37<br />

SAFETY NEEdS<br />

EvIdENCE<br />

The following tests have been carried out in accordance with<br />

IACS URP 2.2 and DIN 86128:<br />

Tightness test<br />

• 1.5 x PN<br />

• 5 min. tight<br />

Vibration test<br />

• 1 x PN<br />

• 3 x 106 cycles<br />

• Amplitude 0,06 / 0,5 / 1,5 mm<br />

• Frequency 100 / 45 / 10 Hz<br />

Burst pressure test<br />

• 4 x PN<br />

• 5 min. tight<br />

Pull-out-test<br />

• 1x PN + Fax (PN as appropriate)<br />

• 5 min. without leakage or other faults<br />

Fire-endurance test<br />

In accordance with ISO 19921 and 19922<br />

• 1 x PN<br />

• 30 min.<br />

• 800° C<br />

• Pressure test: 2 x PN; 5 min. tight<br />

Vacuum test<br />

• 170 mbar absolute<br />

• 5 minutes tight<br />

Repeated assembly test<br />

• 10 x assembly and dismantling<br />

• 1.5 x PN pressure test<br />

• 5 min. tight<br />

Other tests:<br />

Pressure pulsation test<br />

For STRAUB couplings not required<br />

• Pressure pulsation 0 bar up to 1.5 x PN<br />

• 30 – 100 cycles per minute<br />

• 5 x 105 cycles<br />

• No leakage, no plastic deformation<br />

Shock test<br />

• Acceleration 140g surface ships<br />

• Acceleration 200g submarines<br />

(for CuNiFe and C steel pipes)<br />

Angular deflection test<br />

• Angular deflection 20°<br />

• 20 bar; 114.3 mm<br />

• 5 min. tight<br />

Jump test<br />

• 1 x PN<br />

• Impact of 100 kg weight on coupling<br />

• No leakage<br />

• Angular deflection approx. 20°