AND-ALONE IN NETWORK<br />

STAND-ALONE IN NETWORK<br />

CENTRALIZED<br />

Art. F04420 Art. F04410<br />

Controller<br />

Up to 32 Readers<br />

twisted pair<br />

Technical features<br />

Controller stand-alone in network<br />

48<br />

CAC Central Unit centralized<br />

CAC Zentralisierte <strong>System</strong>e<br />

2 wires<br />

( restricted area )<br />

PRIVATE ACCESS CONTROL<br />

( restricted area )<br />

1 2 3<br />

PRIVATE ACCESS CONTROL<br />

4 5 6<br />

7 8 9<br />

A 0 B<br />

Reader<br />

Central Unit<br />

(ref.4410)<br />

Readers<br />

2 wires<br />

Power supply 12 Vdc<br />

twisted pair<br />

2 wires<br />

twisted pair<br />

2 wires<br />

twisted pair<br />

twisted 2 wires pair<br />

twisted pair<br />

2 wires<br />

twisted pair<br />

2 wires<br />

2 wires<br />

stand-alone in network<br />

Up to 64 Central Units<br />

twisted pair<br />

Technical features<br />

Technical Reader features<br />

F04410 Central Unit CAC that Unit lets you approach complex access control<br />

Technische installations Daten: handling up to 32 accesses or doors with a<br />

Door • Anbindung controller anwith Netzwerk 500 event F01087 memory (IP Interface) (ref.44201).<br />

total of 2048 users.<br />

Includes • 2048 CD Benutzer with management software.<br />

•A 64 maximum Gruppenof<br />

64 central units can be connected (2048<br />

The door controller manages the devices in each access: up<br />

•accesses). 4 Profile<br />

to two • Parking/Garagen<br />

readers (if they are used as entrance and exit), electric<br />

Includes four management softwares: CAC Data Base<br />

lock, • 32 door Areas sensor and exit button.<br />

Server, CAC Server, CAC Access and CAC Time &<br />

Up •to 32 32 schedules door controllers can be connected in series to<br />

•Attendance. Tür auf/zu<br />

manage 32 entry and exit accesses.<br />

•The Firmware Central update Unit also inmonitors installation up to 1.000 sensors and<br />

Thanks • Software to the kanninternal im Internet memory, heruntergeladen it enables user<br />

1.000 relays for automatic functions.<br />

authorizations/cancellations werden<br />

and access permits/restrictions<br />

Local (USB, RS-232) or remote (IP) connection to PC via<br />

from a PC.<br />

the corresponding module (see accessories section).<br />

On-line incidents record. Capacity: 1.000 users.<br />

Indoor installation Each Central and separate Unit manages: from the reader for greater<br />

security. 2.048 users.<br />

Admits Wiegand-26 32 input accesses. or magstrip.<br />

3.000 incidents (entries, exits, access<br />

Each door controller manages 1.000 users.<br />

denied, alerts, etc) in memory, with no need to<br />

The connection between controllers consists of 2 power<br />

download to PC.<br />

wires and a twisted pair for data.<br />

Managing up to 1.000 intercom panels, 1.000<br />

Admits an exit and entrance reader, electric lock relay,<br />

sensors and 1.000 relays.<br />

auxiliary relay for other functions, pushbutton connection,<br />

( )<br />

door sensor and free access button.<br />

The readers connectable to the Central Unit are with built-<br />

Necessary for vehicle accesses for connection of entrance<br />

Tür-Kontroller in or external controller (ref.4420).<br />

Door Controller or exit detection (ref.44201) coils.<br />

F04420 Status Tür-Kontroller<br />

LEDs: transmission and reception.<br />

Programmation<br />

Door controller Technische<br />

All with programming<br />

Daten: 500 event is done memory with CAC (ref.44201).<br />

software from one or<br />

Lets you connect any reader with Wiegand-26 output or<br />

Includes CD • bis with zu management 32 several Eintrittskontrollen<br />

duly authorized software. on line or remote computers.<br />

Magstrip (Aba TrackII or Dataclock).<br />

• bis zu 1‘000 Benutzer<br />

The door controller manages the devices in each access: up<br />

• Twisted Admits pair Dallas füri-button Datenkommunikaion<br />

key readers and matrix keypads in<br />

Installation<br />

to two readers • 2 Drähte 8-bit (if they burst für are format. Speisung used as entrance and exit), electric<br />

lock, door Programmierung:<br />

sensor One and power exit supply button. (ref.4813) recommended every 6 readers.<br />

Up to 32 •door via PC controllers can be connected in series to<br />

2 wires<br />

Programmed from a PC with the corresponding software<br />

manage 32 entry and exit accesses.<br />

(included in ref.44201).<br />

twisted pairThanks<br />

to the internal memory, it enables user<br />

Central Unit<br />

Installation authorizations/cancellations (ref.4410) Installation in mechanism and access box permits/restrictions<br />

100x100mm or surface<br />

1 2 3<br />

4 5 6 from a 1PC. 2 3<br />

4 5 6<br />

1 2 3<br />

4 5 mounted 6 with 2 screws (included).<br />

7 8 9<br />

7 8 9<br />

A 0 B<br />

7 8 9<br />

A 0 B<br />

A 0 B<br />

On-line incidents record. Capacity: 1.000 users.<br />

Indoor Up installation to 32 readers and separate from the reader for greater<br />

security.<br />

restricted area<br />

PRIVATE ACCESS CONTROL Admits 1 2 3 Wiegand-26 input or magstrip.<br />

Programmation<br />

( restricted area )<br />

power supply<br />

PRIVATE ACCESS CONTROL<br />

1 2 3<br />

4 5 6 ........ ........<br />

7 8 9<br />

Up to 32 readers<br />

PC connection accessory<br />

(needed) ref.24661<br />

2 wires 2 wires<br />

1 2 3 A<br />

A 0 B<br />

4 5 6 0<br />

7 twisted 8 9 B pair<br />

twisted pair<br />

CAC Steuergerät Central Unit (ref.4410)<br />

Door Controller (ref.44201)<br />

A 0 B<br />

Reader Each door controller manages 1.000 users.<br />

PC The connection between controllers consists of 2 power<br />

wires and a twisted pair for data.<br />

Specifications Dimensions (WxHxDmm): 175x90x40 Cons. (mA) without door release: 150<br />

Admits an exit and entrance reader, electric lock relay,<br />

Fixation: DIN rail or 2 screws to wall Operating temperature: 0 to 60ºC<br />

Specificationsauxiliary relay Dimensions for other (WxHxDmm): functions, 85x88x25 pushbutton Consumption connection, 27<br />

Power supply (V):<br />

12Vdc<br />

(mA): 15/100<br />

door sensor Power and supply free (V): access button. 12Vdc Operating temperature: 0 to 60ºC<br />

Up to 32 readers<br />

Door controllers (ref.44201)<br />

4 5 6<br />

7 8 9