B. Installation and Start of Operation of the <strong>Dosing</strong> <strong>Unit</strong><br />

• Station the dosing unit as close to the filter unit as possible.<br />

Mount the included hose nozzle (2) to the transition piece or the connection box (1)<br />

on the air inlet side of the filter unit.<br />

• Connect the coupler of the hose (3) of the dosing unit with the hose nozzle (2)<br />

via the included hose (4).<br />

• Connect the compressed air supply (4-6 bar) to the dosing unit (5).<br />

• Plug the control cable (6) of the dosing unit into the adequate jack of the filter unit.<br />

• Open the lid of the housing of the dosing unit and fill in the pre-<strong>coating</strong> powder<br />

(part no.: 1090275). Protective gloves and a protection mask should be worn during<br />

loading of the unit (please see also in<strong>for</strong>mation on the packing of the pre-<strong>coating</strong> powder)<br />

• The filter unit with the dosing unit is now ready <strong>for</strong> operation.<br />

<strong>Dosing</strong> unit<br />

In<strong>for</strong>mation:<br />

It is obligatory to run the filter unit together with pre-<strong>coating</strong> powder.<br />

For this reason you should store sufficient pre-<strong>coating</strong> powder (part no.: 1090275).<br />

Using the filter unit without pre-<strong>coating</strong> can cause damages to the filter cartridges.<br />

For some welding techniques it is necessary to impregnate the filter cartridges with a pre<strong>coating</strong><br />

powder. This powder has to be compressed on the filter cartridge and it can happen that the<br />