23.02.2013 Views

Mini-X-Purge Size 1 Manual ML 442 - Expo Technologies

Mini-X-Purge Size 1 Manual ML 442 - Expo Technologies

Mini-X-Purge Size 1 Manual ML 442 - Expo Technologies

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

System fails to switch power<br />

on after the purge time has<br />

elapsed.<br />

Is Power<br />

available?<br />

Yes<br />

Is Power<br />

isolator closed?<br />

Yes<br />

Are the fuses or<br />

circuit breaker?<br />

OK?<br />

Yes<br />

Has the purge<br />

time completed<br />

its course?<br />

Yes<br />

For PO option only<br />

Is there pressure at the<br />

power switch output<br />

bulkhead and at the<br />

power switch? Is the<br />

power switch OK?<br />

Yes<br />

For PO option only<br />

Is the tube to the<br />

power switch air<br />

tight?<br />

Yes<br />

Is the <strong>Purge</strong><br />

time correct?<br />

Yes<br />

Call <strong>Expo</strong><br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

Check the small<br />

indicator button<br />

on the timer<br />

valve. When the<br />

valve has timed<br />

out, it should<br />

return out when<br />

depressed.<br />

Check if the<br />

external Power<br />

Switch contacts<br />

close at 1.4 Barg<br />

Ensure fitting nuts<br />

are tightened and<br />

that the tube is not<br />

damaged. Check<br />

and repair as<br />

necessary.<br />

Note the timer setting. Reset the timer to the<br />

minimum available purging period and check<br />

the operation on that purge time.<br />

Ensure that the purge time is returned to<br />

its original setting and checked before<br />

putting the system back into service.<br />

<strong>ML</strong> <strong>442</strong> Issue 5C SP5115 09/11/12 ©<br />

Page 20 of 22<br />

No