4097 va lua<br />

locul evenimetului 1/4096. Indicat este intot<strong>de</strong>auna ultimul eveniment inregistrat.<br />

Parasiti meniul cu tasta “ESC”.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

14 / 42<br />

Meldung<br />

Meldung<br />

--><br />

10.05.06 12:24:59<br />

auto aus<br />

↓ ↑ --> ESC<br />

--><br />

10.05.06 12:24:59<br />

650 / 650<br />

↓ ↑ --> ESC<br />

--><br />

Vorhergehen<strong>de</strong><br />

Meldung


Parametrii in parte:<br />

Raport (Meldung) (maxim 4096)<br />

Aici este documentata complet orice modificare care are loc in modul <strong>de</strong> operare al<br />

instalatiei. De exemplu cand a comutat un plutitor, cand a avut loc ultima evacuare, cand s-a<br />

trecut din operare manuala in automata, etc.<br />

Deranjament (Fehler) (maxim 256)<br />

Aici sunt memorate toate <strong>de</strong>ranjamentele sau <strong>de</strong>fectiunile aparute. Explicatia la fiecare<br />

<strong>de</strong>ranjament posibil o gasiti in anexa. Dupa resetarea unui <strong>de</strong>ranjament, este documentata<br />

aceasta resetare ca raport cu data si cu remarca “inaktiv”.<br />

Eveniment (Ereignis) (maxim 256)<br />

Aici este documentata orice modificare manuala efectuata (d.ex. schimbarea timpului <strong>de</strong><br />

operare a unui agregat) si ca<strong>de</strong>rile <strong>de</strong> tensiune.<br />

Timp <strong>de</strong> functionare (Laufzeit) (maxim 256)<br />

In acest meniu sunt memorati timpii <strong>de</strong> functionare saptamanali.<br />

Valori zilnice (Tageswert) (maxim 512)<br />

Timpi <strong>de</strong> operare pe zi.<br />

Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />

Setari (Einstellungen)<br />

Logbuch<br />

< Einstellungen ><br />

Stromgrenzen<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

Beschickung<br />

Dauer<br />

= 0,8 Minuten<br />

↓ ↑ ESC<br />

Cu “OK” ajungeti in submeniul corespunzator. Cu sagetile ↓↑ puteti citii actualii parametri<br />

setati.<br />

Valorile <strong>de</strong> setare standard a agregatelor le gasiti in anexa. O modificare a acestor parametrii<br />

este posibila doar in “Service Mo<strong>de</strong>”. Aici gasiti si <strong>de</strong>scrierea fiecarui parametru in parte.<br />

Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />

Amperaj, valori limita (Stromgrenzen)<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

15 / 42


Daca valorile energetice preluate sunt sub nivelul limita este activata o alarma. Modificari se<br />

pot efectua doar in Service-Mo<strong>de</strong> (vezi pag 22/24).<br />

Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />

Modul <strong>de</strong> service (Service Mo<strong>de</strong>)<br />

Einstellungen<br />

< Service Mo<strong>de</strong> ><br />

Fehler-Reset<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

ATENTIE! Acest meniu poate fi accesat doar <strong>de</strong> personalul care a efectuat<br />

montajul instalatiei sau <strong>de</strong> personalul <strong>de</strong> service. Pentru a accesa acest meniu<br />

aveti nevoie <strong>de</strong> codul <strong>de</strong> acces.<br />

In “Service Mo<strong>de</strong>” sunt modificabili toti parametrii <strong>de</strong> operare ai instalatiei. In cazul setarilor<br />

necorespunzatoare, care pot duce la <strong>de</strong>teriorarea echipamentului, firma ATB Umwelttechnologien<br />

refuza orice pretentie <strong>de</strong> garantie!<br />

Service-Mo<strong>de</strong> este <strong>de</strong>scris <strong>de</strong>taliat in alt capitol.<br />

Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />

Resetarea <strong>de</strong>ranjamentelor (Fehler-Reset)<br />

Service Mo<strong>de</strong><br />

< Fehler-Reset ><br />

OK Alle Fehler löschen?<br />

Info<br />

↓ ↑ OK ESC<br />

ja<br />

nein<br />

ja nein<br />

La aparitia unui <strong>de</strong>ranjament sau <strong>de</strong>fect, acesta este indicat in display ca text si<br />

printr-un semnal acustic. Semnalul acustic inceteaza in momentul apasarii unei<br />

taste oarecare. Display –ul palpaie pana in momentul resetarii <strong>de</strong>ranjamentului<br />

(confirmare cu “ja” a indicatiei “Alle Fehler löschen”). Dupa resetare, <strong>de</strong>ranjamentul<br />

se gaseste in jurnalul electronic.<br />

Daca nu efectuati o resetare a <strong>de</strong>ranjamentului, acesta nu va mai fi in cazul unei<br />

noi aparitii inca odata receptionat.<br />

Doar dupa resetarea automata la 72 <strong>de</strong> ore poate fi recunoscut daca<br />

<strong>de</strong>ranjamentul respectiv mai este actual sau reapare.<br />

O resetare automata a unui <strong>de</strong>ranjament este memorata in jurnalul electronic cu<br />

remarca “inaktiv”.<br />

Va rugam la aparitia unui <strong>de</strong>ranjament sa informati personalul <strong>de</strong> service. Acesta<br />

se va ocupa <strong>de</strong> remedierea <strong>de</strong>ranjamentului.<br />

Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />

Info (ve<strong>de</strong>ti mai sus.)<br />

Service Mo<strong>de</strong><br />

Bitte Co<strong>de</strong> eingeben<br />

_ _ _ _ _ _<br />

Pos Wert OK ESC<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

16 / 42


Modul <strong>de</strong> service (Service Mo<strong>de</strong>)<br />

Einstellungen<br />

< Service Mo<strong>de</strong> ><br />

Fehler-Reset<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

Service Mo<strong>de</strong><br />

Bitte Co<strong>de</strong> eingeben<br />

_ _ _ _ _ _<br />

Pos Wert OK ESC<br />

ATENTIE! Acest meniu poate fi<br />

accesat doar <strong>de</strong> personalul care a<br />

efectuat montajul instalatiei sau <strong>de</strong><br />

personalul <strong>de</strong> service. Pentru a<br />

accesa acest meniu aveti nevoie <strong>de</strong><br />

codul <strong>de</strong> acces. In “Service Mo<strong>de</strong>”<br />

sunt modificabili toti parametrii <strong>de</strong><br />

operare ai instalatiei. Va rugam sa<br />

tineti cont <strong>de</strong> faptul ca datele incorecte<br />

pot duce la o functionare <strong>de</strong>ficitara.<br />

Validitatea modificarilor efectuate<br />

nu este <strong>control</strong>ata. In cazul setarilor<br />

necorespunzatoare, care pot<br />

duce la <strong>de</strong>teriorarea echipamentului,<br />

firma ATB Umwelttechnologien<br />

refuza orice pretentie <strong>de</strong> garantie!<br />

Va rugam sa ne contactati, va stam<br />

cu placere la dispozitie.<br />

Fiecare parametru in parte este<br />

prezentat pe urmatoarele pagini.<br />

Pentru intrebari va rugam sa ne<br />

contactati!<br />

La accesarea acestui meniu, toate<br />

agregatele vor fi oprite (exceptie face<br />

testul agregatelor).<br />

La parasirea acestui meniu, programul<br />

va continua din punctul in care<br />

era la momentul accesarii meniului<br />

<strong>de</strong> service.<br />

Daca se efectueaza testul aggregatelor<br />

in timpul fazei <strong>de</strong> sedimentare,<br />

atunci instalatia trece in modul <strong>de</strong><br />

functionare normal pentru o perioada<br />

<strong>de</strong> timp egala cu cea care ar fi ramas<br />

din faza <strong>de</strong> sedimentare.<br />

ESC<br />

OK<br />

ESC<br />

Alarmkontakt<br />

< Service ><br />

Sprache wählen<br />

↓ ↑ OK ESC<br />

Service<br />

< Sprache wählen ><br />

Anlagengrösse<br />

↓ ↑ OK ESC<br />

Sprache wählen<br />

< Anlagengröße ><br />

Seriennummer<br />

↓ ↑ OK ESC<br />

Anlagengrösse<br />

< Seriennummer ><br />

Testlauf<br />

OK ESC<br />

Seriennummer<br />

<br />

Fehlerliste<br />

↓ ↑ OK ESC<br />

Testlauf<br />

<br />

Einstellunge<br />

↓ ↑ OK ESC<br />

Fehlerliste<br />

< Einstellungen ><br />

Stomgrenzen<br />

↓ ↑ OK ESC<br />

Einstellungen<br />

< Stromgrenzen><br />

Erweiterung<br />

↓ ↑ OK ESC<br />

Stromgrenzen<br />

< Erweiterung><br />

Werkseinstellung<br />

↓ ↑ OK ESC<br />

Erweiterung<br />

<br />

Einfahren<br />

↓ ↑ OK ESC<br />

Werkseinstellungen<br />

< Einfahren ><br />

Phosphatfällung<br />

↓ ↑ OK ESC<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

17 / 42<br />

OK<br />

OK<br />

OK<br />

OK<br />

ESC<br />

OK<br />

OK<br />

ES<br />

OK<br />

ESC<br />

OK<br />

OK<br />

ESC<br />

ESC<br />

OK<br />

OK<br />

OK<br />

ESC<br />

ESC<br />

ESC<br />

ESC<br />

ESC<br />

Service<br />

07.01.09<br />

Tel:05731302300<br />

RST EDIT ESC<br />

Sprache wählen<br />

<strong>de</strong>utsch<br />

↓ ↑ OK ESC<br />

Bitte wählen Sie<br />

Anlage<br />

Professional XL<br />

↓ ↑ OK ESC<br />

Bitte wählen Sie<br />

Seriennummer<br />

10000000<br />

Pos Wert OK ESC<br />

Testlauf<br />

Belüfter 1<br />

= aus SW = 1000<br />

beliebige Taste<br />

Fehler [0]<br />

Belüfter 1<br />

Strom Min<br />

↓ ↑ Info ESC<br />

Beschickung<br />

Dauer<br />

= 0,8 Minute<br />

↓ ↑ EDIT ESC<br />

Stromgrenzen<br />

Belüfter 1<br />

l=3,0A…7,5A<br />

↓ ↑ EDIT ESC<br />

Protokoll RS232<br />

BeschickungDeni<br />

Pumpenstoß<br />

↓ ↑ OK ESC<br />

Bitte wählen Sie<br />

Grun<strong>de</strong>instellunge<br />

ja nein<br />

Einfahren<br />

Zähler<br />

=263<br />

EDIT ESC


Service<br />

Exista posibilitatea setarii unui interval <strong>de</strong> service (max 12 luni).<br />

Cand aceasta perioada expira proControl® ne anunta (00-Monate = Funktion ausser Kraft<br />

adica 00 luni = functie scoasa din utilizare).<br />

Aditional mai poate fi introdus si un numar <strong>de</strong> service. Daca nu se introduce nici un numar<br />

atunci <strong>unitate</strong>a preia automat numarul ATB.<br />

Cu Pos, Wert si OK pot fi modificati si salvati toti parametrii.<br />

Dupa efectuarea lucrarilor <strong>de</strong> service prin apasarea tastei RST si ‘’da’’ (‘’ja’’) se introduce<br />

urmatorul interval <strong>de</strong> timp.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

18 / 42


Setarea limbajului <strong>de</strong> operare (Sprache wählen)<br />

Alarmkontakt<br />

< Sprache wählen ><br />

Anlagengröße<br />

↓ ↑ OK ESC<br />

Limbajul posibil este: germana, engleza, franceza sau spaniola. Alegeti limbajul dorit<br />

confirmati cu “OK” si veti ajunge in urmatorul meniu. Cu “ESC” parasiti meniul fara a memora<br />

schimbarile.<br />

Locuitori racordati (Anlagengröße)<br />

Sprache wählen<br />

< Anlagengröße ><br />

Seriennummer<br />

↓ ↑ OK ESC<br />

Aici se selecteaza sau modifica tipul instalatiei (<strong>AQUAmax</strong>® PROFESSIONAL G, XL,<br />

CLASSIC sau BASIC). Prin alegerea tipului instalatiei <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> incarca automat<br />

valorile <strong>de</strong> operare corespunzatoare astfel nu mai sunt necesare modificari in meniul Setari<br />

“Einstellunge”. Parametrii corespunzatori ii gasiti in anexa.<br />

Seria (Seriennummer)<br />

Anlagengröße<br />

<br />

Testlauf<br />

↓ ↑ OK ESC<br />

Aici se introduce sau modifica numarul <strong>de</strong> serie al instalatiei <strong>AQUAmax</strong>®.<br />

Testul agregatelor (Testlauf)<br />

Seriennummer<br />

< Testlauf ><br />

Fehlerliste<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

OK<br />

OK<br />

ESC<br />

OK<br />

OK<br />

OK<br />

OK<br />

ESC<br />

Sprache wählen<br />

<strong>de</strong>utsch<br />

↓ ↑ OK ESC<br />

Bitte wählen Sie<br />

Anlage<br />

Professional XL<br />

↓ ↑ OK ESC<br />

Bitte wählen Sie<br />

Seriennummer<br />

10000000<br />

↓ ↑ OK ESC<br />

Testlauf<br />

Belüfter1<br />

=aus SW = 1000<br />

beliebige Taste...<br />

OK<br />

OK<br />

ESC<br />

Schwimmerschalter<br />

Anlagengröße<br />

Anlagengröße<br />

Professiona XL 60<br />

↓ ↑ OK ESC<br />

Testlauf<br />

Belüfter1<br />

=ein SW = 1010<br />

beliebige Taste...<br />

In acest meniu puteti testa functionalitatea fiecarui agregat in parte si a plutitoarelor.<br />

Dupa comutarea unui plutitor oarecare porneste testul agregatelor. Fiecare agregat<br />

functioneaza cca. 5 secun<strong>de</strong> in faza <strong>de</strong> test. Este indiferent care plutitor se alege pentru<br />

pornirea testului, important este doar ca acesta sa treaca din pozitia inchis in <strong>de</strong>schis sau<br />

invers. Daca un plutitor a comutat se au<strong>de</strong> prin zgomotul tipic <strong>de</strong> comutare sau se ve<strong>de</strong> in<br />

display. Cifra 1 corespun<strong>de</strong> plutitor inchis, 0 corespun<strong>de</strong> plutitor <strong>de</strong>schis. Indicatorul din<br />

display se schimba doar dupa ce testul unui agregat este incheiat<br />

Prima cifra este indicatorul plutitorului <strong>de</strong> jos din SBR (SW1, Hw,min), a doua este indicatorul<br />

plutitorului <strong>de</strong> sus din SBR (SW2, HW,max), a treia este indicatorul plutitorului <strong>de</strong> jos din<br />

bazinul <strong>de</strong> stocare (SW3) iar a patra este indicatorul plutitorului <strong>de</strong> sus din bazinul <strong>de</strong> stocare<br />

(SW4, optional).<br />

In cazul <strong>de</strong> mai sus este inchis doar plutitorul <strong>de</strong> jos din SBR. Prin comutarea plutitorului <strong>de</strong><br />

jos din bazinul <strong>de</strong> stocare este luat in functiune primul agregat (aerator 1). Dupa cca. 5<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

19 / 42<br />

5 sec<br />

Testlauf<br />

Beschicker1<br />

=aus SW = 1010<br />

beliebige Taste...


secun<strong>de</strong> acesta se opreste si porneste urmatorul agregat. Ordinea <strong>de</strong> test este: Aerator 1<br />

(Belüfter 1), Aerator 2 (Belüfter 2) – doar la Xl pana la 100 , Pompa <strong>de</strong> alimentare 1<br />

(Beschickung 1)- doar la PROFESSIONAL G, Pompa <strong>de</strong> alimentare 2 (Beschickung 2) – la<br />

XL pana la 125, Pompa <strong>de</strong> evacuare 1 (Klarwasserpumpe 1), Pompa <strong>de</strong> evacuare 2<br />

(Klarwasserpumpe 2)- doar la XL pana la 100, Pompa <strong>de</strong> namol ( Schlammpumpe)- exceptie<br />

la BASIC.<br />

Daca echipamentul dumneavoastra este dotat cu un AQUAswitch (BASIC) testul<br />

poate fi efectuat doar daca bazinul este plin si <strong>unitate</strong>a submersata sau scoasa<br />

afara.<br />

Testul agregatelor se poate opri oricand prin apasarea unei taste oarecare.<br />

ATENTIE! Daca un agregat nu functioneaza corespunzator, acest <strong>de</strong>ranjament nu<br />

este trecut in jurnal si nu apare nici un raport!<br />

Lista <strong>de</strong>ranjamentelor (Fehlerliste)<br />

Testlauf<br />

< Fehlerliste ><br />

Einstellungen<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

Fehler [ 0]<br />

Belüfter1<br />

Strom Min.<br />

↓ ↑ Info ESC<br />

Fehler [0 – 15]<br />

Fehler [ 0]<br />

Belüfter1<br />

inaktiv<br />

↓ ↑ Info ESC<br />

Fehler [0 – 15]<br />

Info<br />

ESC<br />

Fehler [ 0]<br />

Belüfter1<br />

12.05.06 12:25:33<br />

↓ ↑ Del ESC<br />

Fehler [ 0]<br />

Belüfter1<br />

Priorität = 3<br />

↓ ↑ Edit ESC<br />

Fehler [ 0]<br />

Belüfter1<br />

Zähler = 3<br />

↓ ↑ Del ESC<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

20 / 42<br />

Del<br />

Edit<br />

Del<br />

OK<br />

ESC<br />

Fehler [ 0]<br />

Belüfter1<br />

Kein Datum<br />

↓ ↑ Del ESC<br />

ESC<br />

Fehler [ 0]<br />

Belüfter1<br />

Priorität = 3<br />

↓ ↑ OK ESC<br />

Fehler [ 0]<br />

Belüfter1<br />

Zähler = 0<br />

↓ ↑ Del ESC<br />

ESC


Sunt posibile 16 cauze diferite <strong>de</strong> <strong>de</strong>ranjamente (0-15; lista in anexa). Cu ajutorul sagetilor<br />

poate fi aleasa fiecare cauza in parte. Daca <strong>de</strong>ranajmentul respectiv nu este cauza<br />

malfunctiunii apare in display „inaktiv”. Altfel apare cauza <strong>de</strong>ranjamentului (d.ex. Strom min =<br />

Amperaj min – amperajul agregatului este prea mic).<br />

ATENTIE! La resetarea unui <strong>de</strong>ranjament acesta este anulat si in display este<br />

indicat „inactiv”!<br />

Prin apasarea tastei „Info” obtineti informatii cu privire la ultima aparitie a acestui<br />

<strong>de</strong>ranjament. Prin apasarea tastei „DEL” este stearsa informatia si contorul.<br />

Prin apasarea tastei ↓ ajungeti la parametrul “Prioritate” (“Priorität”). Acest parametru<br />

hotaraste felul in care trebuie tratat <strong>de</strong>ranjamentul respectiv.<br />

Prioritatile <strong>de</strong>ranjamentelor:<br />

1 = Deranjamentul este indicat in display, dar nu este activata alarma acustica si<br />

<strong>de</strong>ranjamentul nu este directionat spre alta receptie (peste contactul fara potential<br />

incorporat, via GSM d.ex.). Deranjamentul este inregistrat in jurnalul electronic.<br />

2 = Deranjamentul este indicat in display, evt. alarmare acustica, releul <strong>de</strong> alarmare<br />

generala. Deranjamentul este inregistrat in jurnalul electronic si in lista<br />

<strong>de</strong>ranjamentelor.<br />

3 = In plus fata <strong>de</strong> prioritatea 2 – Releul <strong>de</strong> comunicare activ<br />

Cu ajutorul tastei „Edit” ajungeti in modul <strong>de</strong> setare si puteti schimba cu ajutorul sagetilor<br />

prioritatea unui <strong>de</strong>ranjament. Cu „OK” salvati schimbarile efectuate, cu „ESC” parasiti meniul<br />

fara a memora.<br />

ATENTIE! La setarea unui grad <strong>de</strong> prioritate fals nu este generata o alarma!<br />

In cazul in care se seteaza fara acordul firmei ATB prioritatea 1 pentru un<br />

<strong>de</strong>ranjament, atunci sunt excluse remedieri in garantie a <strong>de</strong>fectiunilor care<br />

ar putea sta in corelatie cu aceasta setare.<br />

Prin apasarea tastei ↓ ajungeti la parametrul “Zähler” (contor).<br />

Acesta memoreaza <strong>de</strong> cate ori a aparut <strong>de</strong>ranjamentul respectiv. Prin apasarea tastei “Del”<br />

se resetaza acest contor.<br />

Setari (Einstellungen)<br />

ATENTIE! Valoarea acestui contor se mareste cu 1 doar daca raportul<br />

<strong>de</strong>ranajmentului a fost activat prin resetarea <strong>de</strong>ranjamentului (retineti: daca<br />

apare un <strong>de</strong>ranjament, acesta va fi doar atunci inca o data inregistrat daca a<br />

fost receptionat si resetat la intaia aparitie).<br />

CLASSIC / PROFESSIONAL:<br />

Fehlerliste<br />

< Einstellungen ><br />

Stromgrenzen<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

Beschickung<br />

Dauer<br />

= 0,8 Minuten<br />

↓ ↑ EDIT ESC<br />

EDIT<br />

OK<br />

ESC<br />

Beschickung<br />

Dauer<br />

= 00,8 Minuten<br />

Pos Wert OK ESC<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

21 / 42


BASIC:<br />

Fehlerliste<br />

< Einstellungen ><br />

Stromgrenzen<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

Beschickung<br />

Anzahl<br />

= 5<br />

↓ ↑ EDIT ESC<br />

In spatele acestui meniu se gasesc toate posibilitatile <strong>de</strong> modificare a parametrilor <strong>de</strong><br />

operare. Acestia sunt incarcati automat in momentul in care se seteaza numarul <strong>de</strong> persoane<br />

racordate, dar pot fi modificati <strong>de</strong> catre firma montatoare daca este necesar. Prin apasarea<br />

tastei ↑ ajungeti pe rand la fiecare parametru modificabil.<br />

Cu tasta “Edit” ajungeti in modul <strong>de</strong> setare in care cu “Pos” ajungeti la pozitia dorita si cu<br />

“Wert” modificati valoarea respectiva. Cu “OK” confirmati si memorati modificarile efectuate,<br />

cu “ESC” parasiti meniul fara a memora modificarile.<br />

Durata/numar alimentari (BASIC Beschickung Anzahl)<br />

Acesta reprezinta timpul <strong>de</strong> functionare a pompei <strong>de</strong> alimentare (la BASIC numarul <strong>de</strong><br />

alimentari) a reactorului SBR. Apa din bazinul <strong>de</strong> stocare este trecuta in cel <strong>de</strong> tratare.<br />

(BASIC / CLASSIC: Retentie grosier / namol)<br />

Cu alimentarea porneste un nou ciclu. Frecventa in care are loc alimentarea este data <strong>de</strong> timpul <strong>de</strong> pauza intre<br />

doua alimentari si <strong>de</strong> lungimea unui ciclu. Ultima alimentare are loc cel tarziu la 2 ore inainte <strong>de</strong> inceperea fazei<br />

<strong>de</strong> sedimentare, pentru a putea garanta un timp suficient <strong>de</strong> epurare inainte <strong>de</strong> sedimentare.<br />

Daca sunt prevazuti 4 plutitori (posibil doar la PROFESSIONAL XL (standard) si G ) are loc in afara <strong>de</strong> setarea<br />

dupa timp, o alimentare cand plutitorul SW4 din bazinul <strong>de</strong> stocare inchi<strong>de</strong> si semnaleaza astfel un bazin plin si<br />

plutitorul SW2 din bazinul <strong>de</strong> tratare nu a inchis. Adica mai este suficient volum <strong>de</strong> stocare in bazinul SBR. Toate<br />

acestea doar atunci, inainte ca faza <strong>de</strong> sedimentare sa inceapa resp. mai sunt cel putin 2 ore pana la inceperea<br />

acesteia.<br />

Alimentarea face parte din faza <strong>de</strong> <strong>de</strong>nitrificare, adica odata cu inceperea alimentarii porneste faza <strong>de</strong><br />

<strong>de</strong>nitrificare.<br />

Pauza alimentare (Beschickung Pause)<br />

Timpul <strong>de</strong> pauza intre doua alimentari.<br />

EDIT<br />

OK<br />

ESC<br />

Durata <strong>de</strong>nitrificarii (Denitrifikation Dauer)<br />

Imediat dupa fiecare alimentare este prevazuta o faza <strong>de</strong> <strong>de</strong>nitrificare. Pentru aceasta faza<br />

pot fi prevazuti timpi <strong>de</strong> aerare diferiti, pentru a obtine un proces optim. Prin setarea valori 0<br />

este posibila functionarea instalatiei si fara <strong>de</strong>nitrificare.<br />

Denitrificare aerare pornita (Denitrifikation Belüftung ein)<br />

Timpul <strong>de</strong> aerare in faza <strong>de</strong> <strong>de</strong>nitrificare.<br />

Denitrificare aerare oprita (Denitrifikation Belüftung aus)<br />

Timpul <strong>de</strong> pauza intre doua aerari in faza <strong>de</strong> <strong>de</strong>nitrificare.<br />

Beschickung<br />

Anzahl<br />

= 005<br />

Pos Wert OK ESC<br />

Operare normala aerare pornita (Normalbetrieb Belüftung ein)<br />

Timpul <strong>de</strong> aerare in modul normal <strong>de</strong> operare.<br />

Dupa faza <strong>de</strong> <strong>de</strong>nitirificare urmeaza faza <strong>de</strong> aerare (nitrificare / eliminare carbon). Si in aceasta faza<br />

se lucreaza cu o aerare intermitenta.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

22 / 42


Operare normala aerare oprita (Normalbetrieb Belüftung aus)<br />

Timpul <strong>de</strong> pauza intre doua aerari in faza <strong>de</strong> operare normala.<br />

Durata sedminetare (Absetzen Dauer)<br />

Lungimea perioa<strong>de</strong>i <strong>de</strong> sedimentare dupa operarea normala.<br />

Daca a aparut o alarma <strong>de</strong> inundatie (SW2 si SW4 au cuplat), atunci timpul <strong>de</strong> sedimentare este<br />

injumatatit.<br />

Durata faza <strong>de</strong> aerare (Belüftungsphase Dauer)<br />

Durata ciclului <strong>de</strong> tratare (timpul intre prima alimentare [= start ciclu] si inceputul fazei <strong>de</strong><br />

sedimentare, <strong>de</strong>ci perioada <strong>de</strong> timp inclusiv alimentare si <strong>de</strong>nitrificare)<br />

Durata evacuare apa epurata (Klarwasserabzug Dauer)<br />

Dupa incheierea fazei <strong>de</strong> sedimentare are loc evacuarea apelor epurate. La ajungerea<br />

nivelului minim in bazinul SBR (Hw, min), care este semnalat <strong>de</strong> plutitorul <strong>de</strong> jos (SW1), se<br />

incheie evacuarea. In cazul in care, evacuarea apelor nu are loc in perioada <strong>de</strong> timp setata<br />

este activata o alarma „Deranjament [09] (Fehler) evacuare apa epurata, timp <strong>de</strong>pasit”.<br />

Durata evacuare namol (BASIC Schlammabzug Anzahl)<br />

PROFESSIONAL XL: Evacuarea namolului in exces incheie ciclul. Dupa evacuarea apei<br />

epurate intra in functiune pompa <strong>de</strong> evacuare namol pentru timpii setati.<br />

PROFESSIONAL G / BASIC / CLASSIC: Evacuarea namolului in exces are loc o singura<br />

data, in timpul fazei <strong>de</strong> aerare. Imediat dupa o perioada <strong>de</strong> aerare are loc evacuarea<br />

namolului pentru durata <strong>de</strong> timp setata. ( BASIC in functie <strong>de</strong> nr. alimentari)<br />

Atata vreme cat instalatia se afla in perioada <strong>de</strong> adaptare, namolul in exces nu este evacuat.<br />

Clatire pompe (Spülung Pumpen)<br />

La jumatatea fazei <strong>de</strong> sedimentare sunt activate pompele <strong>de</strong> evacuare. De trei ori pentru<br />

timpul setata si la un interval <strong>de</strong> un minut.<br />

Prin aceasta clatire a pompelor se evacueaza namolul <strong>de</strong>pus in carcasa. Astfel apele epurate evacuate sunt<br />

aproape fara sediment.<br />

Modul econom, aerare pornita (Sparmodus Belüftung ein)<br />

La <strong>AQUAmax</strong>® PROFESSIONAL: In cazul in care in bazinul <strong>de</strong> tratare este prea putina apa<br />

(SW1 = jos) inainte <strong>de</strong> inceperea fazei <strong>de</strong> sedimentare si/sau in bazinul <strong>de</strong> stocare este prea<br />

putina apa (SW3 = jos) astfel incat bazinul <strong>de</strong> tratare nu poate fi umplut, instalatia trece<br />

automat in modul <strong>de</strong> operare econom.<br />

<strong>AQUAmax</strong>® BASIC si CLASSIC: in cazul in care plutitorul (SW1) nu cupleaza cu doua ore<br />

inainte <strong>de</strong> faza <strong>de</strong> sedimentare echipamentul trece automat in modul <strong>de</strong> operare econom.<br />

Alimentarea urmeaza regulat.<br />

Aerarea este redusa la un minim suficient pentru a mai intretine activitatea biologica. Durata<br />

aerarii poate fi setata. Modul econom se incheie in momentul in care in bazinul <strong>de</strong> stocare<br />

este suficienta apa (PROFESSIONAL SW3 = sus) sau plutitorul s-a ridicat.<br />

(BASIC/CLASSIC:SW1 = sus)<br />

Modul econom, aerare oprita (Sparmodus Belüftung aus)<br />

Timpul <strong>de</strong> pauza intre doua aerari in modul <strong>de</strong> operare econom.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

23 / 42


Amperaj, valori limita (Stromgrenzen)<br />

Einstellungen<br />

< Stromgrenzen ><br />

Erweiterung<br />

↓ ↑ OK ESC<br />

Valorile setate pentru curentul electric al fiecarui agregat indica campul in care agregatele<br />

functioneaza corect. Daca <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> masoara un curent electric sub sau peste<br />

limita setata pentru un agregat, atunci este generata o alarma.<br />

ATENTIE! Daca curentul electric este sub limita <strong>de</strong> jos, agregatul va fi in<br />

continuare in functiune. Daca nu efectuati o resetare a raportului <strong>de</strong><br />

<strong>de</strong>ranjament generat, atunci acest <strong>de</strong>ranjament nu va mai fi inregistrat la o<br />

noua aparitie!<br />

Daca curentul electric este peste limita <strong>de</strong> sus a unui agregat, agregatul va fi<br />

oprit. Acesta nu poate fi repus in functiune atata vreme cat <strong>de</strong>ranjamentul nu<br />

este resetat.(Resetare auromata in 72 <strong>de</strong> ore)<br />

Cu tasta „Edit” ajungeti in modul <strong>de</strong> setare. Cu „Pos” alegeti pozitia si cu „Wert” modificati<br />

valoarea pozitiei respective. CU „Ok” se salveaza setarile efectuate, cu „ESC” parasiti meniul<br />

fara a salva schimbarile.<br />

Extin<strong>de</strong>re (Erwieterung)<br />

Stromgrenzen<br />

< Erweiterung ><br />

Werkseinstellung<br />

↓ ↑ OK ESC<br />

OK<br />

OK<br />

ESC<br />

ESC<br />

Parametrii special <strong>de</strong> setare pentru fiecare tip <strong>de</strong> instalatie in parte.<br />

Alimentare Deni (Beschickung Deni)<br />

Timpul pomparii (unice) <strong>de</strong> alimentare la instalatii CLASSIC.<br />

Pompare (Pumpenstoß)<br />

Intervalul <strong>de</strong> timp pentru pompariile care servesc alimentarii cu apa si a recircularii namolului<br />

in exces.<br />

Post operare (Nachlaufzeit)<br />

Stromgrenzen<br />

Beschicker1<br />

I= 5,0A ... 7,0A<br />

↓ ↑ EDIT ESC<br />

Protokoll RS232<br />

<br />

Pumpenstoß<br />

↓ ↑ OK ESC<br />

EDIT<br />

Edit<br />

Evacuarea este prelungita dupa atingerea nivelului minim Hwmin cu timpul setat, daca<br />

<strong>unitate</strong>a <strong>de</strong> epurare este prevazuta cu un plutitor AQUASwitch (BASIC).<br />

O comutare rapida dupa finalizarea procesului <strong>de</strong> evacuare este exclusa datorita histerezei<br />

mici a plutitorului.<br />

In<strong>de</strong>pen<strong>de</strong>nt <strong>de</strong> acestea la toate agregatele are loc o pauza <strong>de</strong> un minut intre sfarsitul si<br />

inceputul unui ciclu. Nici un agregat nu functioneaza in acest interval.<br />

Timpul <strong>de</strong> <strong>de</strong>clansare a <strong>de</strong>ranjamentelor (Fehlerauslösezeit)<br />

Stromgrenzen<br />

Beschicker1<br />

I= 05,0A ... 07,0A<br />

Pos Wert OK ESC<br />

La <strong>AQUAmax</strong>® PROFESSIONAL XL A/AA/AM aeratoarele resp. mixerele nu sunt comutate<br />

direct din <strong>ProControl</strong>.<br />

OK<br />

ESC<br />

ESC<br />

BechickungDeni<br />

Dauer<br />

=30 Sekun<strong>de</strong>n<br />

Edit ESC<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

24 / 42<br />

Edit<br />

OK<br />

ESC<br />

BechickungDeni<br />

Dauer<br />

= 30 Sekun<strong>de</strong>n<br />

Pos Wert Ok ESC


Cu iesirile Bel1 si Bel2 sunt coordonate releurile externe <strong>de</strong> siguranta. Acestea comuta<br />

sarcina pentru aerator, aeratorul resp. mixerul.<br />

Datorita faptului ca in acest caz nu este comutata direct sarcina, se <strong>de</strong>zactiveaza<br />

supravegherea tensiunii pentru iesirile Bel1 si Bel2. Alternativ se activeaza o alarmare<br />

externa.<br />

Alarmarea externa (potentialul N) la contactul 32 <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> poate distinge daca<br />

aeratorul 1 extern a cuplat. Prin alarmarea externa (potentialul N) la contactul 32 <strong>unitate</strong>a <strong>de</strong><br />

<strong>control</strong> poate distinge daca aeratorul 2 resp. mixerul a cuplat. (vezi pag. 35)<br />

Deregula alarmarea externa supravegheaza un automat <strong>de</strong> protectie pentru motor si un releu<br />

<strong>de</strong> siguranta.<br />

In stadiul comutat lantul <strong>de</strong> alarmare trebuie sa fie inchis. Daca lantul <strong>de</strong> alarmare este<br />

intrerupt in timpul functionarii aceasta duce la generarea unei alarme la sfarsitul timpului <strong>de</strong><br />

<strong>de</strong>clansare a <strong>de</strong>ranjamentelor.<br />

Protocol RS232 (Protokoll RS232)<br />

Fehlerauslösezeit<br />

< Protokoll RS232 ><br />

Beschickung Deni<br />

↓ ↑ OK ESC<br />

Jurnalul <strong>de</strong> functionare poate fi citit peste interfata RS232 aflata in panoul <strong>de</strong> <strong>control</strong>.<br />

Atentie! Nesesita cablu special. Cablurile normale pot <strong>de</strong>teriora <strong>unitate</strong>a <strong>de</strong><br />

<strong>control</strong>.<br />

Deregula interfata RS232 este libera. In cazuri speciale insa este necesara <strong>de</strong>cuplarea<br />

interfetei (tasta „Inaktiv”).<br />

Cu tasta „Info” sunt afisati parametrii setati ai interfetei.<br />

In cazul in care RS232 nu reactioneaza la comenzi se poate <strong>de</strong>puce faptul ca <strong>unitate</strong>a a fost<br />

scoasa din priza intr-un mod necorespunzator. (Software-Handshake). In cazul acesta<br />

interfata poate fi adusa din nou intr-un stadiu funcitonal apasand tasta „RST”. Datele care<br />

urmau sa fie prelucrate se intrerup.<br />

Setari din fabrica (Werkseinstellungen)<br />

Erwieterung<br />

<br />

Einfahren<br />

nein<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

Protokoll RS232<br />

aktiv<br />

inakt RST Info ESC<br />

inaktiv<br />

Protokol RS232<br />

inaktiv<br />

aktiv ESC<br />

OK<br />

ja<br />

nein<br />

Baudrate:19200<br />

Data Bits:8StopBit:1<br />

Parity:non<br />

beliebige Taste<br />

Prin intermediul tastei „ja” (da) sunt preluati parametrii corespunzatori statiei setate.<br />

Info<br />

aktiv RST<br />

Bitte wählen Sie<br />

Grun<strong>de</strong>instellungen<br />

ja nein<br />

Protokoll RS232<br />

Zurücksetzen…<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

25 / 42


Perioada <strong>de</strong> adaptare (Einfahren)<br />

Werkseinstellung<br />

< Einfahren ><br />

Phosphatfällung<br />

↓ ↑ OK ESC<br />

In primele saptamani <strong>de</strong> functionare a instalatiei <strong>de</strong> epurare trebuie sa se <strong>de</strong>zvolte mai intai<br />

namolul activ. In aceasta perioada nu are sens o evacuare a namolului in exces.<br />

Din acest motiv evacuarea namolului porneste doar dupa parcurgerea unui anumit numar <strong>de</strong><br />

cicluri. Setarea standard este <strong>de</strong> 270 <strong>de</strong> cicluri, ceea ce corespun<strong>de</strong>, la un ciclu <strong>de</strong> 8 ore,<br />

unei perioa<strong>de</strong> <strong>de</strong> timp <strong>de</strong> 90 <strong>de</strong> zile sau 3 luni.<br />

In acest meniu este indicat numarul <strong>de</strong> cicluri ramase pana cand este activata evacuarea<br />

namolului in exces.<br />

Cu „Edit” ajungeti in modul <strong>de</strong> setare. Cu „Pos” alegeti pozitia si cu „Wert” modificati valoarea<br />

pozitiei respective. CU „Ok” se salveaza setarile efectuate, cu „ESC” parasiti meniul fara a<br />

salva schimbarile.<br />

Precipitare fosfor (Phosphatfällung)<br />

Einfahren<br />

< Phosphatfällung ><br />

Dosierpumpe<br />

↓ ↑ OK ESC<br />

In acest meniu activati contacul fara potential 1 prevazut pentru precipitare fosfor. Peste<br />

acest contact poate fi dirijata o pompa <strong>de</strong> dozaj substanta floculanta.<br />

Dozajul se face in prima faza <strong>de</strong> aerare din ultima ora <strong>de</strong> tratare (1 ora inainte <strong>de</strong> faza <strong>de</strong><br />

sedimentare).<br />

Cu „OK” ajungeti in modul <strong>de</strong> setare, aici puteti activa sau <strong>de</strong>zactiva contactul apasand<br />

tastele corespunzatoare. Cu „ESC” parasiti meniul.<br />

ATENTIE! Contactul fara potential 1 poate fi utilizat pentru precipitare fosfor<br />

sau pentru <strong>de</strong>zinfectare cu UV. Odata cu activarea uneia dintre aceste variante<br />

va fi <strong>de</strong>zactivata cealalta (in cazul in care a fost activata)!<br />

ATENTIE! In cazul in care nu se utilizeaza un indicator al volumului <strong>de</strong><br />

umplere pentru substanta floculanta trebuie executat un pod electric <strong>de</strong><br />

legatura peste clemele 14 si 26 (vezi pag. 30).<br />

Pompa dozaj (Dosierpumpe)<br />

Phosphatfällung<br />

< Dosierpumpe ><br />

UV-Desinfektion<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

OK<br />

OK<br />

ESC<br />

ESC<br />

Einfahren<br />

Zähler<br />

= 263<br />

EDIT ESC<br />

Freigabe<br />

Phosphatfällung<br />

inaktiv<br />

aktiv ESC<br />

Dosierpumpe<br />

Einschaltdauer<br />

= 0 Sekun<strong>de</strong>n<br />

EDIT ESC<br />

EDIT<br />

Einfahren<br />

Zähler<br />

= 263<br />

Pos Wert OK ESC<br />

In acest meniu fixati timpul <strong>de</strong> dozaj al pompei activate in meniul anterior.<br />

Cu tasta „Edit” ajungeti in modul <strong>de</strong> setare. Cu „Pos” alegeti pozitia si cu „Wert” modificati<br />

valoarea pozitiei respective. Cu „Ok” se salveaza setarile efectuate, cu „ESC” parasiti meniul<br />

fara a salva schimbarile.<br />

Valorile presetate le gasiti in anexa.<br />

OK<br />

ESC<br />

aktiv<br />

inakt<br />

EDIT<br />

OK<br />

ESC<br />

Freigabe<br />

Phosphatfällung<br />

aktiv<br />

inakt ESC<br />

Dosierpumpe<br />

Einschaltdauer<br />

= 000 Sekun<strong>de</strong>n<br />

Pos Wert OK ESC<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

26 / 42


Dezinfectare UV (UV-Desinfektion)<br />

Dosierpumpe<br />

< UV-Desinfektion ><br />

Alarmkontakt<br />

↓ ↑ OK ESC<br />

OK<br />

ESC<br />

Cu activarea acestui meniu este pornita <strong>unitate</strong>a <strong>de</strong> ultraviolete pentru igienizarea apelor.<br />

Aceasta este pornita cu 5 min inainte <strong>de</strong> evacuarea apei si ramane activa alte 5 min dupa<br />

incheierea evacuarii. Cu „ESC” parasiti meniul.<br />

Durata <strong>de</strong> viata in medie a unei lampe UV este <strong>de</strong> 2.000 <strong>de</strong> cicluri sau 8.760 <strong>de</strong> ore. Aceasta<br />

corespun<strong>de</strong> unei perioa<strong>de</strong> <strong>de</strong> functionare in medie <strong>de</strong> 2 ani.<br />

Pe ecran sunt prezentate ciclurile <strong>de</strong> viata ramase. Dupa expirarea celor 2.000 <strong>de</strong> cicluri este<br />

generata o alarma (<strong>de</strong>ranjament 15 =Fehler 15).<br />

Pentru a anunta utilizatorul si serviciul <strong>de</strong> intretinere din timp in ceea ce priveste necesitatea<br />

schimbarii lampii UV este generata, dupa 1550 <strong>de</strong> cicluri (contor =450 [~ 150 <strong>de</strong> zile] o<br />

observatie pe ecranul unitatii<br />

Contorul <strong>de</strong> pe ecran poate fi resetat prin <strong>de</strong>zactivare si o noua activare dupa inlocuirea<br />

lampii UV (contor=2.000).<br />

Cu ESC parasiti meniul.<br />

UV-Desinfektion<br />

Freigabe = inaktiv<br />

aktiv ESC<br />

ATENTIE! Contactul fara potential 1 poate fi utilizat pentru precipitare fosfor<br />

sau pentru <strong>de</strong>zinfectare cu UV. Odata cu activarea uneia dintre aceste variante<br />

va fi <strong>de</strong>zactivata cealalta (in cazul in care a fost activata)!<br />

ACHTUNG! In cazul in care nu se utilizeaza un senzor pentru functionalitatea<br />

lampii UV trebuie executat un pod electric peste clemele14 si 26 (vezi pag. 30).<br />

Contactul fara potential (Alarmkontakt)<br />

Dosierpumpe OK Alarmkontakt<br />

< Alarmkontakt ><br />

nicht benutzt<br />

Service<br />

↓ ↑ OK ESC ESC EDIT ESC<br />

EDIT<br />

OK<br />

ESC<br />

In acest meniu activati contacul fara potential<br />

2 prevazut pentru <strong>de</strong>zinfectare UV. Peste<br />

acest contact poate fi dirijata o alarma externa.<br />

Cu tasta „Edit” ajungeti in modul <strong>de</strong> setare. Cu<br />

„Pos” alegeti pozitia si cu „Wert” modificati valoarea<br />

pozitiei respective. Cu „Ok” se salveaza<br />

setarile efectuate<br />

Cu ESC parasiti meniul.<br />

aktiv<br />

UV-Desinfektion<br />

inaktiv<br />

Freigabe = aktiv<br />

Zähler=2000(8760h)<br />

inaktiv RST ESC<br />

ESC<br />

Alarmkontakt<br />

nicht benutzt<br />

↓ ↑ OK ESC<br />

Alarmkontakt<br />

Schließer<br />

↓ ↑ OK ESC<br />

Alarmkontakt<br />

Öffner<br />

↓ ↑ OK ESC<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

27 / 42


Anexa date <strong>de</strong> operare<br />

Date si timpi <strong>de</strong> functionare preprogramati <strong>AQUAmax</strong>® PROFESSIONAL:<br />

Alimentare Denitrificare Mod op. normal Sedi-<br />

Evacuare Evacuare Clatire Mod econom Fosfor<br />

Tip Aerare Aerare mentare Aerare apa epurata namol Pompe Aerare Timp dozare<br />

Durata Pauza Dauer pornita oprita pornita oprita pornita oprita **<br />

[min] [h] [min] [sec] [min] [min] [min] [h] [h] [min] [sec] [sec] [min] [min] [sec]<br />

min/ma<br />

x* max 30 min 1,5 max 90 max 60 min 10 max 15 min 10 1 / 2 min 3 min 10 - 0,2 / 0,5 max 15 min 10 -<br />

G 02 0,4 3,2 41 15 10 2 15 1,5 6,4 20 2 0,2 2 15 3,6<br />

G 04 0,7 3,2 41 15 10 3 15 1,5 6,4 20 3 0,2 2 15 7,2<br />

G 06 1,1 3,2 42 15 10 4 15 1,5 6,4 20 5 0,2 2 15 10,8<br />

G 08 1,4 3,2 42 15 10 5 15 1,5 6,4 20 6 0,2 2 15 14,4<br />

G 10 1,8 3,2 42 15 10 6 15 1,5 6,4 20 8 0,2 3 15 18,0<br />

G 12 2,1 3,2 43 15 10 7 15 1,5 6,4 30 9 0,2 3 15 21,6<br />

G 16 2,8 3,2 43 15 10 6 15 1,5 6,4 40 12 0,2 4 15 28,8<br />

G 20 3,5 3,2 44 15 10 7 15 1,5 6,4 40 15 0,2 3 15 36,0<br />

G 24 4,2 3,2 45 15 10 8 15 1,5 6,4 50 18 0,2 4 15 43,2<br />

G 28 4,9 3,2 45 15 10 9 15 1,5 6,4 60 21 0,2 4 15 50,4<br />

G 32 5,6 3,2 46 15 10 11 15 1,5 6,4 20 10 0,2 5 15 57,6<br />

G 36 6,4 3,2 47 15 10 13 15 1,5 6,4 20 11 0,2 6 15 64,8<br />

G 40 7,1 3,2 48 15 10 14 15 1,5 6,4 20 12 0,2 7 15 72,0<br />

G 44 7,8 3,2 48 15 10 15 15 1,5 6,4 20 13 0,2 7 15 79,2<br />

G 48 8,5 3,2 49 15 10 15 13 1,5 6,4 30 14 0,2 8 15 86,4<br />

G 53 9,5 3,2 50 15 10 15<br />

1


Date si timpi <strong>de</strong> functionare preprogramati <strong>AQUAmax</strong>® CLASSIC / BASIC :<br />

Alimentare Denitrificare Mod op. normal<br />

Evacuare namol Clatire Mod econom Fosfor<br />

Sedi-<br />

Evacuare<br />

Tip BASIC CLASSIC Aerare Aerare mentare Aerare apa epurata BASIC CLASSIC Pompe Aerare Timp dozare<br />

Nr. Durata Pauza Dauer pornita oprita pornita oprita Nr. Durata pornita oprita **<br />

[sec] [h] [min] [sec] [min] [min] [min] [h] [h] [min] [sec] [sec] [min] [min] [sec]<br />

min/max* 4/9 4/30 1,5 / - - / 90 - / 60 10 / - 1 / 15 10 / - 1 / 2 3 / - 10 / 60 - 0,2 / 0,5 1 / 15 10 / - -<br />

2 5,0 7 2,0 41 15 10 2 15 2,0 6,0 20 1 2 0,2 2 15 3,6<br />

4 5,0 7 2,0 41 15 10 3 15 2,0 6,0 20 2 3 0,2 2 15 7,2<br />

6 5,0 7 2,0 42 15 10 4 15 2,0 6,0 20 3 5 0,2 2 15 10,8<br />

8 5,0 7 2,0 42 15 10 5 15 2,0 6,0 20 4 6 0,2 2 15 14,4<br />

10 5,0 7 2,0 42 15 10 6 15 2,0 6,0 20 5 8 0,2 3 15 18,0<br />

12 5,0 7 2,0 43 15 10 7 15 2,0 6,0 30 6 9 0,2 3 15 21,6<br />

14** 5,0 - 2,0 43 15 10 8 15 2,0 6,0 30 7 - 0,2 4 15 24,2<br />

16 5,0 7 2,0 43 15 10 8 15 2,0 6,0 40 8 12 0,2 4 15 28,8<br />

20 7 2,0 44 15 10 7 15 2,0 6,0 40 15 0,2 3 15 36<br />

24 7 2,0 45 15 10 8 15 2,0 6,0 50 18 0,2 4 15 43,2<br />

28 7 2,0 45 15 10 9 15 2,0 6,0 60 21 0,2 4 15 50,4<br />

32 7 2,0 46 15 10 11 15 2,0 6,0 20 10 0,2 5 15 57,6<br />

36 7 2,0 47 15 10 13 15 2,0 6,0 20 11 0,2 6 15 64,8<br />

40 7 2,0 48 15 10 14 15 2,0 6,0 20 12 0,2 7 15 72<br />

44 7 2,0 48 15 10 15 15 2,0 6,0 20 13 0,2 7 15 79,2<br />

48 7 2,0 49 15 10 15 13 2,0 6,0 30 14 0,2 8 15 86,4<br />

53 7 2,0 50 15 10 15 12 2,0 6,0 30 16 0,2 9 15 95,4<br />

* Valori setabile minime si maxime. ** doar BASIC<br />

Valori preprogramate pentru curentul electric <strong>AQUAmax</strong>® CLASSIC/BASIC:<br />

Tip Aerator 1 Aerator 2 Pompa alimentare 1 Pompa alimentare 2 Pompa evacuare 1 Pompa evacuare 2 Pompa namol<br />

[A] [A] [A] [A] [A] [A] [A]<br />

2<br />

4<br />

6<br />

8<br />

10<br />

12<br />

14<br />

16<br />

20<br />

24<br />

28<br />

32<br />

36<br />

40<br />

44<br />

48<br />

53<br />

0,7...1,9<br />

1,5...3,8**<br />

0,0...10,0 0,0...10,0 0,0...10,0<br />

0,4...1,2<br />

0,7…1,9**<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

29 / 42<br />

0,0...10,0<br />

0,0…10,0*<br />

0,4…1,2**<br />

0,7…1,9**


Semnalizarea <strong>de</strong>ranjamentelor (Mögliche Fehlermeldungen):<br />

ATENTIE! Alarma acustica si cea externa (daca cuplata la contactul fara<br />

potential) sunt oprite prin apasarea unei taste oarecare. Deranajmentul<br />

ramane insa indicat in display pana la resetare (Fehler-Reset). Dupa resetare<br />

<strong>de</strong>ranjamentul mai poate fi regasit doar in jurnalul electronic.<br />

La o noua aparitie a aceluiasi <strong>de</strong>ranjament acesta nu va mai fi indicat inca o data, daca<br />

nu efectuati o resetare a <strong>de</strong>ranjamentului. Pentru a garanta o operare optima si sigura,<br />

este obligatorie resetarea <strong>de</strong>ranjametului dupa receptionare (aceasta insemnand: Alle Fehler<br />

löschen? = ja = Stergeti toate <strong>de</strong>ranjamentele? = da). O resetare automata are loc dupa 72<br />

<strong>de</strong> ore.<br />

O resetare este trecuta in jurnalul electronic cu textul „inaktiv”. Dupa informarea firmei <strong>de</strong><br />

intretinere aceasta va lua masurile necesare pentru remedierea <strong>de</strong>ranjamentului.<br />

UVS (alarma acustica, fara indicare in display)<br />

UVS (Un<strong>de</strong>r Voltage Signaling / Semnalizare ca<strong>de</strong>re tensiune) este o componenta<br />

electronica integrata in <strong>unitate</strong>a <strong>de</strong> <strong>control</strong>. In cazul intreruperii curentului spre <strong>unitate</strong>a <strong>de</strong><br />

<strong>control</strong> si astfel spre instalatie, din cauza unei sigurante sau a ca<strong>de</strong>rii <strong>de</strong> tensiune, este<br />

<strong>de</strong>clansat un semnal acustic. Odata activat, acest semnal persista pentru cca. 24 <strong>de</strong> ore.<br />

Alarma se receptioneaza apasand o tasta oarecare. Alarma se <strong>de</strong>zactiveaza automat in<br />

momentul in care este din nou tensiune.<br />

Dupa o ca<strong>de</strong>re <strong>de</strong> tensiune (chiar si <strong>de</strong> scurta durata) si revenire a acesteia, perioada <strong>de</strong><br />

timp pana este reactivat semnalul UVS este <strong>de</strong> 4 ore.<br />

Unitate <strong>de</strong> <strong>control</strong> nefunctionala (nici o imagine pe ecran)<br />

Siguranta arsa. (inlocuiti siguranta cu cea <strong>de</strong> rezerva din capacul unitatii <strong>de</strong> <strong>control</strong>)<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

30 / 42


Text indicat in display (alarma acustica)<br />

Fehler [ 0]<br />

Belüfter1<br />

Strom Min.<br />

Quitt...<br />

Fehler [ 4]<br />

Klarwasserpumpe1<br />

Strom Min.<br />

Quitt...<br />

Cauza posibila<br />

Un agregat sau statia <strong>AQUAmax</strong>® nu sunt<br />

racordate.<br />

Una (sau toate) din legaturile <strong>de</strong> curent nu a<br />

fost bine efectuata, astfel incat se produc<br />

intreruperi.<br />

Cablul <strong>de</strong> legatura dintre aparatul electric si<br />

<strong>unitate</strong>a <strong>de</strong> <strong>control</strong> este intrerupt<br />

Siguranta din <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> a<br />

agregatului respectiv a sarit.<br />

Nivelul apei in bazin(e) este asa <strong>de</strong> scazut<br />

incat instalatia este uscata. Eventual sa<br />

efectuat vidanjarea si bazinele nu au fost<br />

reumplute.<br />

Agregatul corespunzator este <strong>de</strong>fect.<br />

Fehler [ 0]<br />

Belüfter1<br />

Strom Max.<br />

Quitt...<br />

Fehler [ 4]<br />

Klarwasserpumpe1<br />

Strom Max.<br />

Quitt...<br />

Cauza posibila<br />

Fehler [ 1]<br />

Belüfter2<br />

Strom Min.<br />

Quitt...<br />

Fehler [ 5]<br />

Klarwasserpumpe2<br />

Strom Min.<br />

Quitt...<br />

Fehler [ 1]<br />

Belüfter2<br />

Strom Max.<br />

Quitt...<br />

Fehler [ 5]<br />

Klarwasserpumpe2<br />

Strom Max.<br />

Quitt...<br />

Agregatul respectiv este infundat sau blocat<br />

sau se invarte greu.<br />

Fehler [ 2]<br />

Beschicker1<br />

Strom Min.<br />

Quitt...<br />

Fehler [ 6]<br />

Schlammpumpe<br />

Strom Min.<br />

Quitt...<br />

Remediere<br />

Conectati agregatul corespunzator.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

31 / 42<br />

Chemati firma <strong>de</strong> service sau lasati un<br />

electrician sa <strong>control</strong>eze cablul respectiv.<br />

Vezi mai sus.<br />

Schimbati siguranta. (Siguranta <strong>de</strong> rezerva in<br />

capac)<br />

Controlati nivelul apei. Umpleti instalatia cu<br />

apa. Controlati plutitoarele <strong>de</strong> comutare.<br />

Chemati firma <strong>de</strong> service.<br />

Fehler [ 2]<br />

Beschicker1<br />

Strom Max.<br />

Quitt...<br />

Fehler [ 6]<br />

Schlammpumpe<br />

Strom Max.<br />

Quitt...<br />

Remediere<br />

Fehler [ 3]<br />

Beschicker2<br />

Strom Min.<br />

Quitt...<br />

Fehler [ 3]<br />

Beschicker2<br />

Strom Max.<br />

Quitt...<br />

Scoateti instalatia din bazin si curatati /<br />

<strong>de</strong>sfundati agregatul.<br />

ATENTIE! Piese rotative! Deconectati instalatia <strong>de</strong> la sursa <strong>de</strong> curent inainte <strong>de</strong> a o<br />

extrage din bazin!


Fehler [ 7]<br />

Schwimmer Reaktor<br />

<strong>de</strong>fekt<br />

Quitt...<br />

Greseala logica. Plutitorul <strong>de</strong> sus inchi<strong>de</strong> si cel <strong>de</strong> jos este inca <strong>de</strong>schis (atentie la statutul<br />

plutitoarelor indicat in display)<br />

Cauza posibila<br />

Remediere<br />

Plutitorul este <strong>de</strong>fect sau este intrerupt cablul Chemati firma <strong>de</strong> service.<br />

<strong>de</strong> alimentare.<br />

Plutitorul s-a blocat si nu se ridica. Controlati plutitorul, acesta nu are voie sa se<br />

agate.<br />

Una (sau toate) din legaturile <strong>de</strong> curent nu a Chemati firma <strong>de</strong> service sau lasati un<br />

fost bine efectuata, astfel incat se produc electrician sa <strong>control</strong>eze cablul respectiv.<br />

intreruperi.<br />

Fehler [ 9]<br />

Klarwasserabzug<br />

Zeitüberschreitung<br />

Quitt...<br />

Fehler [ 8]<br />

Schwimmer Puffer<br />

<strong>de</strong>fekt<br />

Quitt...<br />

Fehlern (9) = Evacuarea apei epurate dureaza mai mult <strong>de</strong>cat timpul maxim setat. Plutitorul<br />

<strong>de</strong> jos din bazinul SBR [SW1] nu ca<strong>de</strong> (Atentie la statutul plutitoarelor indicat in display).<br />

Cauza posibila Remediere<br />

Plutitorul [SW1] este <strong>de</strong>fect. Chemati firma <strong>de</strong> service.<br />

Plutitorul [SW1] este blocat. Controlati plutitorul, acesta nu are voie sa se<br />

O legatura in panoul electric nu a fost facuta<br />

corect. Eventual nu este bine strans un surub<br />

si cablul nu face contact sau este intrerupt.<br />

agate.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

32 / 42<br />

Chemati firma <strong>de</strong> service sau lasati un<br />

electrician sa <strong>control</strong>eze cablul respectiv.<br />

Cablul <strong>de</strong> legatura este intrerupt. Vezi mai sus.<br />

Pompa <strong>de</strong> evacuare nu are <strong>de</strong>bit suficient. Controlati <strong>de</strong>bitul pompei trecand in modul <strong>de</strong><br />

operare manual. Evt. trebuie curatata pompa.<br />

Daca trebuie schimbata, chemati firma <strong>de</strong><br />

Neetanseitati in conducta <strong>de</strong> evacuare.<br />

Conducta <strong>de</strong> evacuare nu este fixata<br />

corespunzator la pompa.<br />

service.<br />

Schimbati conducta. Fixati conducta <strong>de</strong><br />

evacuare corespunzator.<br />

Apa curge inapoi in instalatie. Controlati evacuarea. In<strong>de</strong>partati cauza<br />

infundarii.<br />

Nivelul <strong>de</strong> apa in bazinul <strong>de</strong> tratare este Controlati rezervorul. Acesta trebuie sa fie<br />

ridicat. In instalatie ajunge mai multa apa sau etans. Constatati <strong>de</strong> un<strong>de</strong> vine surplusul <strong>de</strong><br />

nu este etans rezervorul.<br />

apa.<br />

Valoarea setata pentru timpul <strong>de</strong> evacuare Corectati valoarea. Ridicati timpul <strong>de</strong><br />

este falsa.<br />

evacuare.


Fehler [10]<br />

Hochwasser<br />

max. Niveau<br />

Quitt...<br />

Fehler (10) = Inundatie; Volumul maxim in bazinul <strong>de</strong> stocare este atins. Plutitorul <strong>de</strong> sus<br />

[SW4] a inchis. Volumul maxim in bazinul <strong>de</strong> tratare este atins (SW2 a inchis). Atentie la<br />

indicatorul plutitoarelor in display.<br />

Cauza posibila<br />

Remediere<br />

Apa curge inapoi in instalatie. Controlati evacuarea. In<strong>de</strong>partati cauza<br />

infundarii.<br />

In instalatie ajunge mai multa apa sau nu Controlati rezervorul. Acesta trebuie sa fie<br />

este etans rezervorul.<br />

etans. Constatati <strong>de</strong> un<strong>de</strong> vine surplusul <strong>de</strong><br />

apa.<br />

Bazinul <strong>de</strong> stocare este dimensionat prea Instalati un bazin <strong>de</strong> stocare suplimentar.<br />

mic.<br />

Fehler [11]<br />

max. 7Beschickung<br />

uberschritten<br />

Quitt...<br />

Plutitorul <strong>de</strong> jos din bazinul SBR (SW1) nu s-a activat nici dupa faza a saptea a alimentarii.<br />

Cauza posibila<br />

Remediere<br />

Pompa <strong>de</strong> alimentare <strong>de</strong>fecta. Controlati pompa si in caz <strong>de</strong> necesitate<br />

inlocuiti-o.<br />

Plutitorul SW1 sau SW3 este <strong>de</strong>fect respectiv Verificati plutitoarele si inlaturati cauza<br />

blocat.<br />

blocajului sau in caz <strong>de</strong> necesitate inlocuti<br />

plutitorii.<br />

Teava <strong>de</strong> alimentate este intrerupta sau<br />

infundata.<br />

Desfundati teava.<br />

Timpii <strong>de</strong> alimentare sunt prea scurti. Corectati setarile pentru timpii <strong>de</strong> alimentare.<br />

Fehler [12]<br />

Fällmittel<br />

Quitt...<br />

Fehler (12) = In cazul in care se foloseste <strong>unitate</strong>a <strong>de</strong> precipitare fosfor: Nivelul minim in<br />

recipientul cu substanta floculanta este atins.<br />

Cauza posibila<br />

Remediere<br />

Substanta floculanta a fost epuizata. Umpleti sau schimbati recipientul.<br />

O legatura in panoul electric nu a fost facuta<br />

corect. Eventual nu este bine strans un surub<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

33 / 42<br />

ATENTIE! Daca nu este montat un<br />

indicator <strong>de</strong> nivel, atunci peste clemele<br />

14 si 26 (V-/P) trebuie executat un pod<br />

electric <strong>de</strong> legatura.<br />

Chemati firma <strong>de</strong> service sau lasati un<br />

electrician sa <strong>control</strong>eze cablul respectiv.


si cablul nu face contact sau este intrerupt.<br />

Fehler [13]<br />

12V-Versorgung<br />

Quitt...<br />

Fehler (13) = Sursa interna <strong>de</strong> 12V (plutitoare) este <strong>de</strong>fecta.<br />

Cauza posibila<br />

Sursa interna <strong>de</strong> 12V (plutitoare) este<br />

<strong>de</strong>fecta.<br />

Fehler [14]<br />

UV-Lampe <strong>de</strong>fekt<br />

Quitt...<br />

Fehler (14) = Lampa <strong>de</strong> ultraviolete este <strong>de</strong>fecta<br />

Cauza posibila<br />

Remediere<br />

Chemati firma <strong>de</strong> service.<br />

Remediere<br />

Cablul <strong>de</strong> legatura este intrerupt. Chemati firma <strong>de</strong> service sau lasati un<br />

electrician sa verifice contactii si cablurile.<br />

Contactul <strong>de</strong> atentionare <strong>de</strong>ranjament indica Chemati firma <strong>de</strong> service.<br />

(Lampensensor- senzorul lampii)<br />

Fehler [15]<br />

UV-Lampe Service<br />

Quitt...<br />

Fehler (15) = Lampa <strong>de</strong> ultraviolete a atins numarul maxim <strong>de</strong> utilizari.<br />

Cauza posibila<br />

S-a atins numarul maxim <strong>de</strong> utilizari al lampii<br />

UV<br />

Remediere<br />

Chemati firma <strong>de</strong> service.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

34 / 42<br />

ATENTIE! Daca nu este montat un senzor<br />

pentru functionalitatea lampii UV, atunci<br />

peste clemele 14 si 26 (V-/P) trebuie<br />

executat un pod electric <strong>de</strong> legatura.


Date tehnice:<br />

Carcasa: IP65, 280x220x80 mm<br />

Interval temperatura: -10°C ... +50°C<br />

Tensiune operare: 185...245V, 50...60Hz<br />

Putere la sursa: < 25 VA<br />

Putere max. racord iesire: 1.400 VA<br />

Putere max. totala: 3.500 VA<br />

Contacte fara potential: 230 V~ / 8 A / 1.500 VA<br />

Releu <strong>de</strong> raportare (RR1...RR4): 200 V ~ / 0,5 A / 10 W<br />

Tensiune <strong>de</strong> iesire V+/V-: 5 V / 0,2 A<br />

Iesire analoga AO/Gnd: 0...10 V<br />

Intrare analoga AI/Gnd: 0...10 V<br />

Acumulator: NiMH, 4.8V, 80mAH; Durata <strong>de</strong> viata: 1000 Incarcari / Descarcari<br />

Sub tensiune: min. 6 ani |25°<br />

Sub tensiune: min. 3 ani |45°<br />

Platina<br />

Siguranta <strong>unitate</strong><br />

TR5; T0,63A<br />

Siguranta pt. agregate<br />

5x20; T6,3A<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

35 / 42<br />

- Clemele 34-36 (N01/C01/NC1):<br />

contact fara potential 1 (Pompa<br />

dozaj substanta floculanta sau<br />

lampa UV)<br />

- Clemele.14/26 (V-/P): Nivel<br />

substanta floculanta sau<br />

senzorul lampii UV (daca nu<br />

este disponibil executare pod!)<br />

- Clemele 22-24 (N02/C02/NC2):<br />

Contact fara potential 2<br />

(Alarma)<br />

Clemeke 32-33: alarma externa<br />

aerator 1 / mixer (33) la<br />

PROFESSIONAL XL A/AA/AM<br />

[comutati inspre zero (N)!]<br />

ATENTIE! Intrerupeti curentul electric catre <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> inainte <strong>de</strong> a o<br />

<strong>de</strong>schi<strong>de</strong>. Lucrarile la <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> sub tensiune se vor executa doar <strong>de</strong><br />

un electrican calificat!


Semnalizarea aprofundata a <strong>de</strong>ranjamentelor:<br />

Unitatea proControl® <strong>de</strong>tine 4 releuri tip Reed (inchizatoare) pentru transmiterea <strong>de</strong>ranjamentelor<br />

la distanta. Acestea sunt folosite pentru transmiterea <strong>de</strong>ranjamentelor cu ajutorul<br />

unui mo<strong>de</strong>m - GSM (SMS sau E-mail).<br />

Contactele sunt inchise in modul normal, adica cand nu sunt <strong>de</strong>ranjamente. Fara tensiune<br />

(d.ex. la ca<strong>de</strong>rea tensiunii) sunt toate contactele <strong>de</strong>schise. Cu aceste 4 contacte este<br />

posibila semnalizarea a 16 statute diferite. (prezentare binara)<br />

Blocul <strong>de</strong> cleme<br />

Statuturi posibile pentru releurile-Reed<br />

Dez.-<br />

Cod<br />

Hex-<br />

Cod<br />

Cod binar<br />

RR4 RR3 RR2 RR1<br />

Descriere<br />

0 0x00 0 0 0 0 Ca<strong>de</strong>re tensiune (Unitatea <strong>de</strong> <strong>control</strong> oprita)<br />

1 0x01 0 0 0 1 Aerator 1 <strong>de</strong>fect (extern)<br />

2 0x02 0 0 1 0 Aerator 2 resp. mixer <strong>de</strong>fect (daca este montat)<br />

3 0x03 0 0 1 1 Pompa evacuare 1 <strong>de</strong>fecta<br />

4 0x04 0 1 0 0 Pompa evacuare 2 <strong>de</strong>fecta (daca este montata)<br />

5 0x05 0 1 0 1 Pompa alimentare 1 <strong>de</strong>fecta<br />

6 0x06 0 1 1 0 Pompa alimentare 2 <strong>de</strong>fecta (daca este montata)<br />

7 0x07 0 1 1 1 Pompa <strong>de</strong> namol <strong>de</strong>fecta<br />

8 0x08 1 0 0 0 Inundatie (toate 4 plutitoarele sunt sus)<br />

9 0x09 1 0 0 1 Depasire timp pentru pompa <strong>de</strong> evacuare<br />

10 0x0A 1 0 1 0<br />

Defectiune plutitoare (ordine <strong>de</strong> cuplare, greseala<br />

logica)<br />

11 0x0B 1 0 1 1 Sursa <strong>de</strong> 12V este <strong>de</strong>fecta<br />

12 0x0C 1 1 0 0 Numarul maxim <strong>de</strong> alimentari a fost <strong>de</strong>pasit<br />

13 0x0D 1 1 0 1 Intervalul <strong>de</strong> service a expirat<br />

14 0x0E 1 1 1 0 Nivel substanta floculanta sau <strong>de</strong>fectiune lampa UV.<br />

15 0x0F 1 1 1 1<br />

Nici un <strong>de</strong>ranjament / Unitatea <strong>de</strong> <strong>control</strong> functioneaza<br />

normal.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

36 / 42<br />

RR1 (Clemele 20/21)<br />

Releuri-Reed 1<br />

RR2 (Clemele 18/19)<br />

Releuri- Reed 2<br />

RR3 (Clemele 16/17)<br />

Releuri- Reed 3<br />

RR4 (Clemele 1/2)<br />

Releuri- Reed 4<br />

Q (Clema 25)<br />

receptionare externa<br />

V- (Clemele 14 sau 15<br />

tensiune pentru<br />

receptionare externa<br />

Sectiune max. cabluri 0,5<br />

mm 2


Standard sunt toate contactele releurilor Reed inchise. Este indicate imaginea standard <strong>de</strong><br />

statut. (In tabelul <strong>de</strong> mai sus un 1 inseamna ca releul respectiv este inchis. Un 0 inseama ca,<br />

contactul respectiv este <strong>de</strong>schis).<br />

La aparitia unuia sau a mai multor <strong>de</strong>ranjamente care nu au fost receptionate este indicat in<br />

display doar <strong>de</strong>ranjamentul cu numarul <strong>de</strong> ordine cel mai mic [0…14]. In plus este activat<br />

semnalul acustic. Statutul instalatiei nu mai este indicat in display. Simultan se schimba si<br />

statutul releurilor Reed.<br />

ATENTIE! Doar daca s-a setat in lista <strong>de</strong>ranjamentelor (Service-Mo<strong>de</strong>) prioritatea 3<br />

(valoarea standard) pentru un <strong>de</strong>ranjament anume, atunci acesta este semnalat<br />

prin intermediul releului Reed.<br />

In cazul in care <strong>de</strong>ranjamentele nu sunt resetate, releurile <strong>de</strong> semnalizare indica<br />

doar <strong>de</strong>ranjamentul cu numarul cel mai mic.<br />

Deranjamentele care apar in modul <strong>de</strong> operare manual sunt indicate doar in display.<br />

Daca este setata prioritatea corespunzatoare atunci <strong>de</strong>ranjamentul este insotit si <strong>de</strong><br />

un semnal acustic. Releurile <strong>de</strong> semanlizare si contactul fara potential pentru<br />

alarma externa nu semnalizeaza in nici un caz, indiferent <strong>de</strong> prioritatea setata,<br />

<strong>de</strong>ranjamentele care apar in modul <strong>de</strong> operare manual.<br />

Deranjamentul sau <strong>de</strong>ranjamentele pot fi receptionate la fata locului prin apasarea unei taste<br />

oarecare sau <strong>de</strong> la distanta prin semnal extern (d.e. mo<strong>de</strong>m GSM). Pentru receptionarea <strong>de</strong><br />

la distanta (ex. Mo<strong>de</strong>m GSM) trebuie cuplat semnalul <strong>de</strong> la clema V- (clemele 14 sau 15) cu<br />

intrarea Q (25) (contact fara potential).<br />

In cazul in care nu apare un <strong>de</strong>ranjament cu o prioritate secundara, se opreste semnalul<br />

acustic. Daca toate alarmele au fost receptionate, atunci in display apare statutul instalatiei.<br />

Acesta alterneaza cu indicarea <strong>de</strong>ranjamentelor receptionate.<br />

ATENTIE! Deranjamentele receptionate pot fi resetate doar <strong>de</strong> la <strong>unitate</strong>a <strong>de</strong><br />

<strong>control</strong> !<br />

Acelasi <strong>de</strong>ranjament este doar atunci inca o data indicat, daca a fost<br />

efectuata resetarea inainte sau daca apare dupa el un <strong>de</strong>ranjament cu numar<br />

<strong>de</strong> ordine mai mare!<br />

Resetarea automata are loc doar dupa 72 <strong>de</strong> ore.<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

37 / 42


In<strong>de</strong>x alfabetic <strong>unitate</strong> <strong>de</strong> <strong>control</strong> (Germana-Romana)<br />

Text in display<br />

Absetzen Dauer : Durata sedimentare<br />

Aktiv : Activ (contact sau meniu activat)<br />

Alle Fehler löschen? : In<strong>de</strong>partati toate <strong>de</strong>ranjamentele (resetare)<br />

An : Pornit<br />

Aus : Oprit<br />

Beliebige Taste : Tasta (buton) oarecare<br />

Belüften : Aerare<br />

Belüfter 1...x : Aerator 1...x<br />

Belüftungsphase Dauer : Durata faza aerare<br />

Beschickung : Alimentare, umplere<br />

Betriebszähler : Contor timp <strong>de</strong> functionare<br />

Bitte Co<strong>de</strong> eingeben : Setati codul <strong>de</strong> acces<br />

Bitte wählen Sie Anlagengröße : Alegeti marimea instalatiei<br />

Bitte wählen Sie die Seriennummer : Setati numarul <strong>de</strong> serie<br />

Datum : Data<br />

Datum / Uhr stellen : Fixati data si ora<br />

Dauer : Durata<br />

Denitrifikation Belüftung aus : Denitrificare aerare oprita<br />

Denitrifikation Belüftung ein : Denitrificare aerare pornita<br />

Denitrifikation Dauer : Durata <strong>de</strong>nitrificare<br />

Dosierpumpe : Pompa <strong>de</strong> dozaj<br />

Dosierpumpe Einschaltdauer : Durata <strong>de</strong> functionare pompa <strong>de</strong> dozaj<br />

Einfahren : Perioada <strong>de</strong> adaptare<br />

Einstellungen : Setari<br />

Fällmittel : Substanta floculanta<br />

Fehler (0...15) : Deranjament (0...15)<br />

Fehlerliste : Lista <strong>de</strong>ranjamentelor<br />

Fehler-Reset : Resetare <strong>de</strong>ranjamente<br />

Freigabe : Acitvare (liber <strong>de</strong> operare)<br />

Freigabe Phosphatfällung : Activare precipitare fosfor<br />

Freigabe UV-Desinfektion : Acitvare lampa <strong>de</strong> ultraviolete<br />

Grun<strong>de</strong>instellungen korrekt : Setarile <strong>de</strong> baza corecte?<br />

Hand-Modus : Modul manual <strong>de</strong> operare<br />

Hochwasser : Inundatie<br />

Inaktiv : Inactiv<br />

Info : Informatii <strong>de</strong>spre instalatie (tip, marime)<br />

Ja : Da<br />

kein Datum : Nu este data<br />

Klarwasserabzug Dauer : Durata evacuare apa epurata<br />

Depasire durata timp setata pt. evacuare apa<br />

Klarwasserabzug Zeitüberschreitung : epurata<br />

Klarwasserpumpe : Pompa evacuare apa epurata<br />

Logbuch : Jurnal electronic<br />

max. Niveau : Nivel maxim<br />

Meldung : Raport<br />

Nein : Nu<br />

Nicht benutzt : NU este folosit<br />

Normalbetr. : Operare normala<br />

Normalbetrieb Belüftung aus : Operare normala aerare oprita<br />

Normalbetrieb Belüftung ein : Operare normala aerare pornita<br />

Öffner : Deschizator<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

38 / 42


Pause : Pauza<br />

Phosphatfällung : Precipitare fosfor<br />

pot. Kontakt : contact fara potential<br />

Priorität : Prioritate<br />

Quitt... : Receptionare<br />

Schlammabzug Dauer : Durata evacuare namol in exces<br />

Schlammpumpe : Pompa <strong>de</strong> namol<br />

Schließer : Inchizator<br />

Schwimmer : Plutitor<br />

Schwimmer Puffer : Plutitor bazinul <strong>de</strong> stocare<br />

Schwimmer Reaktor : Plutitor bazinul <strong>de</strong> tratare<br />

Schwimmerschalter : Plutitor comutator (Flotor)<br />

Service Mo<strong>de</strong> : Modul <strong>de</strong> service (acces firma montatoare)<br />

Sparmodus Belüftung aus : Modul econom aerarea oprita<br />

Sprache wählen : Alegeti limbajul dorit<br />

Spülung Pumpen : Clatire pompe<br />

Strom max. : Curent maxim<br />

Strom min. : Curent minim<br />

Stromgrenzen : Valori granita pentru curent<br />

Tageswert : Valoarea zilnica (contor)<br />

Testlauf : Testul agregatelor<br />

Uhrzeit : Ora<br />

UV-Desinfektion : Dezinfectare cu ultraviolete<br />

UV-Lampe <strong>de</strong>fekt : Lampa <strong>de</strong> UV este <strong>de</strong>fecta<br />

Zähler : Contor<br />

12V-Versorgung : Sursa <strong>de</strong> 12V (pt. Plutitoare)<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

39 / 42


In<strong>de</strong>x alfabetic <strong>unitate</strong> <strong>de</strong> <strong>control</strong> (Engleza-Romana)<br />

Text in display<br />

Duration of sedimentation : Durata sedimentare<br />

Activ : Activ (contact sau meniu activat)<br />

Delete all errors? : In<strong>de</strong>partati toate <strong>de</strong>ranjamentele (resetare)<br />

On : Pornit<br />

Off : Oprit<br />

Any key : Tasta (buton) oarecare<br />

Aerator : Aerator<br />

Aerator 1...x : Aerator 1...x<br />

Duration of aeration phase : Durata faza aerare<br />

Feeding : Alimentare, umplere<br />

Run-time meter : Contor timp <strong>de</strong> functionare<br />

Please enter co<strong>de</strong> : Setati codul <strong>de</strong> acces<br />

Please select plant size : Alegeti marimea instalatiei<br />

Please select serial number : Setati numarul <strong>de</strong> serie<br />

Date : Data<br />

Date / time : Fixati data si ora<br />

Duration : Durata<br />

Denitrification aeration OFF : Denitrificare aerare oprita<br />

Denitrification aeration ON : Denitrificare aerare pornita<br />

Duration of <strong>de</strong>nitrification : Durata <strong>de</strong>nitrificare<br />

Dosing pump : Pompa <strong>de</strong> dozaj<br />

Dosing pump runtime : Durata <strong>de</strong> functionare pompa <strong>de</strong> dozaj<br />

Run-up : Perioada <strong>de</strong> adaptare<br />

Settings : Setari<br />

Coagulant : Substanta floculanta<br />

Error (0...15) : Deranjament (0...15)<br />

Error list : Lista <strong>de</strong>ranjamentelor<br />

Error-Reset : Resetare <strong>de</strong>ranjamente<br />

Activation : Acitvare (liber <strong>de</strong> operare)<br />

Activation phosphate coagulation : Activare precipitare fosfor<br />

Activation UV-Desinfection : Acitvare lampa <strong>de</strong> ultraviolete<br />

Main settings correct? : Setarile <strong>de</strong> baza corecte?<br />

<strong>Manual</strong> mo<strong>de</strong> : Modul manual <strong>de</strong> operare<br />

High water operation : Inundatie<br />

In Or<strong>de</strong>r : Inactiv<br />

Info : Informatii <strong>de</strong>spre instalatie (tip, marime)<br />

Yes : Da<br />

no Date : Nu este data<br />

Discharge of clarified water duration : Durata evacuare apa epurata<br />

Depasire durata timp setata pt. evacuare apa<br />

Discharge of clarified water excee<strong>de</strong>d time limit : epurata<br />

Clarified water pump : Pompa evacuare apa epurata<br />

Logbook : Jurnal electronic<br />

max. Niveau : Nivel maxim<br />

Message : Raport<br />

No : Nu<br />

Not in use : NU este folosit<br />

Normal operation. : Operare normala<br />

Normal operation aeration OFF : Operare normala aerare oprita<br />

Normal operation aeration ON : Operare normala aerare pornita<br />

Normally open : Deschizator<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

40 / 42


Brake : Pauza<br />

Phosphate coagulation : Precipitare fosfor<br />

Potential-free contact : contact fara potential<br />

Priority : Prioritate<br />

Quitt : Receptionare<br />

Duration of sludge removal : Durata evacuare namol in exces<br />

Sludg pump : Pompa <strong>de</strong> namol<br />

Normally closed : Inchizator<br />

Float swich : Plutitor<br />

Float swich buffer : Plutitor bazinul <strong>de</strong> stocare<br />

Float swich reactor : Plutitor bazinul <strong>de</strong> tratare<br />

Float swich : Plutitor comutator (Flotor)<br />

Service Mo<strong>de</strong> : Modul <strong>de</strong> service (acces firma montatoare)<br />

Economic mo<strong>de</strong> aeration OFF : Modul econom aerarea oprita<br />

Select language : Alegeti limbajul dorit<br />

Flushing of pumps : Clatire pompe<br />

Max current : Curent maxim<br />

Min. current : Curent minim<br />

Current limits : Valori granita pentru curent<br />

Daily value : Valoarea zilnica (contor)<br />

Operation test : Testul agregatelor<br />

Time : Ora<br />

UV-Desinfection : Dezinfectare cu ultraviolete<br />

UV-Lamp out of or<strong>de</strong>r : Lampa <strong>de</strong> UV este <strong>de</strong>fecta<br />

Counter : Contor<br />

12V-DC supply : Sursa <strong>de</strong> 12V (pt. Plutitoare)<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

41 / 42


Declaratia <strong>de</strong> conformitate<br />

Producatorul: ATB Umwelttechnologien GmbH<br />

Südstr. 2<br />

D-32457 Porta Westfalica<br />

Declara prin prezenta ca utilajul <strong>de</strong>scris<br />

alaturat<br />

Unitate <strong>de</strong> <strong>control</strong> proControl ©<br />

In<strong>de</strong>plineste cerintele referitor la siguranta<br />

si sanatatea la utilizare a urmatoarelor<br />

normative europene:<br />

Norme armonizate aplicate:<br />

DIN EN 1050<br />

DIN EN 61000-6-4<br />

DIN EN 61000-6-1<br />

DIN EN 61000-3-2<br />

BGV A3<br />

DIN VDE 0100<br />

DIN VDE 0660<br />

DIN EN 61000-6-2<br />

DIN EN 55011<br />

ATB Umwelttechnologien Romania SRL<br />

Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />

42 / 42<br />

89/336/EEC Agreabilitate<br />

electromagnetica<br />

73/23/EEC Directiva pentru<br />

tensiuni joase<br />

Evaluarea riscurilor<br />

Agreabilitatea electromagnetica (EMC)<br />

Norme tehnice <strong>de</strong> baza<br />

Norme nationale aplicate si specificatii tehnice:<br />

9.GPSGV<br />

Directiva nr. 9 referitor la siguranta<br />

aparatelor<br />

Instalatii electrice si utilitati<br />

Constructia instalatiilor electrice cu tensiune<br />

pana in 1000 V<br />

Aparate <strong>de</strong> comutare la tensiune joasa<br />

Modificari constructive, care au repercursiuni asupra datelor tehnice <strong>de</strong>scrise<br />

in manualul <strong>de</strong> utilizare si a utilizarii corespunzatoare, care modifica masina<br />

substantial duc la anularea acestei <strong>de</strong>claratii <strong>de</strong> conformitate!<br />

Porta Westfalica, <strong>de</strong>n 15.05.2008<br />

Markus Baumann (Geschäftsführer)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!