Thermal Insulation (459) T-Max / Polyester insulation layer faced on one side with<br />

aluminium foil<br />

Thermal Insulation (460) Phenotherm TM / Phenotherm TM phenolic foam / A<br />

composite insulation panel comprising a phenolic foam<br />

core having a density of 60 kg/m 3 bonded on both sides<br />

with embossed aluminium foil of a thickness > or = 0.05<br />

mm using PAL LA811 adhesive<br />

Thermal Insulation (471) "OPS" Rigid Insulation Ring / Split composite insulation ring<br />

comprising rigid fire retarded polyurethane, laminated with<br />

0.3 mm thick double-sided aluminium foil as vapour barrier<br />

and protected by 0.8 mm thick galvanized iron sheet jacket<br />

Thermal Insulation (472) "UniFiber R " Fiberglass with Black Glass Tissue (BGT)<br />

Facing / Fiberglass faced on one side with black glass<br />

tissue / 25 mm / 32 Kg/m 3<br />

Thermal Insulation (474) Pilon "Thermobreak" Thermal Insulation / A closed cell<br />

polyethylene foam insulation material with a reference<br />

colour of (black) charcoal grey, in roll or sheet form.<br />

Reinforced with aluminium foil facing on one side and G60<br />

acrylic PAS adhesive backing.<br />

Acoustic insulation (476) "Pyrotek" Wavebar Quadzero Noise Barrier/A 4mm thick<br />

black flexible aluminium foil faced polymer backed by a<br />

white nonwoven polyester fabric/8.14kg/m 2 /for external<br />

acoustic insulation of duckwork<br />

Thermal Insulation (479) "Teembase" Pre-insulated Pipe System / Piping system<br />

comprising a basic carrier pipe, a metal outer jacket of<br />

minimum 0.6 mm thick stainless steel (Grade 304),<br />

galvanized steel or aluminium sheet and an insulation of 15<br />

VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />

LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />

- 75 mm thick polyurethane foam (48 kg/m 3 ) machineinjected<br />

between the carrier pipe and outer jacket.<br />

Thermal Insulation (482) "GOODEVER PF" Phenolic Foam Insulation / Phenolic<br />

foam insulation with a density of 40 kg/m 3 bonded on one<br />

side with 0.22 mm "S-series" thick doubled sided aluminum<br />

facing material using PS 8109S adhesive / thickness: 15<br />

mm - 75 mm<br />

Hueintek Inc., S. Korea 27/8/2010 August 2013 No assessment was made on the<br />

density and toxicity of smoke<br />

generated by the material under fire<br />

condition..<br />

Dongguan Juwun Rubber & Plastic<br />

Products Co., Ltd., PRC<br />

27/8/2010 August 2015 No assessment was made on the<br />

density and toxicity of smoke<br />

generated by the material under fire<br />

condition..<br />

Oxprime (International) Ltd., PRC 11/10/2010 October 2013 no assessment was made on the<br />

density and toxicity of smoke<br />

generated by the material under fire<br />

UniFiber Manufacturing Ltd., PRC 18/10/2010 October 2013 no assessment was made on the<br />

density and toxicity of smoke<br />

generated by the material under fire<br />

condition.<br />

Sekisui Pilon Pty. Ltd., Australia 10/11/2010 September 2013 Test of the material for smoke<br />

generation according to ISO 5659-2<br />

(1994) under fire condition was carried<br />

out by SP Swedish National Testing<br />

and Research Institute with test report<br />

referance P200245 dated 13.2.2002<br />

as a reference.<br />

Pyrotek Pty. Ltd., Australia 6/12/2010 December 2013 no assessment was made on the<br />

density and toxicity of smoke<br />

generated by the material under fire<br />

condition.<br />

Teembase Development Limited,<br />

PRC<br />

Shenzhen Goodever Xinxing<br />

Building Material Co., Ltd., PRC<br />

14/12/2010 December 2013 a) No assessment was made on the<br />

density and toxicity of smoke<br />

generated by the assembly under fire.<br />

b) A valid assessment report on the<br />

wall penetration seal shall be<br />

maintained.<br />

23/12/2010 September 2015 no assessment was made on the<br />

density and toxicity of smoke<br />

generated by the material under fire.<br />

page30/40