CONTENTS<br />

Type des. Part no.<br />

Prep. Olof Kjellgren Doc. kind No. of p.<br />

Appr.<br />

Resp. dept. RCI<br />

<strong>Remote</strong> <strong>FlexPendant</strong> <strong>Tester</strong><br />

1. INTRODUCTION ....................................................................................................... 2<br />

1.1 Purpose........................................................................................................ 2<br />

1.2 Definitions .................................................................................................... 2<br />

1.3 Equipment.................................................................................................... 2<br />

2. Installation and setup .............................................................................................. 3<br />

3. <strong>FlexPendant</strong> TestMaker........................................................................................... 5<br />

3.1 Overview of the GUI..................................................................................... 5<br />

3.2 Detailed Description ..................................................................................... 6<br />

3.2.1 Controls.......................................................................................... 6<br />

3.2.2 Test ................................................................................................ 6<br />

3.2.3 Settings .......................................................................................... 6<br />

3.2.4 Actions............................................................................................ 6<br />

3.2.5 Testcase treeview........................................................................... 6<br />

3.2.6 Tips and Tricks ............................................................................... 6<br />

4. <strong>FlexPendant</strong> Robot<strong>Tester</strong>........................................................................................ 8<br />

4.1 Overview of the GUI..................................................................................... 8<br />

4.2 Detailed description...................................................................................... 9<br />

4.2.1 Run Section.................................................................................... 9<br />

4.2.2 Execution Section........................................................................... 9<br />

4.2.3 Settings Section.............................................................................. 9<br />

4.2.4 Tips and Tricks ............................................................................... 9<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Title <strong>Remote</strong> <strong>FlexPendant</strong> <strong>Tester</strong><br />

Doc. no. Lang. Rev. ind. Page<br />

! " #$ % # & ' % % ( # ! ) * ( ! $ * + , -. / -0 / / 1 2 / 3 4 / / %<br />

W<br />

0.1<br />

1


1. INTRODUCTION<br />

1.1 Purpose<br />

1.2 Definitions<br />

1.3 Equipment<br />

The purpose of this document is to describe how to setup tests for the <strong>FlexPendant</strong> run by<br />

remote control.<br />

Word Description<br />

FP <strong>FlexPendant</strong><br />

RSO Robot Studio Online<br />

GUI Graphical User Interface<br />

TestMaker Program to record tests<br />

<strong>Remote</strong><strong>Tester</strong> Program to replay tests<br />

• Test Rack<br />

• <strong>FlexPendant</strong><br />

• Computer with 2 network cards<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Doc. no. Lang. Rev. ind. Page<br />

2


2. Installation and setup<br />

Follow these steps to install and set up the testing system.<br />

1. Connections<br />

The Computer running the tests must be able to communicate directly with the FP. Set up<br />

a switch and configure the second network card to have the IP address 192.168.126.x<br />

(where x = 2 – 253) and subnet mask 255.255.255.0.<br />

2. <strong>FlexPendant</strong> logging<br />

The <strong>FlexPendant</strong> sends information, e.g., when error occurs. This information can be<br />

displayed using a tool called nclog. The program (nc.exe) is located at<br />

S:\Product Development\DevelopmentProjects\GTPU\Tools\netcat<br />

In the command window, write “nc –lup 9998”. It is recommended to have the nclog<br />

running from this point on.<br />

3. Verify connection<br />

Power on the Test Rack and verify that it is possible to get in contact with the FP by using<br />

“ping 192.168.126.10” from a command window.<br />

4. FTP Server<br />

Install and configure the FTP server. There is a Free-ware FTP Server, zFTPServer<br />

available at http://www.zftpserver.com/.<br />

It is possible to use any FTP server.<br />

Create the following usergroup:<br />

Name: FPTest<br />

Home directory: c:\temp\FPTests<br />

File rights: All<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Doc. no. Lang. Rev. ind. Page<br />

3


Folder rights: Read, +subfolders<br />

Create the following user belonging to FPTest<br />

Name: ps<br />

Password: ps<br />

5. <strong>FlexPendant</strong> Viewer<br />

Install the <strong>FlexPendant</strong> Viewer from<br />

Z:\integration\rel5_xx\mmi\BuildLib\Tools\<strong>FlexPendant</strong> Viewer<br />

6. Naming the Controller<br />

Set name of the controller to “<strong>Remote</strong>Test”.<br />

This is because images are compared by the <strong>FlexPendant</strong> and the controller name is<br />

always displayed.<br />

This can be done in RSO. Add the Controller. Press Controller->Properties->Rename.<br />

You need Write Access to be able to do this.<br />

7. Install software<br />

Install the RobotWare.<br />

8. Create a System<br />

Create a new system using RSO.<br />

Set name of the system to “System<strong>Remote</strong>Test”. This is because images are compared of<br />

the <strong>FlexPendant</strong> and the system name is always displayed.<br />

9. Start FTP Server<br />

Start the FTP Server if it is not running.<br />

10. Start <strong>FlexPendant</strong> Viewer<br />

Start the <strong>FlexPendant</strong> Viewer if it is not running. This application will make it possible to<br />

remotely control the <strong>FlexPendant</strong>.<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Doc. no. Lang. Rev. ind. Page<br />

4


3. <strong>FlexPendant</strong> TestMaker<br />

3.1 Overview of the GUI.<br />

Start/Stop capturing<br />

coordinates and<br />

Save Test.<br />

Test Name and<br />

Folder to save tests<br />

into.<br />

Current test. Test is<br />

not affected if you<br />

enter or delete text<br />

directly into it.<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Clear: Deletes all<br />

actions and begin<br />

from scratch.<br />

Reload: update<br />

test folder<br />

Commands for<br />

tests.<br />

Snap: captures<br />

image<br />

Restart: restarts<br />

FP only<br />

Wait: holds tests<br />

for X seconds.<br />

Include Test: call<br />

another test.<br />

Always snap:<br />

Automatically<br />

snaps image after<br />

each click after 8<br />

seconds. Use<br />

carefully!<br />

Under<br />

\ABB<br />

or<br />

\Quick<br />

Set it is possible to<br />

collect small<br />

testactions which<br />

can be included<br />

into another test.<br />

This makes test<br />

creation much<br />

more rapid. These<br />

tests show up<br />

here.<br />

Doc. no. Lang. Rev. ind. Page<br />

5


3.2 Detailed Description<br />

3.2.1 Controls<br />

• Start: Starts the mouse capturing functionality. The “Pos:”-label will start to update with screen<br />

coordinates.<br />

When this is active, only press on the <strong>Remote</strong>Display window of the FP to save action as a click.<br />

This click will also update the FP normally.<br />

• Stop: Stops mouse capturing.<br />

• Save: Saves all actions so far to the given path with the given filename.<br />

3.2.2 Test<br />

• New Test: This button sets up all folders necessary for the test in the folder.<br />

• Folder: This sets up the folder. Under this all created tests will be saved.<br />

3.2.3 Settings<br />

• Computer IP: Select which IP the network card has, that is connected to the FP net.<br />

3.2.4 Actions<br />

These instruction are available from the Test-script language of <strong>Remote</strong> <strong>FlexPendant</strong> <strong>Tester</strong>.<br />

• Snap: Takes a snapshot from the FP. The command is sent via socket communication to the FP<br />

which uploads the image to an FTP on the computer. An FTP-Server has to be installed to use<br />

this feature.<br />

• Restart FP: Orders a restart from the FP. The command is sent via socket communication to the<br />

FP.<br />

• Wait Xs: Orders system to wait. Useful after example ordering a restart or after clicking on a view<br />

that takes a substantial amount of time to open.<br />

• Include test: Executes a whole other test as an instruction. Useful to build test hierarchies with<br />

low level test scripts that combines into high level test scripts.<br />

3.2.5 Testcase treeview<br />

The testcase treeview (the view to the right on the testmaker) is a library of tests that the user can<br />

create. These tests are loaded from the ‘ABB’ and ‘QuickSet’ subfolders under the .<br />

3.2.6 Tips and Tricks<br />

A recommended way to create tests is first to create a new subfolder under called<br />

‘LowLevelTests’ or something similar. Then create several tests that contain only one click. For example<br />

“ClickABB-Button” or “ClickJoggingView” etc. Then create a new test called OpenJoggingView that<br />

includes these two tests and place it under \ABB\Jogging. This test it not meant to be run<br />

itself, but as a ‘medium level’ test. Combining several medium level tests and adding images<br />

comparisons and the other functions can make a base for very rapid and powerful test creations that are<br />

also robust. If a button in the FP GUI were to change place, all you have to do is replace the low level<br />

test that press that button and all tests pressing the button will work again.<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Doc. no. Lang. Rev. ind. Page<br />

6


To create reliable tests, it’s important that each test “cleans up” after itself (undo all actions), so each test<br />

will start with system in the same state. Otherwise all test cases have to be run in a specific order to be<br />

successful, and any failed tests will probably make all following tests fail as well.<br />

The following picture illustrates how test cases can be built up. For example, if the ABB-button changes<br />

location on the touch screen, only the pressABBButton test case needs to be changed for all tests<br />

pressing that button to work.<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Doc. no. Lang. Rev. ind. Page<br />

7


Reloads list.<br />

List of availble<br />

test cases.<br />

Button for<br />

stopping<br />

execution.<br />

Debug<br />

information.<br />

4. <strong>FlexPendant</strong> Robot<strong>Tester</strong><br />

4.1 Overview of the GUI<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Adds tests to<br />

be run.<br />

Clears list.<br />

Buttons for<br />

running tests.<br />

Controller IP. Computer IP. Extra<br />

Where<br />

waittime<br />

before next<br />

instrucition.<br />

Default = 5.<br />

tests are to<br />

be saved.<br />

Tests<br />

selected<br />

for<br />

execution<br />

Failed tests<br />

end up<br />

here.<br />

Doc. no. Lang. Rev. ind. Page<br />

8


4.2 Detailed description<br />

4.2.1 Run Section<br />

• Reload: Unloads and loads the list of available test cases.<br />

• Add: Add test to execution list.<br />

• Clear: Clears execution list.<br />

• Run All Once: Runs all tests in execution list one time from top to bottom.<br />

• Run All, Loop Last: Runs all tests in execution list one time from top to bottom until last test which<br />

it repeats infinitely.<br />

4.2.2 Execution Section<br />

• Stop: Stops execution of tests. Will stop after current test has finished executing.<br />

• Debug windows: The left window displays debug information about the tests if something has<br />

failed.<br />

The right window displays failed tests, if there are any.<br />

4.2.3 Settings Section<br />

• Controller: IP address to Controller which will press the screen.<br />

• This Computer. IP address to the computer running the program.<br />

• Windows: test folder defines the path to the test folder.<br />

• Execution: Seconds to wait between actions defines extra time to wait after a test has been<br />

completed.<br />

4.2.4 Tips and Tricks<br />

If regular tests are performed, just select the tests you want to run and click ‘Run All Once’-button. Then<br />

watch the execution section to see if any tests failed or not.<br />

If you want to stress the system in any way, i.e. look for memory leakage, it sometimes can be useful to<br />

use the ‘Run All, Loop Last’-button. The first test can be to open a specific view or put the system in a<br />

specific state before the last test loops over and over again.<br />

You can display the FP memory by typing: fpcmd “-memShow” in a console window. Typing fpcmd “memShow<br />

–h” displays possible switches in the nclog (see section 3.2) window.<br />

To follow this information over time you can spawn a task on the controller that repeats this command.<br />

To do this type: period 1,fpcmd,”-memShow”. 1 is the time interval in seconds, fpcmd is the function<br />

followed by the parameter “-memShow”.<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Doc. no. Lang. Rev. ind. Page<br />

9


REVISION<br />

Rev.<br />

ind.<br />

Page (P)<br />

Chapt.(C)<br />

Description Date<br />

Dept./Init.<br />

W 0.1 Initial version 2007-05-<br />

04/olkje<br />

ABB Automation Technology Products<br />

BAU Robotics<br />

Doc. no. Lang. Rev. ind. Page<br />

10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!