proControl ©<br />
Unitate <strong>de</strong> <strong>control</strong> pentru <strong>AQUAmax</strong> ® BASIC/CLASSIC si PROFESSIONAL<br />
G/XL<br />
Instructiune <strong>de</strong> conectare si utilizare<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
1 / 42
INDEX<br />
Observatii generale si <strong>de</strong> siguranta 3<br />
Caracteristici ale echipamentului 3<br />
Montaj 4<br />
Principiul <strong>de</strong> functionare 6<br />
CLASSIC / BASIC 5<br />
PROFESSIONAL 6<br />
Functionare in cazul inundatilor 8 (doar Professional XL) 7<br />
Plutitorul 8<br />
Generalitati 8<br />
Utilizare 9<br />
Prima punere in functiune 9<br />
Indicarea statutului <strong>de</strong> functionare 11<br />
Nivel 1./2. 12<br />
Info 12<br />
Service info 13<br />
Data/ora 13<br />
Contor ore <strong>de</strong> operare 13<br />
Mod <strong>de</strong> operare manual 13<br />
Jurnal <strong>de</strong> functionare 14<br />
Setari 15<br />
Amperaj, valori limita 15<br />
Modul <strong>de</strong> service 16<br />
Resetarea <strong>de</strong>ranjamentelor 16<br />
Modul <strong>de</strong> service 17<br />
Service 18<br />
Setare limba 19<br />
Locuitori racordati 19<br />
Seria 19<br />
Testul agregatelor 19<br />
Lista <strong>de</strong>ranjamente 20<br />
Setari 21<br />
Amperaj, valori limita 24<br />
Extin<strong>de</strong>re 24<br />
Setari din fabrica 25<br />
Perioada <strong>de</strong> adaptare 26<br />
Precipitare fosfor 26<br />
Pompa dozaj 26<br />
Dezinfectare - UV 27<br />
Contactul fara potential 27<br />
Anexe 28<br />
Prezentarea timpilor preinstalati si a valorilor limita 28<br />
Semnalizarea <strong>de</strong>ranjamentelor 30<br />
Date tehnice 35<br />
Semnalizarea aprofundata a <strong>de</strong>ranjamentelor 36<br />
Declaratia <strong>de</strong> conformitate 38<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
2 / 42
Stimate client,<br />
va multumim pentru incre<strong>de</strong>rea acordata prin cumpararea acestui produs.<br />
Va rugam sa va luati cateva minute pentru a citi cu atentie aceste instructiuni <strong>de</strong> utilizare.<br />
Doar in acest fel se poate asigura o functionare sigura si fara <strong>de</strong>ranjamente a instalatiei!<br />
Observatii generale si <strong>de</strong> siguranta<br />
Unitatea <strong>de</strong> <strong>control</strong> proControl © serveste dirijarii instalatiilor <strong>de</strong> epurare SBR <strong>de</strong> tipul<br />
<strong>AQUAmax</strong> ® .<br />
proControl © este recomandata pentru racordarea a pana la doua aeratoare, doua<br />
pompe <strong>de</strong> alimentare, si doua pompe <strong>de</strong> evacuare, o pompa pentru namol, un mixer<br />
cat si patru plutitoare pentru semnalizarea nivelului.<br />
Nu exista nici un pericol provenit <strong>de</strong> la statia <strong>de</strong> epurare in cazul uitilizarii<br />
corespunzatoare. A se respecta regulile national valabile cat si datele tehnice!<br />
Daca proControl © se utilizeaza in alte scopuri <strong>de</strong>cat cele mentionate, fara aprobarea<br />
specifica a firmei ATB Umwelttechnologien GmbH si/sau nu sunt respectate<br />
instructiunile <strong>de</strong> siguranta atunci urmarea este <strong>de</strong>fectarea sau functionarea<br />
necorespunzatoare a statiei. In acest caz este exclusa orice garantie.<br />
Modificarile aparatului nu sunt admise si conduc la pier<strong>de</strong>rea pretentiilor <strong>de</strong> garantie.<br />
Nu utilizati nici un aparat care indica <strong>de</strong>ranjamente, care a cazut sau care a fost<br />
<strong>de</strong>teriorate intr-un fel.<br />
Explicatia semnelor <strong>de</strong> prevenire utilizate:<br />
Atentie! Pericol <strong>de</strong> inalta tensiune!<br />
Caracteristici ale echipamentului<br />
• Condusa <strong>de</strong> un microprocesor.<br />
• Folie <strong>de</strong> protectie. Conditionat indicata pentru spatii exterioare (IP65).<br />
• Montaj pe perete<br />
• Sesizare ca<strong>de</strong>re tensiune (UVS)<br />
• Contact fara potential pentru un echipament <strong>de</strong> alarma aditional si<br />
pentru activarea unei pompe <strong>de</strong> dozare pentru eliminare fosfor sau a unei unitati –<br />
UV - pentru igienizare<br />
• Jurnal <strong>de</strong> functionare complex<br />
• Utilizare simpla si rapida<br />
• Timpii pentru toate capacitatile sunt presetati complet<br />
• Perioada <strong>de</strong> adaptare automata in care nu este evacuat namolul in exces<br />
• Setarile parametriilor se pot alege liber<br />
• 4 limbaje la alegere pentru setarea meniului (germana, engleza, franceza,<br />
spaniola)<br />
• Se poate utiliza pentru <strong>AQUAmax</strong>® CLASSIC, BASIC si PROFESSIONAL<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
3 / 42
Montaj<br />
Fixati <strong>unitate</strong>a proControl © <strong>de</strong> unghiul special prevazut al carcasei, cu materialul <strong>de</strong><br />
prin<strong>de</strong>re livrat, intr-un loc <strong>de</strong> preferinta ferit <strong>de</strong> intemperii.<br />
In cazul unei temperaturi sub 0°C este <strong>de</strong> asteptat ca functionalitate display-ului LC sa<br />
fie puternic redusa.<br />
proControl® pentru variantele CLASSIC; BASIC si PROFESSIONAL G se livreaza gata<br />
precablate. Cablarea pe santier nu mai este necesara.<br />
proControl © pentru statiile PROFESSIONAL XL sunt livrate gata precablate cu un dulap<br />
<strong>de</strong> record separat pe o placa <strong>de</strong> montaj comuna. Deschi<strong>de</strong>rea unitatii <strong>de</strong> <strong>control</strong> nu mai<br />
este necesara!<br />
Un plan <strong>de</strong> racordare corespunzator este livrat aditional.<br />
Toate lucrarile care necesita totusi <strong>de</strong>schi<strong>de</strong>rea unitatii <strong>de</strong> <strong>control</strong> ca si racordurile<br />
electrice ale unei PROFESSIONAL XL trebuie efectuate <strong>de</strong> un electrician specialist!<br />
ATENTIE! Inainte <strong>de</strong> a <strong>de</strong>schi<strong>de</strong> <strong>unitate</strong>a proControl © si/sau dulapul <strong>de</strong><br />
racorduri trebuie intrerupt curentul electric. Lucrarile la un aparat<br />
<strong>de</strong>schis sunt efectuate doar <strong>de</strong> personal calificat! A se tine cont <strong>de</strong> un<br />
racord fazic corect. (chiar si la variantele precablate din fabrica)!<br />
Datorita faptului ca este vorba <strong>de</strong> o statie electrica cu pompe<br />
submersibile trebuie prevazuta neaparat o siguranta B16 separata si un<br />
(posibil tot separat) intrerupator diferential FI- 30 mA!<br />
Trebuie tinut cont <strong>de</strong> pozitionarea corespunzatoare a legaturilor <strong>de</strong><br />
siguranta pana la impamantarea cladirii.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
4 / 42<br />
Folie <strong>de</strong> protectie, IP 65<br />
Display cu patru randuri,<br />
luminat<br />
4 taste, tip Softkeys<br />
Soclu separat pentru racorduri,<br />
230 V, sigurante incluse<br />
Stecher rotund <strong>de</strong> legatura :<br />
Galben = bazin tampon<br />
Albastru = agregate SBR<br />
Negru = plutitori SBR<br />
(la BASIC si la CLASSIC cu ajutorul<br />
unui adaptor)
Principiul <strong>de</strong> functionare<br />
proControl © este conceputa pentru statii <strong>de</strong> epurare, care functioneaza conform<br />
principiului SBR.<br />
Aici are loc tratarea biologica, separarea namolului si evacuarea apelor epurate in unul<br />
si acelasi bazin. Apa menajera este tratata in sarje (ciclic) fiecare etapa <strong>de</strong> tratare<br />
urmand cronologic si nu in diferite bazine. Variatii <strong>de</strong> concentratie si <strong>de</strong>bit nu<br />
influenteaza calitatea epurarii apei.<br />
Un ciclu este format din<br />
1. Umplere<br />
}<br />
2. Denitrificare Faza <strong>de</strong> epurare (Faza <strong>de</strong> aerare)<br />
3. Nitrificare / eliminare carbon<br />
4. Evacuare namol in exces (nu la XL)<br />
5. Sedimentare<br />
6. Evacuare ape epurate<br />
7. Evacuare namol in exces (doar XL)<br />
8. Post operare<br />
Inainte <strong>de</strong> faza <strong>de</strong> sedimentare punctele 1.-3. sunt <strong>de</strong> regula parcurse <strong>de</strong> mai multe ori.<br />
(la CLASSIC si la BASIC)<br />
Toti timpii sunt presetati pentru utilizarea standard. D-vs introduceti doar numarul <strong>de</strong><br />
locuitori (PE)!<br />
Functionare BASIC<br />
Apa reziduala intra in bazinul <strong>de</strong> retentie grosier / namol. Aici este retinut respectiv<br />
stocat namolul primar si in unele cazuri si cel secundar. Dupa aceea apa ajunge<br />
gravitational in bazinul tampon.<br />
Apa menajera stocata este transferata in bazinul <strong>de</strong> tratare cu ajutorul principiului<br />
vaselor comunicante si a pompei <strong>de</strong> namol in exces. Aerator submersibil efectueaza<br />
intremitent aerarea si amestecarea.<br />
Dupa faza <strong>de</strong> aerare si sedimentare apa epurata este evacuata cu ajutorul unei pompe<br />
<strong>de</strong> evacuare.<br />
Faza <strong>de</strong> sedimentare se incheie :<br />
a) cu <strong>de</strong>schi<strong>de</strong>rea plutitorului [SW1] din bazinul <strong>de</strong> tratare sau<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
5 / 42
) dupa scurgerea timpului maxim programat pentru evacuare. In acest caz se<br />
activeaza o alarma.<br />
Faza <strong>de</strong> evacuare se poate prelungi (standard cu 25 sec. la echipamentele cu<br />
AQUAswitch [BASIC] iar in alte cazuri cu 0 sec). Dupa aceasta urmeaza o pauza <strong>de</strong> 1<br />
minut in care nici un agregat nu opereaza.<br />
In timpul fazei <strong>de</strong> epurare are loc inlaturarea namolului, etapa omisa in timpul perioa<strong>de</strong>i<br />
<strong>de</strong> adaptare.<br />
Functionare PROFESSIONAL<br />
Apa reziduala intra in bazinul <strong>de</strong> retentie grosier / namol. Aici este retinut respectiv<br />
stocat namolul primar si in unele cazuri si cel secundar. Dupa aceea apa ajunge<br />
gravitational in bazinul tampon.<br />
Ciclul <strong>de</strong> tratare porneste cu umplerea bazinului SBR. La atingerea in bazinul <strong>de</strong><br />
stocare a unui nivel <strong>de</strong> apa suficient (plutitorul <strong>de</strong> jos [SW3] inchis), aceasta este<br />
transportata cu ajutorul pompei <strong>de</strong> umplere in bazinul SBR.<br />
Umplerea se incheie:<br />
a) dupa scurgerea timpului programat<br />
b) cand [SW3] <strong>de</strong>schi<strong>de</strong> (nivelul minim in bazinul <strong>de</strong> stocare) sau<br />
c) volumul maxim in bazinul <strong>de</strong> tratare este atins (Hwmax, plutitorul <strong>de</strong> sus din bazinul<br />
SBR [SW2] inchis)<br />
Daca plutitorul <strong>de</strong> jos [SW1] din bazinul <strong>de</strong> tratare nu este inca inchis la inceputul fazei<br />
<strong>de</strong> sedimentare si / sau nu este suficienta apa in bazinul <strong>de</strong> stocare, atunci instalatia<br />
trece in modul econom <strong>de</strong> operare. In modul econom aerarea este redusa. Acesta se<br />
incheie odata ce plutitorul [SW3] inchi<strong>de</strong>.<br />
Dupa umplere porneste faza <strong>de</strong> <strong>de</strong>nitrificare, careia ii urmeaza faza <strong>de</strong> nitrificare. In<br />
ambele faze (ca si in modul econom <strong>de</strong> operare) aerarea este intermitenta.Toti timpii se<br />
pot seta separat.<br />
Umplerea, <strong>de</strong>nitrificarea si nitrificarea pot fi parcurse <strong>de</strong> mai multe ori consecutiv.<br />
Ultima umplere are loc cel tarziu la doua ore inainte <strong>de</strong> inceperea fazei <strong>de</strong><br />
sedimentare.<br />
Faza <strong>de</strong> sedimentare urmeaza dupa faza <strong>de</strong> tratare aeroba. Namolul sedimenteaza iar<br />
apa epurata este evacuata.<br />
Evacuarea se incheie:<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
6 / 42
a) cu <strong>de</strong>schi<strong>de</strong>rea plutitorului <strong>de</strong> jos [SW1] din bazinul <strong>de</strong> tratare sau<br />
b) dupa scurgerea timpului maxim programat pentru evacuare. In acest caz se<br />
activeaza o alarma.<br />
Dupa evacuarea apei la unitatile PROFESSIONAL G se incheie si ciclul.<br />
La PROFESSIONAL XL urmeaza dupa evacuarea apei epurate si evacuarea namolului<br />
in exces. La PROFESSIONAL G evacuarea namolului in exces are loc in timpul fazei<br />
<strong>de</strong> aerare.<br />
Evacuarea namolului in exces in timpul fazei <strong>de</strong> adaptare este omisa la ambele tipuri.<br />
Dupa aceasta urmeaza o pauza <strong>de</strong> 1 minut in care nici un agregat nu opereaza.<br />
Functionare in cazul inundatilor (doar PROFESSIONAL XL)<br />
In cazul in care statia este alimentata cu atata apa incat volumul <strong>de</strong> utilizare maxim al<br />
bazinultui tampon este <strong>de</strong>pasit (plutitorul <strong>de</strong> sus in bazinul tampon [SW4] inchi<strong>de</strong>), iar<br />
in bazinul SBR mai este disponibila capacitate <strong>de</strong> umplere (plutitorul <strong>de</strong> sus in SBR<br />
[SW2] inca <strong>de</strong>schis), se efectueaza o umplere imediata pana cand:<br />
a) Plutitorul <strong>de</strong> sus in bazinul SBR- [SW2] inchis (urmeaza imediat o sedimentare,<br />
scurtata la jumatate din timpul normal si este indicata o alarma)<br />
b) Timpul <strong>de</strong> umplere standard a expirat (daca dupa aceea plutitorul <strong>de</strong> sus in bazinul<br />
tampon [SW4] se <strong>de</strong>schi<strong>de</strong> continua ciclul normal <strong>de</strong> tratare. In cazul in care mai<br />
este inca inchis dupa o aerare intermediara se umple in continuare)<br />
c) Plutitorul <strong>de</strong> jos din bazinul tampon [SW3] <strong>de</strong>schi<strong>de</strong>.<br />
ATENTIE! In ultimele doua ore inainte <strong>de</strong> faza <strong>de</strong> sedimentare cat si in faza <strong>de</strong> sedimentare<br />
nu se efectueaza NICI o umplere!<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
7 / 42
Plutitorul <strong>de</strong> comutare<br />
Plutitor <strong>de</strong>schis<br />
= 0 in display<br />
(plutitorul este in pozitia <strong>de</strong> jos)<br />
Plutitor inchis<br />
= 1 in display<br />
(plutitorul este in pozitia sus)<br />
ATENTIE! Schimbarea <strong>de</strong> comutare are un sunet tipic. Comutarea are loc <strong>de</strong>stul<br />
<strong>de</strong> tarziu chiar daca optic plutitorul pare sa fie sus sau respectiv jos (unghiul <strong>de</strong><br />
comutare fata <strong>de</strong> suprafata apei +/- 50°).<br />
Atentie la indicatorul <strong>de</strong> statut din display-ul unitatii <strong>de</strong> <strong>control</strong>!<br />
AQUAswitch<br />
In cazul plutitorului AQUAswitch este vorba <strong>de</strong> un comutator cu contact Reed<br />
integrat in conducta <strong>de</strong> aerisire la BASIC. Plutitorul nu este vizibil din exterior.<br />
Statutul <strong>de</strong> comuntare poate fi verificat in modul <strong>de</strong> operare manual.<br />
Generalitati<br />
Manipularea se efectueaza cu ajutorul celor 4 taste, ale caror<br />
functie <strong>de</strong>pin<strong>de</strong> <strong>de</strong> meniul, respectiv submeniul in care va<br />
aflati.<br />
In ultimul rand pe display sunt indicate functiile tastelor in<br />
respectivul meniu. Cel <strong>de</strong>-al doilea rand <strong>de</strong> sus – cel care se<br />
afla intre doua sageti – este randul in care se efectueaza<br />
modificarile. Adica cu ajutorul tastelor cu sageata <strong>de</strong>asupra<br />
se alege submeniul dorit (asemanator numerelor <strong>de</strong> telefon<br />
din agenda unui telefon mobil); cand acesta este intre cele<br />
doua sageti () se confirma cu tasta “OK”.<br />
Functii posibile ale tastelor<br />
- ↓ Rasfoire meniu sus jos<br />
- Pos Apasand ajungeti cu cursorul in dreptul cifrei pe care dorti sa o modificati.<br />
Cursorul inainteaza doar intr-o singura directie; daca ati trecut <strong>de</strong> cifra dorita<br />
apasati pana ajungeti din nou la pozitia prece<strong>de</strong>nta!<br />
- Value Apasand, rasfoiti cifrele posibile. Adica 0 – 9 sau respectiv zilele Mo – Su.<br />
- OK Prin apasarea tastei respective confirmati modificarea efectuata.<br />
- ESC Prin apasarea tastei ajungeti in meniu un nivel mai sus.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
8 / 42
Prima punere in functiune<br />
La prima punere in functiune se efectueaza reglarile <strong>de</strong> baza si teste. Odata cu introducerea<br />
numarului <strong>de</strong> locuitori ceilalti parametrii importanti vor fi automat presetati. Va recomandam<br />
insa, dupa punerea in functiune, sa mai verificati inca o data, la SETARI, parametrii presetati.<br />
In Service Mo<strong>de</strong> aveti posibilitatea si ulterior sa efectuati modificarile dorite.<br />
Professional XL<br />
Ver2.01 (30.05.08)<br />
Beliebige Taste<br />
Sprache wählen<br />
<strong>de</strong>utsch<br />
↓ ↑ OK ESC<br />
Service Mo<strong>de</strong><br />
Bitte Co<strong>de</strong> eingeben<br />
_ _ _ _ _ _ _<br />
Pos Wert OK ESC<br />
Datum/Uhr stellen<br />
Datum : Di,09.05.06<br />
Uhrzeit: 12:49:21<br />
Pos Wert OK ESC<br />
Bitte wählen Sie<br />
Anlage<br />
Professional XL<br />
↓ ↑ OK ESC<br />
Bitte wählen Sie<br />
Anlagengrosse<br />
Professional XL 60<br />
↓ ↑ OK ESC<br />
Bitte wählen Sie<br />
Seriennummer<br />
00000000<br />
Pos Wert OK ESC<br />
Service<br />
00 Monate<br />
Tel………<br />
Pos Wert OK ESC<br />
Tipul statiei.<br />
Indicatia versiunii si a datei <strong>de</strong> fabricatie<br />
Continuare cu o tasta oarecare.<br />
Alegeti limba dorita cu tastele ↑↓ si confirmati cu tasta OK. Limbile care<br />
stau la dispozitie sunt: germana, engleza, franceza si spaniola.<br />
Pentru programarea parametrilor <strong>de</strong> operare este necesar codul <strong>de</strong><br />
service. In meniul “Service mo<strong>de</strong>” se tasteaza codul <strong>de</strong> acces. Acesta<br />
este disponibil doar firmei care a efectuat montajul si efectueaza<br />
punerea in functiune. Cu tastele POS si Wert introduceti codul. Dupa<br />
introducerea corecta a codului ajungeti in meniul <strong>de</strong> activare.<br />
Cu tastele Pos si Wert introduceti data (indicatie = TT.MM.JJ) si<br />
ora (indicatie = HH:MM:SS) si confirmati cu OK.<br />
Ziua saptamanii este introdusa automat.<br />
Este foarte important pentru introducerile corecte in jurnalul <strong>de</strong><br />
functionare!<br />
Alegeti cu tastele ↑↓ tipul statiei si confirmati cu OK.<br />
Alegeti cu tastele ↑↓ marimea statiei ( numarul <strong>de</strong> locuitori<br />
racordati ) si confirmati cu OK.<br />
Important pentru alegerea corecta a parametriilor presetati!<br />
Introduceti cu Pos si Wert numarul <strong>de</strong> serie, il regasiti pe rama statiei<br />
<strong>AQUAmax</strong> ® (BASIC/CLASSIC/PROFESSIONAL G) resp. pe dulapul<br />
electric sau pe placa <strong>de</strong> montaj (PROFESSIONAL XL) (nu pe cea a<br />
unitatii <strong>de</strong> <strong>control</strong>!) si confirmati cu OK.<br />
Va rugam sa tineti cont ca si numarul introdus sa fie corect.<br />
Exista posibilitatea <strong>de</strong> a introduce un interval <strong>de</strong> timp pentru efectuarea<br />
lucrarilor <strong>de</strong> intretinere. Dupa expirarea acestei perioa<strong>de</strong> va aparea un<br />
anunt in display (00 Monate=Funktion ausser Kraft- 00 luni= functiune<br />
scoasa din utilizare)<br />
Aditional poate fi introdus si un nr. <strong>de</strong> telefon (Service). In cazul in care<br />
aceasta optiune nu se utilizeaza <strong>unitate</strong>a preia automat nr. <strong>de</strong> service al ATB.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
9 / 42
Testlauf<br />
Belüfter 1<br />
=aus SW=1000<br />
Beliebige Taste…<br />
Grun<strong>de</strong>instellungen<br />
korrekt?<br />
ja nein<br />
ATB<br />
Umwelttechnologien<br />
Professional XL 60<br />
Ver2.01 (30.05.08)<br />
Vezi <strong>de</strong>scriere capitolul testul agregatelor, pag. 17.<br />
Important pentru functionarea corecta a agregatelor!<br />
Ati introdus date gresite? Prin apasarea tastei nein poate fi repetata<br />
prima punere in functiune.<br />
Daca datele sunt corecte, confirmati cu ja si va aparea pentru circa<br />
5 secun<strong>de</strong> indicatia cu datele producatorului, marimea statiei (numarul<br />
<strong>de</strong> locuitori racordati), numarul versiunii si data programarii.<br />
Dupa aceea are loc modificarea indicatiei <strong>de</strong> statut.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
10 / 42
Indicarea statutului <strong>de</strong> operare Nivelul 1. Nivelul 2.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
11 / 42
Indicarea statutului <strong>de</strong> operare<br />
Normalbetr 2h 58:55<br />
Belüften: 0h 00:30<br />
Schwimmer=1010<br />
beliebige Taste ...<br />
Fehler [10]<br />
Hochwasser<br />
max. Niveau<br />
beliebige Taste ...<br />
Statutul <strong>de</strong> operare va informeaza <strong>de</strong>spre actuala stare a statiei <strong>de</strong><br />
epurare. Sunt indicate umplerea, <strong>de</strong>nitrificarea, operarea normala, faza<br />
<strong>de</strong> sedimentare, evacuarea, modul econom si timpul ramas al fazei<br />
respective (exceptia o face modul econom). In timpul operarii normale si<br />
a operarii in modul econom este indicat timpul <strong>de</strong> aerare ramas<br />
respectiv pauza intre doua faze <strong>de</strong> aerare.<br />
In al treilea rand aveti informatii <strong>de</strong>spre actuala pozitie a plutitoarelor. 1<br />
sta pentru pozitia “inchis” a plutitorului, 0 pentru pozitia “<strong>de</strong>schis” a<br />
plutitorului.<br />
Ordinea in care sunt indicate corespun<strong>de</strong> numerotarii (racordul electric)<br />
din dulapul electric.<br />
Pos. 1 = SW1 = Plutitor SBR jos [HW, min]<br />
Pos. 2 = SW2 = Plutitor SBR sus [HW, max] nur PROFESSIONAL (BASIC si CLASSIC-0)<br />
Pos. 3 = SW3 = Plutitor bazin tampon jos [doar PROFESSIONAL (BASIC si CALSSIC-0)]<br />
Pos. 4 = SW4 = Plutitor bazin tampon sus doar la [PROFESSIONAL XL (optional la<br />
PROFESSIONAL G; BASIC si CLASSIC -0)]<br />
In cazul unui <strong>de</strong>ranjament apare in display raportul respectiv alternativ<br />
cu statutul <strong>de</strong> operare.<br />
Prin apasarea unei taste oarecare se aprin<strong>de</strong> iluminatia in display.<br />
Printr-o a doua apasare a unei taste oarecare ajungeti in primul meniu.<br />
Daca nu se mai apasa nici o tasta iluminatia se stinge dupa cca. 10 min.<br />
Primul meniu / submeniul (Nivel 1/ Nivel 2)<br />
Prin apasarea unei taste oarecare ajungeti in primul meniu (Nivel 1). Aici obtineti informatii<br />
suplimentare. Prin apasarea tastei “OK” in acest meniu, ajungeti la submeniul (Nivel 2)<br />
corespunzator punctului care se afla in paranteze .<br />
Prin apasarea ↓↑ alegeti optiunile posibile ale meniului. Prin apasarea tastei “ESC” ajungeti<br />
din meniu la indicatorul <strong>de</strong> statut.<br />
Info<br />
Fehler-Reset<br />
< Info ><br />
Service Info<br />
↓ ↑ OK ESC<br />
OK<br />
Professional XL 60<br />
Ver2.01 (30.05.08)<br />
Seriennummer<br />
00000003<br />
Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />
Indicarea informatiilor <strong>de</strong>spre actuala<br />
instalatie, tip si marime instalatie (persoane<br />
racordate), versiunea si numarul <strong>de</strong> serie.<br />
Afisajul poate fi parasit prin apasarea unei<br />
taste sau dupa 7 secun<strong>de</strong> afisajul dispare<br />
automat si se ajunge iarasi in primul meniu.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
12 / 42
Service Info<br />
Info<br />
< Service Info ><br />
Datum/Uhrzeit<br />
↓ ↑ OK ESC<br />
Afisare datei pentru urmatorul service si a numarului <strong>de</strong> telefon al firmei resposabile ( in<br />
cazul in care a fost introdus la punerea in functiune).<br />
Prin apasare unei taste oarecare va intoarceti inapoi in meniu.<br />
Data/ora (Datum / Uhrzeit)<br />
Service Info<br />
< Datum/Uhrzeit ><br />
Betriebszähler<br />
↓ ↑ OK ESC<br />
Cu “OK” ajungeti in submeniu. Cu tastele Pos si Wert fixati data si ora. Pentru<br />
documentarea in jurnalul <strong>de</strong> functionare este absolut necesara o setare corecta!<br />
Cu tasta Pos alegeti parametrul care doriti sa fie modificat (ziua saptamanii este<br />
setata automat). Prin apasarea tastei Wert se creste cu valoarea 1. Cu OK salvati<br />
modificarile iar indicatia sare in meniul 1. Cu ESC parasiti meniul fara salvare.<br />
Prin apasarea tastei ↓ ajungeti la punctul urmator.<br />
Contor ore <strong>de</strong> operare (Betriebszähler)<br />
Datum/Uhrzeit<br />
< Betriebszähler ><br />
Hand-Modus<br />
↓ ↑ OK ESC<br />
La rasfoirea acestui meniu apar urmatoarele submeniuri cu aceasi structura <strong>de</strong> operare:<br />
Belüfter = Aerator, Beschickungspumpe = Pompa <strong>de</strong> admisie, Klarwasserpumpe = Pompa<br />
<strong>de</strong> evacuare, Gesamtlaufzeit = Timp total <strong>de</strong> operare, Lfzt. Spar-Modus = Timp <strong>de</strong><br />
functionare in modul economic. Aici sunt protocolati timpii totali <strong>de</strong> functionare ai agregatelor<br />
<strong>de</strong> la punerea in functiune. Sunt indicate si agregate (d.ex. aerator 2 la PROFESSIONAL G),<br />
chiar daca acestea nu sunt montat la unele instalatii. Ca timp <strong>de</strong> functionare apare atunci 0.<br />
Cu ”ESC” parasiti meniul.<br />
Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />
Modul <strong>de</strong> operare manual (Hand-Modus)<br />
Betriebszähler<br />
< Hand-Modus ><br />
Logbuch<br />
↓ ↑ OK ESC<br />
OK<br />
OK<br />
ESC<br />
OK<br />
ESC<br />
OK<br />
ESC<br />
Service<br />
03.01.09<br />
Tel.05731302300<br />
beliebige Taste<br />
Datum/Uhr stellen<br />
Datum : Di,09.05.06<br />
Uhrzeit: 12:49:21<br />
Pos Wert OK ESC<br />
Betriebszähler<br />
Belüfter1<br />
4h 10:49<br />
↓ ↑ ESC<br />
pot. Kontakt<br />
< Belüfter1 ><br />
Belüfter2<br />
↓ ↑ OK ESC<br />
La rasfoirea acestui meniu apar urmatoarele submeniuri cu aceasi structura <strong>de</strong> operare:<br />
OK<br />
OK<br />
ESC<br />
Datum/Uhrzeit<br />
geän<strong>de</strong>rt<br />
Hand-Modus (1010)<br />
Belüfter1<br />
aus I= 0,0A<br />
an aus ESC<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
13 / 42<br />
Service Info<br />
< Datum/Uhrzeit ><br />
Betriebszähler<br />
↓ ↑ OK ESC
Hand-Modus<br />
< Logbuch ><br />
Einstellungen<br />
↓ ↑ OK ESC<br />
Belüfter = Aerator, Beschickungspumpe = Pompa <strong>de</strong> admisie, Klarwasserpumpe = Pompa<br />
<strong>de</strong> evacuare, SWx = plutitor.<br />
Aici aflati informatii <strong>de</strong>spre amperajul actual al agregatelor si <strong>de</strong>spre pozitia plutitoarelor.<br />
Dupa ce ati trecut in unul din aceste submeniuri puteti testa fiecare agregat in parte sau<br />
activa in cazul lucrarilor <strong>de</strong> intretinere in<strong>de</strong>pen<strong>de</strong>nt <strong>de</strong> programul <strong>de</strong> operare automat. Cu OK<br />
confirmati agregatul respectiv. Cu tastele “An” (pornit) respectiv “Aus” (oprit) activati sau<br />
<strong>de</strong>zactivati agregatul respectiv.<br />
In cazul in care a aparut un <strong>de</strong>ranjament la un anumit agregat, atunci apare “Fehler” in<br />
penultimul rand pe display. Daca totul este in ordine este indicat amperajul momentan al<br />
agregatului.<br />
Grupurile <strong>de</strong> agregate sunt conectate intre ele, astfel incat nu se poate folosi modul <strong>de</strong><br />
operare manual simultan pentru <strong>de</strong> ex. aerator si pompa <strong>de</strong> evacuare. Daca un agregat sau<br />
un grup <strong>de</strong> agregate functioneaza acesta se va opri imediat la operarea altui agregat in<br />
modul <strong>de</strong> operare manual.<br />
ATENTIE! Modul <strong>de</strong> operare manual este in<strong>de</strong>pen<strong>de</strong>nt <strong>de</strong> pozitia actuala a<br />
plutitoarelor <strong>de</strong> comutare!<br />
Dupa 15 minute instalatia trece automat din modul <strong>de</strong> operare manual in cel automat.<br />
Parasiti meniul cu tasta “ESC”.<br />
Dupa incheierea operarii manuale, instalatia porneste din punctul in care se afla in momentul<br />
accesarii meniului manual.<br />
Daca instalatia se afla in faza <strong>de</strong> sedimentare, atunci aceasta va continua sa cronometreze<br />
timpul necesar ramas pentru aceasta faza.<br />
Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />
Jurnal electronic (Logbuch)<br />
ESC<br />
OK<br />
Tageswert<br />
< Meldung ><br />
Fehler<br />
↓ ↑ OK ESC<br />
ESC<br />
OK<br />
Meldung<br />
10.05.06 12:24:59<br />
Belüfter1<br />
↓ ↑ --> ESC<br />
Nächste<br />
Meldung<br />
In jurnalul electronic sunt memorati timpi <strong>de</strong> functionare, evenimente si <strong>de</strong>ranjamente.<br />
Astfel in cazul unui <strong>de</strong>fect sau lucrarilor <strong>de</strong> intretinere se pot obtine repe<strong>de</strong> informatii<br />
folositoare.<br />
Cu “OK” ajungeti in submeniu. Cu sagetile ↓ si “OK” alegeti parametrul dorit (Meldung =<br />
Raport; Fehler = Deranjament; Ereignis = Eveniment).<br />
Este intot<strong>de</strong>auna indicat ultimul <strong>de</strong>ranjament, raport, eveniment etc. Cu sagetile ↓↑se poate<br />
parcurge toata lista. Cu sageata → puteti obtine informatii suplimentare <strong>de</strong>spre actualul<br />
eveniment.<br />
Unitatea memoreaza maxim 4096 <strong>de</strong> informatii. La atingerea numarului maxim, noile<br />
evenimete sunt trecute pe locul evenimentului celui mai vechi, adica evenimentul 4097 va lua<br />
locul evenimetului 1/4096. Indicat este intot<strong>de</strong>auna ultimul eveniment inregistrat.<br />
Parasiti meniul cu tasta “ESC”.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
14 / 42<br />
Meldung<br />
Meldung<br />
--><br />
10.05.06 12:24:59<br />
auto aus<br />
↓ ↑ --> ESC<br />
--><br />
10.05.06 12:24:59<br />
650 / 650<br />
↓ ↑ --> ESC<br />
--><br />
Vorhergehen<strong>de</strong><br />
Meldung
Parametrii in parte:<br />
Raport (Meldung) (maxim 4096)<br />
Aici este documentata complet orice modificare care are loc in modul <strong>de</strong> operare al<br />
instalatiei. De exemplu cand a comutat un plutitor, cand a avut loc ultima evacuare, cand s-a<br />
trecut din operare manuala in automata, etc.<br />
Deranjament (Fehler) (maxim 256)<br />
Aici sunt memorate toate <strong>de</strong>ranjamentele sau <strong>de</strong>fectiunile aparute. Explicatia la fiecare<br />
<strong>de</strong>ranjament posibil o gasiti in anexa. Dupa resetarea unui <strong>de</strong>ranjament, este documentata<br />
aceasta resetare ca raport cu data si cu remarca “inaktiv”.<br />
Eveniment (Ereignis) (maxim 256)<br />
Aici este documentata orice modificare manuala efectuata (d.ex. schimbarea timpului <strong>de</strong><br />
operare a unui agregat) si ca<strong>de</strong>rile <strong>de</strong> tensiune.<br />
Timp <strong>de</strong> functionare (Laufzeit) (maxim 256)<br />
In acest meniu sunt memorati timpii <strong>de</strong> functionare saptamanali.<br />
Valori zilnice (Tageswert) (maxim 512)<br />
Timpi <strong>de</strong> operare pe zi.<br />
Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />
Setari (Einstellungen)<br />
Logbuch<br />
< Einstellungen ><br />
Stromgrenzen<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
Beschickung<br />
Dauer<br />
= 0,8 Minuten<br />
↓ ↑ ESC<br />
Cu “OK” ajungeti in submeniul corespunzator. Cu sagetile ↓↑ puteti citii actualii parametri<br />
setati.<br />
Valorile <strong>de</strong> setare standard a agregatelor le gasiti in anexa. O modificare a acestor parametrii<br />
este posibila doar in “Service Mo<strong>de</strong>”. Aici gasiti si <strong>de</strong>scrierea fiecarui parametru in parte.<br />
Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />
Amperaj, valori limita (Stromgrenzen)<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
15 / 42
Daca valorile energetice preluate sunt sub nivelul limita este activata o alarma. Modificari se<br />
pot efectua doar in Service-Mo<strong>de</strong> (vezi pag 22/24).<br />
Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />
Modul <strong>de</strong> service (Service Mo<strong>de</strong>)<br />
Einstellungen<br />
< Service Mo<strong>de</strong> ><br />
Fehler-Reset<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
ATENTIE! Acest meniu poate fi accesat doar <strong>de</strong> personalul care a efectuat<br />
montajul instalatiei sau <strong>de</strong> personalul <strong>de</strong> service. Pentru a accesa acest meniu<br />
aveti nevoie <strong>de</strong> codul <strong>de</strong> acces.<br />
In “Service Mo<strong>de</strong>” sunt modificabili toti parametrii <strong>de</strong> operare ai instalatiei. In cazul setarilor<br />
necorespunzatoare, care pot duce la <strong>de</strong>teriorarea echipamentului, firma ATB Umwelttechnologien<br />
refuza orice pretentie <strong>de</strong> garantie!<br />
Service-Mo<strong>de</strong> este <strong>de</strong>scris <strong>de</strong>taliat in alt capitol.<br />
Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />
Resetarea <strong>de</strong>ranjamentelor (Fehler-Reset)<br />
Service Mo<strong>de</strong><br />
< Fehler-Reset ><br />
OK Alle Fehler löschen?<br />
Info<br />
↓ ↑ OK ESC<br />
ja<br />
nein<br />
ja nein<br />
La aparitia unui <strong>de</strong>ranjament sau <strong>de</strong>fect, acesta este indicat in display ca text si<br />
printr-un semnal acustic. Semnalul acustic inceteaza in momentul apasarii unei<br />
taste oarecare. Display –ul palpaie pana in momentul resetarii <strong>de</strong>ranjamentului<br />
(confirmare cu “ja” a indicatiei “Alle Fehler löschen”). Dupa resetare, <strong>de</strong>ranjamentul<br />
se gaseste in jurnalul electronic.<br />
Daca nu efectuati o resetare a <strong>de</strong>ranjamentului, acesta nu va mai fi in cazul unei<br />
noi aparitii inca odata receptionat.<br />
Doar dupa resetarea automata la 72 <strong>de</strong> ore poate fi recunoscut daca<br />
<strong>de</strong>ranjamentul respectiv mai este actual sau reapare.<br />
O resetare automata a unui <strong>de</strong>ranjament este memorata in jurnalul electronic cu<br />
remarca “inaktiv”.<br />
Va rugam la aparitia unui <strong>de</strong>ranjament sa informati personalul <strong>de</strong> service. Acesta<br />
se va ocupa <strong>de</strong> remedierea <strong>de</strong>ranjamentului.<br />
Prin apasarea sagetii ↓ ajungeti la urmatorul punct.<br />
Info (ve<strong>de</strong>ti mai sus.)<br />
Service Mo<strong>de</strong><br />
Bitte Co<strong>de</strong> eingeben<br />
_ _ _ _ _ _<br />
Pos Wert OK ESC<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
16 / 42
Modul <strong>de</strong> service (Service Mo<strong>de</strong>)<br />
Einstellungen<br />
< Service Mo<strong>de</strong> ><br />
Fehler-Reset<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
Service Mo<strong>de</strong><br />
Bitte Co<strong>de</strong> eingeben<br />
_ _ _ _ _ _<br />
Pos Wert OK ESC<br />
ATENTIE! Acest meniu poate fi<br />
accesat doar <strong>de</strong> personalul care a<br />
efectuat montajul instalatiei sau <strong>de</strong><br />
personalul <strong>de</strong> service. Pentru a<br />
accesa acest meniu aveti nevoie <strong>de</strong><br />
codul <strong>de</strong> acces. In “Service Mo<strong>de</strong>”<br />
sunt modificabili toti parametrii <strong>de</strong><br />
operare ai instalatiei. Va rugam sa<br />
tineti cont <strong>de</strong> faptul ca datele incorecte<br />
pot duce la o functionare <strong>de</strong>ficitara.<br />
Validitatea modificarilor efectuate<br />
nu este <strong>control</strong>ata. In cazul setarilor<br />
necorespunzatoare, care pot<br />
duce la <strong>de</strong>teriorarea echipamentului,<br />
firma ATB Umwelttechnologien<br />
refuza orice pretentie <strong>de</strong> garantie!<br />
Va rugam sa ne contactati, va stam<br />
cu placere la dispozitie.<br />
Fiecare parametru in parte este<br />
prezentat pe urmatoarele pagini.<br />
Pentru intrebari va rugam sa ne<br />
contactati!<br />
La accesarea acestui meniu, toate<br />
agregatele vor fi oprite (exceptie face<br />
testul agregatelor).<br />
La parasirea acestui meniu, programul<br />
va continua din punctul in care<br />
era la momentul accesarii meniului<br />
<strong>de</strong> service.<br />
Daca se efectueaza testul aggregatelor<br />
in timpul fazei <strong>de</strong> sedimentare,<br />
atunci instalatia trece in modul <strong>de</strong><br />
functionare normal pentru o perioada<br />
<strong>de</strong> timp egala cu cea care ar fi ramas<br />
din faza <strong>de</strong> sedimentare.<br />
ESC<br />
OK<br />
ESC<br />
Alarmkontakt<br />
< Service ><br />
Sprache wählen<br />
↓ ↑ OK ESC<br />
Service<br />
< Sprache wählen ><br />
Anlagengrösse<br />
↓ ↑ OK ESC<br />
Sprache wählen<br />
< Anlagengröße ><br />
Seriennummer<br />
↓ ↑ OK ESC<br />
Anlagengrösse<br />
< Seriennummer ><br />
Testlauf<br />
OK ESC<br />
Seriennummer<br />
<br />
Fehlerliste<br />
↓ ↑ OK ESC<br />
Testlauf<br />
<br />
Einstellunge<br />
↓ ↑ OK ESC<br />
Fehlerliste<br />
< Einstellungen ><br />
Stomgrenzen<br />
↓ ↑ OK ESC<br />
Einstellungen<br />
< Stromgrenzen><br />
Erweiterung<br />
↓ ↑ OK ESC<br />
Stromgrenzen<br />
< Erweiterung><br />
Werkseinstellung<br />
↓ ↑ OK ESC<br />
Erweiterung<br />
<br />
Einfahren<br />
↓ ↑ OK ESC<br />
Werkseinstellungen<br />
< Einfahren ><br />
Phosphatfällung<br />
↓ ↑ OK ESC<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
17 / 42<br />
OK<br />
OK<br />
OK<br />
OK<br />
ESC<br />
OK<br />
OK<br />
ES<br />
OK<br />
ESC<br />
OK<br />
OK<br />
ESC<br />
ESC<br />
OK<br />
OK<br />
OK<br />
ESC<br />
ESC<br />
ESC<br />
ESC<br />
ESC<br />
Service<br />
07.01.09<br />
Tel:05731302300<br />
RST EDIT ESC<br />
Sprache wählen<br />
<strong>de</strong>utsch<br />
↓ ↑ OK ESC<br />
Bitte wählen Sie<br />
Anlage<br />
Professional XL<br />
↓ ↑ OK ESC<br />
Bitte wählen Sie<br />
Seriennummer<br />
10000000<br />
Pos Wert OK ESC<br />
Testlauf<br />
Belüfter 1<br />
= aus SW = 1000<br />
beliebige Taste<br />
Fehler [0]<br />
Belüfter 1<br />
Strom Min<br />
↓ ↑ Info ESC<br />
Beschickung<br />
Dauer<br />
= 0,8 Minute<br />
↓ ↑ EDIT ESC<br />
Stromgrenzen<br />
Belüfter 1<br />
l=3,0A…7,5A<br />
↓ ↑ EDIT ESC<br />
Protokoll RS232<br />
BeschickungDeni<br />
Pumpenstoß<br />
↓ ↑ OK ESC<br />
Bitte wählen Sie<br />
Grun<strong>de</strong>instellunge<br />
ja nein<br />
Einfahren<br />
Zähler<br />
=263<br />
EDIT ESC
Service<br />
Exista posibilitatea setarii unui interval <strong>de</strong> service (max 12 luni).<br />
Cand aceasta perioada expira proControl® ne anunta (00-Monate = Funktion ausser Kraft<br />
adica 00 luni = functie scoasa din utilizare).<br />
Aditional mai poate fi introdus si un numar <strong>de</strong> service. Daca nu se introduce nici un numar<br />
atunci <strong>unitate</strong>a preia automat numarul ATB.<br />
Cu Pos, Wert si OK pot fi modificati si salvati toti parametrii.<br />
Dupa efectuarea lucrarilor <strong>de</strong> service prin apasarea tastei RST si ‘’da’’ (‘’ja’’) se introduce<br />
urmatorul interval <strong>de</strong> timp.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
18 / 42
Setarea limbajului <strong>de</strong> operare (Sprache wählen)<br />
Alarmkontakt<br />
< Sprache wählen ><br />
Anlagengröße<br />
↓ ↑ OK ESC<br />
Limbajul posibil este: germana, engleza, franceza sau spaniola. Alegeti limbajul dorit<br />
confirmati cu “OK” si veti ajunge in urmatorul meniu. Cu “ESC” parasiti meniul fara a memora<br />
schimbarile.<br />
Locuitori racordati (Anlagengröße)<br />
Sprache wählen<br />
< Anlagengröße ><br />
Seriennummer<br />
↓ ↑ OK ESC<br />
Aici se selecteaza sau modifica tipul instalatiei (<strong>AQUAmax</strong>® PROFESSIONAL G, XL,<br />
CLASSIC sau BASIC). Prin alegerea tipului instalatiei <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> incarca automat<br />
valorile <strong>de</strong> operare corespunzatoare astfel nu mai sunt necesare modificari in meniul Setari<br />
“Einstellunge”. Parametrii corespunzatori ii gasiti in anexa.<br />
Seria (Seriennummer)<br />
Anlagengröße<br />
<br />
Testlauf<br />
↓ ↑ OK ESC<br />
Aici se introduce sau modifica numarul <strong>de</strong> serie al instalatiei <strong>AQUAmax</strong>®.<br />
Testul agregatelor (Testlauf)<br />
Seriennummer<br />
< Testlauf ><br />
Fehlerliste<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
OK<br />
OK<br />
ESC<br />
OK<br />
OK<br />
OK<br />
OK<br />
ESC<br />
Sprache wählen<br />
<strong>de</strong>utsch<br />
↓ ↑ OK ESC<br />
Bitte wählen Sie<br />
Anlage<br />
Professional XL<br />
↓ ↑ OK ESC<br />
Bitte wählen Sie<br />
Seriennummer<br />
10000000<br />
↓ ↑ OK ESC<br />
Testlauf<br />
Belüfter1<br />
=aus SW = 1000<br />
beliebige Taste...<br />
OK<br />
OK<br />
ESC<br />
Schwimmerschalter<br />
Anlagengröße<br />
Anlagengröße<br />
Professiona XL 60<br />
↓ ↑ OK ESC<br />
Testlauf<br />
Belüfter1<br />
=ein SW = 1010<br />
beliebige Taste...<br />
In acest meniu puteti testa functionalitatea fiecarui agregat in parte si a plutitoarelor.<br />
Dupa comutarea unui plutitor oarecare porneste testul agregatelor. Fiecare agregat<br />
functioneaza cca. 5 secun<strong>de</strong> in faza <strong>de</strong> test. Este indiferent care plutitor se alege pentru<br />
pornirea testului, important este doar ca acesta sa treaca din pozitia inchis in <strong>de</strong>schis sau<br />
invers. Daca un plutitor a comutat se au<strong>de</strong> prin zgomotul tipic <strong>de</strong> comutare sau se ve<strong>de</strong> in<br />
display. Cifra 1 corespun<strong>de</strong> plutitor inchis, 0 corespun<strong>de</strong> plutitor <strong>de</strong>schis. Indicatorul din<br />
display se schimba doar dupa ce testul unui agregat este incheiat<br />
Prima cifra este indicatorul plutitorului <strong>de</strong> jos din SBR (SW1, Hw,min), a doua este indicatorul<br />
plutitorului <strong>de</strong> sus din SBR (SW2, HW,max), a treia este indicatorul plutitorului <strong>de</strong> jos din<br />
bazinul <strong>de</strong> stocare (SW3) iar a patra este indicatorul plutitorului <strong>de</strong> sus din bazinul <strong>de</strong> stocare<br />
(SW4, optional).<br />
In cazul <strong>de</strong> mai sus este inchis doar plutitorul <strong>de</strong> jos din SBR. Prin comutarea plutitorului <strong>de</strong><br />
jos din bazinul <strong>de</strong> stocare este luat in functiune primul agregat (aerator 1). Dupa cca. 5<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
19 / 42<br />
5 sec<br />
Testlauf<br />
Beschicker1<br />
=aus SW = 1010<br />
beliebige Taste...
secun<strong>de</strong> acesta se opreste si porneste urmatorul agregat. Ordinea <strong>de</strong> test este: Aerator 1<br />
(Belüfter 1), Aerator 2 (Belüfter 2) – doar la Xl pana la 100 , Pompa <strong>de</strong> alimentare 1<br />
(Beschickung 1)- doar la PROFESSIONAL G, Pompa <strong>de</strong> alimentare 2 (Beschickung 2) – la<br />
XL pana la 125, Pompa <strong>de</strong> evacuare 1 (Klarwasserpumpe 1), Pompa <strong>de</strong> evacuare 2<br />
(Klarwasserpumpe 2)- doar la XL pana la 100, Pompa <strong>de</strong> namol ( Schlammpumpe)- exceptie<br />
la BASIC.<br />
Daca echipamentul dumneavoastra este dotat cu un AQUAswitch (BASIC) testul<br />
poate fi efectuat doar daca bazinul este plin si <strong>unitate</strong>a submersata sau scoasa<br />
afara.<br />
Testul agregatelor se poate opri oricand prin apasarea unei taste oarecare.<br />
ATENTIE! Daca un agregat nu functioneaza corespunzator, acest <strong>de</strong>ranjament nu<br />
este trecut in jurnal si nu apare nici un raport!<br />
Lista <strong>de</strong>ranjamentelor (Fehlerliste)<br />
Testlauf<br />
< Fehlerliste ><br />
Einstellungen<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
Fehler [ 0]<br />
Belüfter1<br />
Strom Min.<br />
↓ ↑ Info ESC<br />
Fehler [0 – 15]<br />
Fehler [ 0]<br />
Belüfter1<br />
inaktiv<br />
↓ ↑ Info ESC<br />
Fehler [0 – 15]<br />
Info<br />
ESC<br />
Fehler [ 0]<br />
Belüfter1<br />
12.05.06 12:25:33<br />
↓ ↑ Del ESC<br />
Fehler [ 0]<br />
Belüfter1<br />
Priorität = 3<br />
↓ ↑ Edit ESC<br />
Fehler [ 0]<br />
Belüfter1<br />
Zähler = 3<br />
↓ ↑ Del ESC<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
20 / 42<br />
Del<br />
Edit<br />
Del<br />
OK<br />
ESC<br />
Fehler [ 0]<br />
Belüfter1<br />
Kein Datum<br />
↓ ↑ Del ESC<br />
ESC<br />
Fehler [ 0]<br />
Belüfter1<br />
Priorität = 3<br />
↓ ↑ OK ESC<br />
Fehler [ 0]<br />
Belüfter1<br />
Zähler = 0<br />
↓ ↑ Del ESC<br />
ESC
Sunt posibile 16 cauze diferite <strong>de</strong> <strong>de</strong>ranjamente (0-15; lista in anexa). Cu ajutorul sagetilor<br />
poate fi aleasa fiecare cauza in parte. Daca <strong>de</strong>ranajmentul respectiv nu este cauza<br />
malfunctiunii apare in display „inaktiv”. Altfel apare cauza <strong>de</strong>ranjamentului (d.ex. Strom min =<br />
Amperaj min – amperajul agregatului este prea mic).<br />
ATENTIE! La resetarea unui <strong>de</strong>ranjament acesta este anulat si in display este<br />
indicat „inactiv”!<br />
Prin apasarea tastei „Info” obtineti informatii cu privire la ultima aparitie a acestui<br />
<strong>de</strong>ranjament. Prin apasarea tastei „DEL” este stearsa informatia si contorul.<br />
Prin apasarea tastei ↓ ajungeti la parametrul “Prioritate” (“Priorität”). Acest parametru<br />
hotaraste felul in care trebuie tratat <strong>de</strong>ranjamentul respectiv.<br />
Prioritatile <strong>de</strong>ranjamentelor:<br />
1 = Deranjamentul este indicat in display, dar nu este activata alarma acustica si<br />
<strong>de</strong>ranjamentul nu este directionat spre alta receptie (peste contactul fara potential<br />
incorporat, via GSM d.ex.). Deranjamentul este inregistrat in jurnalul electronic.<br />
2 = Deranjamentul este indicat in display, evt. alarmare acustica, releul <strong>de</strong> alarmare<br />
generala. Deranjamentul este inregistrat in jurnalul electronic si in lista<br />
<strong>de</strong>ranjamentelor.<br />
3 = In plus fata <strong>de</strong> prioritatea 2 – Releul <strong>de</strong> comunicare activ<br />
Cu ajutorul tastei „Edit” ajungeti in modul <strong>de</strong> setare si puteti schimba cu ajutorul sagetilor<br />
prioritatea unui <strong>de</strong>ranjament. Cu „OK” salvati schimbarile efectuate, cu „ESC” parasiti meniul<br />
fara a memora.<br />
ATENTIE! La setarea unui grad <strong>de</strong> prioritate fals nu este generata o alarma!<br />
In cazul in care se seteaza fara acordul firmei ATB prioritatea 1 pentru un<br />
<strong>de</strong>ranjament, atunci sunt excluse remedieri in garantie a <strong>de</strong>fectiunilor care<br />
ar putea sta in corelatie cu aceasta setare.<br />
Prin apasarea tastei ↓ ajungeti la parametrul “Zähler” (contor).<br />
Acesta memoreaza <strong>de</strong> cate ori a aparut <strong>de</strong>ranjamentul respectiv. Prin apasarea tastei “Del”<br />
se resetaza acest contor.<br />
Setari (Einstellungen)<br />
ATENTIE! Valoarea acestui contor se mareste cu 1 doar daca raportul<br />
<strong>de</strong>ranajmentului a fost activat prin resetarea <strong>de</strong>ranjamentului (retineti: daca<br />
apare un <strong>de</strong>ranjament, acesta va fi doar atunci inca o data inregistrat daca a<br />
fost receptionat si resetat la intaia aparitie).<br />
CLASSIC / PROFESSIONAL:<br />
Fehlerliste<br />
< Einstellungen ><br />
Stromgrenzen<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
Beschickung<br />
Dauer<br />
= 0,8 Minuten<br />
↓ ↑ EDIT ESC<br />
EDIT<br />
OK<br />
ESC<br />
Beschickung<br />
Dauer<br />
= 00,8 Minuten<br />
Pos Wert OK ESC<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
21 / 42
BASIC:<br />
Fehlerliste<br />
< Einstellungen ><br />
Stromgrenzen<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
Beschickung<br />
Anzahl<br />
= 5<br />
↓ ↑ EDIT ESC<br />
In spatele acestui meniu se gasesc toate posibilitatile <strong>de</strong> modificare a parametrilor <strong>de</strong><br />
operare. Acestia sunt incarcati automat in momentul in care se seteaza numarul <strong>de</strong> persoane<br />
racordate, dar pot fi modificati <strong>de</strong> catre firma montatoare daca este necesar. Prin apasarea<br />
tastei ↑ ajungeti pe rand la fiecare parametru modificabil.<br />
Cu tasta “Edit” ajungeti in modul <strong>de</strong> setare in care cu “Pos” ajungeti la pozitia dorita si cu<br />
“Wert” modificati valoarea respectiva. Cu “OK” confirmati si memorati modificarile efectuate,<br />
cu “ESC” parasiti meniul fara a memora modificarile.<br />
Durata/numar alimentari (BASIC Beschickung Anzahl)<br />
Acesta reprezinta timpul <strong>de</strong> functionare a pompei <strong>de</strong> alimentare (la BASIC numarul <strong>de</strong><br />
alimentari) a reactorului SBR. Apa din bazinul <strong>de</strong> stocare este trecuta in cel <strong>de</strong> tratare.<br />
(BASIC / CLASSIC: Retentie grosier / namol)<br />
Cu alimentarea porneste un nou ciclu. Frecventa in care are loc alimentarea este data <strong>de</strong> timpul <strong>de</strong> pauza intre<br />
doua alimentari si <strong>de</strong> lungimea unui ciclu. Ultima alimentare are loc cel tarziu la 2 ore inainte <strong>de</strong> inceperea fazei<br />
<strong>de</strong> sedimentare, pentru a putea garanta un timp suficient <strong>de</strong> epurare inainte <strong>de</strong> sedimentare.<br />
Daca sunt prevazuti 4 plutitori (posibil doar la PROFESSIONAL XL (standard) si G ) are loc in afara <strong>de</strong> setarea<br />
dupa timp, o alimentare cand plutitorul SW4 din bazinul <strong>de</strong> stocare inchi<strong>de</strong> si semnaleaza astfel un bazin plin si<br />
plutitorul SW2 din bazinul <strong>de</strong> tratare nu a inchis. Adica mai este suficient volum <strong>de</strong> stocare in bazinul SBR. Toate<br />
acestea doar atunci, inainte ca faza <strong>de</strong> sedimentare sa inceapa resp. mai sunt cel putin 2 ore pana la inceperea<br />
acesteia.<br />
Alimentarea face parte din faza <strong>de</strong> <strong>de</strong>nitrificare, adica odata cu inceperea alimentarii porneste faza <strong>de</strong><br />
<strong>de</strong>nitrificare.<br />
Pauza alimentare (Beschickung Pause)<br />
Timpul <strong>de</strong> pauza intre doua alimentari.<br />
EDIT<br />
OK<br />
ESC<br />
Durata <strong>de</strong>nitrificarii (Denitrifikation Dauer)<br />
Imediat dupa fiecare alimentare este prevazuta o faza <strong>de</strong> <strong>de</strong>nitrificare. Pentru aceasta faza<br />
pot fi prevazuti timpi <strong>de</strong> aerare diferiti, pentru a obtine un proces optim. Prin setarea valori 0<br />
este posibila functionarea instalatiei si fara <strong>de</strong>nitrificare.<br />
Denitrificare aerare pornita (Denitrifikation Belüftung ein)<br />
Timpul <strong>de</strong> aerare in faza <strong>de</strong> <strong>de</strong>nitrificare.<br />
Denitrificare aerare oprita (Denitrifikation Belüftung aus)<br />
Timpul <strong>de</strong> pauza intre doua aerari in faza <strong>de</strong> <strong>de</strong>nitrificare.<br />
Beschickung<br />
Anzahl<br />
= 005<br />
Pos Wert OK ESC<br />
Operare normala aerare pornita (Normalbetrieb Belüftung ein)<br />
Timpul <strong>de</strong> aerare in modul normal <strong>de</strong> operare.<br />
Dupa faza <strong>de</strong> <strong>de</strong>nitirificare urmeaza faza <strong>de</strong> aerare (nitrificare / eliminare carbon). Si in aceasta faza<br />
se lucreaza cu o aerare intermitenta.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
22 / 42
Operare normala aerare oprita (Normalbetrieb Belüftung aus)<br />
Timpul <strong>de</strong> pauza intre doua aerari in faza <strong>de</strong> operare normala.<br />
Durata sedminetare (Absetzen Dauer)<br />
Lungimea perioa<strong>de</strong>i <strong>de</strong> sedimentare dupa operarea normala.<br />
Daca a aparut o alarma <strong>de</strong> inundatie (SW2 si SW4 au cuplat), atunci timpul <strong>de</strong> sedimentare este<br />
injumatatit.<br />
Durata faza <strong>de</strong> aerare (Belüftungsphase Dauer)<br />
Durata ciclului <strong>de</strong> tratare (timpul intre prima alimentare [= start ciclu] si inceputul fazei <strong>de</strong><br />
sedimentare, <strong>de</strong>ci perioada <strong>de</strong> timp inclusiv alimentare si <strong>de</strong>nitrificare)<br />
Durata evacuare apa epurata (Klarwasserabzug Dauer)<br />
Dupa incheierea fazei <strong>de</strong> sedimentare are loc evacuarea apelor epurate. La ajungerea<br />
nivelului minim in bazinul SBR (Hw, min), care este semnalat <strong>de</strong> plutitorul <strong>de</strong> jos (SW1), se<br />
incheie evacuarea. In cazul in care, evacuarea apelor nu are loc in perioada <strong>de</strong> timp setata<br />
este activata o alarma „Deranjament [09] (Fehler) evacuare apa epurata, timp <strong>de</strong>pasit”.<br />
Durata evacuare namol (BASIC Schlammabzug Anzahl)<br />
PROFESSIONAL XL: Evacuarea namolului in exces incheie ciclul. Dupa evacuarea apei<br />
epurate intra in functiune pompa <strong>de</strong> evacuare namol pentru timpii setati.<br />
PROFESSIONAL G / BASIC / CLASSIC: Evacuarea namolului in exces are loc o singura<br />
data, in timpul fazei <strong>de</strong> aerare. Imediat dupa o perioada <strong>de</strong> aerare are loc evacuarea<br />
namolului pentru durata <strong>de</strong> timp setata. ( BASIC in functie <strong>de</strong> nr. alimentari)<br />
Atata vreme cat instalatia se afla in perioada <strong>de</strong> adaptare, namolul in exces nu este evacuat.<br />
Clatire pompe (Spülung Pumpen)<br />
La jumatatea fazei <strong>de</strong> sedimentare sunt activate pompele <strong>de</strong> evacuare. De trei ori pentru<br />
timpul setata si la un interval <strong>de</strong> un minut.<br />
Prin aceasta clatire a pompelor se evacueaza namolul <strong>de</strong>pus in carcasa. Astfel apele epurate evacuate sunt<br />
aproape fara sediment.<br />
Modul econom, aerare pornita (Sparmodus Belüftung ein)<br />
La <strong>AQUAmax</strong>® PROFESSIONAL: In cazul in care in bazinul <strong>de</strong> tratare este prea putina apa<br />
(SW1 = jos) inainte <strong>de</strong> inceperea fazei <strong>de</strong> sedimentare si/sau in bazinul <strong>de</strong> stocare este prea<br />
putina apa (SW3 = jos) astfel incat bazinul <strong>de</strong> tratare nu poate fi umplut, instalatia trece<br />
automat in modul <strong>de</strong> operare econom.<br />
<strong>AQUAmax</strong>® BASIC si CLASSIC: in cazul in care plutitorul (SW1) nu cupleaza cu doua ore<br />
inainte <strong>de</strong> faza <strong>de</strong> sedimentare echipamentul trece automat in modul <strong>de</strong> operare econom.<br />
Alimentarea urmeaza regulat.<br />
Aerarea este redusa la un minim suficient pentru a mai intretine activitatea biologica. Durata<br />
aerarii poate fi setata. Modul econom se incheie in momentul in care in bazinul <strong>de</strong> stocare<br />
este suficienta apa (PROFESSIONAL SW3 = sus) sau plutitorul s-a ridicat.<br />
(BASIC/CLASSIC:SW1 = sus)<br />
Modul econom, aerare oprita (Sparmodus Belüftung aus)<br />
Timpul <strong>de</strong> pauza intre doua aerari in modul <strong>de</strong> operare econom.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
23 / 42
Amperaj, valori limita (Stromgrenzen)<br />
Einstellungen<br />
< Stromgrenzen ><br />
Erweiterung<br />
↓ ↑ OK ESC<br />
Valorile setate pentru curentul electric al fiecarui agregat indica campul in care agregatele<br />
functioneaza corect. Daca <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> masoara un curent electric sub sau peste<br />
limita setata pentru un agregat, atunci este generata o alarma.<br />
ATENTIE! Daca curentul electric este sub limita <strong>de</strong> jos, agregatul va fi in<br />
continuare in functiune. Daca nu efectuati o resetare a raportului <strong>de</strong><br />
<strong>de</strong>ranjament generat, atunci acest <strong>de</strong>ranjament nu va mai fi inregistrat la o<br />
noua aparitie!<br />
Daca curentul electric este peste limita <strong>de</strong> sus a unui agregat, agregatul va fi<br />
oprit. Acesta nu poate fi repus in functiune atata vreme cat <strong>de</strong>ranjamentul nu<br />
este resetat.(Resetare auromata in 72 <strong>de</strong> ore)<br />
Cu tasta „Edit” ajungeti in modul <strong>de</strong> setare. Cu „Pos” alegeti pozitia si cu „Wert” modificati<br />
valoarea pozitiei respective. CU „Ok” se salveaza setarile efectuate, cu „ESC” parasiti meniul<br />
fara a salva schimbarile.<br />
Extin<strong>de</strong>re (Erwieterung)<br />
Stromgrenzen<br />
< Erweiterung ><br />
Werkseinstellung<br />
↓ ↑ OK ESC<br />
OK<br />
OK<br />
ESC<br />
ESC<br />
Parametrii special <strong>de</strong> setare pentru fiecare tip <strong>de</strong> instalatie in parte.<br />
Alimentare Deni (Beschickung Deni)<br />
Timpul pomparii (unice) <strong>de</strong> alimentare la instalatii CLASSIC.<br />
Pompare (Pumpenstoß)<br />
Intervalul <strong>de</strong> timp pentru pompariile care servesc alimentarii cu apa si a recircularii namolului<br />
in exces.<br />
Post operare (Nachlaufzeit)<br />
Stromgrenzen<br />
Beschicker1<br />
I= 5,0A ... 7,0A<br />
↓ ↑ EDIT ESC<br />
Protokoll RS232<br />
<br />
Pumpenstoß<br />
↓ ↑ OK ESC<br />
EDIT<br />
Edit<br />
Evacuarea este prelungita dupa atingerea nivelului minim Hwmin cu timpul setat, daca<br />
<strong>unitate</strong>a <strong>de</strong> epurare este prevazuta cu un plutitor AQUASwitch (BASIC).<br />
O comutare rapida dupa finalizarea procesului <strong>de</strong> evacuare este exclusa datorita histerezei<br />
mici a plutitorului.<br />
In<strong>de</strong>pen<strong>de</strong>nt <strong>de</strong> acestea la toate agregatele are loc o pauza <strong>de</strong> un minut intre sfarsitul si<br />
inceputul unui ciclu. Nici un agregat nu functioneaza in acest interval.<br />
Timpul <strong>de</strong> <strong>de</strong>clansare a <strong>de</strong>ranjamentelor (Fehlerauslösezeit)<br />
Stromgrenzen<br />
Beschicker1<br />
I= 05,0A ... 07,0A<br />
Pos Wert OK ESC<br />
La <strong>AQUAmax</strong>® PROFESSIONAL XL A/AA/AM aeratoarele resp. mixerele nu sunt comutate<br />
direct din <strong>ProControl</strong>.<br />
OK<br />
ESC<br />
ESC<br />
BechickungDeni<br />
Dauer<br />
=30 Sekun<strong>de</strong>n<br />
Edit ESC<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
24 / 42<br />
Edit<br />
OK<br />
ESC<br />
BechickungDeni<br />
Dauer<br />
= 30 Sekun<strong>de</strong>n<br />
Pos Wert Ok ESC
Cu iesirile Bel1 si Bel2 sunt coordonate releurile externe <strong>de</strong> siguranta. Acestea comuta<br />
sarcina pentru aerator, aeratorul resp. mixerul.<br />
Datorita faptului ca in acest caz nu este comutata direct sarcina, se <strong>de</strong>zactiveaza<br />
supravegherea tensiunii pentru iesirile Bel1 si Bel2. Alternativ se activeaza o alarmare<br />
externa.<br />
Alarmarea externa (potentialul N) la contactul 32 <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> poate distinge daca<br />
aeratorul 1 extern a cuplat. Prin alarmarea externa (potentialul N) la contactul 32 <strong>unitate</strong>a <strong>de</strong><br />
<strong>control</strong> poate distinge daca aeratorul 2 resp. mixerul a cuplat. (vezi pag. 35)<br />
Deregula alarmarea externa supravegheaza un automat <strong>de</strong> protectie pentru motor si un releu<br />
<strong>de</strong> siguranta.<br />
In stadiul comutat lantul <strong>de</strong> alarmare trebuie sa fie inchis. Daca lantul <strong>de</strong> alarmare este<br />
intrerupt in timpul functionarii aceasta duce la generarea unei alarme la sfarsitul timpului <strong>de</strong><br />
<strong>de</strong>clansare a <strong>de</strong>ranjamentelor.<br />
Protocol RS232 (Protokoll RS232)<br />
Fehlerauslösezeit<br />
< Protokoll RS232 ><br />
Beschickung Deni<br />
↓ ↑ OK ESC<br />
Jurnalul <strong>de</strong> functionare poate fi citit peste interfata RS232 aflata in panoul <strong>de</strong> <strong>control</strong>.<br />
Atentie! Nesesita cablu special. Cablurile normale pot <strong>de</strong>teriora <strong>unitate</strong>a <strong>de</strong><br />
<strong>control</strong>.<br />
Deregula interfata RS232 este libera. In cazuri speciale insa este necesara <strong>de</strong>cuplarea<br />
interfetei (tasta „Inaktiv”).<br />
Cu tasta „Info” sunt afisati parametrii setati ai interfetei.<br />
In cazul in care RS232 nu reactioneaza la comenzi se poate <strong>de</strong>puce faptul ca <strong>unitate</strong>a a fost<br />
scoasa din priza intr-un mod necorespunzator. (Software-Handshake). In cazul acesta<br />
interfata poate fi adusa din nou intr-un stadiu funcitonal apasand tasta „RST”. Datele care<br />
urmau sa fie prelucrate se intrerup.<br />
Setari din fabrica (Werkseinstellungen)<br />
Erwieterung<br />
<br />
Einfahren<br />
nein<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
Protokoll RS232<br />
aktiv<br />
inakt RST Info ESC<br />
inaktiv<br />
Protokol RS232<br />
inaktiv<br />
aktiv ESC<br />
OK<br />
ja<br />
nein<br />
Baudrate:19200<br />
Data Bits:8StopBit:1<br />
Parity:non<br />
beliebige Taste<br />
Prin intermediul tastei „ja” (da) sunt preluati parametrii corespunzatori statiei setate.<br />
Info<br />
aktiv RST<br />
Bitte wählen Sie<br />
Grun<strong>de</strong>instellungen<br />
ja nein<br />
Protokoll RS232<br />
Zurücksetzen…<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
25 / 42
Perioada <strong>de</strong> adaptare (Einfahren)<br />
Werkseinstellung<br />
< Einfahren ><br />
Phosphatfällung<br />
↓ ↑ OK ESC<br />
In primele saptamani <strong>de</strong> functionare a instalatiei <strong>de</strong> epurare trebuie sa se <strong>de</strong>zvolte mai intai<br />
namolul activ. In aceasta perioada nu are sens o evacuare a namolului in exces.<br />
Din acest motiv evacuarea namolului porneste doar dupa parcurgerea unui anumit numar <strong>de</strong><br />
cicluri. Setarea standard este <strong>de</strong> 270 <strong>de</strong> cicluri, ceea ce corespun<strong>de</strong>, la un ciclu <strong>de</strong> 8 ore,<br />
unei perioa<strong>de</strong> <strong>de</strong> timp <strong>de</strong> 90 <strong>de</strong> zile sau 3 luni.<br />
In acest meniu este indicat numarul <strong>de</strong> cicluri ramase pana cand este activata evacuarea<br />
namolului in exces.<br />
Cu „Edit” ajungeti in modul <strong>de</strong> setare. Cu „Pos” alegeti pozitia si cu „Wert” modificati valoarea<br />
pozitiei respective. CU „Ok” se salveaza setarile efectuate, cu „ESC” parasiti meniul fara a<br />
salva schimbarile.<br />
Precipitare fosfor (Phosphatfällung)<br />
Einfahren<br />
< Phosphatfällung ><br />
Dosierpumpe<br />
↓ ↑ OK ESC<br />
In acest meniu activati contacul fara potential 1 prevazut pentru precipitare fosfor. Peste<br />
acest contact poate fi dirijata o pompa <strong>de</strong> dozaj substanta floculanta.<br />
Dozajul se face in prima faza <strong>de</strong> aerare din ultima ora <strong>de</strong> tratare (1 ora inainte <strong>de</strong> faza <strong>de</strong><br />
sedimentare).<br />
Cu „OK” ajungeti in modul <strong>de</strong> setare, aici puteti activa sau <strong>de</strong>zactiva contactul apasand<br />
tastele corespunzatoare. Cu „ESC” parasiti meniul.<br />
ATENTIE! Contactul fara potential 1 poate fi utilizat pentru precipitare fosfor<br />
sau pentru <strong>de</strong>zinfectare cu UV. Odata cu activarea uneia dintre aceste variante<br />
va fi <strong>de</strong>zactivata cealalta (in cazul in care a fost activata)!<br />
ATENTIE! In cazul in care nu se utilizeaza un indicator al volumului <strong>de</strong><br />
umplere pentru substanta floculanta trebuie executat un pod electric <strong>de</strong><br />
legatura peste clemele 14 si 26 (vezi pag. 30).<br />
Pompa dozaj (Dosierpumpe)<br />
Phosphatfällung<br />
< Dosierpumpe ><br />
UV-Desinfektion<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
OK<br />
OK<br />
ESC<br />
ESC<br />
Einfahren<br />
Zähler<br />
= 263<br />
EDIT ESC<br />
Freigabe<br />
Phosphatfällung<br />
inaktiv<br />
aktiv ESC<br />
Dosierpumpe<br />
Einschaltdauer<br />
= 0 Sekun<strong>de</strong>n<br />
EDIT ESC<br />
EDIT<br />
Einfahren<br />
Zähler<br />
= 263<br />
Pos Wert OK ESC<br />
In acest meniu fixati timpul <strong>de</strong> dozaj al pompei activate in meniul anterior.<br />
Cu tasta „Edit” ajungeti in modul <strong>de</strong> setare. Cu „Pos” alegeti pozitia si cu „Wert” modificati<br />
valoarea pozitiei respective. Cu „Ok” se salveaza setarile efectuate, cu „ESC” parasiti meniul<br />
fara a salva schimbarile.<br />
Valorile presetate le gasiti in anexa.<br />
OK<br />
ESC<br />
aktiv<br />
inakt<br />
EDIT<br />
OK<br />
ESC<br />
Freigabe<br />
Phosphatfällung<br />
aktiv<br />
inakt ESC<br />
Dosierpumpe<br />
Einschaltdauer<br />
= 000 Sekun<strong>de</strong>n<br />
Pos Wert OK ESC<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
26 / 42
Dezinfectare UV (UV-Desinfektion)<br />
Dosierpumpe<br />
< UV-Desinfektion ><br />
Alarmkontakt<br />
↓ ↑ OK ESC<br />
OK<br />
ESC<br />
Cu activarea acestui meniu este pornita <strong>unitate</strong>a <strong>de</strong> ultraviolete pentru igienizarea apelor.<br />
Aceasta este pornita cu 5 min inainte <strong>de</strong> evacuarea apei si ramane activa alte 5 min dupa<br />
incheierea evacuarii. Cu „ESC” parasiti meniul.<br />
Durata <strong>de</strong> viata in medie a unei lampe UV este <strong>de</strong> 2.000 <strong>de</strong> cicluri sau 8.760 <strong>de</strong> ore. Aceasta<br />
corespun<strong>de</strong> unei perioa<strong>de</strong> <strong>de</strong> functionare in medie <strong>de</strong> 2 ani.<br />
Pe ecran sunt prezentate ciclurile <strong>de</strong> viata ramase. Dupa expirarea celor 2.000 <strong>de</strong> cicluri este<br />
generata o alarma (<strong>de</strong>ranjament 15 =Fehler 15).<br />
Pentru a anunta utilizatorul si serviciul <strong>de</strong> intretinere din timp in ceea ce priveste necesitatea<br />
schimbarii lampii UV este generata, dupa 1550 <strong>de</strong> cicluri (contor =450 [~ 150 <strong>de</strong> zile] o<br />
observatie pe ecranul unitatii<br />
Contorul <strong>de</strong> pe ecran poate fi resetat prin <strong>de</strong>zactivare si o noua activare dupa inlocuirea<br />
lampii UV (contor=2.000).<br />
Cu ESC parasiti meniul.<br />
UV-Desinfektion<br />
Freigabe = inaktiv<br />
aktiv ESC<br />
ATENTIE! Contactul fara potential 1 poate fi utilizat pentru precipitare fosfor<br />
sau pentru <strong>de</strong>zinfectare cu UV. Odata cu activarea uneia dintre aceste variante<br />
va fi <strong>de</strong>zactivata cealalta (in cazul in care a fost activata)!<br />
ACHTUNG! In cazul in care nu se utilizeaza un senzor pentru functionalitatea<br />
lampii UV trebuie executat un pod electric peste clemele14 si 26 (vezi pag. 30).<br />
Contactul fara potential (Alarmkontakt)<br />
Dosierpumpe OK Alarmkontakt<br />
< Alarmkontakt ><br />
nicht benutzt<br />
Service<br />
↓ ↑ OK ESC ESC EDIT ESC<br />
EDIT<br />
OK<br />
ESC<br />
In acest meniu activati contacul fara potential<br />
2 prevazut pentru <strong>de</strong>zinfectare UV. Peste<br />
acest contact poate fi dirijata o alarma externa.<br />
Cu tasta „Edit” ajungeti in modul <strong>de</strong> setare. Cu<br />
„Pos” alegeti pozitia si cu „Wert” modificati valoarea<br />
pozitiei respective. Cu „Ok” se salveaza<br />
setarile efectuate<br />
Cu ESC parasiti meniul.<br />
aktiv<br />
UV-Desinfektion<br />
inaktiv<br />
Freigabe = aktiv<br />
Zähler=2000(8760h)<br />
inaktiv RST ESC<br />
ESC<br />
Alarmkontakt<br />
nicht benutzt<br />
↓ ↑ OK ESC<br />
Alarmkontakt<br />
Schließer<br />
↓ ↑ OK ESC<br />
Alarmkontakt<br />
Öffner<br />
↓ ↑ OK ESC<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
27 / 42
Anexa date <strong>de</strong> operare<br />
Date si timpi <strong>de</strong> functionare preprogramati <strong>AQUAmax</strong>® PROFESSIONAL:<br />
Alimentare Denitrificare Mod op. normal Sedi-<br />
Evacuare Evacuare Clatire Mod econom Fosfor<br />
Tip Aerare Aerare mentare Aerare apa epurata namol Pompe Aerare Timp dozare<br />
Durata Pauza Dauer pornita oprita pornita oprita pornita oprita **<br />
[min] [h] [min] [sec] [min] [min] [min] [h] [h] [min] [sec] [sec] [min] [min] [sec]<br />
min/ma<br />
x* max 30 min 1,5 max 90 max 60 min 10 max 15 min 10 1 / 2 min 3 min 10 - 0,2 / 0,5 max 15 min 10 -<br />
G 02 0,4 3,2 41 15 10 2 15 1,5 6,4 20 2 0,2 2 15 3,6<br />
G 04 0,7 3,2 41 15 10 3 15 1,5 6,4 20 3 0,2 2 15 7,2<br />
G 06 1,1 3,2 42 15 10 4 15 1,5 6,4 20 5 0,2 2 15 10,8<br />
G 08 1,4 3,2 42 15 10 5 15 1,5 6,4 20 6 0,2 2 15 14,4<br />
G 10 1,8 3,2 42 15 10 6 15 1,5 6,4 20 8 0,2 3 15 18,0<br />
G 12 2,1 3,2 43 15 10 7 15 1,5 6,4 30 9 0,2 3 15 21,6<br />
G 16 2,8 3,2 43 15 10 6 15 1,5 6,4 40 12 0,2 4 15 28,8<br />
G 20 3,5 3,2 44 15 10 7 15 1,5 6,4 40 15 0,2 3 15 36,0<br />
G 24 4,2 3,2 45 15 10 8 15 1,5 6,4 50 18 0,2 4 15 43,2<br />
G 28 4,9 3,2 45 15 10 9 15 1,5 6,4 60 21 0,2 4 15 50,4<br />
G 32 5,6 3,2 46 15 10 11 15 1,5 6,4 20 10 0,2 5 15 57,6<br />
G 36 6,4 3,2 47 15 10 13 15 1,5 6,4 20 11 0,2 6 15 64,8<br />
G 40 7,1 3,2 48 15 10 14 15 1,5 6,4 20 12 0,2 7 15 72,0<br />
G 44 7,8 3,2 48 15 10 15 15 1,5 6,4 20 13 0,2 7 15 79,2<br />
G 48 8,5 3,2 49 15 10 15 13 1,5 6,4 30 14 0,2 8 15 86,4<br />
G 53 9,5 3,2 50 15 10 15<br />
1
Date si timpi <strong>de</strong> functionare preprogramati <strong>AQUAmax</strong>® CLASSIC / BASIC :<br />
Alimentare Denitrificare Mod op. normal<br />
Evacuare namol Clatire Mod econom Fosfor<br />
Sedi-<br />
Evacuare<br />
Tip BASIC CLASSIC Aerare Aerare mentare Aerare apa epurata BASIC CLASSIC Pompe Aerare Timp dozare<br />
Nr. Durata Pauza Dauer pornita oprita pornita oprita Nr. Durata pornita oprita **<br />
[sec] [h] [min] [sec] [min] [min] [min] [h] [h] [min] [sec] [sec] [min] [min] [sec]<br />
min/max* 4/9 4/30 1,5 / - - / 90 - / 60 10 / - 1 / 15 10 / - 1 / 2 3 / - 10 / 60 - 0,2 / 0,5 1 / 15 10 / - -<br />
2 5,0 7 2,0 41 15 10 2 15 2,0 6,0 20 1 2 0,2 2 15 3,6<br />
4 5,0 7 2,0 41 15 10 3 15 2,0 6,0 20 2 3 0,2 2 15 7,2<br />
6 5,0 7 2,0 42 15 10 4 15 2,0 6,0 20 3 5 0,2 2 15 10,8<br />
8 5,0 7 2,0 42 15 10 5 15 2,0 6,0 20 4 6 0,2 2 15 14,4<br />
10 5,0 7 2,0 42 15 10 6 15 2,0 6,0 20 5 8 0,2 3 15 18,0<br />
12 5,0 7 2,0 43 15 10 7 15 2,0 6,0 30 6 9 0,2 3 15 21,6<br />
14** 5,0 - 2,0 43 15 10 8 15 2,0 6,0 30 7 - 0,2 4 15 24,2<br />
16 5,0 7 2,0 43 15 10 8 15 2,0 6,0 40 8 12 0,2 4 15 28,8<br />
20 7 2,0 44 15 10 7 15 2,0 6,0 40 15 0,2 3 15 36<br />
24 7 2,0 45 15 10 8 15 2,0 6,0 50 18 0,2 4 15 43,2<br />
28 7 2,0 45 15 10 9 15 2,0 6,0 60 21 0,2 4 15 50,4<br />
32 7 2,0 46 15 10 11 15 2,0 6,0 20 10 0,2 5 15 57,6<br />
36 7 2,0 47 15 10 13 15 2,0 6,0 20 11 0,2 6 15 64,8<br />
40 7 2,0 48 15 10 14 15 2,0 6,0 20 12 0,2 7 15 72<br />
44 7 2,0 48 15 10 15 15 2,0 6,0 20 13 0,2 7 15 79,2<br />
48 7 2,0 49 15 10 15 13 2,0 6,0 30 14 0,2 8 15 86,4<br />
53 7 2,0 50 15 10 15 12 2,0 6,0 30 16 0,2 9 15 95,4<br />
* Valori setabile minime si maxime. ** doar BASIC<br />
Valori preprogramate pentru curentul electric <strong>AQUAmax</strong>® CLASSIC/BASIC:<br />
Tip Aerator 1 Aerator 2 Pompa alimentare 1 Pompa alimentare 2 Pompa evacuare 1 Pompa evacuare 2 Pompa namol<br />
[A] [A] [A] [A] [A] [A] [A]<br />
2<br />
4<br />
6<br />
8<br />
10<br />
12<br />
14<br />
16<br />
20<br />
24<br />
28<br />
32<br />
36<br />
40<br />
44<br />
48<br />
53<br />
0,7...1,9<br />
1,5...3,8**<br />
0,0...10,0 0,0...10,0 0,0...10,0<br />
0,4...1,2<br />
0,7…1,9**<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
29 / 42<br />
0,0...10,0<br />
0,0…10,0*<br />
0,4…1,2**<br />
0,7…1,9**
Semnalizarea <strong>de</strong>ranjamentelor (Mögliche Fehlermeldungen):<br />
ATENTIE! Alarma acustica si cea externa (daca cuplata la contactul fara<br />
potential) sunt oprite prin apasarea unei taste oarecare. Deranajmentul<br />
ramane insa indicat in display pana la resetare (Fehler-Reset). Dupa resetare<br />
<strong>de</strong>ranjamentul mai poate fi regasit doar in jurnalul electronic.<br />
La o noua aparitie a aceluiasi <strong>de</strong>ranjament acesta nu va mai fi indicat inca o data, daca<br />
nu efectuati o resetare a <strong>de</strong>ranjamentului. Pentru a garanta o operare optima si sigura,<br />
este obligatorie resetarea <strong>de</strong>ranjametului dupa receptionare (aceasta insemnand: Alle Fehler<br />
löschen? = ja = Stergeti toate <strong>de</strong>ranjamentele? = da). O resetare automata are loc dupa 72<br />
<strong>de</strong> ore.<br />
O resetare este trecuta in jurnalul electronic cu textul „inaktiv”. Dupa informarea firmei <strong>de</strong><br />
intretinere aceasta va lua masurile necesare pentru remedierea <strong>de</strong>ranjamentului.<br />
UVS (alarma acustica, fara indicare in display)<br />
UVS (Un<strong>de</strong>r Voltage Signaling / Semnalizare ca<strong>de</strong>re tensiune) este o componenta<br />
electronica integrata in <strong>unitate</strong>a <strong>de</strong> <strong>control</strong>. In cazul intreruperii curentului spre <strong>unitate</strong>a <strong>de</strong><br />
<strong>control</strong> si astfel spre instalatie, din cauza unei sigurante sau a ca<strong>de</strong>rii <strong>de</strong> tensiune, este<br />
<strong>de</strong>clansat un semnal acustic. Odata activat, acest semnal persista pentru cca. 24 <strong>de</strong> ore.<br />
Alarma se receptioneaza apasand o tasta oarecare. Alarma se <strong>de</strong>zactiveaza automat in<br />
momentul in care este din nou tensiune.<br />
Dupa o ca<strong>de</strong>re <strong>de</strong> tensiune (chiar si <strong>de</strong> scurta durata) si revenire a acesteia, perioada <strong>de</strong><br />
timp pana este reactivat semnalul UVS este <strong>de</strong> 4 ore.<br />
Unitate <strong>de</strong> <strong>control</strong> nefunctionala (nici o imagine pe ecran)<br />
Siguranta arsa. (inlocuiti siguranta cu cea <strong>de</strong> rezerva din capacul unitatii <strong>de</strong> <strong>control</strong>)<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
30 / 42
Text indicat in display (alarma acustica)<br />
Fehler [ 0]<br />
Belüfter1<br />
Strom Min.<br />
Quitt...<br />
Fehler [ 4]<br />
Klarwasserpumpe1<br />
Strom Min.<br />
Quitt...<br />
Cauza posibila<br />
Un agregat sau statia <strong>AQUAmax</strong>® nu sunt<br />
racordate.<br />
Una (sau toate) din legaturile <strong>de</strong> curent nu a<br />
fost bine efectuata, astfel incat se produc<br />
intreruperi.<br />
Cablul <strong>de</strong> legatura dintre aparatul electric si<br />
<strong>unitate</strong>a <strong>de</strong> <strong>control</strong> este intrerupt<br />
Siguranta din <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> a<br />
agregatului respectiv a sarit.<br />
Nivelul apei in bazin(e) este asa <strong>de</strong> scazut<br />
incat instalatia este uscata. Eventual sa<br />
efectuat vidanjarea si bazinele nu au fost<br />
reumplute.<br />
Agregatul corespunzator este <strong>de</strong>fect.<br />
Fehler [ 0]<br />
Belüfter1<br />
Strom Max.<br />
Quitt...<br />
Fehler [ 4]<br />
Klarwasserpumpe1<br />
Strom Max.<br />
Quitt...<br />
Cauza posibila<br />
Fehler [ 1]<br />
Belüfter2<br />
Strom Min.<br />
Quitt...<br />
Fehler [ 5]<br />
Klarwasserpumpe2<br />
Strom Min.<br />
Quitt...<br />
Fehler [ 1]<br />
Belüfter2<br />
Strom Max.<br />
Quitt...<br />
Fehler [ 5]<br />
Klarwasserpumpe2<br />
Strom Max.<br />
Quitt...<br />
Agregatul respectiv este infundat sau blocat<br />
sau se invarte greu.<br />
Fehler [ 2]<br />
Beschicker1<br />
Strom Min.<br />
Quitt...<br />
Fehler [ 6]<br />
Schlammpumpe<br />
Strom Min.<br />
Quitt...<br />
Remediere<br />
Conectati agregatul corespunzator.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
31 / 42<br />
Chemati firma <strong>de</strong> service sau lasati un<br />
electrician sa <strong>control</strong>eze cablul respectiv.<br />
Vezi mai sus.<br />
Schimbati siguranta. (Siguranta <strong>de</strong> rezerva in<br />
capac)<br />
Controlati nivelul apei. Umpleti instalatia cu<br />
apa. Controlati plutitoarele <strong>de</strong> comutare.<br />
Chemati firma <strong>de</strong> service.<br />
Fehler [ 2]<br />
Beschicker1<br />
Strom Max.<br />
Quitt...<br />
Fehler [ 6]<br />
Schlammpumpe<br />
Strom Max.<br />
Quitt...<br />
Remediere<br />
Fehler [ 3]<br />
Beschicker2<br />
Strom Min.<br />
Quitt...<br />
Fehler [ 3]<br />
Beschicker2<br />
Strom Max.<br />
Quitt...<br />
Scoateti instalatia din bazin si curatati /<br />
<strong>de</strong>sfundati agregatul.<br />
ATENTIE! Piese rotative! Deconectati instalatia <strong>de</strong> la sursa <strong>de</strong> curent inainte <strong>de</strong> a o<br />
extrage din bazin!
Fehler [ 7]<br />
Schwimmer Reaktor<br />
<strong>de</strong>fekt<br />
Quitt...<br />
Greseala logica. Plutitorul <strong>de</strong> sus inchi<strong>de</strong> si cel <strong>de</strong> jos este inca <strong>de</strong>schis (atentie la statutul<br />
plutitoarelor indicat in display)<br />
Cauza posibila<br />
Remediere<br />
Plutitorul este <strong>de</strong>fect sau este intrerupt cablul Chemati firma <strong>de</strong> service.<br />
<strong>de</strong> alimentare.<br />
Plutitorul s-a blocat si nu se ridica. Controlati plutitorul, acesta nu are voie sa se<br />
agate.<br />
Una (sau toate) din legaturile <strong>de</strong> curent nu a Chemati firma <strong>de</strong> service sau lasati un<br />
fost bine efectuata, astfel incat se produc electrician sa <strong>control</strong>eze cablul respectiv.<br />
intreruperi.<br />
Fehler [ 9]<br />
Klarwasserabzug<br />
Zeitüberschreitung<br />
Quitt...<br />
Fehler [ 8]<br />
Schwimmer Puffer<br />
<strong>de</strong>fekt<br />
Quitt...<br />
Fehlern (9) = Evacuarea apei epurate dureaza mai mult <strong>de</strong>cat timpul maxim setat. Plutitorul<br />
<strong>de</strong> jos din bazinul SBR [SW1] nu ca<strong>de</strong> (Atentie la statutul plutitoarelor indicat in display).<br />
Cauza posibila Remediere<br />
Plutitorul [SW1] este <strong>de</strong>fect. Chemati firma <strong>de</strong> service.<br />
Plutitorul [SW1] este blocat. Controlati plutitorul, acesta nu are voie sa se<br />
O legatura in panoul electric nu a fost facuta<br />
corect. Eventual nu este bine strans un surub<br />
si cablul nu face contact sau este intrerupt.<br />
agate.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
32 / 42<br />
Chemati firma <strong>de</strong> service sau lasati un<br />
electrician sa <strong>control</strong>eze cablul respectiv.<br />
Cablul <strong>de</strong> legatura este intrerupt. Vezi mai sus.<br />
Pompa <strong>de</strong> evacuare nu are <strong>de</strong>bit suficient. Controlati <strong>de</strong>bitul pompei trecand in modul <strong>de</strong><br />
operare manual. Evt. trebuie curatata pompa.<br />
Daca trebuie schimbata, chemati firma <strong>de</strong><br />
Neetanseitati in conducta <strong>de</strong> evacuare.<br />
Conducta <strong>de</strong> evacuare nu este fixata<br />
corespunzator la pompa.<br />
service.<br />
Schimbati conducta. Fixati conducta <strong>de</strong><br />
evacuare corespunzator.<br />
Apa curge inapoi in instalatie. Controlati evacuarea. In<strong>de</strong>partati cauza<br />
infundarii.<br />
Nivelul <strong>de</strong> apa in bazinul <strong>de</strong> tratare este Controlati rezervorul. Acesta trebuie sa fie<br />
ridicat. In instalatie ajunge mai multa apa sau etans. Constatati <strong>de</strong> un<strong>de</strong> vine surplusul <strong>de</strong><br />
nu este etans rezervorul.<br />
apa.<br />
Valoarea setata pentru timpul <strong>de</strong> evacuare Corectati valoarea. Ridicati timpul <strong>de</strong><br />
este falsa.<br />
evacuare.
Fehler [10]<br />
Hochwasser<br />
max. Niveau<br />
Quitt...<br />
Fehler (10) = Inundatie; Volumul maxim in bazinul <strong>de</strong> stocare este atins. Plutitorul <strong>de</strong> sus<br />
[SW4] a inchis. Volumul maxim in bazinul <strong>de</strong> tratare este atins (SW2 a inchis). Atentie la<br />
indicatorul plutitoarelor in display.<br />
Cauza posibila<br />
Remediere<br />
Apa curge inapoi in instalatie. Controlati evacuarea. In<strong>de</strong>partati cauza<br />
infundarii.<br />
In instalatie ajunge mai multa apa sau nu Controlati rezervorul. Acesta trebuie sa fie<br />
este etans rezervorul.<br />
etans. Constatati <strong>de</strong> un<strong>de</strong> vine surplusul <strong>de</strong><br />
apa.<br />
Bazinul <strong>de</strong> stocare este dimensionat prea Instalati un bazin <strong>de</strong> stocare suplimentar.<br />
mic.<br />
Fehler [11]<br />
max. 7Beschickung<br />
uberschritten<br />
Quitt...<br />
Plutitorul <strong>de</strong> jos din bazinul SBR (SW1) nu s-a activat nici dupa faza a saptea a alimentarii.<br />
Cauza posibila<br />
Remediere<br />
Pompa <strong>de</strong> alimentare <strong>de</strong>fecta. Controlati pompa si in caz <strong>de</strong> necesitate<br />
inlocuiti-o.<br />
Plutitorul SW1 sau SW3 este <strong>de</strong>fect respectiv Verificati plutitoarele si inlaturati cauza<br />
blocat.<br />
blocajului sau in caz <strong>de</strong> necesitate inlocuti<br />
plutitorii.<br />
Teava <strong>de</strong> alimentate este intrerupta sau<br />
infundata.<br />
Desfundati teava.<br />
Timpii <strong>de</strong> alimentare sunt prea scurti. Corectati setarile pentru timpii <strong>de</strong> alimentare.<br />
Fehler [12]<br />
Fällmittel<br />
Quitt...<br />
Fehler (12) = In cazul in care se foloseste <strong>unitate</strong>a <strong>de</strong> precipitare fosfor: Nivelul minim in<br />
recipientul cu substanta floculanta este atins.<br />
Cauza posibila<br />
Remediere<br />
Substanta floculanta a fost epuizata. Umpleti sau schimbati recipientul.<br />
O legatura in panoul electric nu a fost facuta<br />
corect. Eventual nu este bine strans un surub<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
33 / 42<br />
ATENTIE! Daca nu este montat un<br />
indicator <strong>de</strong> nivel, atunci peste clemele<br />
14 si 26 (V-/P) trebuie executat un pod<br />
electric <strong>de</strong> legatura.<br />
Chemati firma <strong>de</strong> service sau lasati un<br />
electrician sa <strong>control</strong>eze cablul respectiv.
si cablul nu face contact sau este intrerupt.<br />
Fehler [13]<br />
12V-Versorgung<br />
Quitt...<br />
Fehler (13) = Sursa interna <strong>de</strong> 12V (plutitoare) este <strong>de</strong>fecta.<br />
Cauza posibila<br />
Sursa interna <strong>de</strong> 12V (plutitoare) este<br />
<strong>de</strong>fecta.<br />
Fehler [14]<br />
UV-Lampe <strong>de</strong>fekt<br />
Quitt...<br />
Fehler (14) = Lampa <strong>de</strong> ultraviolete este <strong>de</strong>fecta<br />
Cauza posibila<br />
Remediere<br />
Chemati firma <strong>de</strong> service.<br />
Remediere<br />
Cablul <strong>de</strong> legatura este intrerupt. Chemati firma <strong>de</strong> service sau lasati un<br />
electrician sa verifice contactii si cablurile.<br />
Contactul <strong>de</strong> atentionare <strong>de</strong>ranjament indica Chemati firma <strong>de</strong> service.<br />
(Lampensensor- senzorul lampii)<br />
Fehler [15]<br />
UV-Lampe Service<br />
Quitt...<br />
Fehler (15) = Lampa <strong>de</strong> ultraviolete a atins numarul maxim <strong>de</strong> utilizari.<br />
Cauza posibila<br />
S-a atins numarul maxim <strong>de</strong> utilizari al lampii<br />
UV<br />
Remediere<br />
Chemati firma <strong>de</strong> service.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
34 / 42<br />
ATENTIE! Daca nu este montat un senzor<br />
pentru functionalitatea lampii UV, atunci<br />
peste clemele 14 si 26 (V-/P) trebuie<br />
executat un pod electric <strong>de</strong> legatura.
Date tehnice:<br />
Carcasa: IP65, 280x220x80 mm<br />
Interval temperatura: -10°C ... +50°C<br />
Tensiune operare: 185...245V, 50...60Hz<br />
Putere la sursa: < 25 VA<br />
Putere max. racord iesire: 1.400 VA<br />
Putere max. totala: 3.500 VA<br />
Contacte fara potential: 230 V~ / 8 A / 1.500 VA<br />
Releu <strong>de</strong> raportare (RR1...RR4): 200 V ~ / 0,5 A / 10 W<br />
Tensiune <strong>de</strong> iesire V+/V-: 5 V / 0,2 A<br />
Iesire analoga AO/Gnd: 0...10 V<br />
Intrare analoga AI/Gnd: 0...10 V<br />
Acumulator: NiMH, 4.8V, 80mAH; Durata <strong>de</strong> viata: 1000 Incarcari / Descarcari<br />
Sub tensiune: min. 6 ani |25°<br />
Sub tensiune: min. 3 ani |45°<br />
Platina<br />
Siguranta <strong>unitate</strong><br />
TR5; T0,63A<br />
Siguranta pt. agregate<br />
5x20; T6,3A<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
35 / 42<br />
- Clemele 34-36 (N01/C01/NC1):<br />
contact fara potential 1 (Pompa<br />
dozaj substanta floculanta sau<br />
lampa UV)<br />
- Clemele.14/26 (V-/P): Nivel<br />
substanta floculanta sau<br />
senzorul lampii UV (daca nu<br />
este disponibil executare pod!)<br />
- Clemele 22-24 (N02/C02/NC2):<br />
Contact fara potential 2<br />
(Alarma)<br />
Clemeke 32-33: alarma externa<br />
aerator 1 / mixer (33) la<br />
PROFESSIONAL XL A/AA/AM<br />
[comutati inspre zero (N)!]<br />
ATENTIE! Intrerupeti curentul electric catre <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> inainte <strong>de</strong> a o<br />
<strong>de</strong>schi<strong>de</strong>. Lucrarile la <strong>unitate</strong>a <strong>de</strong> <strong>control</strong> sub tensiune se vor executa doar <strong>de</strong><br />
un electrican calificat!
Semnalizarea aprofundata a <strong>de</strong>ranjamentelor:<br />
Unitatea proControl® <strong>de</strong>tine 4 releuri tip Reed (inchizatoare) pentru transmiterea <strong>de</strong>ranjamentelor<br />
la distanta. Acestea sunt folosite pentru transmiterea <strong>de</strong>ranjamentelor cu ajutorul<br />
unui mo<strong>de</strong>m - GSM (SMS sau E-mail).<br />
Contactele sunt inchise in modul normal, adica cand nu sunt <strong>de</strong>ranjamente. Fara tensiune<br />
(d.ex. la ca<strong>de</strong>rea tensiunii) sunt toate contactele <strong>de</strong>schise. Cu aceste 4 contacte este<br />
posibila semnalizarea a 16 statute diferite. (prezentare binara)<br />
Blocul <strong>de</strong> cleme<br />
Statuturi posibile pentru releurile-Reed<br />
Dez.-<br />
Cod<br />
Hex-<br />
Cod<br />
Cod binar<br />
RR4 RR3 RR2 RR1<br />
Descriere<br />
0 0x00 0 0 0 0 Ca<strong>de</strong>re tensiune (Unitatea <strong>de</strong> <strong>control</strong> oprita)<br />
1 0x01 0 0 0 1 Aerator 1 <strong>de</strong>fect (extern)<br />
2 0x02 0 0 1 0 Aerator 2 resp. mixer <strong>de</strong>fect (daca este montat)<br />
3 0x03 0 0 1 1 Pompa evacuare 1 <strong>de</strong>fecta<br />
4 0x04 0 1 0 0 Pompa evacuare 2 <strong>de</strong>fecta (daca este montata)<br />
5 0x05 0 1 0 1 Pompa alimentare 1 <strong>de</strong>fecta<br />
6 0x06 0 1 1 0 Pompa alimentare 2 <strong>de</strong>fecta (daca este montata)<br />
7 0x07 0 1 1 1 Pompa <strong>de</strong> namol <strong>de</strong>fecta<br />
8 0x08 1 0 0 0 Inundatie (toate 4 plutitoarele sunt sus)<br />
9 0x09 1 0 0 1 Depasire timp pentru pompa <strong>de</strong> evacuare<br />
10 0x0A 1 0 1 0<br />
Defectiune plutitoare (ordine <strong>de</strong> cuplare, greseala<br />
logica)<br />
11 0x0B 1 0 1 1 Sursa <strong>de</strong> 12V este <strong>de</strong>fecta<br />
12 0x0C 1 1 0 0 Numarul maxim <strong>de</strong> alimentari a fost <strong>de</strong>pasit<br />
13 0x0D 1 1 0 1 Intervalul <strong>de</strong> service a expirat<br />
14 0x0E 1 1 1 0 Nivel substanta floculanta sau <strong>de</strong>fectiune lampa UV.<br />
15 0x0F 1 1 1 1<br />
Nici un <strong>de</strong>ranjament / Unitatea <strong>de</strong> <strong>control</strong> functioneaza<br />
normal.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
36 / 42<br />
RR1 (Clemele 20/21)<br />
Releuri-Reed 1<br />
RR2 (Clemele 18/19)<br />
Releuri- Reed 2<br />
RR3 (Clemele 16/17)<br />
Releuri- Reed 3<br />
RR4 (Clemele 1/2)<br />
Releuri- Reed 4<br />
Q (Clema 25)<br />
receptionare externa<br />
V- (Clemele 14 sau 15<br />
tensiune pentru<br />
receptionare externa<br />
Sectiune max. cabluri 0,5<br />
mm 2
Standard sunt toate contactele releurilor Reed inchise. Este indicate imaginea standard <strong>de</strong><br />
statut. (In tabelul <strong>de</strong> mai sus un 1 inseamna ca releul respectiv este inchis. Un 0 inseama ca,<br />
contactul respectiv este <strong>de</strong>schis).<br />
La aparitia unuia sau a mai multor <strong>de</strong>ranjamente care nu au fost receptionate este indicat in<br />
display doar <strong>de</strong>ranjamentul cu numarul <strong>de</strong> ordine cel mai mic [0…14]. In plus este activat<br />
semnalul acustic. Statutul instalatiei nu mai este indicat in display. Simultan se schimba si<br />
statutul releurilor Reed.<br />
ATENTIE! Doar daca s-a setat in lista <strong>de</strong>ranjamentelor (Service-Mo<strong>de</strong>) prioritatea 3<br />
(valoarea standard) pentru un <strong>de</strong>ranjament anume, atunci acesta este semnalat<br />
prin intermediul releului Reed.<br />
In cazul in care <strong>de</strong>ranjamentele nu sunt resetate, releurile <strong>de</strong> semnalizare indica<br />
doar <strong>de</strong>ranjamentul cu numarul cel mai mic.<br />
Deranjamentele care apar in modul <strong>de</strong> operare manual sunt indicate doar in display.<br />
Daca este setata prioritatea corespunzatoare atunci <strong>de</strong>ranjamentul este insotit si <strong>de</strong><br />
un semnal acustic. Releurile <strong>de</strong> semanlizare si contactul fara potential pentru<br />
alarma externa nu semnalizeaza in nici un caz, indiferent <strong>de</strong> prioritatea setata,<br />
<strong>de</strong>ranjamentele care apar in modul <strong>de</strong> operare manual.<br />
Deranjamentul sau <strong>de</strong>ranjamentele pot fi receptionate la fata locului prin apasarea unei taste<br />
oarecare sau <strong>de</strong> la distanta prin semnal extern (d.e. mo<strong>de</strong>m GSM). Pentru receptionarea <strong>de</strong><br />
la distanta (ex. Mo<strong>de</strong>m GSM) trebuie cuplat semnalul <strong>de</strong> la clema V- (clemele 14 sau 15) cu<br />
intrarea Q (25) (contact fara potential).<br />
In cazul in care nu apare un <strong>de</strong>ranjament cu o prioritate secundara, se opreste semnalul<br />
acustic. Daca toate alarmele au fost receptionate, atunci in display apare statutul instalatiei.<br />
Acesta alterneaza cu indicarea <strong>de</strong>ranjamentelor receptionate.<br />
ATENTIE! Deranjamentele receptionate pot fi resetate doar <strong>de</strong> la <strong>unitate</strong>a <strong>de</strong><br />
<strong>control</strong> !<br />
Acelasi <strong>de</strong>ranjament este doar atunci inca o data indicat, daca a fost<br />
efectuata resetarea inainte sau daca apare dupa el un <strong>de</strong>ranjament cu numar<br />
<strong>de</strong> ordine mai mare!<br />
Resetarea automata are loc doar dupa 72 <strong>de</strong> ore.<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
37 / 42
In<strong>de</strong>x alfabetic <strong>unitate</strong> <strong>de</strong> <strong>control</strong> (Germana-Romana)<br />
Text in display<br />
Absetzen Dauer : Durata sedimentare<br />
Aktiv : Activ (contact sau meniu activat)<br />
Alle Fehler löschen? : In<strong>de</strong>partati toate <strong>de</strong>ranjamentele (resetare)<br />
An : Pornit<br />
Aus : Oprit<br />
Beliebige Taste : Tasta (buton) oarecare<br />
Belüften : Aerare<br />
Belüfter 1...x : Aerator 1...x<br />
Belüftungsphase Dauer : Durata faza aerare<br />
Beschickung : Alimentare, umplere<br />
Betriebszähler : Contor timp <strong>de</strong> functionare<br />
Bitte Co<strong>de</strong> eingeben : Setati codul <strong>de</strong> acces<br />
Bitte wählen Sie Anlagengröße : Alegeti marimea instalatiei<br />
Bitte wählen Sie die Seriennummer : Setati numarul <strong>de</strong> serie<br />
Datum : Data<br />
Datum / Uhr stellen : Fixati data si ora<br />
Dauer : Durata<br />
Denitrifikation Belüftung aus : Denitrificare aerare oprita<br />
Denitrifikation Belüftung ein : Denitrificare aerare pornita<br />
Denitrifikation Dauer : Durata <strong>de</strong>nitrificare<br />
Dosierpumpe : Pompa <strong>de</strong> dozaj<br />
Dosierpumpe Einschaltdauer : Durata <strong>de</strong> functionare pompa <strong>de</strong> dozaj<br />
Einfahren : Perioada <strong>de</strong> adaptare<br />
Einstellungen : Setari<br />
Fällmittel : Substanta floculanta<br />
Fehler (0...15) : Deranjament (0...15)<br />
Fehlerliste : Lista <strong>de</strong>ranjamentelor<br />
Fehler-Reset : Resetare <strong>de</strong>ranjamente<br />
Freigabe : Acitvare (liber <strong>de</strong> operare)<br />
Freigabe Phosphatfällung : Activare precipitare fosfor<br />
Freigabe UV-Desinfektion : Acitvare lampa <strong>de</strong> ultraviolete<br />
Grun<strong>de</strong>instellungen korrekt : Setarile <strong>de</strong> baza corecte?<br />
Hand-Modus : Modul manual <strong>de</strong> operare<br />
Hochwasser : Inundatie<br />
Inaktiv : Inactiv<br />
Info : Informatii <strong>de</strong>spre instalatie (tip, marime)<br />
Ja : Da<br />
kein Datum : Nu este data<br />
Klarwasserabzug Dauer : Durata evacuare apa epurata<br />
Depasire durata timp setata pt. evacuare apa<br />
Klarwasserabzug Zeitüberschreitung : epurata<br />
Klarwasserpumpe : Pompa evacuare apa epurata<br />
Logbuch : Jurnal electronic<br />
max. Niveau : Nivel maxim<br />
Meldung : Raport<br />
Nein : Nu<br />
Nicht benutzt : NU este folosit<br />
Normalbetr. : Operare normala<br />
Normalbetrieb Belüftung aus : Operare normala aerare oprita<br />
Normalbetrieb Belüftung ein : Operare normala aerare pornita<br />
Öffner : Deschizator<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
38 / 42
Pause : Pauza<br />
Phosphatfällung : Precipitare fosfor<br />
pot. Kontakt : contact fara potential<br />
Priorität : Prioritate<br />
Quitt... : Receptionare<br />
Schlammabzug Dauer : Durata evacuare namol in exces<br />
Schlammpumpe : Pompa <strong>de</strong> namol<br />
Schließer : Inchizator<br />
Schwimmer : Plutitor<br />
Schwimmer Puffer : Plutitor bazinul <strong>de</strong> stocare<br />
Schwimmer Reaktor : Plutitor bazinul <strong>de</strong> tratare<br />
Schwimmerschalter : Plutitor comutator (Flotor)<br />
Service Mo<strong>de</strong> : Modul <strong>de</strong> service (acces firma montatoare)<br />
Sparmodus Belüftung aus : Modul econom aerarea oprita<br />
Sprache wählen : Alegeti limbajul dorit<br />
Spülung Pumpen : Clatire pompe<br />
Strom max. : Curent maxim<br />
Strom min. : Curent minim<br />
Stromgrenzen : Valori granita pentru curent<br />
Tageswert : Valoarea zilnica (contor)<br />
Testlauf : Testul agregatelor<br />
Uhrzeit : Ora<br />
UV-Desinfektion : Dezinfectare cu ultraviolete<br />
UV-Lampe <strong>de</strong>fekt : Lampa <strong>de</strong> UV este <strong>de</strong>fecta<br />
Zähler : Contor<br />
12V-Versorgung : Sursa <strong>de</strong> 12V (pt. Plutitoare)<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
39 / 42
In<strong>de</strong>x alfabetic <strong>unitate</strong> <strong>de</strong> <strong>control</strong> (Engleza-Romana)<br />
Text in display<br />
Duration of sedimentation : Durata sedimentare<br />
Activ : Activ (contact sau meniu activat)<br />
Delete all errors? : In<strong>de</strong>partati toate <strong>de</strong>ranjamentele (resetare)<br />
On : Pornit<br />
Off : Oprit<br />
Any key : Tasta (buton) oarecare<br />
Aerator : Aerator<br />
Aerator 1...x : Aerator 1...x<br />
Duration of aeration phase : Durata faza aerare<br />
Feeding : Alimentare, umplere<br />
Run-time meter : Contor timp <strong>de</strong> functionare<br />
Please enter co<strong>de</strong> : Setati codul <strong>de</strong> acces<br />
Please select plant size : Alegeti marimea instalatiei<br />
Please select serial number : Setati numarul <strong>de</strong> serie<br />
Date : Data<br />
Date / time : Fixati data si ora<br />
Duration : Durata<br />
Denitrification aeration OFF : Denitrificare aerare oprita<br />
Denitrification aeration ON : Denitrificare aerare pornita<br />
Duration of <strong>de</strong>nitrification : Durata <strong>de</strong>nitrificare<br />
Dosing pump : Pompa <strong>de</strong> dozaj<br />
Dosing pump runtime : Durata <strong>de</strong> functionare pompa <strong>de</strong> dozaj<br />
Run-up : Perioada <strong>de</strong> adaptare<br />
Settings : Setari<br />
Coagulant : Substanta floculanta<br />
Error (0...15) : Deranjament (0...15)<br />
Error list : Lista <strong>de</strong>ranjamentelor<br />
Error-Reset : Resetare <strong>de</strong>ranjamente<br />
Activation : Acitvare (liber <strong>de</strong> operare)<br />
Activation phosphate coagulation : Activare precipitare fosfor<br />
Activation UV-Desinfection : Acitvare lampa <strong>de</strong> ultraviolete<br />
Main settings correct? : Setarile <strong>de</strong> baza corecte?<br />
<strong>Manual</strong> mo<strong>de</strong> : Modul manual <strong>de</strong> operare<br />
High water operation : Inundatie<br />
In Or<strong>de</strong>r : Inactiv<br />
Info : Informatii <strong>de</strong>spre instalatie (tip, marime)<br />
Yes : Da<br />
no Date : Nu este data<br />
Discharge of clarified water duration : Durata evacuare apa epurata<br />
Depasire durata timp setata pt. evacuare apa<br />
Discharge of clarified water excee<strong>de</strong>d time limit : epurata<br />
Clarified water pump : Pompa evacuare apa epurata<br />
Logbook : Jurnal electronic<br />
max. Niveau : Nivel maxim<br />
Message : Raport<br />
No : Nu<br />
Not in use : NU este folosit<br />
Normal operation. : Operare normala<br />
Normal operation aeration OFF : Operare normala aerare oprita<br />
Normal operation aeration ON : Operare normala aerare pornita<br />
Normally open : Deschizator<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
40 / 42
Brake : Pauza<br />
Phosphate coagulation : Precipitare fosfor<br />
Potential-free contact : contact fara potential<br />
Priority : Prioritate<br />
Quitt : Receptionare<br />
Duration of sludge removal : Durata evacuare namol in exces<br />
Sludg pump : Pompa <strong>de</strong> namol<br />
Normally closed : Inchizator<br />
Float swich : Plutitor<br />
Float swich buffer : Plutitor bazinul <strong>de</strong> stocare<br />
Float swich reactor : Plutitor bazinul <strong>de</strong> tratare<br />
Float swich : Plutitor comutator (Flotor)<br />
Service Mo<strong>de</strong> : Modul <strong>de</strong> service (acces firma montatoare)<br />
Economic mo<strong>de</strong> aeration OFF : Modul econom aerarea oprita<br />
Select language : Alegeti limbajul dorit<br />
Flushing of pumps : Clatire pompe<br />
Max current : Curent maxim<br />
Min. current : Curent minim<br />
Current limits : Valori granita pentru curent<br />
Daily value : Valoarea zilnica (contor)<br />
Operation test : Testul agregatelor<br />
Time : Ora<br />
UV-Desinfection : Dezinfectare cu ultraviolete<br />
UV-Lamp out of or<strong>de</strong>r : Lampa <strong>de</strong> UV este <strong>de</strong>fecta<br />
Counter : Contor<br />
12V-DC supply : Sursa <strong>de</strong> 12V (pt. Plutitoare)<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
41 / 42
Declaratia <strong>de</strong> conformitate<br />
Producatorul: ATB Umwelttechnologien GmbH<br />
Südstr. 2<br />
D-32457 Porta Westfalica<br />
Declara prin prezenta ca utilajul <strong>de</strong>scris<br />
alaturat<br />
Unitate <strong>de</strong> <strong>control</strong> proControl ©<br />
In<strong>de</strong>plineste cerintele referitor la siguranta<br />
si sanatatea la utilizare a urmatoarelor<br />
normative europene:<br />
Norme armonizate aplicate:<br />
DIN EN 1050<br />
DIN EN 61000-6-4<br />
DIN EN 61000-6-1<br />
DIN EN 61000-3-2<br />
BGV A3<br />
DIN VDE 0100<br />
DIN VDE 0660<br />
DIN EN 61000-6-2<br />
DIN EN 55011<br />
ATB Umwelttechnologien Romania SRL<br />
Internet: www.aquamax.ro Email: info@ro.aquamax.net<br />
42 / 42<br />
89/336/EEC Agreabilitate<br />
electromagnetica<br />
73/23/EEC Directiva pentru<br />
tensiuni joase<br />
Evaluarea riscurilor<br />
Agreabilitatea electromagnetica (EMC)<br />
Norme tehnice <strong>de</strong> baza<br />
Norme nationale aplicate si specificatii tehnice:<br />
9.GPSGV<br />
Directiva nr. 9 referitor la siguranta<br />
aparatelor<br />
Instalatii electrice si utilitati<br />
Constructia instalatiilor electrice cu tensiune<br />
pana in 1000 V<br />
Aparate <strong>de</strong> comutare la tensiune joasa<br />
Modificari constructive, care au repercursiuni asupra datelor tehnice <strong>de</strong>scrise<br />
in manualul <strong>de</strong> utilizare si a utilizarii corespunzatoare, care modifica masina<br />
substantial duc la anularea acestei <strong>de</strong>claratii <strong>de</strong> conformitate!<br />
Porta Westfalica, <strong>de</strong>n 15.05.2008<br />
Markus Baumann (Geschäftsführer)