Start the generator first, then connect the welding unit. The idle voltage should be set to approx. 240 volts,<br />
adjust the voltage if needed. When turning the generator off, disconnect the welding unit first.<br />
CAUTION! The working output power of the generator decreases by about 10% per 1,000 m of altitude.<br />
During the welding process no further devices connected to the same generator should be operated.<br />
3 Service and Repair<br />
As the unit is used in applications that are sensitive to safety considerations, it may be serviced and repaired<br />
only on our premises or by partners who were specifically trained and authorized by us. Thus,<br />
constantly high standards of operation quality and safety are maintained.<br />
IMPORTANT!<br />
Non-compliance with this provision will dispense the manufacturer from any warranty and liability claims<br />
for the unit and any consequential damage.<br />
When serviced, the unit is automatically upgraded to the technical specifications with which the product is<br />
currently shipped, and we grant a three- month functional warranty on the serviced unit.<br />
We recommend having the device serviced at least every twelve months. In Germany, keep in mind the<br />
follow-up check under BGV A3!<br />
3.1 Transport, Storage, Shipment<br />
The <strong>ROWELD</strong> <strong>ROFUSE</strong> <strong>Basic</strong> <strong>48</strong> is shipped in a box.<br />
Store the <strong>ROWELD</strong> <strong>ROFUSE</strong> <strong>Basic</strong> <strong>48</strong> in the transport box dry and protected from humidity.<br />
When shipped, the welding unit should be placed into the transport box at any time.<br />
4 Check-out and Principle of Operation<br />
• To operate the <strong>ROWELD</strong> ® <strong>ROFUSE</strong> <strong>Basic</strong> <strong>48</strong> Welding Unit, be sure that it is positioned on a proper<br />
surface.<br />
• Be sure that power supply/generator protection is 16 A (slow).<br />
• Plug the power supply cord into the mains power supply or the generator.<br />
• Read and comply with the User’s Manual.<br />
• Check the unit for damage.<br />
• Have problems repaired.<br />
The <strong>ROWELD</strong> <strong>ROFUSE</strong> <strong>Basic</strong> <strong>48</strong> allows welding electrofusion fittings that feature a bar code, provided it<br />
conforms to the specification set by the standard ISO TR 13950 Every fitting is provided with a tag with<br />
the bar code on it. The code contains information about the proper welding of the component. It also allows<br />
entering some of these data manually.<br />
Before welding starts, a temperature sensor on the welding cable checks the ambient temperature, and<br />
the welding transformer temperature is monitored while welding is in progress. The microprocessorcontrolled<br />
<strong>ROWELD</strong> <strong>ROFUSE</strong> <strong>Basic</strong> <strong>48</strong> Welding Unit:-<br />
• controls and monitors the welding process in a fully automated way,<br />
• determines welding duration depending on the ambient temperature,<br />
• additionally records the characteristics of the welding process to a report.<br />
With a generator, the <strong>ROWELD</strong> <strong>ROFUSE</strong> <strong>Basic</strong> <strong>48</strong> has to be operated at 220 - 240 volts AC with a frequency<br />
of 50 - 60 Hz. If one of these parameters is outside the tolerance thresholds, the unit stops operation<br />
after 15 seconds or refuses to start operation.<br />
17