Oil pumps<br />

Oil pumps – <strong>Danfoss</strong> RS<br />

<strong>Danfoss</strong> oil pumps - older series ➨ Replacement <strong>Danfoss</strong> types<br />

Type Code no.<br />

1/2pipe<br />

RS 60 070-3312 2 ➨ RSA 60 070-3362<br />

RS 60 070L3312 2 ➨ RSA 60 070L3362<br />

Oil pumps – <strong>Danfoss</strong> RSL<br />

➨ Type Code no. Comments/accessories<br />

<strong>Danfoss</strong> oil pumps - older series ➨ Replacement <strong>Danfoss</strong> types<br />

Type Code no.<br />

1/2pipe<br />

➨ Type Code no. Comments/accessories<br />

RSL 028 070-4330 1 ➨ BFP 21 R3 071N01571) RSL 028 070L4330 1 ➨ BFP 21 L3 071N01566) + cable, L = 710 mm: 071G0204<br />

RSL 028 070-4332 2 ➨ BFP 21 R3 1) 7)<br />

071N0157<br />

RSL 028 070L4332 2 ➨ BFP 21 L3 6) 7)<br />

071N0156<br />

RSL 028 070-4340 1 ➨ BFP 21 R3 071N01571) RSL 028 070L4340 1 ➨ BFP 21 L3 071N01566) + cable, L = 710 mm: 071G0204<br />

RSL 028 070-4342 2 ➨ BFP 21 R3 071N01571) 7) + bush ∅54: 071B0011<br />

RSL 028 070L4342 2 ➨ BFP 21 L3 6) 7)<br />

071N0156<br />

RSL 050 070-3130 1 ➨ BFP 21 R5 071N01732) RSL 050 070L3130 1 ➨ BFP 21 L5 071N0172<br />

+ cable, L = 710 mm: 071G0204<br />

2)<br />

RSL 050 070-3132 2 ➨ BFP 21 R5 071N01732) RSL 050 070L3132 2 ➨ BFP 21 L5 071N01722) RSL 050 070-3140 1 ➨ BFP 21 R5 071N01732) + cable, L = 710 mm: 071G0204<br />

RSL 050 070L3140 1 ➨ RFP 21 L5 071N01722) + bush ∅54: 071B0011<br />

1) The solenoid coil must be connected in parallel with the burner motor.<br />

2) Important: These pumps are delivered for two-pipe operation. If the pumps are mounted on a one-pipe system, the changeover screw must be removed<br />

(fig. page 6) and the return port must be stopped with a metal plug.<br />

6) If the pump is wanted delivered incl. cable, bush and flange, please order 071N0132.<br />

7) This pump is for one-pipe operation. On pumps for two-pipe operation the changeover screw must be fitted.<br />

8