Assembly<br />

Attention!<br />

The fitting must be installed, flushed and tested after<br />

the valid norms!<br />

1. Flush through the supply pipes.<br />

2. Fasten the mixer with the washers.<br />

Large differences in pressure between the hot and<br />

cold water supply should be balanced.<br />

Adjustment<br />

Correction is necessary if the temperature measured<br />

at the take off point differs from the temperature set<br />

on the scale. To adjust please see page 7.<br />

Operation<br />

The mixer is operated by turning the handle on the<br />

left hand side.<br />

The temperature is selected by turning the graduated<br />

handle on the right side.<br />

The flow of the bath mixer can be changed from<br />

tub to shower function by simply pulling the diverter<br />

knob located at the top of the outlet.When the water<br />

is shut off the flow returns automatically to the bath<br />

function.<br />

To garantee a smooth running of the thermoelent, it<br />

is necessary from time to time to turn the thermostat<br />

from total hot to total cold.<br />

English<br />

Attention!<br />

The mixer is equipped with non return valves.<br />

The non return valves must be checked regularly according<br />

to DIN EN 1717 in accordance with national<br />

or regional regulations (at least once a year).<br />

Technical Data<br />

Operating pressure: max. 1 MPa<br />

Recommended operating pressure: 0,1 - 0,5 MPa<br />

Test pressure: 1,6 MPa<br />

Hot water temperature: max. 80° C<br />

Recommended hot water temp.: 65° C<br />

Rate of flow tub spout: 58 l/min by 0,3 MPa<br />

Rate of flow shower outlet: 18 l/min by 0,3 MPa<br />

antipollution function<br />

(1 MPa = 10 bars = 147 PSI)<br />

Spare parts (see page 2)<br />

1 thermoelement 96633000<br />

2 shut off unit 92929000<br />

3 handel 98870000<br />

4 diverter fixing device 97211000<br />

5 aerator cpl. 97163000<br />

6 diverter knob 96488000<br />

7 selector cpl. 97164000<br />

8 connecting thread cpl. 97210000<br />

9 filter packing 96922000