PRODUCT FLASH<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
<strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong><br />
Spinnereistrasse 10, CH-9008 St. Gallen<br />
Phone +41 (0)71 243 29 29 / Fax +41 (0)71 243 29 28<br />
info@gesys.ch / www.gesys.ch<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>-<strong>SPS</strong><br />
<strong>Grossenbacher</strong> <strong>Systeme</strong> GmbH<br />
Ruhrstrasse 15, DE-63452 Hanau<br />
Phone +49 (0)6181 6751 999/ Fax +49 (0)6181 6751 998<br />
sales.de@gesys.ch
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Urheberrechtshinweis<br />
Unterlage für zukünftige Verwendung aufbewahren!<br />
Diese Unterlagen sind geistiges Eigentum der <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>, der auch das<br />
ausschliessliche Urheberrecht daran zusteht. Eine inhaltliche Änderung, die<br />
Vervielfältigung oder der Nachdruck dieser Unterlagen sowie deren Weitergabe an Dritte<br />
ist nur mit der ausdrücklichen Erlaubnis der <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> gestattet.<br />
<strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> lehnt jede Haftung für Schäden ab, die durch die<br />
Anwendung von falschen bzw. unzureichenden oder aufgrund fehlender Informationen in<br />
diesen Unterlagen entstehen.<br />
<strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> behält sich das Recht vor, dieses Dokument teilweise oder<br />
vollständig zu ändern.<br />
Alle Marken- und Produktnamen sind Warenzeichen oder<br />
eingetragene Warenzeichen der jeweiligen Titelhalter.<br />
DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
Bestimmungsgemässer Gebrauch<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Hardware, <strong>Soft</strong>ware, Betriebssysteme und Treiber dürfen nur für die beschriebenen Einsatzfälle<br />
und nur in Verbindung mit den von <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> empfohlenen Komponenten<br />
verwendet werden.<br />
Warnung<br />
Defekte, die durch unsachgemässe Behandlung des Gerätes entstehen, sind von der Garantie<br />
ausgeschlossen.<br />
Über dieses Gerät dürfen keine sicherheitsrelevanten Funktionen im Sinne von Personen- und<br />
Maschinenschutz, realisiert werden.<br />
Für Folgeschäden, die durch einen Ausfall oder eine Funktionsstörung entstehen, wird jede<br />
Haftung abgelehnt.<br />
Alle in diesem Dokument angegebenen Daten sind keine zugesicherten Eigenschaften im<br />
rechtlichen Sinn.<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 1
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Sicherheitstechnische Hinweise für den Benutzer<br />
Diese Systembeschreibung enthält die erforderlichen Informationen für den<br />
bestimmungsgemässen Gebrauch der darin beschriebenen Produkte. Es wendet sich an<br />
technisch qualifiziertes Personal.<br />
Qualifiziertes Personal im Sinne der sicherheitsbezogenen Hinweise in dieser<br />
Systembeschreibung oder auf dem Produkt selbst sind Personen, die:<br />
- entweder als Projektierungspersonal mit den Sicherheitskonzepten der<br />
Automatisierungstechnik vertraut sind,<br />
- oder als Bedienpersonal im Umgang mit Einrichtungen der Automatisierungstechnik<br />
unterwiesen sind und den auf die Bedienung bezogenen Inhalt dieser Systembeschreibung<br />
kennen,<br />
- oder als Inbetriebsetzungs- und Servicepersonal eine zur Reparatur derartiger Einrichtungen<br />
der Automatisierungstechnik befähigende Ausbildung besitzen, sowie die Berechtigung<br />
haben, Stromkreise und Geräte/<strong>Systeme</strong> gemäss den Standards der Sicherheitstechnik in<br />
Betrieb zu nehmen.<br />
2 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
Inhaltsverzeichnis<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
1 SYMBOLERKLÄRUNG .................................................................................................................................................. 4<br />
2 EINLEITUNG .................................................................................................................................................................... 5<br />
3 INSTALL<strong>AT</strong>ION .............................................................................................................................................................. 7<br />
3.1 RUNTIME-SYSTEM................................................................................................................... 7<br />
3.2 RUNTIME-SYSTEM UPD<strong>AT</strong>E ........................................................................................................ 7<br />
4 <strong>AT</strong>-<strong>S7</strong> SOFT-<strong>SPS</strong>............................................................................................................................................................. 9<br />
4.1 LEISTUNGSMERKMALE/MENGENGERÜST ........................................................................................ 9<br />
4.2 STARTVERHALTEN/ANLAUF....................................................................................................... 9<br />
4.3 REMANENTE D<strong>AT</strong>EN .............................................................................................................. 10<br />
4.4 SIM<strong>AT</strong>IC MAN<strong>AG</strong>ER............................................................................................................. 10<br />
4.4.1 Hardware Konfiguration............................................................................................ 10<br />
4.4.2 Online Funktionen ..................................................................................................... 12<br />
4.5 <strong>S7</strong>-400 (CPU 416) UND <strong>AT</strong>-<strong>S7</strong> SOFT-<strong>SPS</strong> .............................................................................. 12<br />
4.5.1 Organisationsbausteine ............................................................................................ 12<br />
4.5.2 Systemfunktionen ..................................................................................................... 13<br />
4.5.3 Systemfunktionsbausteine......................................................................................... 15<br />
4.5.4 Systemdatenbausteine .............................................................................................. 16<br />
4.5.5 <strong>S7</strong> Standard Library (stdlib30) .................................................................................. 17<br />
4.6 KONFIGUR<strong>AT</strong>ION DER <strong>AT</strong>-<strong>S7</strong> SOFT-<strong>SPS</strong> ..................................................................................... 20<br />
4.6.1 SYSPARAM-DB ........................................................................................................... 20<br />
4.6.2 SYSPARAM Beispiel .................................................................................................... 23<br />
4.7 CAN-MASTER, COMPACT-I/O-MODUL CAN .............................................................................. 24<br />
4.7.1 Fehlerhandling.......................................................................................................... 24<br />
4.8 KONFIGUR<strong>AT</strong>ION PROFIBUS DP-MASTER ..................................................................................... 26<br />
4.9 KOMMUNIK<strong>AT</strong>ION ................................................................................................................. 30<br />
4.9.1 Allgemein.................................................................................................................. 30<br />
4.9.2 Kommunikation zur Visualisierung EPAM................................................................... 30<br />
4.9.3 Kommunikationsbausteine ........................................................................................ 30<br />
4.9.4 Datenkopplung Ethernet TCP/IP ................................................................................ 35<br />
5 PROGRAMMIERUNG DER STEUERUNG.............................................................................................................38<br />
5.1 VERBINDUNG DES PROGRAMMIER-PC MIT DER STEUERUNG............................................................... 38<br />
5.2 EINSTELLUNG DES PROGRAMMIER-PC FÜR DIE ETHERNET-KOMMUNIK<strong>AT</strong>ION .......................................... 38<br />
5.3 EINSTELLUNG DER ETHERNET KOMMUNIK<strong>AT</strong>ION IM SIM<strong>AT</strong>IC-MAN<strong>AG</strong>ER.............................................. 38<br />
5.4 EINSTELLUNG DER IP-ADRESSE AUF DEM ZIELSYSTEM...................................................................... 39<br />
5.5 PROJEKT-DOWNLOAD ............................................................................................................ 39<br />
6 VERSIONSGESCHICHTE ...........................................................................................................................................40<br />
7 STICHWORTVERZEICHNIS......................................................................................................................................43<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 3
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
1 Symbolerklärung<br />
Gefahrenhinweise<br />
Die folgenden Hinweise dienen Ihrer persönlichen Sicherheit und dem Schutz vor Beschädigung des<br />
beschriebenen Produkts oder angeschlossener Geräte.<br />
Sicherheitshinweise und Warnungen zur Abwendung von Gefahren für Leben und Gesundheit von<br />
Benutzern oder Instandhaltungspersonal, sowie zur Vermeidung von Sachschäden werden in dieser<br />
Anleitung durch die hier definierten Piktogramme hervorgehoben. Grundsätzlich wird in diesem<br />
Dokument unterschieden zwischen Piktogramme als „Warnung“ und Piktogramme als "Hinweis“.<br />
Warnungen haben allgemein folgende Bedeutung:<br />
Tod, schwere Körperverletzung oder erhebliche Sachschäden können eintreten, wenn die<br />
entsprechenden Vorsichtsmassnahmen nicht getroffen werden.<br />
Die einzelnen Piktogramme als „Warnung“ haben folgende Bedeutung:<br />
Achtung ! Allgemein !<br />
Ist ein Hinweis, der beachtet werden muss, um sich rechtzeitig vor Gefahren<br />
während und um den Betrieb des Gerätes zu schützen. Das richtige Vorgehen ist zu<br />
beachten.<br />
Achtung ! Stromschlag !<br />
In elektrischen Anlagen können für Menschen gefährliche Spannungen auftreten. Bei<br />
Berührung von spannungsführenden Teilen besteht die Gefahr eines elektrischen<br />
Stromschlags.<br />
Achtung ! ESD-Schutzmassnahmen beachten !<br />
Elektrostatische Entladungen können elektronische Bauteile zerstören.<br />
Hinweise haben allgemein folgende Bedeutung:<br />
Wichtige Information über das Produkt oder den jeweiligen Teil der Anleitung, auf die besonders<br />
aufmerksam gemacht werden soll.<br />
Das verwendete Piktogramm als „Hinweis“ hat folgende Bedeutung:<br />
Beschreibung der wichtigen, hinweisenden Information.<br />
4 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
2 Einleitung<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Dieses Dokumentation beschreibt die Handhabung der <strong>AT</strong>-<strong>S7</strong> und beinhaltet hauptsächlich<br />
Anpassungen und Sonderheiten für die <strong>Grossenbacher</strong>-Panels.<br />
Übersicht der wichtigsten Dokumente:<br />
Thema Dokumentation Nummer<br />
WindowsCE Systembeschreibung WindowsCE 48650<br />
EPAM EPAM Handbuch 38480<br />
SyCon Hilscher Systemkonfigurator<br />
(Profibus)<br />
Onlinehelp bzw. www.hilscher.com<br />
EthernetPanel Gerätebeschreibung 48960<br />
Compact-Panel-<br />
PC/Compact-PC<br />
Gerätebeschreibung 38465<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 5
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
6 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
3 Installation<br />
Für die Programmierung der <strong>AT</strong>-<strong>S7</strong> - <strong>Soft</strong>-<strong>SPS</strong> wird der SIM<strong>AT</strong>IC Manager benötigt:<br />
• Es werden die Programmierpakete STEP7 ® ab v5.3 unterstützt.<br />
• Die Programmierung erfolgt über die PG/PC-Schnittstelle via Ethernet TCP/IP<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Die <strong>Grossenbacher</strong> Panels sind mit der STEP®7 Version 5.3 getestet.<br />
Bei Verwendung anderer STEP®7-Versionen kann keine Funktionsgarantie<br />
übernommen werden!<br />
Für die Konfiguration des ProfibusDP-Master wird der Hilscher System Konfigurator SyCon ab V2.701<br />
benötigt. (s.a. www.hischer.com)<br />
3.1 RUNTIME-SYSTEM<br />
Das Runtime-System besteht aus folgenden Dateien auf dem CompactFlash im Verzeichnis<br />
\StorageCard\<strong>AT</strong>-<strong>S7</strong>:<br />
CPU416.exe …<strong>Soft</strong>-<strong>SPS</strong> Runtime-System<br />
Shutdown.exe …Utility zum Beenden der <strong>AT</strong>-<strong>S7</strong><br />
CPU416.lnk …Desktop-Link zu \<strong>AT</strong>-<strong>S7</strong>\CPU416.exe<br />
xxcpu1.dll ...CAN-Treiber DLL<br />
GRBSJA1000.reg …CAN-Konfiguration<br />
Der Ordner \StorageCard\<strong>AT</strong>-<strong>S7</strong> beinhaltet auch das <strong>SPS</strong>-Bootprojekt, bestehend aus folgenden<br />
Dateien:<br />
Image@st.prj<br />
Image@st.s7d<br />
Die <strong>Soft</strong>-<strong>SPS</strong> wird über die Autoexec.cmd bzw. PLC.B<strong>AT</strong> beim Einschalten des Panels automatisch<br />
gestartet. (s.a. Systembeschreibung WindowsCE) Hierbei werden alle benötigten Dateien ins<br />
Verzeichnis \<strong>AT</strong>-<strong>S7</strong> im RAM kopiert, somit kann auch im Betrieb ein Update des Runtime-Systems<br />
erfolgen (s.a. Runtime-System Update)<br />
3.2 RUNTIME-SYSTEM UPD<strong>AT</strong>E<br />
Neben dem Anwenderprogramm und dem EPAM-Projekt befindet sich auch das komplette Runtime-<br />
System der Steuerungen inkl. Betriebsystem WindowsCE auf der CompactFlash-Speicherkarte.<br />
Der Runtime-System Update kann mit Hilfe des Programms SetupTargetFirmwareWinCEx86-Vxxx.exe<br />
via CompactFlash-Adapter und PC oder via FTP erfolgen (s.a. Systembeschreibung WindowsCE)<br />
Mit SetupTargetFirmware wird das Betriebsystem WindowsCE inkl. Tools, das <strong>SPS</strong>- und das EPAM-<br />
Runtime System installiert.<br />
1 Ab CPU416 V1.6.0019<br />
Remanente <strong>SPS</strong>-Daten (Retaindaten) werden mit dem Befehl „RAM nach ROM<br />
kopieren“ mit dem <strong>SPS</strong>-Projekt auf der CF-Karte gespeichert! 1<br />
Vor einem Runtime-System-Update sollte ein „Urlöschen“ durchgeführt und<br />
anschliessend das Projekt neu übertragen werden.<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 7
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
8 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
4 <strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>-<strong>SPS</strong><br />
4.1 LEISTUNGSMERKMALE/MENGENGERÜST<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Leistungsmerkmale/Mengengeräst<br />
<strong>SPS</strong>-Funktionalität<br />
Mengengerüst<br />
CPU416 kompatibel:<br />
CPU416-2 DP<br />
CP443-1 TCP<br />
<strong>SPS</strong>-Programm gesamt 1MB Programm<br />
Bootprojekt auf CompactFlash (StorageCard\<strong>AT</strong>-<strong>S7</strong>)<br />
<strong>SPS</strong>-Daten gesamt 1MB Daten<br />
Remanente Daten 32kByte<br />
Prozessabbild Eingänge<br />
Prozessabbild Ausgänge<br />
Merker<br />
Zeiten<br />
Zähler<br />
Lokaldaten<br />
OB<br />
FC<br />
FB<br />
DB<br />
SFB<br />
SFC<br />
2 , netzausfallsicher (z.B. 32 DBs a 1kByte)<br />
131072 Bit (16kByte) E0.0 bis E16383.7<br />
131072 Bit (16kByte) A0.0 bis A16383.7<br />
131072 Bit (16kByte) M0.0 bis M16383.7<br />
2048 T0 bis T2047<br />
2048 Z0 bis Z2047<br />
16384 Byte<br />
128 (max. Länge 65570 Byte)<br />
2048 (max. Länge 65570 Byte)<br />
2048 (max. Länge 65570 Byte)<br />
4099 (max. Länge 65570 Byte)<br />
18<br />
50<br />
I/O-Ankopplung<br />
<strong>SPS</strong>-Programmierung<br />
integrierter CAN-Controller (nur für Compact I/O-Modul CAN)<br />
PROFIBUS-DP Master (Hilscher EC1)<br />
Hilscher-PC104 Modul (CIF)<br />
Schnittstelle<br />
Ethernet TCP/IP<br />
Programmiersystem STEP®7 SIM<strong>AT</strong>IC Manager ab V5.3 (empfohlen V5.3)<br />
Performance Bytebefehle: Merker 0,32us / Befehle (EP-300)<br />
Bytebefehle Retaindaten (z.B. DB100-131) 2us / Befehl (EP-300)<br />
4.2 STARTVERHALTEN/ANLAUF<br />
Die <strong>Soft</strong>-<strong>SPS</strong> (StorageCard\<strong>AT</strong>-<strong>S7</strong>\CPU416.exe) wird beim Einschalten des Gerätes automatisch<br />
gestartet (s.a. Autoexec.cmd bzw. PLC.B<strong>AT</strong>). Folgende Optionen sind beim Aufruf von CPU416.exe<br />
möglich (s.a. StorageCard\<strong>AT</strong>-<strong>S7</strong>\PLC.B<strong>AT</strong>):<br />
/RAM:xxxxx ...Adresse des remanenten Speicherbereichs. Default: /RAM:D4000 (s.a.<br />
Gerätebeschreibung)<br />
Die <strong>AT</strong>-<strong>S7</strong> kann über das Utility „Shutdown“ beendet und über den Desktop-Link „CPU416“ wieder<br />
gestartet werden.<br />
Nach dem Einschalten der Spannung wird das Anwenderprogramm (Bootprojekt) aus dem<br />
CompactFlash (StorageCard\<strong>AT</strong>-<strong>S7</strong>) ins RAM geladen und die <strong>SPS</strong> gestartet. (Default: Neustart)<br />
Das Startverhalten (Neustart/Kaltstart) kann über der SYSPARAM DB (DBx->SDP->PO) konfiguriert<br />
werden.<br />
Das Anwenderprogramm kann mit dem SIM<strong>AT</strong>IC-Manager Befehl „RAM nach ROM kopieren“ auf das<br />
CompactFlash kopiert werden.<br />
Mit „Urlöschen“ wird das Anwenderprogramm auf der CompactFlash gelöscht.<br />
2 s.a. Gerätebeschreibung<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 9
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
4.3 REMANENTE D<strong>AT</strong>EN<br />
Im Unterschied zu einer Siemens CPU416 sind bei der <strong>AT</strong>-<strong>S7</strong> nicht alle Daten remanent, sondern nur<br />
die Datenbausteine DB100 bis DB131 mit je ein kByte (Defaulteinstellung).<br />
Diese DBs werden in den 32kB grossen remanenten Speicherbereich angelegt. (Grösse des<br />
remanenten Datenspeicher s.a. Gerätebeschreibung).<br />
Es können auch grössere DBs definiert werden z.B. 2kB, wobei in diesem Fall der DB101 nicht<br />
verwendet werden darf, usw.<br />
Der erste remanente DB kann über den Eintrag „RI“ in der SYSPARAM-DB Erweiterung (DBx->SDP->RI)<br />
definiert werden. (Default: RI 100)<br />
Initialisierung der remanenten Daten:<br />
- Erfolgt durch Laden des Projekts via Step7 Manager auf das Gerät<br />
- Durch den Befehl Urlöschen<br />
- Wenn die gerätespezifische Kennung in dem remanenten Speicherbereich nicht mit dem<br />
Projekt übereinstimmt (z.B. beim Wechsel der CF-Karte von einem Gerät in ein anderes oder<br />
bei Datenverlust)<br />
Die remanenten Daten sind mit einer gerätespezifischen Kennung versehen,<br />
hierfür werden die letzten 64 Bytes des remanenten Speicherbereichs<br />
verwendet. Die Grösse des verfügbaren remanenten Speichers reduziert sich<br />
daher um 64 Byte!<br />
Die remanenten DBs werden hierbei mit den Werten zum Zeitpunkt „RAM nach ROM kopieren“<br />
initialisiert. 3<br />
4.4 SIM<strong>AT</strong>IC MAN<strong>AG</strong>ER<br />
4.4.1 Hardware Konfiguration<br />
Die Hardware-Konfiguration der <strong>AT</strong>-<strong>S7</strong> auf den <strong>Grossenbacher</strong>-Panels sieht wie folgt aus:<br />
3 ab CPU416 V1.6.0019<br />
10 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 11
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
4.4.2 Online Funktionen<br />
Online Funktionen:<br />
Status Funktion<br />
Integriert Bausteinverwaltung<br />
Integriert Erreichbare Teilnehmer<br />
Integriert RAM nach ROM kopieren<br />
--- Anwenderprogramm laden auf Memory Card<br />
--- Projekt auf Memory Card speichern<br />
--- Projekt aus Memory Card holen<br />
Integriert Forcewerte anzeigen<br />
Integriert Variable beobachten/steuern<br />
--- Hardware diagnostizieren<br />
Integriert Baugruppenzustand<br />
Integriert Betriebszustand<br />
Integriert Urlöschen<br />
Integriert Uhrzeit stellen<br />
Integriert Baustein beobachten<br />
Integriert Haltepunkteleiste<br />
teilweise Interpretation von Systemdatenbausteinen (SDBs) siehe Kap.<br />
Systemdatenbausteine<br />
CFC<br />
Online Funktionen: Basis STEP 7<br />
Status Funktion<br />
Integriert Online allgemein<br />
WinCC<br />
Online Funktionen:<br />
Status Funktion<br />
Integriert Online allgemein<br />
4.5 <strong>S7</strong>-400 (CPU 416) UND <strong>AT</strong>-<strong>S7</strong> SOFT-<strong>SPS</strong><br />
4.5.1 Organisationsbausteine<br />
<strong>S7</strong>-400 <strong>AT</strong>-<strong>S7</strong><br />
Organisationsbausteine Beschreibung CPU 416 <strong>Soft</strong>-<strong>SPS</strong><br />
OB 1 Zyklische Programmbearbeitung X X<br />
OB 10..17 Uhrzeitalarme X<br />
OB 20..23 Verzögerungsalarme X<br />
OB 30..38 Weckalarme X X<br />
OB 40..47 Prozessalarme X<br />
OB 60 Multicomputingalarm X<br />
OB 80..87 Asynchrone Fehleralarme X X (OB80)<br />
OB 90 Hintergrund X X<br />
OB 100 Neustart X X<br />
OB 101 Wiederanlauf X<br />
OB 102 Kaltstart X X<br />
OB 121,122 Synchrone Fehleralarme X X<br />
12 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
4.5.2 Systemfunktionen<br />
<strong>S7</strong>-400 <strong>AT</strong>-<strong>S7</strong><br />
Systemfunktionen Beschreibung CPU 416 <strong>Soft</strong>-<strong>SPS</strong><br />
SFC 0 SET_CLK X X<br />
SFC 1 READ_CLK X X<br />
SFC 2 SET_RTM X X 3)<br />
SFC 3 CTRL_RTM X X 3)<br />
SFC 4 READ_RTM X X 3)<br />
SFC 5 GADR_LGC X X 1)<br />
SFC 6 RD_SINFO X X<br />
SFC 7 DP_PRAL X<br />
SFC 9 EN_MSG X<br />
SFC 10 DIS_MSG X<br />
SFC 11 SYC_FR X<br />
SFC 12 D_ACT_DP X X 1)<br />
SFC 13 DP_NRMDG X<br />
SFC 14 DPRD_D<strong>AT</strong> X X<br />
SFC 15 DPWR_D<strong>AT</strong> X X<br />
SFC 17 ALARM_SQ X X 1)<br />
SFC 18 ALARM_S X X 1)<br />
SFC 19 ALARM_SC X<br />
SFC 20 BLKMOV X X<br />
SFC 21 FILL X X<br />
SFC 22 CRE<strong>AT</strong>_DB X X<br />
SFC 23 DEL_DB X X<br />
SFC 24 TEST_DB X X<br />
SFC 25 COMPRESS X X<br />
SFC 26 UPD<strong>AT</strong>_PI X X<br />
SFC 27 UPD<strong>AT</strong>_PO X X<br />
SFC 28 SET_TINT X<br />
SFC 29 CAN_TINT X<br />
SFC 30 ACT_TINT X<br />
SFC 31 QRY_DINT X<br />
SFC 32 SRT_DINT X<br />
SFC 33 CAN_DINT X<br />
SFC 34 QRY_DINT X<br />
SFC 35 MP_ALARM X<br />
SFC 36 MSK_FLT X X<br />
SFC 37 DMSK_FLT X X<br />
SFC 38 READ_ERR X<br />
SFC 39 DIS_IRT X X<br />
SFC 40 EN_IRT X X<br />
SFC 41 DIS_AIRT X X<br />
SFC 42 EN_AIRT X X<br />
SFC 43 RE_TRIGR X X<br />
SFC 44 REPL_VAL X<br />
SFC 46 STP X X<br />
SFC 47 WAIT X X<br />
SFC 48 SNC_RTCB X<br />
SFC 49 LGC_GADR X<br />
SFC 50 RD_LGADR X<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 13
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
SFC 51 RDSYSST X X 2)<br />
SFC 52 WR-USMSG X X 1)<br />
SFC 54 RD_DPARAM X<br />
SFC 55 WR-PARM X<br />
SFC 56 WR_DPARM X<br />
SFC 57 PARM_MOD X<br />
SFC 58 WR_REC X X 1)<br />
SFC 59 RD_REC X X 1)<br />
SFC 60 GD_SND X<br />
SFC 61 GD_RCV X<br />
SFC 62 CONTROL X<br />
SFC 64 TIME_TCK X X<br />
SFC 65 X_SEND X<br />
SFC 66 X_RCV X<br />
SFC 67 X_GET X<br />
SFC 68 X_PUT X<br />
SFC 69 X_ABORT X<br />
SFC 72 I_GET X X<br />
SFC 73 I_PUT X X<br />
SFC 74 I_ABORT X X<br />
SFC 79 SET X X<br />
SFC 80 RSET X X<br />
SFC 81 UBLKMOV X X<br />
SFC 200 KG2REAL X<br />
SFC 201 REAL2KG X<br />
SFC 202 BLKSWAP X<br />
SFC 244 SR X<br />
SFC 246 RW X<br />
SFC 247 CONTROL X<br />
SFC 248 RESET X<br />
SFC 249 SYNCHRON X<br />
SFC 252 XCODE X<br />
1) In CPU enthalten, jedoch nicht bzw nicht vollständig implementiert. Die Bausteine liefern in der Regel ein negatives<br />
Resultat.<br />
2) Mit SZL 17, 20, 21, 36<br />
3) verfügbar ab V1.6.0006<br />
14 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
4.5.3 Systemfunktionsbausteine<br />
<strong>S7</strong>-400 <strong>AT</strong>-<strong>S7</strong><br />
Systemfunktionsbausteine Beschreibung CPU 416 <strong>Soft</strong>-<strong>SPS</strong><br />
SFB 0 CTU X X<br />
SFB 1 CTD X X<br />
SFB 2 CTUD X X<br />
SFB 3 TP X X<br />
SFB 4 TON X X<br />
SFB 5 TOF X X<br />
SFB 8 USEND X X<br />
SFB 9 URCV X X<br />
SFB 12 BSEND X X<br />
SFB 13 BRCV X X<br />
SFB 14 GET X X<br />
SFB 15 PUT X X<br />
SFB 16 PRINT X X 1)<br />
SFB 19 START X X 1)<br />
SFB 20 STOP X X 1)<br />
SFB 21 RESUME X X 1)<br />
SFB 22 ST<strong>AT</strong>US X X 1)<br />
SFB 23 UST<strong>AT</strong>US X<br />
SFB 29 HS_COUNT X<br />
SFB 30 FREQ_MES X<br />
SFB 31 NOTIFY8P X<br />
SFB 32 DRUM X<br />
SFB 33 ALARM X X 1)<br />
SFB 34 ALARM_8 X<br />
SFB 35 ALARM_8P X<br />
SFB 36 NOTIFY X<br />
SFB 37 AR_SEND X<br />
SFB 38 HSC_A_B X<br />
SFB 39 POS X<br />
SFB 41 CONT_R X<br />
SFB 42 CONT_S X<br />
SFB 43 PULSEGEN X<br />
SFB 52 RDREC X<br />
SFB 53 WRREC X<br />
SFB 54 RALRM X<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
1) In CPU enthalten, jedoch nicht bzw nicht vollständig implementiert. Die Bausteine liefern in der Regel ein negatives<br />
Resultat<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 15
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
4.5.4 Systemdatenbausteine<br />
<strong>S7</strong>-400 <strong>AT</strong>-<strong>S7</strong><br />
Systemdatenbausteine Beschreibung CPU 416 <strong>Soft</strong>-<strong>SPS</strong><br />
SDB <br />
Die Reihenfolge der Initialisierung:<br />
1. Default-Parameter<br />
2. SYSPARAM-Parameter<br />
3. SDB0-Parameter<br />
Mindestzykluszeit<br />
Folgende Einstellungen werden<br />
aus der HW Konfig übernommen:<br />
- OB1-Prozessabbild<br />
zyklisch aktualisieren<br />
- Weckalarme<br />
- Zyklusüberwachungszeit<br />
- Mindestzykluszeit<br />
- Taktmerker<br />
X X<br />
Die Mindestzykluszeit darf NICHT auf 0 gesetzt werden, da sonst die <strong>AT</strong>-<strong>S7</strong> die<br />
zuviel CPU-Zeit in Anspruch nimmt und somit für andere, niederpriore<br />
Aufgaben wie z.B. die Visualisierung zuwenig CPU-Zeit übrig bleibt!<br />
Die CPU hat eine fixe Mindestzeit von 1ms, die nicht unterschritten werden kann.<br />
Die Mindestzykluszeit sollte als Richtwert so gewählt werden, dass die CPU-Last<br />
nicht über 70-80% steigt. D.h. z.B. bei einem durchschnittlichen <strong>SPS</strong>-Zyklus von<br />
10ms sollte die Mindestzykluszeit 10ms/0,7 = 15ms sein.<br />
Hardware-Eigenschaften-Remanenz<br />
Wenn Anzahl Merker, Timer und Zähler ungleich 0 gesetzt werden, dann werden die<br />
Daten aus dem Bootprojekt übernommen, d.h. der Wert entspricht dann dem<br />
aktuellen Wert zum Zeitpunkt „RAM nach ROM kopieren“.<br />
16 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
4.5.5 <strong>S7</strong> Standard Library (stdlib30)<br />
S5-<strong>S7</strong> Converting Blocks<br />
<strong>S7</strong>-400 <strong>AT</strong>-<strong>S7</strong><br />
Systemfunktionen Beschreibung CPU 416 <strong>Soft</strong>-<strong>SPS</strong><br />
Familie Name<br />
FC 61 S5_CNVRT GP_FPGP X X<br />
FC 62 S5_CNVRT GP_GPFP X X<br />
FC 63 S5_CNVRT GP_ADD X X<br />
FC 64 S5_CNVRT GP_SUB X X<br />
FC 65 S5_CNVRT GP_MUL X X<br />
FC 66 S5_CNVRT GP_DIV X X<br />
FC 67 S5_CNVRT GP_VGL X X<br />
FC 68 S5_CNVRT RAD_GP X X<br />
FC 69 S5_CNVRT MLD_TG X X<br />
FC 70 S5_CNVRT MELD_TGZ X X<br />
FC 71 S5_CNVRT MLD_EZW X X<br />
FC 72 S5_CNVRT MLD_EDW X X<br />
FC 73 S5_CNVRT MLD_SAMW X X<br />
FC 74 S5_CNVRT MLD_SAM X X<br />
FC 75 S5_CNVRT MLD_EZ X X<br />
FC 76 S5_CNVRT MLD_ED X X<br />
FC 77 S5_CNVRT MLD_EZWK X X<br />
FC 78 S5_CNVRT MLD_EDWK X X<br />
FC 79 S5_CNVRT MLD_EZK X X<br />
FC 80 S5_CNVRT MLD_EDK X X<br />
FC 81 S5_CNVRT COD_B4 X X<br />
FC 82 S5_CNVRT COD_16 X X<br />
FC 83 S5_CNVRT MUL_16 X X<br />
FC 84 S5_CNVRT DIV_16 X X<br />
FC 85 S5_CNVRT ADD_32 X X<br />
FC 86 S5_CNVRT SUB_32 X X<br />
FC 87 S5_CNVRT MUL_32 X X<br />
FC 88 S5_CNVRT DIV_32 X X<br />
FC 89 S5_CNVRT RAD_16 X X<br />
FC 90 S5_CNVRT REG_SCHB X X<br />
FC 91 S5_CNVRT REG_SCHW X X<br />
FC 92 S5_CNVRT REG_FIFO X X<br />
FC 93 S5_CNVRT REG_LIFO X X<br />
FC 94 S5_CNVRT DB_COPY1 X X<br />
FC 95 S5_CNVRT DB_COPY2 X X<br />
FC 96 S5_CNVRT RETTEN X X<br />
FC 97 S5_CNVRT LADEN X X<br />
FC 98 S5_CNVRT COD_B8 X X<br />
FC 99 S5_CNVRT COD_32 X X<br />
FC 100 S5_CNVRT AE_460_1 X X<br />
FC 101 S5_CNVRT AE_460_2 X X<br />
FC 102 S5_CNVRT AE_463_1 X X<br />
FC 103 S5_CNVRT AE_463_2 X X<br />
FC 104 S5_CNVRT AE_464_1 X X<br />
FC 105 S5_CNVRT AE_464_2 X X<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 17
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
FC 106 S5_CNVRT AE_466_1 X X<br />
FC 107 S5_CNVRT AE_466_2 X X<br />
FC 108 S5_CNVRT RLG_AA1 X X<br />
FC 109 S5_CNVRT RLG_AA2 X X<br />
FC 110 S5_CNVRT PER_ET1 X X<br />
FC 111 S5_CNVRT PER_ET2 X X<br />
FC 112 S5_CNVRT SINUS X X<br />
FC 113 S5_CNVRT COSINUS X X<br />
FC 114 S5_CNVRT TANGENS X X<br />
FC 115 S5_CNVRT COTANG X X<br />
FC 116 S5_CNVRT ARCSIN X X<br />
FC 117 S5_CNVRT ARCCOS X X<br />
FC 118 S5_CNVRT ARCTAN X X<br />
FC 119 S5_CNVRT ARCCOT X X<br />
FC 120 S5_CNVRT LN_X X X<br />
FC 121 S5_CNVRT LG_X X X<br />
FC 122 S5_CNVRT B_LOG_X X X<br />
FC 123 S5_CNVRT E_H_N X X<br />
FC 124 S5_CNVRT ZEHN_H_N X X<br />
FC 125 S5_CNVRT A2_H_A1 X X<br />
18 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
IEC Function Blocks<br />
<strong>S7</strong>-400 <strong>AT</strong>-<strong>S7</strong><br />
Systemfunktionen Beschreibung CPU 416 <strong>Soft</strong>-<strong>SPS</strong><br />
Familie Name<br />
FC 1 IEC AD_DT_TM X X<br />
FC 2 IEC CONC<strong>AT</strong> X X<br />
FC 3 IEC D_TOD_DT X X<br />
FC 4 IEC DELETE X X<br />
FC 5 IEC DI_STRNG X X<br />
FC 6 IEC DT_D<strong>AT</strong>E X X<br />
FC 7 IEC DT_DAY X X<br />
FC 8 IEC DT_TOD X X<br />
FC 9 IEC EQ_DT X X<br />
FC 10 IEC EQ_STRNG X X<br />
FC 11 IEC FIND X X<br />
FC 12 IEC GE_DT X X<br />
FC 13 IEC GE_STRNG X X<br />
FC 14 IEC GT_DT X X<br />
FC 15 IEC GT_STRNG X X<br />
FC 16 IEC I_STRNG X X<br />
FC 17 IEC INSERT X X<br />
FC 18 IEC I LE_DT X X<br />
FC 19 IEC LE_STRNG X X<br />
FC 20 IEC LEFT X X<br />
FC 21 IEC LEN X X<br />
FC 22 IEC LIMIT X X<br />
FC 23 IEC LT_DT X X<br />
FC 24 IEC LT_STRNG X X<br />
FC 25 IEC MAX X X<br />
FC 26 IEC MID X X<br />
FC 27 IEC MIN X X<br />
FC 28 IEC NE_DT X X<br />
FC 29 IEC NE_STRNG X X<br />
FC 30 IEC R_STRNG X X<br />
FC 31 IEC REPLACE X X<br />
FC 32 IEC RIGHT X X<br />
FC 33 IEC S5TI_TIM X X<br />
FC 34 IEC SB_DT_DT X X<br />
FC 35 IEC SB_DT_TM X X<br />
FC 36 IEC SEL X X<br />
FC 37 IEC STRNG_DI X X<br />
FC 38 IEC STRNG_I X X<br />
FC 39 IEC STRNG_R X X<br />
FC 40 IEC TIM_S5TI X X<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 19
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
4.6 KONFIGUR<strong>AT</strong>ION DER <strong>AT</strong>-<strong>S7</strong> SOFT-<strong>SPS</strong><br />
Die Konfiguration der <strong>AT</strong>-<strong>S7</strong> erfolgt über Systemdatenbausteine (s.a. Kap. Systemdatenbausteine)<br />
und den SYSPARAM-DB.<br />
4.6.1 SYSPARAM-DB<br />
Der SYSPARAM-DB beinhaltet erweiterte Einstellungen der <strong>AT</strong>-<strong>S7</strong>. Die Objekteigenschaften der <strong>AT</strong>-<strong>S7</strong><br />
CPU-<strong>Soft</strong>ware werden in einem gemeinsamen Datenbaustein zusammengefasst.<br />
Der Datenbaustein besitzt einen strukturierten Aufbau und wird durch die Kennung ‘SYSPARAM’<br />
identifiziert.<br />
Der SYSPARAM-DB kann eine beliebige Datenbausteinnummer besitzen. Nach einem<br />
Neustart/Kaltstart werden alle Datenbausteine nach der Kennung durchsucht. Die Suche erfolgt<br />
sequentiell von 1 bin N. Der erste Datenbaustein mit der SYSPARAM – Kennung parametriert die CPU.<br />
System Dependent Parameter (SDP)<br />
Mit den Systemparametern werden die <strong>AT</strong>-<strong>S7</strong> internen Module definiert und parametriert.<br />
SDP : STRUCT<br />
T<strong>AG</strong>: STRING [4 ] := 'SDP:';<br />
PO: STRING [8 ] := 'PO N';<br />
RI: STRING [10 ] := 'RI 100';<br />
END: STRING [1 ] := ';';<br />
END_STRUCT ;<br />
System Dependent Parameter (SDP)<br />
PO Power ON Anlaufverhalten Kaltstart / Neustart(Warmstart)<br />
RI Start-DB der remanenten Daten (Default: RI 100 � DB 100)<br />
Bei Änderungen im SYSPARAM-DB ist folgende Reihenfolge einzuhalten:<br />
1. Urlöschen<br />
2. Systemdaten und SYSPARAM-DB laden<br />
3. SYSPARAM-DB initialisieren (DB-Ansicht, Bearbeiten-Datenbaustein initialisieren)<br />
4. Stop und Neustart/Kaltstart ausführen<br />
5. restliches Programm laden<br />
Der SYSPARAM-DB darf NICHT im Bereich DB100 bis 131 und NICHT im Bereich<br />
der remanenten DBs liegen. (wenn RI 100)<br />
Die Einstellungen des SYSPARAM-DB können wie folgt kontrolliert werden:<br />
- DB Ansicht öffen<br />
- Ansicht Datenansicht wählen<br />
- Stimmen die Werte Anfangswert und Aktualwert nicht überein, so muss „Bearbeiten-<br />
Datenbaustein initialisieren“ durchgeführt werden<br />
20 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Projekt Information Parameter (PIP)<br />
Die Projekt Information Parameter (PIP) können optional zur Information angegeben werden. Beim<br />
Start der CPU416 werden die Informationen auf dem Target in der Kommandozeile angezeigt.<br />
PIP STRUCT Project Information Parameter<br />
T<strong>AG</strong> STRING[4] 'PIP:'<br />
N STRING[80] 'N Projectname' Projektname<br />
V STRING[10] 'V V1.0' Projektversion<br />
P STRING[40] 'P Programmer' Programmierer<br />
T STRING[40] 'T Targetname' HW-Bezeichnung<br />
END STRING[1] ';'<br />
END_STRUCT<br />
Projekt Information Parameter (PIP)<br />
Fieldbus Controller CAN<br />
Die <strong>AT</strong>-<strong>S7</strong> CPU-<strong>Soft</strong>ware unterstützt einen CAN-Treiber für die <strong>Grossenbacher</strong> Compact-I/O-Module<br />
CAN (z.B. Art.Nr. 5081344).<br />
DLL : STRUCT CAN Treiber<br />
DLL_0 : STRUCT<br />
T<strong>AG</strong> : STRING [10 ] := 'DLL:';<br />
P1: STRING [10 ] := 'P1 125';<br />
P2: STRING [10 ] := 'P2 1';<br />
I: STRING [10 ] := 'I 0 32';<br />
O: STRING [10 ] := 'O 0 32';<br />
PII: STRING [10 ] := 'PII 0 32';<br />
PIO: STRING [10 ] := 'PIO 0 32';<br />
END : STRING [1 ] := ';';<br />
END_STRUCT;<br />
END_STRUCT;<br />
CAN Fieldbus Controller (DLL)<br />
Die IO-Bereiche werden getrennt mit Lage und Länge definiert.<br />
Offset Length<br />
I 0 32 Eingänge Offset/Länge<br />
O 0 32 Ausgänge Offset/Länge<br />
PII 0 32 Eingangs-Prozessabbild I 0.0..31.7<br />
PIO 0 32 Ausgangs-Prozessabbild O 0.0..31.7<br />
P1 n P1 = CAN-Baudrate 125 oder 250 oder 500<br />
P2 n Anzahl CIO-Module 1 bis max. 16 (� das I/O-Abbild pro Modul hat eine Länge<br />
von 32 Byte, d.h. bei 2 Modulen 64, usw.)<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 21
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Fieldbus Controller Hilscher<br />
Die <strong>AT</strong>-<strong>S7</strong> CPU-<strong>Soft</strong>ware unterstützt die Feldbus Kontroller der CIF PCI/104 - Serie.<br />
CIF : STRUCT<br />
CIF_0 : STRUCT<br />
T<strong>AG</strong> : STRING [10 ] := 'CIF:';<br />
BF: STRING [4 ] := 'BF J';<br />
I: STRING [10 ] := 'I 0 32';<br />
O: STRING [10 ] := 'O 0 32';<br />
PII: STRING [10 ] := 'PII 0 32';<br />
PIO: STRING [10 ] := 'PIO 0 32';<br />
END : STRING [1 ] := ';';<br />
END_STRUCT;<br />
END_STRUCT ;<br />
Hilscher CIF Fieldbus Controller (CIF)<br />
Nicht einstellbar ist die Watchdog Zeit der Profibus (Hilscher/CIF) - Karten.<br />
Dieses wird über das Konfigurationstool SyCon der Fa. Hilscher<br />
durchgeführt.<br />
Die IO-Bereiche werden getrennt mit Lage und Länge definiert.<br />
Offset Length<br />
I 0 32 Eingänge Offset/Länge<br />
O 0 32 Ausgänge Offset/Länge<br />
PII 0 32 Eingangs-Prozessabbild I 0.0..31.7<br />
PIO 0 32 Ausgangs-Prozessabbild O 0.0..31.7<br />
BF<br />
BusFault<br />
J Das DP-Mastersystem ist Watchdog überwacht. In einem Fehlerfall wird der<br />
Watchdog nicht weiter getriggert.<br />
Ein BusFault wird generiert.<br />
Die Ausgänge werden rückgesetzt.<br />
BF N Das DP-Mastersystem ist Watchdog überwacht. In einem Fehlerfall wird der<br />
Watchdog weiter getriggert.<br />
Ein BusFault wird nicht generiert.<br />
Die Ausgänge werden rückgesetzt.<br />
Das Hilscher- und CAN-Feldbus-Interface kann gleichzeitig verwendet werden.<br />
In diesem Fall muss auf eine korrekte Konfiguration des I/O Prozessabbilds<br />
(I/O und PII/PIO) geachtet werden, damit sich die Bereiche im I/O-Abbild nicht<br />
überlappen!<br />
22 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
4.6.2 SYSPARAM Beispiel<br />
Beispiel CAN Interface (CAN-Treiber DLL)<br />
Beispiel Hilscher Feldbus (z.B. Profibus)<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 23
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
4.7 CAN-MASTER, COMPACT-I/O-MODUL CAN<br />
Die <strong>AT</strong>-<strong>S7</strong> unterstützt die Anbindung von bis zu 16 Compact-I/O-Modulen CAN. Die Parametrierung<br />
des CAN-Masters erfolgt über den SYSPARAM-DB (s.a. Kap. SYSPARAM-DB)<br />
4.7.1 Fehlerhandling<br />
Signalisierung<br />
Da der CAN-Treiber über keine direkte Möglichkeit zur Ausgabe einer Fehlernummer verfügt, wird<br />
die Fehlernummer an die <strong>Soft</strong>ware-<strong>SPS</strong> geliefert. Die Fehler können über den Simatic Manager im<br />
Fenster Baugruppenzustand � Diagnosepuffer angezeigt werden. Als Ereignis wird allg. ein<br />
Peripherie-Zugriffsfehler gemeldet.<br />
Verhalten der <strong>Soft</strong>ware-<strong>SPS</strong><br />
Sofern der OB 85 nicht vorhanden ist, geht die <strong>Soft</strong>ware-<strong>SPS</strong> in den Zustand STOP.<br />
Im OB85 kann der Fehlercode im LW10 gelesen werden.<br />
24 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
Fehlercodes<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Nr. Beschreibung Mögliche Ursache<br />
1 parameter error: invalid baud rate Es wurde eine falsche Baudrate<br />
projektiert. Gültig sind die Werte 125,<br />
250, 500<br />
2 parameter error: invalid registry settings Fehlende Registryinformationen<br />
5 CPU416 call argument: no valid buffer Interner Fehler in CPU416.EXE. Kein<br />
(DevSetPEA, DevGetPEA)<br />
6 CPU416 call argument: invalid offset<br />
(DevSetPEA, DevGetPEA)<br />
Puffer für Nutzdaten vorhanden.<br />
Ungültiger Offset für Prozessdatenabbild.<br />
Eventuell Projektierungsfehler in<br />
SYSPARAM<br />
10 CAN controller: no free transmit buffer Kein weiterer CAN-Teilnehmer am Bus<br />
11 CAN controller: can not set reset request CAN-Controller ist defekt<br />
12 CAN controller: bus off detected Kurzschluss am CAN<br />
20 receive queue: can not read valid can<br />
Unvollständige CAN-Message im<br />
message form<br />
Empfangspuffer<br />
21 receive queue: full Thread welcher die Emfangsqueue<br />
abarbeiten soll erhält keine Rechenzeit<br />
30 os error: can not allocate CAN controller Falsche Basisadresse für CAN-Controller<br />
projektiert<br />
31 os error: can not map CAN controller Falsche Basisadresse für CAN-Controller<br />
projektiert<br />
32 os error: can not create thread Windows CE Fehler<br />
33 os error: can not create event Windows CE Fehler<br />
34 os error: can not initialize irq Falscher Interrupt für CAN-Controller<br />
projektiert<br />
41 heartbeat supervision error slave 1 Heartbeat-Überwachung: Slave 1<br />
ausgefallen<br />
42 heartbeat supervision error slave 2 Heartbeat-Überwachung: Slave 2<br />
ausgefallen<br />
43-55 heartbeat supervision error slave 3 - 15 Heartbeat-Überwachung: Slave 3-15<br />
ausgefallen<br />
Anzahl Module/Mindestzykluszeit<br />
Es können bis zu 16 Module am CAN-Bus angeschlossen werden. Pro Modul werden je 4 Transmit-<br />
und 4 Receive PDOs übertragen. Die Übertragung der PDOs zum Modul erfolgt bei Änderung am<br />
Ende des <strong>SPS</strong>-Zyklus. Die Defaultbaudrate ist 125kBit/s. D.h. die Übertragung von 1 PDO mit 8 Byte<br />
benötigt 1ms.<br />
Die Mindestzykluszeit der <strong>SPS</strong> muss grösser als die Übertragungszeit auf dem Bus sein.<br />
MZ = Anzahl Module * 8 PDOs/Modul * Übertragungszeit/PDO = 1 * 8 * 1 = 8ms<br />
Die Mindestzykluszeit der <strong>SPS</strong> muss grösser als die Übertragungszeit der<br />
entsprechenden PDOs auf dem CAN-Bus gewählt werden! Zu geringe<br />
Zykluszeiten können zu Fehlern im CAN-Treiber führen (z.B. Überlauf der<br />
Sendequeue).<br />
Nach einem CAN-Busfehler ist ein Neustart erforderlich.<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 25
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
4.8 KONFIGUR<strong>AT</strong>ION PROFIBUS DP-MASTER<br />
Die Konfiguration des DP-Master erfolgt mit Hilfe des System-Konfigurators Sycon der Firma<br />
Hilscher. (s.a. www.hilscher.com)<br />
Während der Konfiguration des Profibus sollte die <strong>AT</strong>-<strong>S7</strong> aus<br />
Sicherheitsgründen im „Stop“ sein.<br />
Das Zielsystem muss zur Konfiguration des ProfibusDP via Ethernet mit dem PC verbunden sein. Die<br />
Kommunikation zum Zielsystem erfolgt über Ethernet TCP/IP. Hierfür muss im Menü „Einstellungen-<br />
Gerätezuordnung“ der „CIF TCP/IP Treiber“ ausgewählt werden.<br />
Anschliessend kann im folgenden Menü die IP-Adresse des Zielsystem eingestellt werden. Mit<br />
„Connect to Server“ werden die Informationen der DP-Karte angezeigt und das „Board 0“ kann<br />
angewählt werden.<br />
Wichtig ist die Version V1.121. Mit neueren Versionen des Treibers treten<br />
zumindest unter WinXP Kommunikationsprobleme auf!<br />
26 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Steht im Feld Name „Bootstraploader...“, so muss auf dem Gerät die Profibus<br />
FW geladen werden. (s.a. Utility IoCfg.exe auf StorageCard\Tools)<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 27
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Der DP-Master wird über Einfügen Master „EC1-DEB-DPM“ und Hinzufügen wie folgt eingefügt:<br />
Anschliessend kann der DP-Master über das Menü „Einstellungen-Busparameter, -<br />
Mastereinstellungen bzw. Masterkonfiguration“ konfiguriert werden. Für die Übergabe der<br />
Prozessdaten sollte der Modus „gepuffert, anwendergesteuert“ verwendet werden.<br />
28 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
Die Konfiguration der Slaves erfolgt analog mit „Einfügen-Slave“:<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Die benötigten GSD-Dateien müssen im entsprechenden SYCON-Verzeichnis z.B.<br />
„C:\Programme\Hilscher\SyCon\Fieldbus\PROFIBUS\GSD“ abgelegt werden.<br />
Die Profibus-Konfiguration kann nun mit „Online-Download“ geladen und anschliessend mit „Online-<br />
Debugmodus“ getestet werden. (weitere Informationen entnehmen Sie bitte der “SyCon Online Help“)<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 29
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
4.9 KOMMUNIK<strong>AT</strong>ION<br />
4.9.1 Allgemein<br />
Die Kommunikation ist ein integraler Bestandteil der <strong>AT</strong>-<strong>S7</strong>-<strong>Soft</strong>ware. Der hierarchisch modulare<br />
Aufbau erlaubt die Adaption unterschiedlicher Treiber und somit das Senden und Empfangen von<br />
Daten.<br />
Das logische Datenhandling findet über Kommunikations-SFCs statt, welche immer komplette<br />
Datenblöcke senden und empfangen. Dateninkonsistenzen in der CPU sind somit ausgeschlossen.<br />
Die Festlegung, wann Daten an die Steuerung übergeben, bzw. übernommen werden, findet mit der<br />
Verbindungsparametrierung statt. Es werden drei Modi unterschieden:<br />
- freilaufend<br />
- zyklussynchron<br />
- Programm gesteuert<br />
Die Verbindungsparametrierung erfolgt mit dem Parametriertool ABC-Project.<br />
4.9.2 Kommunikation zur Visualisierung EPAM<br />
Die Kommunikation zum Visualisierungstool EPAM erfolgt via TCP/IP und den <strong>AT</strong>-<strong>S7</strong> Treiber. (s.a.<br />
EPAM Handbuch). Das Lesen von Variablen erfolgt freilaufend (d.h. nicht zyklussynchron) und das<br />
Schreiben von Variablen zyklussynchron.<br />
Es können max. 2 Kommunikationskanäle gleichzeitig betrieben werden, wobei ein Kanal für die<br />
lokale Visualisierung und der zweite Kanal für eine Remote-Verbindung z.B. für die EPAM-Simulation<br />
oder für WinEPAM verwendet werden kann.<br />
Die Visualisierung kann träge werden, wenn die Mindestzykluszeit zu gering gewählt<br />
wird (s.a. Kap. Systemdatenbausteine)<br />
Test der Visualisierung auf dem PC<br />
Die Visualisierung kann zusammen mit dem <strong>SPS</strong>-Projekt ohne Hardware-<strong>SPS</strong> auf dem<br />
PC getestet werden. Hierfür kann die Demoversion der CPU416 für Windows XP<br />
(W32416.exe) von ABC-IT (www.abcit.de) auf dem PC installiert werden. Beim CP-443<br />
muss dann die IP-Adresse des PCs eingestellt werden, um das <strong>SPS</strong>-Projekt zu laden.<br />
EPAM kann mit der Einstellung „LOCALHOST“ betrieben werden.<br />
4.9.3 Kommunikationsbausteine<br />
Die Kommunikation wird über die in der <strong>AT</strong>-<strong>S7</strong>-<strong>Soft</strong>ware integrierten SFCs abgewickelt.<br />
Die kompletten Anwender FCs/FBs werden von diesen Kommunikationsbausteinen abgeleitet. Hierzu<br />
zählen u.a. die Bausteine der <strong>S7</strong>-Bibliothek (L_Send, L_Receive).<br />
Diese Bausteine werden soweit benötigt von der ABC IT geliefert.<br />
Folgende SFCs sind integriert:<br />
SFC244 (HTB_FUNC – SR)<br />
SFC246 (HTB_FUNC – RW)<br />
SFC247 (HTB_FUNC – CONTROL)<br />
SFC248 (HTB_FUNC – RESET)<br />
SFC249 (HTB_FUNC – SYNCHRON)<br />
30 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Die SFCs werden in der <strong>S7</strong>-Bibliothek nicht gefunden. Somit stehen Typ- und Parameter der Bausteine<br />
nicht zur Verfügung.<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 31
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Programmierung FC244<br />
FC244 Parameter int. Kommunikationskontroller<br />
FC244 Aufrufparameter ext. Kommunikationskontroller<br />
FC244 Aufrufparameter int. Hintergrundkommunikation<br />
32 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
Programmierung FC246<br />
FC244 Aufrufparameter ext. Hintergrundkommunikation<br />
FC246 Aufrufparameter int. Kommunikationskontroller<br />
FC246 Aufrufparameter ext. Kommunikationskontroller<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 33
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Programmierung FC247<br />
Programmierung FC248<br />
FC247 Aufrufparameter int./ext. Kommunikationskontroller<br />
FC248 Aufrufparameter int./ext. Kommunikationskontroller<br />
34 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
Programmierung FC249<br />
4.9.4 Datenkopplung Ethernet TCP/IP<br />
Folgende Datenkopplungen werden unterstützt:<br />
- Socket Schnittstelle<br />
- Send/Receive via TCP u. UDP<br />
- Fetch/Write<br />
- RFC1006 Schnittstelle<br />
- Send/Receive via TCP<br />
- Fetch/Write<br />
- <strong>S7</strong>-Verbindung passiv<br />
Allgemein<br />
FC249 Aufrufparameter int./ext. Kommunikationskontroller<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>-<strong>SPS</strong><br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>-<strong>SPS</strong><br />
Zellenkommunikation<br />
Ethernet TCP/IP<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 35
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
GUI-PC<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>-<strong>SPS</strong><br />
Visualisierung<br />
Verbindungs - Projektierung mit ABC-Project<br />
ABC-Project v2.0 Verbindungsparametrieung<br />
Ethernet TCP/IP<br />
Parameter:<br />
• Es werden die Protokolle TCP und UDP (Send/Receive) unterstützt.<br />
• Die Local ID muss eine ungerade Zahl im Zahlenraum 1..253 sein. Diese entspricht der A-<br />
NR der Kommunikationsbausteine.<br />
• Bei Send/Receive ist der ungeraden ID der Send und der geraden ID der Receive<br />
zugeordnet (z.B. 1->Send, 2->Receive)<br />
• Mit der Vergabe einer Device-ID ungleich null, werden spezielle Funktionen parametriert.<br />
• Name hat keine Funktion und dient ausschliesslich dokumentarischen zwecken.<br />
• A/P definiert den aktiven und passiven Verbindungsaufbau.<br />
36 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
Service Beschreibung<br />
Send/Receive Nutzdatenkommunikation allgemein<br />
Fetch/Write<br />
S5<br />
Datenzugriff auf das X5 Mengengerüst<br />
Fetch/Write<br />
<strong>S7</strong><br />
<strong>S7</strong>-<br />
Verbindung<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Datenzugriff auf das X7 Mengengerüst; Migration u. Konventionen beachten<br />
Datenzugriff auf das X7 Mengengerüst<br />
• Mit dem Parameter Typ findet eine Unterscheidung zwischen der SOCKET- und der<br />
RFC1006-Kommunikation statt.<br />
• Lokaler/Fremder Port ist ein Teil der TCP/IP Verbindungsparameter und vom Typ<br />
der Verbindung abhängig.<br />
Typ Port Description<br />
SOCKET z.B. 5001,<br />
20100<br />
RFC1006 112233 (ASCII)<br />
x112233 (HEX)<br />
TCP/IP Verb.-Parameter<br />
Remote Port 0 -> Port-Definition des Partners wird immer<br />
aktzeptiert<br />
TSAP der RFC1006-Parameter<br />
Remote Port leeres Feld -> TSAP-Definition des Partners wird<br />
immer aktzeptiert<br />
• Fremde IP-Adr ist ein Teil der TCP/IP – Verbindungsparameter.<br />
• Mit der Device-ID werden systemspezifische Einstellungen vorgenommen. Folgende<br />
Einstellungen sind z.Zt. möglich:<br />
Device-ID Description<br />
x0<br />
Die CPU-Mischvarianten (CPU416 mit CPU945/948) unterscheiden an dieser Stelle<br />
den Datenzugriff auf S5- und <strong>S7</strong>-Bereiche.<br />
x1<br />
0: Zugriff auf S5-Datenbereiche<br />
1: Zugriff auf <strong>S7</strong>-Datenbereiche<br />
0x Die Datenübergabe zur X5/X7 erfolgt freilaufend. D.h., Daten werden während<br />
des <strong>SPS</strong>-Zyklus gelesen und auch geschrieben.<br />
1x Die Datenübergabe zur X5/X7 erfolgt Zyklus-Synchron. D.h., dass die Daten am<br />
Kontrollpunkt gelesen und geschrieben werden.<br />
2x Die Datenübergabe zur X5/X7 erfolgt Anwender-Synchron. D.h., dass die Daten an<br />
den ALL-Hantierungsbausteinen gelesen und geschrieben werden.<br />
3x Kombination aus Device ID 10 und 20<br />
Es werden immer komplette Telegramme bei Fetch/Write u. <strong>S7</strong>-Verbindung gelesen und<br />
geschrieben. Bei geblockten RFC1006-Telegrammen wird immer ein Block komplett<br />
gelesen/geschrieben.<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 37
5 Programmierung der Steuerung<br />
Die Programmierung der Steuerung erfolgt über Ethernet mit TCP/IP Protokoll.<br />
5.1 VERBINDUNG DES PROGRAMMIER-PC MIT DER STEUERUNG<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Bei einer direkten Verbindung, ohne Ethernet-Hub oder Switch, ist ein gekreuztes "Crosslink" Kabel<br />
zu verwenden. Steuerungsseitig ist eine standardisierte RJ45 Buchse angebracht.<br />
Erfolgt die Ethernetverbindung über einen Ethernet-Hub bzw. Switch sind von Hub zur Steuerung wie<br />
zum Programmier-PC nicht gekreuzte Kabel (patch) einzusetzen.<br />
5.2 EINSTELLUNG DES PROGRAMMIER-PC FÜR DIE ETHERNET-KOMMUNIK<strong>AT</strong>ION<br />
Auf dem Programmier-PC muss ein Netzwerkadapter und das TCP/IP Protokoll installiert sein. Auf<br />
der Steuerung muss eine zum Programmier-PC passende IP-Adresse z.B. im gleichen Subnetz<br />
eingestellt werden.<br />
Kontaktieren Sie hierfür ggf. Ihren Netzwerk-Administrator.<br />
Beispiel einer möglichen Konfiguration:<br />
Programmier-PC: 192.168.0.99<br />
Steuerung: 192.168.0.100<br />
Subnetz-Maske auf beiden Geräten: 255.255.255.0<br />
Die Kommunikation zwischen PC und Steuerung kann einfach mit dem<br />
Kommandozeilen-Befehl ping „IP-Adresse“ überprüft werden. Meldet das<br />
Programm ping Timeouts, so sind entweder die Verkabelung oder die TCP/IP-<br />
Einstellungen nicht korrekt.<br />
5.3 EINSTELLUNG DER ETHERNET KOMMUNIK<strong>AT</strong>ION IM SIM<strong>AT</strong>IC-MAN<strong>AG</strong>ER<br />
Die Einstellung der IP-Adresse der Steuerung erfolgt im SIM<strong>AT</strong>IC-Manager im Menü „Extras-PG/PC-<br />
Schnittstelle einstellen“. Zur Kommunikation über Ethernet muss der TCP/IP- „Netzwerkkarte“<br />
ausgewählt werden.<br />
TCP/IP -> „Netzwerkkarte“<br />
„Netzwerkkarte“ ist die Bezeichnung der Ethernet-Schnittstelle des PCs. Diese<br />
ist PC spezifisch. (s.a. Systemsteuerung-Netzwerkverbindungen)<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 38
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
Die IP-Adresse des Gerätes wird in der Hardware-Konfiguration des CP 443-1 TCP eingegeben.<br />
5.4 EINSTELLUNG DER IP-ADRESSE AUF DEM ZIELSYSTEM<br />
Die IP-Adresse kann über das Control-Panel auf den WindowsCE Geräten („Start-Settings-Network and<br />
Dial-up Connections“ s.a. Systembeschreibung WindowsCE) oder mit einer EPAM-Applikation<br />
eingestellt werden. (s.a. EPAM-Handbuch). Die Einstellung kann mit Start-Run-FlushRegistry2<br />
netzausfallsicher gespeichert werden.<br />
5.5 PROJEKT-DOWNLOAD<br />
Der Projektdownload erfolgt über die Funktion „Laden“ des SIM<strong>AT</strong>IC Managers. Bei Änderungen in<br />
den <strong>Systeme</strong>instellungen ist die Reihenfolge zu beachten (s.a. Kap. Systemdatenbausteine bzw.<br />
SYSPARAM-DB).<br />
Der Projektdownload erfolgt nach Quittierung der folgenden Meldung:<br />
In der Zeile Firmwareversion wird die aktuellle <strong>Soft</strong>ware Version der <strong>AT</strong>-<strong>S7</strong><br />
angezeigt.<br />
Das Anwenderprogramm kann mit dem SIM<strong>AT</strong>IC-Manager Befehl „RAM nach ROM kopieren“ auf das<br />
CompactFlash kopiert werden. (s.a. Startverhalten/Anlauf)<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 39
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
6 Versionsgeschichte<br />
Version Datum / Visum Änderungen :<br />
1.0 12-06 / Fis Erstversion<br />
2.0 03-07 / Fis Anpassungen für <strong>AT</strong>-<strong>S7</strong> V1.6<br />
S.7 Hinweis Urlöschen<br />
S.10 Remanente Daten<br />
Neu S.10 Hardware Konfiguration<br />
S.12 Systemfunktionen<br />
S.15 Systemdatenbausteine<br />
S.19 SYSPARAM-DB<br />
Neu S.20, 23ff CAN-Master<br />
S.27 Kommunikation zur Visualisierung EPAM<br />
Neu S.35 Projekt Download<br />
3.0 04-07 / Fis S.9,19 SYSPARAM-DB initialisiseren<br />
S.10 neue Funktion Initialisierung der Anfangswerte zum Zeitpunkt<br />
„RAM nach ROM“ kopieren<br />
S.20 neu Projekt Information Parameter (PIP), CAN-Parameter „BF J“<br />
entfernt<br />
S.22 neue Beispiele Sysparam-DB<br />
S.23,24 neue Fehlerdiagnose CAN<br />
S. 25,26 Konfiguration des DB-Master<br />
<strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong><br />
Spinnereistrasse 10<br />
CH-9008 St.Gallen<br />
Schweiz<br />
Tel : +41(0)71/243 29 29<br />
Fax : +41(0)71/243 29 28<br />
Email : info@gesys.ch<br />
Internet : www.gesys.ch<br />
40 DVS 51002 V3.0 © 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong>
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 41
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>- <strong>SPS</strong><br />
Runtime-<strong>Systeme</strong> <strong>Soft</strong>ware<br />
7 Stichwortverzeichnis<br />
A<br />
<strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>-<strong>SPS</strong> ............................................. 9<br />
D<br />
Datenkopplung Ethernet TCP/IP ............. 32<br />
E<br />
Einleitung.................................................... 5<br />
Einstellung der IP-Adresse auf dem Zielsystem<br />
.............................................................. 36<br />
Einstellung des Programmier-PC für die<br />
Ethernet-Kommunikation........................ 35<br />
F<br />
Fieldbus Controller CAN ........................... 20<br />
Fieldbus Controller Hilscher ..................... 21<br />
H<br />
Hardware Konfiguration ............................ 10<br />
Herstelleradresse ...................................... 37<br />
I<br />
IEC Function Blocks ................................... 18<br />
Inhaltsverzeichnis ....................................... 3<br />
Initialisierung der remanenten Daten ........ 10<br />
Installation.................................................. 7<br />
K<br />
Kommunikation......................................... 28<br />
Kommunikation zur Visualisierung EPAM28<br />
Kommunikationsbausteine ..................... 28<br />
Kompatibilität ............................................. 9<br />
Konfiguration der <strong>AT</strong>-<strong>S7</strong> <strong>Soft</strong>-<strong>SPS</strong>............... 19<br />
Konfiguration Profibus DP-Master .............. 25<br />
L<br />
Leistungsmerkmale/Mengengerüst.............. 9<br />
M<br />
Mengengerüst ............................................. 9<br />
O<br />
Online Funktionen....................................11<br />
Organisationsbausteine...........................11<br />
P<br />
Performance ................................................9<br />
Programmierung der Steuerung .................35<br />
Programmierung FC244 .............................29<br />
Programmierung FC246 .............................30<br />
Programmierung FC247 .............................31<br />
Programmierung FC248 .............................31<br />
Programmierung FC249 .............................32<br />
Projekt Information Parameter (PIP) ............20<br />
Projekt-Download ......................................36<br />
R<br />
RAM nach ROM kopieren............................11<br />
Remanente Daten ..................................9, 10<br />
Runtime-System ...........................................7<br />
Runtime-System Update ...............................7<br />
S<br />
S5-<strong>S7</strong> Converting Blocks ............................16<br />
<strong>S7</strong> Standard Library (stdlib30) .................16<br />
SIM<strong>AT</strong>IC Manager.......................................10<br />
Startverhalten/Anlauf...................................9<br />
Symbolerklärung..........................................4<br />
SYSPARAM Beispiel ..................................22<br />
SYSPARAM-DB...........................................19<br />
System Dependent Parameter (SDP)............19<br />
Systemdatenbausteine.............................15<br />
Systemfunktionen ....................................12<br />
Systemfunktionsbausteine ......................14<br />
© 2010 by <strong>Grossenbacher</strong> <strong>Systeme</strong> <strong>AG</strong> DVS 51002 V3.0 43<br />
V<br />
Verbindung des Programmier-PC mit der<br />
Steuerung...............................................35<br />
Versionsgeschichte ....................................37