TYPE<br />
(1) <strong>Air</strong> <strong>Filters</strong><br />
BRAND NAME / MODELS / DESCRIPTION MANUFACTURER ACCEPTANCE<br />
DATE<br />
DATE TO REVIEW Remarks<br />
Carbon Filter CHEMOX and Activated Carbon filter media Sparks Technology, Inc., USA 20/9/2003 September 2013<br />
<strong>Air</strong> Filter(206) " Purolator" <strong>Air</strong> Filter Unit<br />
Throw away, dry type :<br />
a) SERVA-cell; b) hi-E 40; c) Mark 7<br />
Replaceable media type: a) SERVA-pak<br />
<strong>Air</strong> Filter(208) "FLECO" <strong>Air</strong> Filter Units Model:<br />
a) Pleated Filter<br />
b) Pocket Filter<br />
c) Septara<br />
<strong>Air</strong> Filter(260) "Camfil Farr" <strong>Air</strong> Filter - Throw away, dry type Model:<br />
a) Aeropleat IV;<br />
b) Aeropleat IV+;<br />
c) Aeropleat III;<br />
<strong>Air</strong> Filter(262) "Purafil" Chemical <strong>Air</strong> Filter - Dry type filter media: a)<br />
Chemisorbant media; b) Select CP Blend media; c) Select<br />
media; d) CP Blend media; e) SP media; f) SP Blend<br />
media; g) Triple Blend media; h) Puracarb media & i)<br />
Purakol II media. Item (a) to (i) above are to be factoryfilled<br />
into the following models: a) PK-18; b) CK-12/24 & c)<br />
PM-18 Dry air filter unit- Purafilter<br />
<strong>Air</strong> Filter(276) "CLEANCEL" <strong>Air</strong> <strong>Filters</strong><br />
Model : "MCC-7524", "MCC-7536" and "MCC-7548"<br />
a) "CLEANCEL" mini pleat HEPA filter, max. 3-1/8 in.<br />
depth.<br />
<strong>Air</strong> Filter (290) "Dust Free" Throw Away Type <strong>Air</strong> Filter<br />
a) Bag Filter: DFSB-65, DFSB-85 & DFSB-95<br />
b) Cartridge Filter: DFC-65, DFC-85 & DFC-95<br />
<strong>Air</strong> Filter (289) "Glasfloss" Throw Away Type <strong>Air</strong> Filter<br />
a) "Z-line" Series "SB", "ZL","HV","MR8","MR11" and<br />
Carbotron", max. thickness 8 in.<br />
b) "Excel", "Purapack", max. dep<br />
<strong>Air</strong> Filter (315) AAF "Am<strong>Air</strong> C" <strong>Air</strong> <strong>Filters</strong>, Model: "Am<strong>Air</strong> C" throw-away<br />
dry type panel filter<br />
<strong>Air</strong> Filter (320) "Visko-<strong>Air</strong>e" Polyester Filter Media,<br />
Model :<br />
a) Dry Type Media, Roll Media, Untreated<br />
b) Adhesive Coated Media, Roll Media, Tackified<br />
c) Dry Type Media, R-70 Media<br />
d) Dry Type Media, R-80 Media<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Purolator Products <strong>Air</strong> Filtration Co.<br />
USA<br />
Kunshan Fleco Filtration Co. Ltd.,<br />
P.R.C.<br />
Camfil Farr Group, Malaysia and<br />
PRC<br />
11/5/2007 May 2012 UL File No. AJZV.R4138<br />
Test Standard: UL 900<br />
30/5/2007 May 2012<br />
14/3/2008 March 2012<br />
Purafil Inc., USA 17/3/2008 March 2012 The filter media and filter modules<br />
shall both be UL listed and bear the<br />
suitable UL Marking as appropriate.<br />
Clean Tech Korea Co. Ltd., S.<br />
Korea<br />
Shen Zhen Dust Free Mfg. Limited,<br />
PRC<br />
19/5/2008 May 2013<br />
3/7/2008 July 2013 Class 1 or 2, as listed in UL 900<br />
Certificates.<br />
Glassfloss industries Inc., USA 3/7/2008 July 2013 Class 1 or 2, as listed in UL 900<br />
Certificates.<br />
AAF International, Louisville, USA 19/9/2008 Sept 2013 The filte shall remain UL listed and<br />
bear the appropriate UL mark<br />
Viskon-<strong>Air</strong>e Corporatio, USA 14/10/2008 Oct 2013 The filter shall be UL listed and bear<br />
the appropriate UL marking.<br />
page1/40
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
<strong>Air</strong> Filter (328) "Wendell" Filter Fabric<br />
Model: Washable dry type media, 0.125" thick<br />
a) AM5491-21<br />
b) NZ4981-21<br />
Wendell Fabrics Corp., USA 31/10/2008 Oct 2013<br />
<strong>Air</strong> Filter (331) "AAF"5700 Disposable Panel Type <strong>Air</strong> Filter<br />
Model: 5700 Disposable Panel Type, 1" and 2" thick<br />
AAF International, Louisville, USA 17/11/2008 November 2013<br />
<strong>Air</strong> Filter (332) "AAF" Frontline <strong>Air</strong> Filter<br />
Throw-away dry-type or adhesive coated pads or rolls, max.<br />
2.0" thick<br />
a) Frontline Gold<br />
b) Frontline Blue, Type S and Type FG<br />
c) Frontline Green, Type S and FG<br />
AAF International, Louisville, USA 15/12/2008 December 2013<br />
<strong>Air</strong> Filter Media (339) "Viskon"<br />
Model: AJZV.R4937<br />
"Drico BGD" throw-away, adhesive coated fiber glass air<br />
filter pads and roll media, max<br />
<strong>Air</strong> Filter (340) Camfil Farr / Megalam Panel Filter - Throw-away, dry type<br />
air filter units/ Maximum 10 in depth, AJZV.R14563<br />
Frontline <strong>Air</strong> Filter (341) Goldmine / Dry-type, throw-away air filter unit<br />
a) "Pleated Panel Series", maximum depth 4 in.<br />
b) "Multi-Pocket Series", maximum depth 24 in. /<br />
AJZV.R26138<br />
<strong>Air</strong> Filter Units (342) AAF / Throw-away, dry type air filter units:<br />
a) "Biocel", max. 12 in. thick<br />
b) "Astrocel I HCX", max. depth 111/2 in.<br />
c) "Am<strong>Air</strong> 200E", 2 & 4 in. thick<br />
<strong>Air</strong> Filter Pads (363) Clarcor "Streamline - P, D1 and AM" Series <strong>Air</strong> Filter Pads /<br />
Throw away, dry type:<br />
a) Streamline - P, b) Streamline - DL, c) Streamline - AM<br />
/ Thickness : Max. 2 inches<br />
<strong>Air</strong> Filter Units (365) Purolator / Throw away, dry type : Defiant Mark 80-D /<br />
Thickness ; As listed in UL Certifications Directory<br />
AJZV.R4138<br />
<strong>Air</strong> Filter Units (370) Flanders-Precisionaire / Throw away, dry type<br />
a) Pre Pleat 40, b) Pre Pleat 62R, c) Alpha Cell, d)<br />
Precision Cell, e) Alpha Panel and Throw away, bag type<br />
f) Precision Pak<br />
<strong>Air</strong> Filter (389) Camfil Farr / Throw-away, dry type filter units AP-Eleven<br />
and AP-Thirteen / 1, 2 and 4 in, AJZV.R2872<br />
<strong>Air</strong> Filter Unit (390) JCL / CF-250 / Dry type cylindrical shaped filter unit (150<br />
mm dia., 250 mm long) comprising a Grade 304 stainless<br />
steel frame and mesh filled with zeolite (2 kg) as the<br />
filtering medium<br />
Viskon-<strong>Air</strong>e Corporatio, USA 2/1/2009 January 2014 the filter shall be UL listed and bear<br />
the appropriate UL marking.<br />
Camfil Farr Group, Malaysia, PRC<br />
and USA<br />
Goldmine Company Ltd., Hong<br />
Kong<br />
23/1/2009 January 2014 the units shall be UL listed and bear<br />
the appropriate UL Marking<br />
23/1/2009 January 2014 the filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings<br />
AAF International, USA 29/1/2009 January 2014 the filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings<br />
Clarcor <strong>Air</strong> Filtration Products, USA 29/4/2009 April 2014 the units shall be UL listed and bear<br />
the appropriate UL Marking<br />
Purolator Products <strong>Air</strong> Filtration Co.<br />
USA<br />
4/5/2009 May 2014 the units shall be UL listed and bear<br />
the appropriate UL Marking<br />
Flanders-Precisionaire Inc., USA 9/6/2009 June 2014 the units shall be UL listed and bear<br />
the appropriate identification Marking<br />
Camfill Farr Group, Malaysia and<br />
PRC<br />
4/8/2009 August 2014 The unit shall be UL listed and bear<br />
the appropriate UL Marking.<br />
JCL Engineering Ltd., Hong Kong 12/8/2009 August 2012 The filter unit shall bear an appropriate<br />
product label.<br />
page2/40
<strong>Air</strong> Filter (391) Goldmine / Dry-type, throw-away air filter unit<br />
a) "Separator Gold Series", maximum depth 12 in.<br />
Dry-type, throw-away air filter unit, pad and roll media<br />
b) "HD Synthetic Media Series", maximum depth 2 in.<br />
/ AJZV.R26138<br />
<strong>Air</strong> filter units (407) FLECO / a) Separator HEPA Filter - maximum 12 in. depth<br />
b) Pleated Filter - maximum 5 in. depth c) Mini-Pleated<br />
Panel - maximum 2.75 in. depth / UL File No. :<br />
AJZV.R22353 and Test Standard : UL 900 - Determination<br />
of the combustibility and the amount of smoke generated<br />
for air filter units and Test Result : Class 2 as listed in the<br />
UL certificates<br />
Photocatalysis Autibacterial<br />
Metal Foam Filter (413)<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Goldmine Company Ltd., Hong<br />
Kong<br />
Kunshan Fleco Filtration Co. Ltd.,<br />
P.R.C.<br />
APOGEE / ZA002 / A 50 mm thick spongy looking Shunde Canafull Industry Co. Ltd.,<br />
washable foam metal filter media having a void ratio of over<br />
95%<br />
China<br />
<strong>Air</strong> Filter Units (418) Flanders-Precisionaire / Dry type, pleated HEPA filter units<br />
up to 12 in. depth*:<br />
a) Alpha 95, b) Alpha Cell, c) Alpha 2000, d) Alpha HT, e)<br />
Dimple Pleat<br />
<strong>Air</strong> Filter (419) Hencolin (Taiwan) / Dry-type, throw-away air filter unit,<br />
a) "Extended Surface Filter" maximun depth 4 in.<br />
b) "Synthetic Bag Filter", maximun depth 36 in. / UL 900 -<br />
Determination of the combustibility and the amount of<br />
smoke generated for air filter units<br />
2/9/2009 September 2014 the filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings<br />
15/1/2010 January 2014 This units shall be UL listed and bear<br />
the appropriate UL Marking<br />
4/3/2010 March 2012 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
Flanders-Precisionaire Inc., USA 15/4/2010 April 2015 The units shall be UL listed and bear<br />
the appropriate identification markings<br />
Hencolin International Corporation,<br />
Taiwan<br />
<strong>Air</strong> Filter (420) Camfil Farr / a) C-Flo, b) Superpac / Camfil Farr Group, Malaysia and<br />
PRC<br />
<strong>Air</strong> Filter (421) Camfil Farr / a) Opakfil, b) <strong>Air</strong>opac, & c) <strong>Air</strong>opac Green / Camfil Farr Group, Malaysia and<br />
PRC<br />
<strong>Air</strong> Filter (422) Camfil Farr / a) Ecopleat Green, b) TCPA together with<br />
RFM housing /<br />
Camfil Farr Group, Malaysia and<br />
PRC<br />
<strong>Air</strong> Filter (423) Camfil Farr / a) C-Pleat - 1", 2" & 4", b) CFP-KW - 46 mm / Camfil Farr Group, Malaysia and<br />
PRC<br />
<strong>Air</strong> Filter (436) Hencolin (Taiwan) / Dry-type, throw-away air filter unit,<br />
a) "HEPA Separator Filter" maximun depth 12 in.<br />
b) "ASHRAE Separator Filter", maximun depth 12 in. / UL<br />
900 - Determination of the combustibility and the amount of<br />
smoke generated for air filter units<br />
Hencolin International Corporation,<br />
Taiwan<br />
20/4/2010 April 2015 The filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings.<br />
This letter supersedes our previous<br />
one of the same series dated<br />
1.12.2009 on the same products.<br />
26/4/2010 April 2015 Nil<br />
26/4/2010 April 2015 Nil<br />
26/4/2010 April 2015 Nil<br />
26/4/2010 April 2015 Nil<br />
4/6/2010 June 2015 The filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings<br />
page3/40
<strong>Air</strong> Filter (451) AAF / Dry type air filter units for filling with SAAF Carb and<br />
SAAF Oxidant filter media: a) SAAF Medium Duty<br />
Cassette b) SAAF Heavy Duty Cassette c) SAAF<br />
Commercial Grade Cassette: Replaceable filter medium<br />
a) SAAF Carb b) SAAF Oxidant c) SAAF Carb MA d)<br />
SAAF Carb MB e) SAAF Carb MC f) SAAF Carb MA-HT<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
<strong>Air</strong> Filter (453) Nitta / Throw-away dry-type air filter units designated as a) Taiwan Nitta Filter Co., Ltd.,<br />
33XX-XX, 34XX-XX, 35XX-XX, 36XX-XX, 38XX-XX, 39XX-<br />
XX, maximum depth 4 3/4 in. B) 15XX-XX, maximum depth<br />
11 3/4 in. ("XX-XX" denotes efficiency and frame<br />
dimensions)<br />
Taiwan<br />
<strong>Air</strong> Filter (455) Goldmine / a) Dry-type, throw-away air filter unit,<br />
"Separator Gold Series", maximum depth 12 in. B) Drytype,<br />
throw-away air filter unit, pad and roll media, "HD<br />
Synthetic Media Series", maximum depth 2 in.<br />
<strong>Air</strong> Filter (462) <strong>Air</strong>guard / Throw-away, dry type filter units (from Malaysia)<br />
a) "Clean Pak" Series - CP5, CP6, CP8 and CP9; max.<br />
depth 36 in. b) "VSC" Series; max. depth 14 in.<br />
Replaceable media, adhesive coated air filter pads or rolls<br />
(from USA) c) "AGFG"<br />
Filter (468) "AAF" AmerTex R-Series Filter / AmerTex R15, R29 and<br />
R50 Series<br />
<strong>Air</strong> Filter (469) Dust Free "Dust Fighter 95" / Washable dry type air filter<br />
unit Dust Fighter 95, thickness 1" and 2"<br />
<strong>Air</strong> Filter (493) Purafil "Purafilter" <strong>Air</strong> Filter / Purafilter / <strong>Air</strong> filter with either<br />
paperboard or metal frame and factory-filled with SPB-<br />
500/30 filter medium Dimension 24" x 24" with thicknesses<br />
of 2", 4" or 12"<br />
<strong>Air</strong> Filter (498) Filtration Group "Auto Roll Filter" <strong>Air</strong> Filter / Auto Roll Filter -<br />
adhesive coated, throw away type / Maximum 2 in. depth<br />
<strong>Air</strong> Filter (510) "Hencolin" (Taiwan) <strong>Air</strong> Filter / Dry-type, throw-away air<br />
filter unit "HEPA Mini-Pleat Filter", maximum depth 3 in. /<br />
UL File Number AJZV.R26150<br />
AAF International, Louisville, USA 28/7/2010 July 2015 The filter units and medium shall be<br />
UL listed and bear the appropriate UL<br />
mark.<br />
Goldmine Company Ltd., Hong<br />
Kong<br />
Clarcor <strong>Air</strong> Filtration Products Inc.,<br />
USA and Malaysia<br />
AAF International, Louisville, USA 28/9/2010 September 2015<br />
28/7/2010 July 2015 The filters shall remain UL listed and<br />
bear the appropriate identifications<br />
markings<br />
2/9/2009 September 2014 The filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings.<br />
2/9/2010 September 2015 the units shall be UL listed and bear<br />
the appropriate UL Marking<br />
Dust Free Inc., Royse City, USA 28/9/2010 September 2015 The units shall be UL listed and bear<br />
the appropriate identification markings<br />
Purafil Inc., USA 1/2/2011 February 2016 The filter is to be marked with the<br />
manufacturer's name, country of<br />
origin, model name and the standard<br />
to which it has been tested.<br />
Filtration Group Inc., USA 24/2/2011 February 2016 a) The filter shall remain UL listed. b)<br />
Suitable documentation, e.g. delivery<br />
order, detailing the following should be<br />
kept by users of this filter for<br />
inspection upon request: i)<br />
Manufacturer's name; ii) Place of<br />
manufacture; iii) Model number; and<br />
iv) The standard to which the filter has<br />
been type-tested.<br />
Hencolin International Corporation,<br />
Taiwan<br />
12/4/2011 April 2016 The filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings.<br />
page4/40
<strong>Air</strong> Filter Units (512) Purolator "Key Pleat" <strong>Air</strong> Filter Units / Throw away, dry type<br />
air filter unit "Key Pleat" / Thickness : As listed in UL<br />
Certifications Directory AJZV.R5891<br />
<strong>Air</strong> Filter (535) "Welaire" AC Series <strong>Air</strong> Filter / AC Series / TiO2 filter wwith<br />
aluminium frame utilizing photocatalyst material a) UP-102<br />
(A 2 mm thick nickel three dimensional structure alloy<br />
material) or b) UP-315 (A 13 mm thick aluminium<br />
honeycomb structure material)<br />
<strong>Air</strong> Filter (537) "AAF" <strong>Air</strong> Filter Units / Throw-away, dry type: a) Am<strong>Air</strong> 100,<br />
Am<strong>Air</strong> 200, Am<strong>Air</strong> 300 and Am<strong>Air</strong> 500 b) VariCel, Varicel II<br />
c) AstroCel I, AstroCel II, AstroCel TM Electrically operated<br />
roll-away type: d) Roll-O-matic Throw-away, dry type,<br />
automatic roll filter media: e) Roll-O-Mat Throw-away,<br />
extended area, dry type: f) DriPak 2000<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Clarcor <strong>Air</strong> Filtration Products Inc.,<br />
USA<br />
Zhongshan Saiver Welaire <strong>Air</strong>conditioning<br />
Equipment Co., Ltd.,<br />
PRC<br />
12/4/2011 April 2016 The units shall be UL listed and bear<br />
the appropriate UL Marking.<br />
2/8/2011 August 2016<br />
AAF International, Louisville, USA 10/8/2011 August 2016 The filters shall remain UL listed and<br />
bear the appropriate idenification<br />
markings.<br />
<strong>Air</strong> Filter (538) Camfil Farr "C-Flo" <strong>Air</strong> Filter Unit / "C-Flo" Camfil Farr Group, PRC 11/8/2011 August 2016 This letter supersedes our assessment<br />
made on the same filter model given<br />
under our letter of the same series<br />
dated 26.4.2010.<br />
<strong>Air</strong> Filter (540) "AAF" <strong>Air</strong> Filter Units / Throw-away, dry type: a) Am<strong>Air</strong><br />
1100 (max. depth 4 3/8 in.) b) Am<strong>Air</strong> 1300 (max. depth 4<br />
in.)<br />
<strong>Air</strong> Filter Units (549) "AAF" <strong>Air</strong> Filter Units / Throw-away dry type, maximum<br />
depth 12 in. a)VariCel V-70. -80, -95in.) b) VariCel V<br />
MER15<br />
<strong>Air</strong> Filter (582) "Camfil Farr" <strong>Air</strong> <strong>Filters</strong> / Throw away, dry-type: a)<br />
Aeropleat IV b) Aeropleat IV+ c) Aeropleat III d) Type 30/30<br />
e) Riga-Flo<br />
<strong>Air</strong> Filter (583) "Purafil" Chemical <strong>Air</strong> <strong>Filters</strong> / Dry-type replaceable filter<br />
media: a) Chemisorbant media b) Select CP Blend media<br />
c) Select media d) Select Chemisorbant media e) SP media<br />
f) SP Blend media g) Triple Blend media h) Puracarb media<br />
i) Purakol II media j) Puracarb AM media<br />
<strong>Air</strong> Filter(585) "Permatron" <strong>Air</strong> Filter - Waqshable unit, dry type:<br />
a) DustEater Easy Flow;<br />
b) Lifestyle Plus MF and Lifestyle Plus LR<br />
<strong>Air</strong> Filter(586) "AIRCLEAN / CH1093" Medium Efficiency Filter Cotton /<br />
"AIRCLEAN / CH1093" polyester fibre of thickness 18mm<br />
and density of 350g/m 2 / Filter frame: Aluminium<br />
AAF International, Louisville, USA 15/8/2011 August 2016 The filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings.<br />
AAF International, Louisville, USA 21/9/2011 September 2016 The filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings.<br />
Camfil Farr Group, Malaysia and<br />
PRC<br />
6/6/2012 June 2017 The filter units shall remain UL listed<br />
and bear the appropriate UL marking.<br />
Purafil Inc., USA 7/6/2012 June 2017 The filter media and filter modules<br />
shall both remain UL listed and bear<br />
the appropriate UL marking.<br />
Permatron Corp., USA 21/6/2012 June 2017 The Units shall be UL listed and bear<br />
the appropriate UL marking.<br />
Chan's Industrial Company, PRC 19/6/2012 June 2015 a) Filter frames/retainers not testes<br />
and shall be of full metallic<br />
construction. b) All filter cells shall be<br />
marked with the information required<br />
in Clause 6.5.1, Part VI of FSD<br />
Circular Letter No. 4/96.<br />
page5/40
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
<strong>Air</strong> Filter(614) "Phototroph" Photocatalytic Extruded Ceramic Filter /<br />
PECF200<br />
Zeta Coating Hong Kong Ltd., PRC 12/11/2012 November 2017<br />
<strong>Air</strong> Filter(615) "Camfil Farr" <strong>Air</strong> <strong>Filters</strong> / Filter Model: --Throw away, dry<br />
type a) Absolute --Replacable media, adhesive coated a)<br />
Hi-Cap --Replacable media, dry type a) Hi-Flo / Thickness:<br />
As listed in UL Certification Directory<br />
Camfil Farr Group, Malaysia and<br />
PRC<br />
23/11/2012 November 2017 The units shall be UL listed and bear<br />
the appropriate UL Marking.<br />
<strong>Air</strong> Filter(618) "Permatron" <strong>Air</strong> Filter / "Dust Eater" electrostatic filter Permatron Corp., USA 11/12/2012 December 2017 The filter unit shall be UL listed and<br />
bear the appropriate UL Marking.<br />
<strong>Air</strong> Filter(620) :NCCO" Nano <strong>Air</strong> Filter Unit / NF 1001 /Dry type panel filter<br />
unit (300 mm - 600mm(L) x 300 - 600 mm (W) x 20 - 36<br />
mm (Th.)) comprising a galvanized steel frame filled with<br />
"nano" material (zeolite) as the filtering medium<br />
<strong>Air</strong> Filter(622) "Camfil Farr" Fiberglass <strong>Air</strong> Filter Unit / "Camfil Farr"<br />
Fiberglass Filter<br />
<strong>Air</strong> Filter(627) "AAF" <strong>Air</strong> Filter Units / Throw-away dry type, maximum<br />
depth 12 in. a)VariCel V-70. -80, -95in.) b) VariCel III<br />
(2) <strong>Air</strong> Handling Equipment<br />
<strong>Air</strong> Handling Equipment ZEMAC - Sound Attenuator used in Combined Ventilation<br />
and Smoke Extraction System<br />
RHT Limited, Hong Kong 18/12/2012 December 2017 The filter unit shall bear an appropriate<br />
product label<br />
Camfil Farr Group, PRC or<br />
Malaysia<br />
21/12/2012 December 2017<br />
AAF International, Louisville, USA 3/1/2013 January 2018 The filters shall remain UL listed and<br />
bear the appropriate identification<br />
markings.<br />
ZEMAC Engineering Co. Ltd.,<br />
Hong Kong (Formly known as<br />
CEMAC Engineering Co. Ltd.,)<br />
26/3/2003 January 2012<br />
page6/40
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Variable <strong>Air</strong> Volume Box (367) "RSVAV" / Series TU, Series FP, Series UF /<br />
Royal Service <strong>Air</strong> Conditioning<br />
13/5/2009 May 2014<br />
1) Series TU - The basic unit casing is of galvanized steel<br />
sheet construction internally lined with fibreglass /<br />
elastomeric insulation. All control devices and components<br />
are enclosed in a galvanized steel enclosure external to the<br />
air stream.,<br />
2) Series FP - The basic unit casing is of galvanized steel<br />
sheet construction internally lined with fibreglass /<br />
elastomeric insulation. The unit incorporates a fan-motor<br />
assembly comprising a galvanized steel fan wheel and<br />
housing and a totally enclosed single phase motor. All<br />
control devices and components are enclosed in a<br />
galvanized steel enclosure external to the air stream,<br />
3) Series UF - The basic unit casing is of steel construction<br />
internally lined with elastomeric insulation. All control<br />
devices and components are enclosed in a galvanized steel<br />
enclosure shielded from the air stream. <strong>Air</strong> grille fitted to the<br />
unit is of extruded aluminium. For fan-powered units, it<br />
incorporates a fan-motor assembly comprising a galvanized<br />
steel fan wheel and housing and a totally enclosed aingle<br />
phase motor.<br />
(Guangdong) Corp., PRC<br />
Variable Volume Box (490) TROX "TVB" Variable Volume Box / Series TVB / All<br />
metallic construction with galvanized steel sheet casing<br />
which is lined internally with 25 mm thick glass wool<br />
insulation. All control devices and components are housed<br />
in a galvanized steel enclosure and shielded from the air<br />
stream. Insulation material is glass wool insulation board,<br />
("Polyglass polywool Ductliner", Malaysia) of density 32<br />
Kg/m 3 and is in compliance with BS 476 Part 6: 1989<br />
(Overall Performance I ≦ 12, Sub-index i 1 ≦ 6) and BS<br />
476 Part 7: 1997(Class 1) All non-metallic components are<br />
in compliance V0 or V2 flammability class when tested to<br />
UL 94 and UL listed.<br />
Variable <strong>Air</strong> Volume Box (545) "SUN" Variable <strong>Air</strong> Volume Box / Series VAV-5000 and<br />
Series VAV-50E1<br />
TROX Malaysia Sdn. Bhd.,<br />
Malaysia<br />
SUNRISE <strong>Air</strong>-conditioning<br />
Equipment Ltd., PRC<br />
27/1/2011 January 2016<br />
7/9/2011 September 2016<br />
page7/40
<strong>Air</strong> Handling Equipment (613) "VibrAcoustics® RLC" Rectangular Sound Attenuator /<br />
Construction: The casing and splitter nose are constructed<br />
from 0.8mm to 1.2mm thick galvanized steel sheet. The<br />
splitter body is fabricated from 0.55mm to 0.8mm thick<br />
galvanized perforated steel sheet with "Thermawool KT/CT<br />
32 Glasswool" or "Thermawool KT/CT 48 Glasswool" Fibre<br />
Glasswool of density 32 or 48kg/m 3 packed as the infill<br />
material.<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Zhongshan Sanbe Metal Acoustics<br />
Limited, PRC<br />
(3) Smoke Control Componects ( Ventilator / Fire Rated Duct/ Smoke Curtain )<br />
Fire Rated Duct Prefabricated "Durasteel 3DF2" panel comprising a<br />
cementitious core with perforated galvanized steel facing<br />
on both side<br />
Fire Rated Duct Rectangular duct fabricated from a single layer of 9.5mm<br />
thick "Durasteel 3DF2" panel comprising a cementitious<br />
core with perforated galvanized steel, 0.5mm thick, facing<br />
on both side (Horizontal duct system only)<br />
Intumex Asia pacific Pte. Ltd. 18/1/2008 January 2013<br />
Intumex Asia pacific Pte. Ltd., U.K. 20/3/2008 October 2012<br />
Smoke Curtain (271) Gelec "GIKI" automatic smoke curtains BLE Smoke and Fire Curtains Ltd.,<br />
UK<br />
15/4/2008 April 2012<br />
Actuator (284) "Simon RWA EA-KL800/600" Simon RWA GmbH, Germany 17/6/2008 June 2012<br />
Fire Rated Duct (334) "Promatect-S" 6mm Fire Resistant Board for the Cladding<br />
of Steel Ventilation and Smoke Extraction Ductwork<br />
Fire Rated Duct (336) "Flamebar B.W. II" Fire Duct and Fire Enclosure System<br />
A steel duct system of proprietary design and construction,<br />
with a spray of "Flammebar B.W.11" fire proofing for fire<br />
protection and "Rockwool" mineral wool for thermal<br />
insulation.<br />
Promat International (Asia Pacific)<br />
Ltd.<br />
Fire Spray International Ltd. 16/12/2008 April 2013<br />
31/10/2012 November 2017 a) Other glasswool infill materials of<br />
the attenuator other than those tested<br />
as specified above and all<br />
seals/gaskets (if any) shall conform to<br />
the requirements for internal insulation<br />
stipulated in Part XI of the FSD<br />
Circular Letter No. 4/96. b) No<br />
assessment was made on the density<br />
and toxicity of smoke generated by the<br />
glasswool infill material under fire.<br />
12/12/2008 February 2012 The system only meets the minimum<br />
requirement of 30 min insulation for<br />
smoke extraction system and is not<br />
suitable for use in situation where<br />
higher insulation criteria are specified.<br />
page8/40
Fire Rated Duct (392) Promatect-H 15 mm / A galvanized steel sheet ducting<br />
system, protected by "Promatect-H" boards of 15 mm thick<br />
and stone mineral wool of thickness 50 mm and density<br />
100 kg/m 3 , as detailed in the assessment report. The steel<br />
duct mustb be constructed in accordance with the<br />
requirements of DW/144 "Specification for sheet metal<br />
ductwork: low, medium and high pressure/velocity air<br />
systems" with Pittsburgh lock longitudinal seams and steel<br />
angle cross joints. Maxium Duct size: 6,000 mm (W) x<br />
2,500 mm (H) Internal<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Promat International (Asia Pacific)<br />
Ltd.<br />
Fire Rated Duct (429) Promatect-S 9.5 mm / 10 m (W) x 4.0m (H) / A ducting Promat International (Asia Pacific)<br />
system comprising "Promatect-S 9.5 mm thick steel faced<br />
fibre reinforced cement boards fixed on a framework of 50 x<br />
50 x 3 mm thick steel channels with a dedicated hanger<br />
support systems<br />
Ltd.<br />
Static Smoke Ventilators (405) "Ventibay" & "Ventilight" / EC Certificate of Conformity No.:<br />
336-CPD-10430<br />
Static Smoke Ventilators (406) "Certilam" & "Certilux" / sizes as indicated in the annex to<br />
EC Certificate of Conformity No.: 336-CPD-6742-1 dated<br />
17.7.2007 issued by TNO Certification B.V., the<br />
Netherlands<br />
Static Smoke Ventilators (410) Exubay / Size as indicated in the annexes to EC Certificate<br />
of Conformity No.: 336-CPD-6742-3 / i) The ventilator is<br />
keep closed by an electromagnetic lock / compressed air<br />
and forced to open by a mechanical spring when the<br />
electricity / air supply is cut off; ii) The ventilator is of fail<br />
safe design. It will be opened automatically when there is<br />
failure in electricity / compressed air supply, control cable<br />
or control panel; iii) A manual switch is provided which shall<br />
be overridden by fire alarm signal<br />
Fire Rated Duct (466) "Vermiduct" System / a) The ductwork of "Vermiduct"<br />
system is constructed of galvanized steel or sheet metal to<br />
DW/144 of wall thickness not less than 0.8mm. b) The<br />
thickness of "Vermiduct" spray may vary from 12mm to<br />
65mm depending on the orientation, duct size and fire<br />
rating.<br />
2/9/2009 August 2013 The system should be designed and<br />
installed in compliance with the details<br />
of construction, penetration seals,<br />
support hangers and duct joint<br />
sealants as started in the assessment<br />
report. Installation data should be<br />
made available on request for<br />
ventilation.<br />
30/4/2010 July 2014 No assessment was made on the fire<br />
rating of the ductwork system in<br />
accordance with the insulation crterion<br />
of BS 476: Part 24 : 1987., This letter<br />
supersedes our previous one of the<br />
same series dated 11.2.2009 on the<br />
same product.<br />
Souchier, France 7/1/2010 June 2014 A valid "EC - Certificate of Conformity"<br />
shall be maintained<br />
Souchier, France 14/1/2010 January 2014 A valid "EC - Certificate of Conformity"<br />
shall be maintained<br />
Souchier, France 25/1/2010 January 2014 A valid "EC - Certificate of Conformity"<br />
shall be maintained<br />
L & A Fazzini Manufacturing Pty<br />
Ltd., Australia<br />
17/9/2010 March 2014 a) all design, fabrication and<br />
installation of the "Vermiduct" duct<br />
system shall be carried out by<br />
manufacturer approved applicators. b)<br />
Applicators must hold a valid L & A<br />
Fazzini Manufacturing Pty Ltd.<br />
Applicator License.<br />
page9/40
Static Smoke Ventilators (477) Hexadome "Hexasteel" & "Hexacoif" Static Smoke<br />
Ventilators for Natural Venting of Staircase/a) Hexasteel b)<br />
Hexacoif (As indicated in the annex to EC Certificate of<br />
Conformity No.:0333-CPD-219003)<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Fire Rated Duct (491) "WinDuct" Fire Resistant Coated Ductwork System / a) Passive Fire Protection Sdn., Bhd.,<br />
Ductwork is constructed of galvanized steel sheet in 1,200<br />
mm long section to DW/144 of thickness 1.0 mm. b) A<br />
layer of spray or brush/roller applied "Winduct" intumescent<br />
water based fire prevention coating, minimum 0.6 mm thick.<br />
Malaysia<br />
Fire Rated Duct (495) FireMaster FastWrap XL / no model / FireMaster FastWrap<br />
XL is a fully foil encapsulated Thermal Ceramics patented<br />
Superwool® fibre (an alkaline-earth silicate wool) with a<br />
nominal density of 96 kg/m 3 and thickness of either 38 mm<br />
.<br />
Smoke Ventilators (499) "Brakel" Smoke Ventilators for Static Smoke Extraction<br />
System / a) Eura and Eura-R; b) Duo Therma<br />
Automatic Smoke Curtain (533) "BLE" (UK) SD60 Automatic Smoke Curtain / SD 60 / A<br />
woven glass referenced "X32K" incorporating a<br />
polyurethane coating with aluminium pigments on both<br />
faces; the fabric has an overall weight of 455 g/m 2 and a<br />
thickness of 0.43 mm as described in report WFRC No.<br />
C131932 of 29.5.2003 by Warrington Fire Research Centre.<br />
Hexadome, France 6/12/2010 December 2015 A valid "EC-Certificate of Conformity"<br />
shall be maintained.<br />
Thermal Ceramics UK Ltd., United<br />
Kingdom<br />
1/2/2011 September 2015 a) Installation of the fire rated duct<br />
system shall be carried out by<br />
Dekkons Ltd. (who shall be holding a<br />
valid authorization issued by Passive<br />
Fire Protection Sdn., Bhd., Malaysia)<br />
or his authorized representatives. b) A<br />
letter shall be issued by Dekkons Ltd.<br />
to certify the quality of every<br />
completed "WinDuct" fire resistant<br />
coated ductwork system. c) Valid test<br />
reports and assessment reports as<br />
listed above shall be made available<br />
upon request.<br />
14/2/2011 March 2015 Nil<br />
Brakel Aluminium b.v., U.K. 24/2/2011 February 2016 A valid "EC-Certificate of Conformity"<br />
shall be maintained.<br />
BLE Smoke and Fire Curtains Ltd.,<br />
UK<br />
11/7/2011 July 2014 All test reports mentioned above shall<br />
maintain their validity through relevant<br />
review reports.<br />
page10/40
Actuator (541) "SE Controls" Window Actuator for Static Smoke Vents / a)<br />
SELA N 24R b) SEPO 50 c) SELA N 24G d) SECO N24<br />
Fire Rated Duct (621) Caswell "Firesafe" Ductwork System / A rectangular or<br />
circular steel duct system of proprietary design and<br />
construction. For thermal insulation and hard body impact<br />
test, the duct system is to be wrapped with Roxul "Firesafe"<br />
Rockwool with a 130 microns aluminum foil facing and a<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
nominal density of 160kg/m 3 .<br />
Static Smoke Ventilators (625) Souchier "Certiciel" & "Certilight" Smoke Ventilators for<br />
Static Smoke Extraction System / a) Certiciel b) Certilight<br />
(Sizes as indicated in the annex to EC Certificate of<br />
Conformity No.: 336-CPD-6742-2)<br />
(4) Fire Resistant Cables<br />
Fire Resistant Cable (180) Cavicel SPA "Firecel" SR112 AND SR114H Fire Resistant<br />
Cables<br />
SE Controls, UK 15/8/2011 August 2016 No assessment was made on the<br />
smoke vents designed for operation by<br />
the actuator models covered in this<br />
letter.<br />
New Glory Engineering Limited,<br />
PRC<br />
18/12/2012 January 2014 a) All design, fabrication and insulation<br />
of fire rated duct shaould be certified<br />
with a label stuck on every duct<br />
section by Centalink International Ltd.,<br />
who should possess a valid licence in<br />
Hong Kong issued by Firesafe Fire<br />
Ratesd Ductwork Limited. b) The fixing<br />
of drop rods into supporting structure<br />
shall be in accordance with the<br />
reference letter of WFRC<br />
135052/2/RHE dated 19.2.2004<br />
Souchier, France 2/2/2010 February 2014 A valid "EC - Certificate of Conformity"<br />
shall be maintained<br />
Cavicel SpA 7/2/2007 February 2012<br />
page11/40
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Fire Resistant Cable(182) "SEGURFOC" Fire Resistant Cables Grupo General Cables Sistemas<br />
S.A., Spain<br />
21/2/2007 June 2012<br />
Fire Resistant Cable (200) "AEI" Firetec Multi-core and Armoured Fire Resistant<br />
Cables<br />
AEI Cables Limited, Durham, UK 25/4/2007 April 2012<br />
Fire Resistant Cable(234) "AEI" Mineral Insulated Cables (light duty, single core and<br />
heavy duty)<br />
AEI Cables Limited, Durham, UK 11/10/2007 October 2012<br />
Fire Resistant Cable(247) "DUCAB BICC" DUCAB - FR Fire Resistant Cables:<br />
Conductor size 1.5 to 35mm 2 & 50 to 400mm 2 Dubai Cable Company(Private)<br />
28/11/2007 November 2012<br />
inclusive, 2.3<br />
& 4 core<br />
Ltd., U.A.E.<br />
Fire Resistant Cable(256) Cableplus "Firepro" Fire Safety Cables 1.0mm 2<br />
to 16mm 2 Cableplus (SuZhou) Technologies 15/2/2008 Feb 2013<br />
single core tested to BS6387: 1994 Cat. C, W, Z. Co.,Ltd., PRC<br />
Fire Resistant Cable(287) "Fire Force" fire resistant cables<br />
(conductor size: 1, 1.5, 2.5, 4mm 2; 2, 3& 4 core)<br />
Eland Cables Ltd., U.K. 20/6/2008 June 2013<br />
Fire Resistant Cable(304) "Fireflix" - 1.5 mm 2 , single core Caledonian Cables Ltd., U.K. 5/8/2008 August 2013<br />
Fire Resistant Cable(307) "DUCAB BICC" DUCAB - FR Fire Resistant Cables: Model:<br />
Ducab - FR SC Conductor size<br />
1.5 to 10mm 2, Dubai Cable Company(Private)<br />
12/8/2008 August 2013<br />
single core Board<br />
Ltd., U.A.E.<br />
Fire Resistant Cable (316) "Irish Driver-Harris" (IDH) Kilflam Fire Resistant Cables, Irish Driver-Harris Co. Ltd., Ireland 22/9/2008 September 2013 tests for C, W and Z categories for<br />
Model: Kilflam 1000, Kilflam 1200, Kilflam 2000 and Kilflam<br />
cables Kilflam 1000 and Kilflam 1200<br />
3000<br />
were done in steel conduit<br />
Fire Resistant Cable (318) Cableplus "Firepro" Fire Safety Cables, Models: Cableplus<br />
"Firepro" Fire Safety Cables, Sizes: 1.0mm 2 to 16mm 2<br />
Cableplus (SuZhou) Technologies 2/10/2008 February 2013 A valid " Certificate of Product<br />
Co.,Ltd., PRC<br />
Conformity" by LPCB shall be made<br />
inclusive, single core (exact sizes as detailed in LPCB<br />
Certificate No. 827a Issue No. 01)<br />
available.<br />
Fire Resistant Cable (332) MAS "Fireres" "FR2C" Fire Resistant Cables<br />
Hebei Huatong Wire & Cable<br />
24/11/2008 November 2013<br />
Model: FR2C<br />
Manufacture Co., Ltd., P.R.C.<br />
Fire Resistant Cable (337) Sigma Fire Resistant Cables<br />
Sigma Cable Company (Pte) Ltd., 19/12/2008 December 2013 Valid "Certificate of Conformity" on<br />
Model: a) "EL-600MA"<br />
Singapore<br />
compliance with SS 299: Part 1:1998<br />
b) "ESL-600MA"<br />
shall be made available on request.<br />
page12/40
Fire Resistant Cable (369) Nexans Fire Resistant Cables<br />
Model: a) Alsecure NX100<br />
b) Alsecure NX400<br />
Fire Resistant Cable (373) WILSON / FR-3S / Plain, annealed, stranded copper<br />
conductor with mica tape layer and crosslink L.S.O.H.<br />
insulation (red and black) 2C x 1.0 mm 2 to sC x 2.5 mm 2<br />
Fire Resistant Cable (381) MAS "Fireres" / a) FRIC single-core (conduit wiring) fire<br />
resistant cables b) FRICXL single-core (surface power<br />
cable) fire resistant cables c) 694nXFR n-core armoured<br />
fire resistant cables (where n runs from 2 to 5 and 7 to 48)<br />
Fire Resistant Cable (408) Datwyler / Pyrofil Fire Safety / Comprising copper<br />
conductors insulated by a double layer insulation with a<br />
high temperature resistant glass fiber tape, an A1laminated<br />
tape screening and a flame-retarded polyolefin<br />
outer sheath<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Nexans Ireland Ltd., Ireland 2/6/2009 June 2014 a) As testing of large size single core<br />
cables in accordance with BS 6387 for<br />
Cat. C, W, Z is not practicable,<br />
assessment of such cables would only<br />
be made on project basis. b) The<br />
cables shall carry markings as detailed<br />
in the letter from Nexans Ireland Ltd.<br />
ref.: DD230109 of 23.1.2009 c) This<br />
assessment is valid only for the<br />
batches of cables named above<br />
manufactured by Nexans Ireland Ltd.<br />
up to 25.7.2008 at their production<br />
facility in Ireland.<br />
Wilson Cables Private Ltd.,<br />
Singapore<br />
Hebei Huatong Wire & Cable<br />
Manufacture Co., Ltd., P.R.C.<br />
16/6/2009 June 2014 A valid Certificate of Conformity by<br />
PSB Singapore covering the cables<br />
shall always be available.<br />
13/7/2009 July 2014 a) It is recognized the difficulties to<br />
carry out BS 6387 CWZ for large size<br />
single core cables. Therefore, these<br />
large size cables are acceptable for<br />
inter-connection within a cubicle or<br />
electrical panel only. Other<br />
applications should be submitted for<br />
consideration on project basis. b) A<br />
valid "Certificate of Conformity" on<br />
quality management system shall be<br />
made available on request. c) This<br />
letter supersedes our previous one of<br />
the same series dated 5.12.2006,<br />
28.1.2008 and 22.10.2008 for the<br />
same brand of cables.<br />
Datwyler AG, Switzerland 20/1/2010 January 2014 A valid LPCB Certificate shall be made<br />
available and the cable shall be<br />
labelled with the appropriate LPCB<br />
mark<br />
page13/40
Fire Resistant Cable (409) WILSON / a) FR-3S - 1C x 1.5 mm 2 to 4.0 mm2, b) FR-100<br />
- 2C x 1.0 mm2 to 1.5 mm2 with or without earthconductor<br />
(CPC), c) FR-108 - 2C x 1.5 mm2 to 4C x 4.0 mm2 with or<br />
without earth conductor (CPC), d) FR-200A - 1C x 120<br />
mm2 to 1,000 mm2, d) FR-200A - 2C x 1.5 mm2 to 4C x<br />
300 mm2 and 5C x 1.5 mm2 to 37C x 4.0 mm2 / a)<br />
stranded copper conductor / mica tape barrier / PE<br />
insulation / LSF compound sheath, b) Armour cables with<br />
galvanised round steel / aluminium wires as indicated on<br />
the relevant Certificate of conformity<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Wilson Cables Private Ltd.,<br />
Singapore<br />
21/1/2010 December 2012 Valid Certificate of Conformity shall be<br />
made available for all cable models.<br />
Fire Resistant Cable (424) Wilson Cables / FR-200 a) 1C x 1.5 mm 2 to 1,000 mm 2 , b)<br />
2C x 1.5 mm 2 to 4C x 300 mm 2 , & c) 5C x 1.5 mm 2 to 37C x<br />
4.0 mm 2 Wilson Cables Private Ltd.,<br />
26/4/2010 March 2013 Valid Certificate of Conformity shall be<br />
Singapore<br />
/ Stranded copper conductor/mica tape<br />
barrier/XLPE insulation/LSOH/LSF compound sheath<br />
made available for all cable models.<br />
Fire Resistant Cable (427) Draka / a) "Sifer 950i" and "Saifer 950s" single-core fire Drake UK Ltd., U.K. 3/2/2009 February 2014 A valid "Certificate of Product<br />
resistant cables, b) "Firetuf Power OHLS" multi-core<br />
Conformity" by LPCB shall be made<br />
armoured fire resistant cable / a) "Sifer 950i" and "Saifer<br />
950s" are both single-core fire resistant cable with stranded<br />
copper conductor, mica glass or polyester tape barrier,<br />
cross linked OHLS type E15 insulation with OHLS type<br />
LTS1 sheath (for model Sifer 950s only). b) "Firetuf" power<br />
cable is of stranded copper conductor / mica & polyester<br />
tapes barrier / cross linked polyrthylene insulation /<br />
interlocked polyester tape wrapping / OHLS thermoplastic<br />
bedding sheath / galvanised steel wire armour / OHLS<br />
thermoplastic sheath.<br />
available.<br />
Fire Resistant Cable (428) Draka / a) FTPU 950 fire resistant Mifer OHLS, b)<br />
Easystrip, c) Firetuf Plus / a) "FTPU 950 fire resistant Mifer<br />
OHLS" are fire resistant OHLS insulated and sheathed<br />
multi-core cables, b) "Eaststrip" are fire resistant silicon<br />
rubber insulated and OHLS sheated multi-core cables, c)<br />
"Firetuf Plus" are fire resistant silicon rubber insulated and<br />
OHLS sheathed multi-core cables<br />
Drake UK Ltd., U.K. 26/2/2009 February 2014 Valid "Certificate of Product<br />
Conformity" by LPCB shall be made<br />
available for the cables.<br />
page14/40
Fire Resistant Cable (432) Nexans / NX400 Alsecure Plus / Armoured multi-core cable<br />
with stranded copper conduxtor / mica tape / XLPE<br />
insulation / polyolefin inner and outer sheath<br />
Fire Resistant Cable(441) "DUCAB BICC" DUCAB - FR SC Fire Resistant Cables /<br />
Ducab - FRSC / Cables comprising stranded copper<br />
conductors - mica glass tape - XL-LSF insulation<br />
Fire Resistant Cable(446) Irish Driver-Harris / Kilflam 1000, Kilflam 1200, Kilflam 2000<br />
and Kilflam 3000 / Single or multi-core cable with annealed<br />
copper conductor, mica glass tape, silicon rubber insulation<br />
and LSZH sheathing<br />
Fire Resistant Cable(452) KEYSTONE / FR 7211 / Single core cable comprising solid<br />
/ stranded plain copper conductor, mica glass tape, Mylar<br />
tape and a LSNH insulation<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Nexans Turkiye Endustri Ve Ticaret<br />
A.S., Turkey<br />
Dubai Cable Company(Private)<br />
Ltd., U.A.E.<br />
11/5/2010 May 2014 a) A valid product certificate issued by<br />
BASEC shall be made available at all<br />
times; the cable shall carry markings<br />
detailed in the above listed certificates,<br />
b) The cable shall carry markings<br />
detailed in the above listed certificates,<br />
c) This letter supersedes our previous<br />
one of the same series dated<br />
04.02.2010 on the same product.<br />
26/5/2010 May 2015 The cables are designed for laying in<br />
metal conduit or on metal cable tray.<br />
Valid ISO 9001 certificate shall be<br />
maintained.<br />
Irish Driver-Harris Co. Ltd., Ireland 5/7/2010 July 2015 Tests for C, W and Z categories for<br />
cables Kilflam 1000 and Kilflam 1200<br />
were done in steel conduit. Valid<br />
certificates issued by Loss Prevention<br />
Certification Board shall be made<br />
available on request.<br />
Dongguan Keystone Electric Wire<br />
& Cable Company Limited, PRC<br />
Fire Resistant Cable(454) Samson / SP3025HT/LS / Comprise of low smoke halogen Sun Shine Metal Electrical Mfg.,<br />
free compound outer sheath, aluminium/polyester tape with<br />
tinned copper drain wire and annealed stranded circular<br />
tinned copper conductors insulated with low smoke halogen<br />
free compound and mica tape fire barrier<br />
Shenzhen, P.R. China<br />
Fire Resistant Cable (465) Nexans "NX100 Alsecure Plus" Fire Resistant Cables /<br />
Model: NX100 Alsecure Plus / Single-core cable with<br />
stranded copper conductor / mica tape barrier / polyolefin<br />
outer sheath Sigle core, 1.5mm 2 to 95mm 2<br />
Fire Resistant Cable (475) "Samson" Fire Resistant Cables, SP19021 HT/LS and<br />
SP3202 HT/LS a) 2 core, 0.65 mm 2 conductor b) 2 core,<br />
1.0 mm 2 conductor<br />
Fire Resistant Cable (517) "Pyrotenax" Pyro MI Mineral Insulated Cables / Heavy Duty,<br />
Light Duty & Twisted Light Duty<br />
Fire Resistant Cables (521) "DUCAB BICC" Ducab-FR Fire Resistant Cables / Ducab -<br />
FR<br />
Nexans Turkiye Endustri Ve Ticaret<br />
A.S., Turkey<br />
Sun Shine Metal Electrical Mfg.,<br />
Shenzhen, PRC<br />
Tyco Thermal Controls UK Ltd.,<br />
U.K.<br />
Dubai Cable Company(Private)<br />
Ltd., U.A.E.<br />
23/7/2010 July 2015 The cable shall carry markings.<br />
10/8/2010 August 2013 a) A valid certificate for quality<br />
assurance scheme shall be made<br />
available at all times, b) the cable<br />
shall carry markings detailed above<br />
4/2/2010 February 2014 A valid product certificate issued by<br />
BASEC shall be made available at all<br />
times; the cable shall carry markings<br />
detailed in the above listed certificates<br />
25/11/2010 November 2015 a) A valid certificate for qulity<br />
assurance scheme shall be made<br />
available at all times. b)The cables<br />
shall carry markings detailed.<br />
30/5/2011 May 2016 All cables shall bear the appropriate<br />
LPCB markings.<br />
8/6/2011 June 2016<br />
page15/40
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Fire Resisrtant Cables (529) "Prysmian" Fire Resistant Cables / a) FP100 b) FP150 c)<br />
FP200 Gold d) FP200 Flex e) FP300 f) FP300MI g) FP400 /<br />
Single Core: a) "FP100" from 1.0 to 95 mm 2 b) "FP300"<br />
from 1.0 to 35 mm 2 c) "FP300MI" from 1.0 to 35 mm 2 2, 3 &<br />
4 Core: d) "FP150" from 1.0 to 2.5 mm 2 e) "FP200 Gold"<br />
from 1.0 to 4.0 mm 2 f) "FP200 Flex" from 1.0 to 2.5 mm 2 g)<br />
"FP300" from 1.0 to 16 mm 2 h) "FP400" from 1.0 to 400<br />
mm 2 Others: "FP200 Gold 1.0 mm 2 ; 1.5 mm 2 Prysmian Cables & Systems Ltd.,<br />
UK<br />
, 7, 12 & 19<br />
coreand25mm 2 7&12core<br />
Fire Resistant Cable (554) Royal Horse "H07Z1-R (Type 1)" Fire Resistant Cable /<br />
H07Z1-R (Type 1) / Single core non-sheathed cable with<br />
stranded rigid conductor, mineral ceramic (mica/glass) tape<br />
and a LSZH insulation / Conductor Size: 1.5 to 16 mm 2<br />
Fire Resistant Cable(566) "SEGURFOC" Fire Resistant Cables / a) SEGURFOC FR<br />
950 07Z-R-M cable b) SEGURFOC FRA 950 armoured<br />
cable c) SEGURFOC FRA 950-1 armoured cable / a)<br />
SEGURFOC FR 950 07Z-R-M cable Single core, nominal<br />
csa 1.5 to 16 mm 2 b) SEGURFOC FRA 950 armoured<br />
cable 2, 3, 4 core, nominal csa 1.5 to 185 mm 2 c)<br />
SEGURFOC FRA 950-1 armoured cable 2, 3, 4 core,<br />
nominal csa 240 to 400 mm 2<br />
Fire Resistant Cable(569) "KME" Mineral Insulated Cables / Mineral Insulated Cable<br />
a) MICO - KME Light Duty b) MICO - KME Single Core<br />
Heavy Duty c) MICO - KME Multie Core Heavy Duty / Exact<br />
number of cores and sizes are as detailed in Loss<br />
Prevention Certification Board (LPCB) Certificate No. 427a<br />
(Issue No. 10)<br />
S.G.H. Electric Wire & Cable Co.,<br />
Ltd., PRC<br />
Grupo General Cables Sistemas<br />
S.A., Spain<br />
Fire Resistant Cable(571) Oman Cables Industry (SAOG) "OCIFLAM-FSA" Fire<br />
Resistant Cables / "OCIFLAM-FSA" 2, 3 and 4-core<br />
armoured fire resistant cables / Stranded annealed plain<br />
copper conductor / mica glass tape covered with XLPE<br />
insulation / LSF bedding / galvanized steel wire armour /<br />
LSF outer sheath Conductor Size : 16 - 400 mm 2 Oman Cables Industry (SAOG),<br />
, 2, 3 and<br />
4-core cable, as detailed in the appendix to Loss Prevention<br />
Certification Board Certificate No. 995a of 14.12.2011<br />
Sultanate of Oman<br />
Fire Resistant Cable(573) "Firecel" SR112 (Twisted) Cable cable Size : 1 x 2 x<br />
1.5mm 2<br />
Fire Resistant Cable (578) "KEYSTONE" Fire Resistant Armoured Cable Dongguan Keystone Electric Wire<br />
& Cable Company Limited,<br />
Guangdong, PRC<br />
23/6/2011 June 2016 a) Large single core cables mentioned<br />
in the above certificates and which<br />
comply with BS 6387 Cat. C only will<br />
be considered on project basis. B) All<br />
cables shall bear the appropraite<br />
LPCB markings.<br />
6/10/2011 October 2016 The cable shall bear the KEMA-KEUR<br />
certification mark and other<br />
appropriate markings.<br />
20/1/2012 January 2017 a) Large fire resistant single core<br />
cables mentioned in Certificate No.<br />
722a (Issue No. 02) which comply with<br />
BS 6387 Cat. C or C, W only will be<br />
considered on project basis. B) The<br />
cables shall bear the appropraite<br />
"LPCB" mark.<br />
KME Italy S.P.A., Italt 10/2/2012 February 2017 a) A valid certificate issued by LPCB<br />
shall always be available. b) The<br />
cables shall bear the appropriate<br />
"LPCB" mark.<br />
16/2/2012 February 2017 The cables shall bear the appropriate<br />
"LPCB" mark<br />
Cavicel SpA, Italy 14/3/2012 March 2015 The SR112 (Twisted) cable is to be<br />
enclosed in steel conduit and/or metal<br />
trunking.<br />
3/5/2012 May 2017 The cable shall bear the LPCB mark<br />
for identification purpose.<br />
page16/40
Fire Resistant Cable(579) "Firecel" SR112 single core and SR114H & SR114E multicore<br />
copper cables<br />
Fire Resistant Cable(592) ATOM Fire Barrier S Single Core Fire Resistant Cables /<br />
ATOM Fire Barrier S / No. of Core and Size: Single core,<br />
1.5mm 2 to 70mm 2 (Sizes as indicated in LPCB Certificate<br />
No. 905b, Issue No. 01 of 23.4.2012)<br />
Fire Resistant Cable(603) ACT® 2/3/4-Core Fire Resistant Power Cables / "ACT^®"<br />
Two-Core LSZH Fire Resistant Armoured Power Cables,<br />
Type 6942B-FR, "ACT^®" Three-Core LSZH Fire Resistant<br />
Armoured Power Cables, Type 6943B-FR, "ACT^®" Fouro-<br />
Core LSZH Fire Resistant Armoured Power Cables, Type<br />
6944B-FR<br />
Fire Resistant Cable (604) ATOM KABLO / Atom Fire Barrier L / Construction :<br />
Armoured multi-core cable with standed copper conductor /<br />
mica tape / XLPE insulation / LSZH filler and outer sheath /<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
No. of core and size : 2, 3, 4 and 5 cores, 1.5mm 2 to<br />
35mm 2 7, 12 and 19 cores, 1.5mm 2 to 4.0mm 2 (Sizes as<br />
indicated in LPCB Certificate No. 905a, Issue No. 02 of<br />
3.8.2012)<br />
Fire Resistant Cable(626) "Firestop" FS-90 Fire resistant Cables / Firestop FS-90<br />
Multicore Cable / Conductor Sizes : 1.5 to 400 mm 2<br />
inclusive, 4-core<br />
Fire Resistant Cable (617) AEI "Firetec" Single Core Fire Resistant Cables / Firetec<br />
Single Core LSZH cables / Sizes : 1.0 to 35 mm 2 inclusive,<br />
single core (exact sizes as detailed in LPCB Certificate No.<br />
221c, Issue No. 08)<br />
(5) Flexible Connectors<br />
Cavicel SpA, Italy 16/5/2012 May 2017 a) The single core SR112 cables must<br />
be enclosed in steel conduit and/or<br />
metal trunking b) The cable shall bear<br />
the LPCB mark for identification<br />
purpose.<br />
ATOM KABLO SANAYI ve Ticaret<br />
A.Ş., Turkey<br />
Tianjin Suli Cable Group Co. Ltd.,<br />
PRC<br />
ATOM KABLO SANAYI ve Ticaret<br />
A.Ş., Turkey<br />
Prysmian Power Cables and<br />
Systems Australia Pty Ltd.,<br />
Australia<br />
27/7/2012 July 2017 a) The cables shall be enclosed in<br />
steel conduits. b) The cables shall<br />
bear the appropriate LPCB markings.<br />
27/9/2012 October 2015 The cable shall bear the "ACT®" trade<br />
name and KEMA-KEUR certification<br />
mark for identification purpose.<br />
4/10/2012 October 2014 The cable shall carry markings<br />
detailed in the above listed certificates.<br />
27/10/2012 May 2016 Valis ISO 9001 certificate should be<br />
maintained.<br />
AEI Cables Limited, Durham, UK 27/11/2012 November 2017 a) The cables shall be enclosed in<br />
steel conduits as stipulated in the Test<br />
Certificate. b) The cables shall bear<br />
the "LPCB" mark. c) A valid<br />
"Certificate of Product Conformity" by<br />
LPCB shall be made available.<br />
page17/40
Flexible Connector(430) Class "0" Ductflex Flexible Duct Connector for Use in<br />
Ventilation Systems / a) Ductflex 70A & b) Ductflex 300 / a)<br />
Reinforced fibreglass coated on both sides with rubber with<br />
an overall thickness of 0.5 to 1.0 mm, area density of 0.52<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
kg/m 2 and with a standard reference black colour 7 b)<br />
Reinforced woven fibreglass with stainless steel wire,<br />
coated on both sided with fire resistance silicon rubber with<br />
an overall thickness of 1.0 to 1.5 mm, area density of 1.92<br />
kg/m 2 with a standard reference orange brown colour<br />
Flexible Connector (526) "COLAN" AF406/FRN Textile Fabric / AF406/FRN (Flame<br />
Retardant Neoprene) textile fabric / A black glass fibre<br />
fabric with a nominal thickness of 0.54 mm and a nominal<br />
weight of 800 g/m 2 woven from satin weave Type E glass<br />
fibre and coated on both sides with flame retarded<br />
neoprene.<br />
Flexible Connector (551) Colan "AF805 SIL" Glass Fibre Fabric as Flexible<br />
Connector in Ventilation/Smoke Extraction System /<br />
"COLAN AF805 SIL" glass-fibre fabric / A woven fibreglass<br />
fabric (high bulk borosilicate type) with silicon rubber<br />
coating on both sides, having an overall thickness of 2.2<br />
mm and weight of 1570 g/m 2 , and with a standard<br />
reference colour red.<br />
(6) Fire/ Fire & Smoke Dampers<br />
Fire Damper "RUSKIN TFD 80" Heavy Duty Fire and Smoke Damper (G<br />
I) (169)<br />
Guang Zhou Jitai Development Co.<br />
Ltd., P.R.C.<br />
3/5/2010 May 2013 a) No assessment was made on the<br />
smoke generation by the material<br />
under fire condition. & b) The products<br />
shall bear suitable model name<br />
makings.<br />
Colan Products Pty Ltd., Australia 13/6/2011 June 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by material under fire. b)<br />
The material shall bear the marking<br />
"AF406 FRN" as a means of<br />
identification.<br />
COLAN Products Pty Ltd.,<br />
Australia<br />
Ruskin Company (Supplier: Applied<br />
Technology Intergration Ltd)<br />
26/9/2011 September 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by material under fire. b)<br />
The product shall have label tag(s)<br />
bearing the word "AF805 SIL" sewn on<br />
it as a means of identification.<br />
12/12/2006 December 2012<br />
Fire Damper (205) Advanced <strong>Air</strong> - series 0100 Curtain Type Fire Damper Advanced <strong>Air</strong> (UK) Ltd. 11/5/2007 April 2012<br />
Fire & Smoke Damper (243) Ruskin Model FED36 Fire and Smoke Damper - Horizontal<br />
Mounting 3458 mm(W)X2438mm(H); Vertical mounting<br />
3048mm(W)X2438mm(H)<br />
Ruskin Co., USA or Thailand 9/11/2007 October 2012<br />
Fire Damper<br />
(248)<br />
"Greenheck" DFD Curtain Type Fire Damper<br />
a)DFD-150<br />
b)DFD-M150<br />
c)DFD-210<br />
d)DFD-M210<br />
Fire & Smoke Damper (259) "Greenheck" Fire & Smoke Damopers<br />
Series : a) FSDF-211 ; b) FSD-M211 Glavanised steel<br />
construction with blades with operated by actuactor.<br />
Proprietary Made Fire Damper<br />
(270)<br />
Fire Damper<br />
(272)<br />
"Safe-<strong>Air</strong> Dowco" Curtain Type Fire Damper Model:<br />
150, 151, 300 & D150<br />
"BSB" FD Series curtain type fire damper<br />
(Horizontal and vertical mounting)<br />
a) For DFD-150 and DFD-210<br />
Greenheck Fan Corporation, USA<br />
b) For DFD-M150 and DFD-M210<br />
Greenheck Khunsan, PRC<br />
a) 'Greenheck Fan Corporation,<br />
USA : b) Greenheck Khunsan,<br />
PRC<br />
14/12/2007 June 2012<br />
7/3/2008 June 2012<br />
Safe-<strong>Air</strong> ofIllinois Inc., USA 17/4/2008 April 2012<br />
BSB Engineering Limited, Kent,<br />
U.K.<br />
18/4/2008 December 2012<br />
page18/40
Fire Damper<br />
(293)<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
"SUSKIN" BIBD Series Curtain Type Fire Damper<br />
Model: DIBD 2, DIBD 2SS, DIBD 23 & BIDB 23SS<br />
Fire & Smoke Damper (300) "Safe-<strong>Air</strong> Dowco" Fire and Smoke Damper<br />
Model: 771, 772, 781 and 782 with frame collarof different<br />
forms<br />
Fire & Smoke Damper (380) Gilberts / "Ductgard" / A combined fire and smoke damper<br />
comprising a galvanized steel frame with stainless steel<br />
interlocking blades and frame side seals<br />
Fire Damper (382) Actionair / FBL, FBH, FBC, FBO / Un-insulated galvanised<br />
steel folded blade fire damper comprising 0.7 mm thick G.I.<br />
interlocking folding blades encased in a 1.2 mm thick G.I.<br />
steel channel section frame. A locking ramp which is made<br />
of 1.5 mm thick G.I. sheet is provided to ensure the blade<br />
remained in position when the damper is closed. Other<br />
details of the damper construction are as detailed in test<br />
report no. TE 214030.<br />
Fire and Smoke Damper (401) &<br />
(546)<br />
Lloyd / FSD-111-1 and FSD-111-2 / Channel frame<br />
constructed of 1.6 mm G.I. steel with an interlocking<br />
stacked hat section and 1.6 mm thick G.I. V-formed blades.<br />
Linkage device is zinc-plated steel concealed within the<br />
channel frame. The product can also be of an entirely<br />
stainless steel (Grade 304 or 316) or a combination of G.I.<br />
steel and stainless steel construction as described in the<br />
Assessment Report mentioned below<br />
Fire Damper (414) RUSKIN / IBD / A curtain damper formed by interlocking<br />
galvanized mild steel / stainless steel (Grade 304 or 316)<br />
blades mounted in a galvanized mild steel/stainless steel<br />
(Grade 304 or 316) frame held in open position by fusible<br />
link; closure of damper is effected by stainless steel<br />
springs.<br />
Fire Damper (443) Actionair / Fire, Shield Series 101, 201, 301 and 401 / Uninsulated<br />
stainless steel folded blade fire damper having<br />
unbroken joints and comprising of stainless steel constant<br />
tension closure springs and stainless steel peripheral<br />
gasket. The assembly should be fitted into the structure<br />
with a galvanized steel "HEVAC/HVAC" installation frame.<br />
Ruskin Co., USA, PRC or Thailand 8/7/2008 July 2013<br />
Safe-<strong>Air</strong> of Illinois Inc., USA 18/7/2008 July 2012 These dampers are not intended for<br />
smoke extraction system and<br />
staircase pressurization system.<br />
Gilberts (Blackpool) Ltd., UK 10/7/2009 July 2012 The dampers shall be permanently<br />
marked or stamped with label(s) which<br />
shall remain visible after it is fixed into<br />
position for the identification of its<br />
brand name and model<br />
Ruskin <strong>Air</strong> Management Ltd., UK 15/7/2009 March 2014 The dampers are to be fitted with<br />
fusible links designed to operate up to<br />
a temperature of 69 o C and approved<br />
by this department.<br />
Lloyd Industries Inc., USA 09/12/2009 9/9/2011 December 2013 a) The damper shall remain listed in<br />
the UL Certifications Directory,<br />
b) The dampers shall be permanently<br />
marked or stamped with label(s) which<br />
shall remain visible after fixed into<br />
position for the identification of brand<br />
name and model<br />
Delta Pyramax Co. Ltd. 7/4/2010 April 2015 The fusible link used with the damper<br />
shall be of a type approved by the<br />
Director of FS and with a rating not<br />
exceeding 69 o C<br />
Ruskin <strong>Air</strong> Management Ltd., UK 22/6/2010 June 2014 The fusible link shall be of FSD<br />
approved type with a rating not<br />
exceeding 69oC<br />
page19/40
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Fire Damper (449) TANDA / TFD - 100 series is a curtain type completed with Shenzhen Longgang Pingshan<br />
integral sleeve; the frame is made of four pieces of steel Jiangling Luen ming Manufacturing<br />
sheet joined at the corners by riveted overlaps. This is fitted Factory, PRC<br />
centrally inside a duct and fastened together by rivets. The<br />
curtain comprises interlinked slats with the top one riveted<br />
to the frame. The damper can be of full galvanized steel,<br />
full stainless steel, galvanized steel frame with stainless<br />
steel curtain or stainless steel frame with galvanized steel<br />
curtain construction. The stainless steel can be of Grade<br />
304 or 316. & TFD - 200 series is a curtain type with frame<br />
formed from C-section steel. The curtain comprises<br />
interlinked slats with the top one riveted to the frame. The<br />
damper can be of full galvanized steel, full stainless steel,<br />
galvanized steel frame with stainless steel curtain or<br />
stainless steel frame with galvanized steel curtain<br />
construction. The stainless steel can be of Grade 304 or<br />
316.<br />
Fire Dampers (457) TROX / a) FSD series, b) FSP series, c) FSE series / a)<br />
FSD series - Fire damper assemblies of galvanised mild<br />
steel construction using a curtain type arrangement, b) FSP<br />
series - Fire damper assemblies similar to FSD series, but<br />
with blades constructed from stainless steel Grade 430, c)<br />
FSE series - Fire damper assemblies similar to FSD series<br />
with the catch plates and the case being constructed from<br />
stainless steel Grade 304L<br />
Fire & Smoke Damper (473) &<br />
(507)<br />
"TROX" SFD - Fire & Smoke damper / SFD Series /<br />
Assemblies is of galvanised mild steel construction, with1.5<br />
mm thick sleeve, 1.5 mm thick blades for vertical mounting<br />
and 2 mm thick for horizontal mounting, springs and catch<br />
plates as described in the test reports. The frame is made<br />
up of top hat sections welded together. A linkage system<br />
enables all blades to move and lock together when in the<br />
closed position.<br />
9/7/2010 July 2015 a) A label to indicate the manufacturer,<br />
model, standards and fire resistant<br />
rating achieved should be fixed to the<br />
damper. b) The fusible link shall be of<br />
a type approved by this department.<br />
(Installation and Mounting Methods<br />
and Details: Refer to F. S. letter dated<br />
22.6.2012)<br />
Trox (Malaysia) Sdn. Bhd. 10/8/2010 July 2015 The dampers are to be fitted with<br />
fusible links release of a type<br />
approved by this department with a<br />
rating not exceeding 69 o C<br />
TROX Malaysia Sdn. Bhd.,<br />
Malaysia<br />
05/11/2010 16/3/2011 July 2015 The dampers shall be permanently<br />
marked or stamped with label(s) which<br />
shall remain visible after it is fixed into<br />
position for the identification of its<br />
brand name and model<br />
page20/40
Fire & Smoke Damper (500) "Prefco" Muti-blade Fir/Smoke Damper Series 5000 / Noninsulated<br />
multi-blade damper of galvanized steel<br />
construction complete with linkages<br />
Fire & Smoke Damper (515) "Trox" JFM Fire & Smoke Damper / "JFM-G-F" and "JFM-<br />
E-F" multi-leaf fire damper with vertical and horizontal<br />
mounting models<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Perfect <strong>Air</strong> Control Inc. 1/3/2011 March 2016 a) Separate actuator shall be fitted for<br />
each single damper module that<br />
makes up a multiple module. b) Valid<br />
assment report on the integrity of<br />
multiple module damper assembles to<br />
BS476:Part 20 shall always be made<br />
available.<br />
Trox (Malaysia) Sdn. Bhd.,<br />
Malaysia<br />
19/5/2011 March 2016<br />
Fire Damper (547) "Prefco" 5500 E4A Curtain Type Fire Damper / 5500 E4A Perfect <strong>Air</strong> Control Inc., USA 20/9/2011 September 2016 a) The damper shall be fitted with a<br />
FSD approved fusible link of<br />
temperature rating not exceeding<br />
69 o C. b) A valid assessment report<br />
shall be available to substantiate the<br />
fire resistance performance of the fire<br />
damper assembly.<br />
Fire Damper (548) "Prefco" 5500 E6-LPC Curtain Type Fire Damper / 5500<br />
E6-LPC<br />
Fire & Smoke Damper (576) RUSKIN "FSD60" Combined Fire & Smoke Damper.<br />
Construction: Details as described and illustrated in<br />
Warrres No. 43157 & SwRI Project No. 01.13537.01.312,<br />
0.7 mm thick galvanized mild steel frame with 0.3 mm thick<br />
stainless steel convex shaped side seals and G.I. blade<br />
stops with the longer leg welded to the web of the frame.<br />
Mounting: Vertical and horizontal. Maximun Sizes: a) Sigle<br />
section: 750 mm x 900 mm (W x H) b) Multiple section:<br />
3,048 mm x 2,438 mm (W x H) for electric and pneumatic<br />
actuator<br />
Perfect <strong>Air</strong> Control Inc., USA 20/9/2011 September 2016 a) The damper shall be fitted with a<br />
FSD approved fusible link of<br />
temperature rating not exceeding<br />
69 o C. b) A valid assessment report<br />
shall be available to substantiate the<br />
fire resistance performance of the fire<br />
damper assembly.<br />
Ruskin Co., USA or Thailand 26/3/2012 March 2017 The dampers shall maintain its status<br />
as an UL listed product.<br />
page21/40
Fire & Smoke Damper (588) "TROX" SFD, SFP and SFE Fire & Smoke Damper / SFD,<br />
SFP and SFE Series<br />
Fire Damper (590) "Actionair" Re-settable Thermal Release Cassette, Part No.<br />
CNNN 01983 / Temperature Rating: Not exceeding 69 o C /<br />
For use with "Actionair" Fire/Shield Series 101, 201, 301,<br />
401, FBL, FBH, FBC and FBO bladed curtain fire dampers<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
TROX Malaysia Sdn. Bhd.,<br />
Malaysia<br />
Fire Damper (600) "LASER" 9020 Series Curtain Type Fire Damper for Use in Laser Resources (Asia) Co. Ltd.,<br />
Ventilation System / "LASER" curtain type fire damper / a)<br />
9020 GV - G.I. frame and blade (without spring loaded<br />
housing) b) 9020 G - G.I. frame and blade c) 9020 S - G.I.<br />
frame and stainless steel blade d) 9020 SS - Stainless steel<br />
frame and blade / The damper comprises interlinked<br />
galvanized steel / stainless steel damper slats housed in<br />
galvanized steel / stainless frames with / without spring<br />
loaded housing. The stainless steel can be of Grade 304 or<br />
316.<br />
Hong Kong<br />
27/6/2012 July 2015 The dampers shall be permanenly<br />
marked or stamped with label(s) which<br />
shall remain visible after fixed into<br />
position for the identification of brand<br />
name and model.<br />
Ruskin <strong>Air</strong> Management Ltd., U.K. 6/7/2012 January 2014 The cassette shall bear the following<br />
product identification marks on its<br />
body: a) Brand name b) Temperature<br />
tating mark of 69 o C c) Circular dial<br />
date showing the month and year of<br />
manufacture<br />
24/8/2012 January 2017 a) Inspection reports covering routine<br />
inspection and "check tests" done in<br />
accordance with the schedule of the<br />
follow-up services by Vipac Engineers<br />
and Scientists (HK) Ltd., shall be<br />
made available on request. b) The<br />
damper shall bear the "Laser" trade<br />
mark and production label with<br />
company name and model number is<br />
attached on the damper. c) The<br />
dampers are to be fitted with fusible<br />
links approved by this department and<br />
designed to operate up to a<br />
temperature of 69 o C<br />
page22/40
Fire & Smoke Damper (619) "LASER" 9010 Series Combined Fire and Smoke Damper<br />
for Use in Smoke Control / Ventilation System / "LASER"<br />
blade type combined fire and smoke dampers / a) 9010G -<br />
G.I. frame and blade (vertical & horizontal mounting) b)<br />
9010S - G.I. frame and stainless steel blade (vertical &<br />
horizontal mounting) / The damper comprises profiled<br />
galvanized steel / stainless steel (Grade 304 or 316)<br />
damper blades housed in galvanized mild steel frames with<br />
blade linkage and operated by electric actuator. The<br />
thickness of the steel, the clearance between the blade<br />
ends and the frame and other details shall be as described<br />
in BRANZ report nos. FR 3606 (Issue 2) AND far 2922<br />
(iSSUE 2) Size: 200mm(W) x 200 mm (H) - 900 mm (W) x<br />
900 mm (H) for each module Maximum size up to: a)<br />
Horizontal - 2788 (W) x 1844 mm (H) (3 x 2 modules) b)<br />
Vertical - 3732 mm (W) x 2788 mm (H) (4 x 3 modules)<br />
(7) Flexible Ducts<br />
Flexible Duct (317) "ISODUCT" Flexible Duct for use in Mechanical Ventilation<br />
Systems, Model "Econoflex A-1 I25 AL"<br />
Flexible Duct (387) Aluduct / A flexible duct comprising a core layer of<br />
aluminium laminate with an encapsulated high tensile<br />
spring steel wire helix, an insulation layer of fibreglass<br />
blanket (25 mm thick and density of 16 kg/m 3 ) and an outer<br />
vapour barrier layer made of aluminium foil.<br />
Flexible Duct (415) Wyser-<strong>Air</strong> / FDI - 16 / An inner core fabricated from a<br />
scrim-reinforced polyester and aluminium laminate,<br />
completely encapsulating a steel wire helix, bonded with a<br />
double seam of hot melt adhesive, a core of fire blass<br />
insulation having a thickness of 25mm and a density of 16<br />
kg/m 3 , an outer vapour barrier jacket comprising a polyester<br />
and aluminium laminate<br />
Flexible Duct (470) "AFS" Flexible <strong>Air</strong> Duct / a) ALUAFS.70, b) ISOAFS-ALU,<br />
c) SONOAFS-ALU / Duct Diameter 102mm to 356mm<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Laser Resources (Asia) Co. Ltd.,<br />
Hong Kong<br />
<strong>Air</strong> Trade Centre Limited 30/9/2008 April 2012<br />
11/12/2012 October 2016 a) Inspection reports covering routine<br />
inspection and "check tests" done in<br />
accordance with the schedule of the<br />
follow-up services by Vipac Engineers<br />
and Scientists (HK) Ltd. shall be made<br />
available on request. b) The damper<br />
shall bear the "Laser" trade mark and<br />
production label with company name<br />
and model number is attached on the<br />
damper. c) The dampers are to be<br />
fitted with fusible links approved by<br />
this department and designed to<br />
operate up to a temperature of 69 o C<br />
Jitai Development Ltd. PRC 3/8/2009 September 2014 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire.<br />
Wysermann Co. Ltd., HK 9/4/2010 April 2013 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire<br />
AFS Flexible Kanal Ticareti Ltd.<br />
Sti., Turkey<br />
29/9/2010 November 2014 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire<br />
page23/40
Flexible Duct (513) "PAL®" Winflex 33i Flexible <strong>Air</strong> Duct / "PAL®" Winflex 33i<br />
Insulated Aluminium Flexible <strong>Air</strong> Duct / A factory made<br />
insulated round flexible air duct of different diameters with<br />
inner foil facing encapsulating a high tensile spring steel<br />
wire helix to form the wall of the air duct which is insulated<br />
with 25 mm thick, density 24 kg/m 3 yellow colour fibreglass<br />
with double-sided aluminium foil facing.<br />
Flexible Duct (528) "PAL®" Winflex 33 Aluminium Flexible <strong>Air</strong> Duct / "PAL®"<br />
Winflex 33 Aluminium Flexible <strong>Air</strong> Duct / A factory made<br />
round flexible duct of aluminium foil polymer composite<br />
encapsulated a high tensile spring steel wire helix to form<br />
the wall of the duct. The duct can be of different diameters<br />
with an overall wall thickness of 0.033 ± 0.005 mm and<br />
overall weight of 100 g/m 2 ± 10%<br />
Flexible Duct (561) "Supaflex 13 AP" Flexible <strong>Air</strong> Duct / the duct comprises of<br />
an insulation layer of glasswool (light yellow colour, 25 mm<br />
thick, 24kg/m 3 ) sandwiched between an inner core of<br />
aluminium/polyester laminate encapsulating spring steel<br />
wire helix and an outer aluminium/polyester vapour barrier.<br />
Flexible Duct (587) "SK Kicflex" Aluminium Flexible <strong>Air</strong> Duct, Model "KIC-<br />
8000", 100mm to 200mm, a) An inner core fabricated from<br />
aluminium foil laminated with PET and aluminium foil with<br />
steel wire inserts, b) A core of fibre glass insulation with a<br />
thickness of 25mm and density of 24kg/m 3 , c) An outer<br />
jacket comprising aluminium foil laminated with PET.<br />
(8) Energy Recovery Units<br />
Energy Recovery Wheel (383) <strong>Air</strong>xchange / "ECR" Series as listed in the UL Certifications<br />
Directory, File No.: SROT2.SA9792 / the energy recovery<br />
wheel is constructed of silica gel desiccant bounded light<br />
weight polymer media mounted on a stainless steel rotor.<br />
For wheels of diameter greater than 26 in., the media shall<br />
be mounted in the form of removable segments.<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Dongguan Juwun Rubber & Plastic<br />
Products Co. Ltd., PRC<br />
Dongguan Juwun Rubber & Plastic<br />
Products Co. Ltd., PRC<br />
15/4/2011 December 2015 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire<br />
condition. b) The Brand name and<br />
model number should be marked on<br />
the product.<br />
23/6/2011 April 2016 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Delta Duct Systems Ltd., PRC 12/12/2011 December 2014 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire. b)<br />
The word "SUPAFLEX" is to be<br />
marked on the outer surface of the<br />
product at approx. 1,000 mm interval<br />
for product identification.<br />
SK Kicflex Co. Ltd. PRC 19/6/2012 September 2013 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire<br />
<strong>Air</strong>xchange Inc., USA 24/7/2009 July 2014 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the core material under<br />
fire condition. B) The product shall<br />
remain UL listed and bear the<br />
appropriate marking<br />
page24/40
Energy Recovery Wheel (456) EcoFresh / "EcoFresh" HWR Series heat recovery wheel /<br />
A rectangular galvanized steel enclosure containing a belt<br />
driven metallic spoke housing removable sectors of core<br />
material for heat/humidity exchange. The core material is<br />
desiccant - "Molecular Sieve 3A (Ecosorb 300)" coated on<br />
a corrugated aluminium foil substrate<br />
Energy Recovery Ventilator<br />
(508)<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
"STC-EHRV" Energy Humidity Recovery Ventilator / "RP"<br />
Series / An internally insulated rectangular galvanized steel<br />
enclosure containing a belt driven stainless steel rotary<br />
wheel housing six removable sectors of core material for<br />
heat/humidity exchange. The core material is packed 40<br />
mm thick polyester (PE) fiber of 25 - 150 micrometer<br />
diameter with a surface density of 3.6 kg/m 2 . Two sets of<br />
aluminium pre-filters are fitted on the air inlets of the unit.<br />
Unit Size : 2,000m 3 /h to 40,000m 3 /h<br />
Desiccant Rotors International,<br />
India<br />
Hong Kong Stirling Ventilator Co.,<br />
Ltd., PRC<br />
(9) Smoke Fans<br />
Smoke Fan (302) "F.LLI Ferrari"FR Series F.LLI Ferrari Ventilatori Industriali<br />
S.P.A., Italy<br />
Smoke Fan (404) Fantech / APS, SS, RSS and SSM Series of sizes from 315<br />
mm to 2,000 mm diameter / Heavy gauge mild steel and<br />
hot dip galvanized casing, axial fan comprising aluminum<br />
blade impeller; driven by high temperature rating electric<br />
motor manufactured by "TECO" or "CMG" (max. power 90<br />
kW) of insulation Class "H", 3 phases, 415V, 50 Hz supply<br />
Fantech Pty. Limited, Australia<br />
EltaFantech Asia Sdn. Bhd,<br />
Malaysia<br />
12/8/2010 Aug 2013 a) All electric cables installed inside<br />
the product and exposed to the air<br />
stream are to be contained in flexible<br />
metal conduit. B) Valid test report<br />
shall be made available on request to<br />
demonstrate that the internal<br />
insulation, if any, used in the product<br />
can comply with the requirement of<br />
having an overall fire propagation<br />
index I < or = 6 when tested in<br />
accordance with BS 476 Part 6: 1989.<br />
18/3/2011 March 2015 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the core material under<br />
fire condition. b) All electric cables<br />
installed inside the ventilator are to be<br />
contained in flexible metal conduit. c)<br />
Valid test report shall be made<br />
available on request to demonstrate<br />
that the internal insulation used in the<br />
ventilator can comply with the<br />
requirement of having an overall fire<br />
propagation index I � 12, sub-index i 1 �<br />
6 when tested in accordance with BS<br />
476 Part 6:1898.<br />
31/7/2008 August 2012<br />
7/1/2010 June 2012 A valid " Certificate for Quality<br />
Management System" shall be<br />
maintained<br />
page25/40
Smoke Fan (431) Flakt Woods / As listed in the Appendix to BSRIA<br />
Performance Certificate No. C18421/1, Issue 4 of<br />
29.04.2010, but only limited to those with temperature and<br />
time categories equal to or better than 250 o C and 1 hour /<br />
Circular axial flow fan incorporating inlet and outlet flanges;<br />
fan impeller is of die cast aluminium alloy with a totally<br />
enclosed induction motor of an insulation grade selected to<br />
meet specific performance requirements<br />
Smoke Fan (458) Wolter / a) JFUO and JFRO Series - Impeller diameter<br />
300mm to 355mm, b) AXV Series - Impeller diameter<br />
315mm to 1600mm, c) RVHT Series - Impeller diameter<br />
355mm to 710mm<br />
Smoke Fan (492) Kruger "TDA-F" Smoke Spill Axial Fan for Smoke<br />
Extraction System / Smoke Spill Axial Fan a) TDA 400-F b)<br />
TDA 630-F c) TDA 900-F d) TDA 1400-F Axial fan<br />
comprising aluminium fan blades of manually adjustable<br />
pitch, mild steel or galvanised steel flanged casing and<br />
driven by "kruger" high temperature resistance Class "H"<br />
electric motor<br />
Smoke Fan (494) Witt & Sohn "KWJ" Smoke Spill Axial Fan for Smoke<br />
Extraction System / "Witt & Sohn" Reversible Smoke Spill<br />
Axial Fan a) KWJ 630 (with 7.5 kW, 2P motor) b) KWJ<br />
1120 (with 37kW, 4P motor) Axial fan comprising<br />
aluminium fan blades of manually adjustable pitch,<br />
galvanised mild steel flanged casing and driven by "kruger"<br />
high temperature resistance Class "H" electric motor<br />
Smoke Fan (496) Witt & Sohn "TSS 1800" Smoke Spill Axial Fan for Smoke<br />
Extraction System / Witt & Sohn "TSS 1800" Reversible<br />
Smoke Spill Axial Fan (with 150 kW, 6P motor) / Axial fan<br />
comprising aluminium fan blades of manually adjustable<br />
pitch, galvanised mild steel casing driven by "Kruger" high<br />
temperature Class 'H' electric motor<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
The Flakt Woods Group, U.K. 11/5/2010 April 2013 The family of "JM Aerofoil HT" Series<br />
fans shall bear an appropriate<br />
identification mark for the identification<br />
of time / temperature categories.<br />
Walter GmbH Maschinen-und<br />
Apparatebau KG, Germany<br />
Kruger Ventilation Industries Pte.<br />
Limited, Singapore<br />
Kruger Witt Asia Industries Pte.<br />
Limited, Singapore<br />
Kruger Witt Asia Industries Pte.<br />
Limited, Singapore<br />
24/8/2010 August 2015 a) Valid "EC - Certificate of<br />
Conformity" shall be maintained for the<br />
fan models, b) A valid certificate for<br />
quality management system shall be<br />
maintained.<br />
1/2/2011 February 2015 The fans shall bear appropriate labels<br />
for the identification of time /<br />
temperature categories.<br />
2/2/2011 February 2015 The fans shall bear appropriate labels<br />
for the identification of time /<br />
temperature categories.<br />
14/2/2011 February 2015 The fans shall bear appropriate labels<br />
for the identification of time /<br />
temperature categories.<br />
page26/40
Smoke Fan (511) Kruger "BSB" Type F Smoke Spill Centrifugal Fan for<br />
Smoke Extraction System / Smoke Spill Centrifugal Fan<br />
(Type F) a) BSB 355 (with 1.1 kW, 4P motor), b) BSB 630<br />
(with 3.0 kW, 4P motor), c) BSB 1120 (with 18.5 kW, 4P<br />
motor) / Centrifugal fan comprising mild steel backward<br />
curved impeller and a galvanized sheet steel casing with<br />
inlet and outlet flanges. The fan is belt driven externally by<br />
"Kruger" high temperature resistance Class "F" electric<br />
motor.<br />
Smoke Fan (530) "Wolter" Axial Fan / AXV Series - Size 335 mm to 1,250<br />
mm / The fans are driven by IP55 single or two-speed high<br />
temperature motor of insulation class "H" by either<br />
"Siemens", "CMG", "WEG", "TECO", "ABB" or "Wolter<br />
(OEM)". The moters can be of 2/4/6/8 poles and operate<br />
on either 220V, 380V or 415V, 50 Hz supply.<br />
Smoke Fan (542) "Fläkt Woods" JM Aerofoil H.T. Series Axial Fan for Smoke<br />
Extraction System / JM Aerofoil H.T. Series as listed in the<br />
supplementary information sheets to EC-Certificate of<br />
Conformity No. 0086-CPD-474878 of 27.10.2010, but only<br />
limited to those with temperature/time classification equal to<br />
or better than 250 o C and 1 hour (i.e. F300 or better).<br />
Smoke Fan (557) "Elta" Axial Fan / Smoke Vent Series as listed in the<br />
supplementary information sheet to EC-Certificate of<br />
Conformity No. 0086-CPD-493001 of 20.8.2008, but only<br />
limited to those with temperature/time classification equal to<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Kruger Ventilation Industries Pte.<br />
Limited, Singapore<br />
Wolter GmbH Maschinen-und<br />
Apparatebau KG, Germany<br />
12/4/2011 April 2015 The fans shall bear appropriate labels<br />
for the identification of time /<br />
temperature categories.<br />
5/7/2011 July2016 a) Valid "EC-Certificate of Conformity"<br />
shall be maintained for the fan models.<br />
b) A valid certificate for quality<br />
management system shall be<br />
maintained.<br />
Fläkt Woods Limited, UK 18/8/2011 August 2016 a) The family of "JM Aerofoil HT"<br />
Series fans shall bear the appropriate<br />
markings for the identification of<br />
temperature/time classification. b) This<br />
letter supersedes our letter of the<br />
same series dated 11.5.2010 on the<br />
same product series.<br />
Elta Fans Limited, U.K. 2/11/2011 November 2016 The family of "Smoke Vent" Series<br />
fans shall bear the appropriate "CE"<br />
markings for the identification of<br />
temperature / time classification.<br />
400 o Smoke Fan (572)<br />
C and 2 hour (i.e. F400)<br />
"Systemair" AR Axial Smoke Extraction Fan a) AR/AJR<br />
315-2 F300 with "ATT" 1.1kW motor b) AR 1250-4/16<br />
D4(F400) with "ATT" 15kW motor Type and Size: Axial fan<br />
of 315mm and 1,250mm diameter<br />
Systemair Sdn. Bhd., Malaysia 8/3/2012 March 2017<br />
(10) Thermal / Acoustic Insulations<br />
Thermal Insulation (Accessories) Foster 30-80 - Vapor Safe Coating, Colour in White Foster Products Corporation 12/11/2002 November 2012<br />
Thermal Insulation KNAUF-Rock wool Knauf Singapore Pte Ltd. 4/9/2002 May 2012<br />
Thermal Insulation (207) ' Armacell Armaflex' 6mm, 9mm, 13mm, 19mm, 25mm, Armacell (Guangzhou) Limited,<br />
17/5/2007 May 2012<br />
32mm, 40mm & 50mm thick Class 1 Elastomeric Nitrile<br />
based Insulation for Ductwork and Pipwork in Ventilation<br />
Installation<br />
P.R.C.<br />
Thermal Insulation (215) "Kooltherm" Phenolic Foam Thermal Insulation , 20mm -<br />
60mm thick with nominal density of 35kg/m 3<br />
Kingspan Insulation Ltd., U.K. 12/7/2007 July 2012<br />
page27/40
Thermal Insulation (220) "PHENOTHERM" Phenolic Foam Insulation with "Antiblaze<br />
990" Aluminium Foil Facing<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Dongguan Juwun Rubber & Plastic<br />
Products Co., Ltd, PRC<br />
13/8/2007 August 2012<br />
Thermal Insulation (225) "GOODEVER PF" Phenolic Foam Insulation Beijing Goodever Xinxing Building<br />
Material Co., Ltd, Shenzhen<br />
Branch, PRC<br />
21/9/2007 March 2016<br />
Thermal Insulation (264) "Phenotherm" Phenolic Foam Insulation density 80kg/m 3 &<br />
120kg/m 3, 25mm thick "PAL ® Dongguan Juwun Rubber & Plastic 20/3/2008 March 2013<br />
DSF 818" with Aluminium Foil<br />
Facing<br />
Products Co., Ltd, PRC<br />
Acoustic Insulations (277) Foster 32-14 Duct Fas - High VelocityDuct Sealant Foster Products Corporation, USA 19/5/2008 May 2013<br />
Thermal Insulation (278) "Durkflex-FG" Electromeric Nitrile Insulation Material<br />
density 65kg/m3; thickness 25mm & 32 mm<br />
Thermal Insulation (305) "PAL ® " IA 811 and IA 911 - apply for fixing of insulation to<br />
ductwork and pipework<br />
Thermal Insulation (312) "Thermobreak" Thermal Insulation for HVAC System, a<br />
closed cell polyethylene foam insulation material with a<br />
reference colour of (black) charcoal grey, in roll or sheet<br />
form, reinforced with aluminium foil facing on one side and<br />
G60 acrylic PAS adhesived<br />
Thermal Insulation (322) "PHENOTHERM" / A composite insulation material<br />
comprising "Phenotherm" CFC and HCFC free closed cell<br />
phonolic foam faced with "PAL DSF-White 818" (9-layers)<br />
double sided reinforced aluminium foil vapour barrier / 40<br />
kg/m 3 ; 25 mm thick<br />
Durkfee (Wuhan) Insulation<br />
Material Co., Limited, PRC<br />
Thermal Insulation (327) "Bradford" Fibertex Rockwool Insulation material CSR (GuangZhou) Building<br />
Materials Co., Ltd., PRC<br />
Thermal Insulation (323) PIP ALU / A 20 mm thick polyisocyanurate foam having a<br />
nominal density of 35 - 45 kg/m3 faced on both sides with<br />
embossed aluminium foil of 60 - 80 microns thick. One of<br />
the aluminium surfaces is lacquer coated and the other is<br />
coated with an epoxy based<br />
Thermal Insulation (349) Insulflex / Black coloured NBR, PVC closed cell elastomeric<br />
nitrile rubber insulation material<br />
Thermal Insulation (364) Superion / 13 mm / A black colour flexible closed cell<br />
elastomeric nitrile foam insulation material having a density<br />
of 60 - 80 kg/m3<br />
Thermal Insulation (371) PAL R XDF 22/280 o C / Black polymeric coated textile-glass<br />
material 680 g/m 2 ; 0.5 mm thick<br />
26/5/2008 April 2012<br />
Phenotherm Asia Limited 5/8/2008 August 2013<br />
Sekisui Pilon Pty. Ltd., Australia 4/9/2008 September 2013<br />
Phenotherm Asia Limited, PRC 22/10/2008 October 2013 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
Poliuretanos S.A Camino<br />
Matamala s/n, Spain<br />
29/10/2008 October 2012 Test Standard BS 476 Part 4 : 1970<br />
22/10/2008 October 2012<br />
Insulflex Sdn Bhd, Malaysia 19/2/2009 February 2012 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Superion Worldwide Sdn. Bhd.,<br />
Malaysia<br />
29/4/2009 April 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Phenotherm Asia Limited, PRC 11/6/2009 June 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
page28/40
Thermal Insulation (372) CAPAPHEN-K / "CAPAPHEN-K" Phenolic Foam / CFC free<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
phenolic foam with a nominal density of 40 kg/m 3 and<br />
laminated on one face with a double-sided aluminium foil<br />
Thermal Insulation (375) Owens Corning / Owens Corning Fiberglass Duct Liner /<br />
Glasswool duct liner board covered on one side with Glass<br />
Cloth 7628<br />
Thermal Insulation (393) Isoline / 9mm, 19mm and 25mm thick, 65 to 80 kg/m 3 / a<br />
black colour nitrile rubber based closed cell elastomeric<br />
foam insulation in sheet or tube form<br />
United Regent International<br />
Limited., PRC<br />
Owens Corning (China) Investment<br />
Co., Ltd., PRC<br />
Thermal Insulation (397) PHENOTHERM / 40 kg/m 3 ; 25 mm thick / a composite Dongguan Juwun Rubber & Plastic<br />
insulation material comprising "Phenotherm" CFC and<br />
HCFC free closed cell phenolic foam faced with "PAL*DSF-<br />
Black 818" (9-layers) double sided reinforced aluminium foil<br />
vapour barrier<br />
Products Co., Ltd., PRC<br />
Thermal Insulation (400) UniFiber / fiberglass with "PAL R " SSF 515 aluminium foil<br />
facing / 25 mm / 32 kg/m 3 and 25 mm / 64 kg/m 3<br />
Thermal Insulation (417) FiberCoat / Nylon 66 / Short Nylon 66 fibre having an<br />
norminal length of 0.4 mm bonded to hot dip galvanized<br />
steel sheet by a water based adhesive through an<br />
elestrostatic flocking process<br />
11/6/2009 June 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
24/6/2009 June 2012 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire.<br />
L'Isolante K-Flex, Srl, Italy 14/9/2009 September 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
2/11/2009 November 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
UniFiber Manufacturing Ltd., PRC 1/12/2009 December 2012 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Shenzhen Catic & Tai Kee (E&M)<br />
Ltd. and WuXi XinDaZhong Steel<br />
Sheet Co., Ltd., PRC<br />
Thermal Insulation (435) Lucky-PIP / CFC, HCFC, HCF Free Pre-insulated Pipe /<br />
Piping system comprising a basic carrier pipe, a metal<br />
outer jacket of minimum 0.5 mm thick galvanized steel<br />
sheet and an insulation of 35 mm thick polyurethane foam<br />
(48 kg/m 3 Link The Best Company Limited,<br />
) machine-injected between the carrier pipe and<br />
outer jacket. Other information on wall penetration to the<br />
whole assembly is supported by mild steel brackets on both<br />
sides of the wall, pipe clamp and with the annular gap<br />
between the metal outer jacket and the wall tightly packed<br />
by ceramic fibre insulation with a quality equivalent to<br />
"Super Wool 607 Thermal Ceramics"<br />
Hong Kong<br />
Thermal Insulation (442) Ultimate<strong>Air</strong> / P.E. fibre thermal wheel / A grey colour<br />
packed polyester (PE) fibre material of 35 - 40 mm thick<br />
with a density of 96.3 - 104 kg/m 3 for use in a heat recovery<br />
device.<br />
Qiqihaer Ultimate<strong>Air</strong> Ventilation<br />
Equipment Co., Ltd. PRC<br />
14/4/2010 April 2013 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire<br />
condition<br />
4/6/2010 June 2013 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the assembly under fire<br />
condition<br />
17/6/2010 June 2013 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
page29/40
Thermal Insulation (459) T-Max / Polyester insulation layer faced on one side with<br />
aluminium foil<br />
Thermal Insulation (460) Phenotherm TM / Phenotherm TM phenolic foam / A<br />
composite insulation panel comprising a phenolic foam<br />
core having a density of 60 kg/m 3 bonded on both sides<br />
with embossed aluminium foil of a thickness > or = 0.05<br />
mm using PAL LA811 adhesive<br />
Thermal Insulation (471) "OPS" Rigid Insulation Ring / Split composite insulation ring<br />
comprising rigid fire retarded polyurethane, laminated with<br />
0.3 mm thick double-sided aluminium foil as vapour barrier<br />
and protected by 0.8 mm thick galvanized iron sheet jacket<br />
Thermal Insulation (472) "UniFiber R " Fiberglass with Black Glass Tissue (BGT)<br />
Facing / Fiberglass faced on one side with black glass<br />
tissue / 25 mm / 32 Kg/m 3<br />
Thermal Insulation (474) Pilon "Thermobreak" Thermal Insulation / A closed cell<br />
polyethylene foam insulation material with a reference<br />
colour of (black) charcoal grey, in roll or sheet form.<br />
Reinforced with aluminium foil facing on one side and G60<br />
acrylic PAS adhesive backing.<br />
Acoustic insulation (476) "Pyrotek" Wavebar Quadzero Noise Barrier/A 4mm thick<br />
black flexible aluminium foil faced polymer backed by a<br />
white nonwoven polyester fabric/8.14kg/m 2 /for external<br />
acoustic insulation of duckwork<br />
Thermal Insulation (479) "Teembase" Pre-insulated Pipe System / Piping system<br />
comprising a basic carrier pipe, a metal outer jacket of<br />
minimum 0.6 mm thick stainless steel (Grade 304),<br />
galvanized steel or aluminium sheet and an insulation of 15<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
- 75 mm thick polyurethane foam (48 kg/m 3 ) machineinjected<br />
between the carrier pipe and outer jacket.<br />
Thermal Insulation (482) "GOODEVER PF" Phenolic Foam Insulation / Phenolic<br />
foam insulation with a density of 40 kg/m 3 bonded on one<br />
side with 0.22 mm "S-series" thick doubled sided aluminum<br />
facing material using PS 8109S adhesive / thickness: 15<br />
mm - 75 mm<br />
Hueintek Inc., S. Korea 27/8/2010 August 2013 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition..<br />
Dongguan Juwun Rubber & Plastic<br />
Products Co., Ltd., PRC<br />
27/8/2010 August 2015 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition..<br />
Oxprime (International) Ltd., PRC 11/10/2010 October 2013 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
UniFiber Manufacturing Ltd., PRC 18/10/2010 October 2013 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Sekisui Pilon Pty. Ltd., Australia 10/11/2010 September 2013 Test of the material for smoke<br />
generation according to ISO 5659-2<br />
(1994) under fire condition was carried<br />
out by SP Swedish National Testing<br />
and Research Institute with test report<br />
referance P200245 dated 13.2.2002<br />
as a reference.<br />
Pyrotek Pty. Ltd., Australia 6/12/2010 December 2013 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Teembase Development Limited,<br />
PRC<br />
Shenzhen Goodever Xinxing<br />
Building Material Co., Ltd., PRC<br />
14/12/2010 December 2013 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the assembly under fire.<br />
b) A valid assessment report on the<br />
wall penetration seal shall be<br />
maintained.<br />
23/12/2010 September 2015 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
page30/40
Thermal Insulation (483) "FOCUS" Phenolic Foam Insulation / Phenolic foam with<br />
nominal density of 40 kg/m3 and faced on one side with a<br />
layer of reinforced aluminium foil laminate, "Sisalation 450"<br />
by "PLI A911" acetone based synthetic type adhesive /<br />
thickness: 25 mm<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Zhongshan Focus Insulation<br />
Material Factory (聚能新型保溫建<br />
材厂), PRC<br />
Acoustic insulation (484) "Sargents" SILduct Duct Mounted Attenuators / 0.55 mm Luen Wah Machine Welding<br />
thick perforated galvanized sheets front and back skins with Factory, PRC<br />
fibreglass wool infill material wrapped by a 23 micron<br />
"Melinex" film; 0.8 mm thick galvanized steel sheet<br />
perimeter casing<br />
Thermal Insulation (485) ATC "PD5020-80/80" Sandwich <strong>Air</strong> Duct Panel / A<br />
composite insulation panel comprising a core of<br />
polyisocyanurate foam having a nominal density of 48-52<br />
kg/m 3 with 80 micron thick aluminium foil bonded to each<br />
face<br />
Thermal Insulation (487) "Piral MD Hydrotec" <strong>Air</strong> Duct Panel / 15HB21 Piral MD<br />
Hydrotec / A 20 mm thick foam board comprising a core of<br />
polyurethane foam of density 44 kg/m 3 with 60 micron thick<br />
aluminium foil bonded to it on both faces<br />
Acoustic insulation (489) "AES" Rectangular Acoustic Attenuator / The casing is<br />
constructed from 0.8 mm to 1.6 mm thick galvanized steel<br />
plate with a folded joint along one edge of the unit sealed<br />
with silicone mastic sealant. The splitter is fabricated from<br />
0.8 mm thick galvanized perforated steel sheet with "Owens<br />
Cornings" glass fibre (glasswool blanket laminated with<br />
FSK (Lamtec-R3035) of density 40 kg/m 3 Acoustic Engineering Services<br />
packed under<br />
10% compression as the infill material.<br />
(UK) Ltd., PRC<br />
Thermal Insulation (497) "Insutech-PIP" Pre-insulated Pipe System / Piping system<br />
comprising a basic metal carrier pipe, a metal outer jacket<br />
of 0.6 mm thick galvanized steel and an insulation layer of<br />
50 mm thick polyurethane foam (48 kg/m 3 ) machineinjected<br />
between the carrier pipe and outer jacket.<br />
29/12/2010 January 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
7/1/2011 January 2016 a) The fibreglass wool infill material of<br />
the attenuator shall be of a type<br />
conforming to the requirements for<br />
internal insulation stipulated in Part XI<br />
of the FSD Circular Letter No. 4/96.<br />
<strong>Air</strong> Trade Centre Limited, PRC 14/1/2011 July 2015 a) no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
b) the insulation panel should be<br />
marked with "PD5020-80/80"<br />
P3 Srl, Italy 18/1/2011 September 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
Bun Kee Building Materials<br />
(Guangzhou) Co., Ltd., PRC<br />
24/1/2011 December 2012 The glasswool infill material of the<br />
attenuator shall conform to the<br />
requirements for internal insulation<br />
stipulated in Part XI of the FSD<br />
Circular Letter No. 4/96.<br />
18/2/2011 February 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the assembly under fire.<br />
b) Valid assessment report on the<br />
integrity of wall penetration seal to BS<br />
476: Part 20 shall always be made<br />
available.<br />
page31/40
Thermal Insulation (501) "Lucky-PIP" Pre-insulated Pipe System (CFC, HCFC, HCF<br />
Free) / "Lucky-PIP" (CFC, HCFC, HCF Free) Pre-insulated<br />
Pipe (Grade 316 stainless steel jacket) / Piping system<br />
comprising a basic carrier pipe, a metal outer jacket of<br />
minimum 0.5 mm thick Grade 316 stainless steel sheet and<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
an insulation of 35 mm thick polyurethane foam (48 kg/m 3 )<br />
machine-injected between the carrier pipe and outer jacket.<br />
Thermal Insulation (503) "UniFiber ® " Fiberglass with PAL ® DSF 818 Aluminium Foil<br />
Facing / "UniFiber ® " fiberglass with "PAL ® DSF 818"<br />
aluminium foil facing / Fiberglass faced on one side with<br />
"PAL® DSF 818" double sided aluminium foil facing /<br />
Thickness / Density : 25 mm / 32 kg/m 3<br />
Thermal Insulation (504) "Armaflex Duct" Nitrile Based Elastomeric Insulation<br />
Material / Armaflex Duct Thickness 25 mm / "Armaflex"<br />
closed cell nitrile based elastomeric insulation material,<br />
having a density of 46 to 47 kg/m 3 , with glass fabric<br />
reinforced aluminium foil facing on one side.<br />
Acoustic Insulation (509) "Wilhams" Acoustic Noise Barrier Mat / "Wilhams" Type<br />
WB 5 / A 3 mm thickblack barium sulphate loaded<br />
thermoplastic polymer faced on one side with glass<br />
reinforced aluminium foil / Density 5.0 Kg/m 2 .<br />
Thermal Insulation (514) "K-Flex ST" Class 0 Elastomeric Insulation Material for<br />
Insulation of Ventilation Ductwork or Pipework / "K-Flex ST"<br />
/ Black colour closed cell, nitrile rubber based elastomeric<br />
insulation foam product having a density of 45-65 Kg/m 3 .<br />
Thermal Insulation (519) "P-flex" Flexible Elastomeric Closed Cell Insulation / P-flex<br />
® " / A black colour CFCs and HCFCs free flexible<br />
elastomeric closed cell insulation material having a nominal<br />
density of 80 kg/m 3 / 9mm, 13mm, 19mm and 25mm<br />
Acoustic Insulation (520) "Best Bond" FHPEVA Insulation Ring / Split composite<br />
insulation ring comprising high pressure foamed, high<br />
density polyethylene vinyl acetate (PEVA) / 560 kg/m 3 / As<br />
external insulation ring for pipe work<br />
Link The Best Company Limited,<br />
Hong Kong<br />
1/3/2011 March 2016 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
UniFiber Manufacturing Ltd., PRC 7/3/2011 March 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
Armacell (Guangzhou) Limited,<br />
P.R.C.<br />
8/3/2011 March 2016 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
Wilhams Insulation Ltd., U.K. 11/4/2011 April 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire<br />
condition<br />
L'Isolante K-Flex, Srl, Italy (PRC<br />
made)<br />
Dongguan Juwun Rubber & Plastic<br />
Products Co., Ltd., PRC<br />
3/5/2011 May 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire. b)<br />
The product shall bear the marking<br />
"CL 1 DM 26.6.84" for identification<br />
purpose.<br />
1/6/2011 June 2016 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Meriton East (HK) Ltd., PRC 1/6/2011 June 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
page32/40
Thermal Insulation (522) "Insutech-PIP" Pre-insulated Pipe System / Piping system<br />
comprising a basic metal carrier pipe, a metal outer jacket<br />
of 0.6 mm thick galvanized steel, 0.8 mm aluminium sheet<br />
or 0.6 mm thick Grade 316 or Grade 304 stainless steel<br />
sheet and an insulation layer of 50 mm thick rigid<br />
polyurethane foam (48 kg/m 3 ) machine-injected between<br />
the carrier pipe and outer jacket.<br />
Thermal Insulation (527) "BBS" Rockwool Insulation / A yellowish brown mineral<br />
wool sheet having a nominal density between 40 kg/m 3 and<br />
150 kg/m 3<br />
Thermal Insulation (531) "Durkflex� FG" Nitrile Rubber Insulation / Durkflex� FG /<br />
Closed cell nitrile based elastomeric insulation material,<br />
having a density of 60-80 kg/m 3 and with a colour reference<br />
"Black" Thickness : 9 mm and 13 mm<br />
Thermal Insulation (532) "COLAN" AF406/Silicone Glass-Fibre Fabric as Flexible<br />
Connector in Ventilation/Smoke Extraction System /<br />
"COLAN AF406/Silicon" Glass-fibre fabric / A woven<br />
fibreglass fabric with silicon rubber coating on both sides,<br />
having a nominal thickness of 0.46 mm and a normal<br />
weight of 543 g/m 2 and with a standard reference colour<br />
grey.<br />
Thermal Insulation (534) "PAL�" DF16 Class '0' Duct Fabric / "PAL� DF 16 Class '0'<br />
/ A black polymeric coated textile-glass material with an<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
nominal thickness of 0.4 mm and weight of 550 g/m 2 .<br />
Thermal Insulation (536) "AFICO" Type 320 Faced Duct Wrap / "AFICO" Faced Duct<br />
Wrap, Type 320 / A uniformly textured inorganic glass<br />
fibers bonded together by a thermosetting resin and faced<br />
on one side with aluminium foil facing Thickness (mm) /<br />
Density (kg/m 3 ) : 25 mm / 32 kg/m 3<br />
Thermal Insulation (539) "Owens Corning" Fiberglas� All-Service Duct Wrap /<br />
Fiberglas� All-Service Duct Wrap with Heatshield 730 /<br />
Fiberglass blanket insulation material laminated on one<br />
side with Heatshield 730 (a 9-layer reinforced doubled<br />
sided aluminium foil) Density: 32 kg/m 3 Thickness 25 and<br />
50 mm<br />
Bun Kee Building Materials<br />
(Guangzhou) Co., Ltd., PRC<br />
Best Building Suppliers Co., Ltd.<br />
PRC<br />
Durkee (Wuhan) Insulation Material<br />
Co., Ltd., PRC<br />
COLAN Products Pty Ltd.,<br />
Australia<br />
Dongguan Juwun Rubber & Plastic<br />
Products Co., Ltd., PRC<br />
Arabian Fiberglass Insulation<br />
Company Ltd., Saudi Arabia<br />
9/6/2011 June 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the assembly under fire.<br />
b) Valid assessment report on the<br />
integrity of wall penetration seal to BS<br />
476: Part 20 shall always be made<br />
available. c) This letter supersedes our<br />
previous letter of the same series<br />
dated 18.2.2011 on the same product.<br />
13/6/2011 June 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
5/7/2011 July 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire. b)<br />
The material shall bear the marking<br />
"Durkflex� FG" as a means of<br />
identification.<br />
7/7/2011 July 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire. b)<br />
The product shall have label tag(s)<br />
bearing the word "AF 406 SIL" sewn<br />
on it as a means of identification.<br />
21/7/2011 July 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition. b) The brand and model<br />
name should be marked on the<br />
product.<br />
4/8/2011 August 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire. b)<br />
The material shall be installed with the<br />
foil face exposed.<br />
Owens Corning China, PRC 12/8/2011 August 2014 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
page33/40
Thermal Insulation (550) "AFICO" Duct Liner for Ventilation Ducts / "AFICO" Duct<br />
Liner, Type 320 / Uniformly textured inorganic glass fibers<br />
bonded together by a thermosetting resin and faced with a<br />
black glass tissue thickness (mm)/Density (KG/m 3 ) :25 mm<br />
/ 32 kg/m 3<br />
Thermal Insulation (552) "Evertherm" Phenolic Foam Insulation Material with<br />
Aluminium Foil Facing / "Evertherm" Phenolic Foam with<br />
aluminium foil facing / Grey colour closed cell rigid phenolic<br />
foam insulation material with aluminium foil facing and<br />
having a density of 40 kg/m 3<br />
Acoustic Insulation (553) Owens Corning "QuietR" Acoustic Duct Liner / QuietR<br />
Acoustic Duct Liner - Type 200 / A resin bonded fiberglass<br />
blanket faced on one side with acrylic composed carbon<br />
black bound fiberglass veil having a density and a thickness<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
of 32 kg/m 3 and 25 mm respectively.<br />
Acoustic Insulation (555) LAH Glass Wool / A yellowish fiberglass board / blanket of<br />
50 mm thick and density 48 kg/m 3 / As internal acoustic<br />
lining of ductwork<br />
Thermal Insulation (558) "Lucky-PIP" Pre-insulated Pipe System / CFC Free Preinsulated<br />
Pipe<br />
Thermal Insulation (559) "Evertherm" Phenolic Foam Insulation Material with Silver<br />
Embossed Aluminium Foil Facing / "Evertherm" Phenolic<br />
Foam with "Evertherm 980S" silver embossed aluminium<br />
foil facing / Grey colour closed cell rigid phenolic foam<br />
insulation material with a silver aluminium foil facing and<br />
having a density of 40 kg/m3<br />
Thermal Insulation (560) "Superlon" Elastomeric Nitrile Insulation Material / a black<br />
colour flexible closed cell elastomeric nitrile foam material<br />
Thermal Insulation (562) "UniFiber�" Rockwool Insulation /Rockwool without facing<br />
/ Thickness / Density : 50 mm / 140 Kg/m 3<br />
Arabian Fiberglass Insulation<br />
Company Ltd., Saudi Arabia<br />
Evertherm Insulation Hong Kong<br />
Ltd., HK (with phenolic foam from<br />
PRC)<br />
21/9/2011 September 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire. b)<br />
The material shall be installed with the<br />
black glass tissue exposed to the air<br />
stream.<br />
27/9/2011 September 2014 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
Owens Corning, USA 3/10/2011 October 2014 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Luen Wah Machine Welding & Iron<br />
Works Co., Ltd, PRC<br />
Link The Best Company Limited,<br />
Hong Kong<br />
Evertherm Insulation Hong Kong<br />
Ltd., HK (with phenolic foam from<br />
PRC)<br />
Superlon Worldwide Sdn. Bhd.,<br />
Malaysia<br />
18/10/2011 October 2014 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire<br />
condition.<br />
6/12/2011 August 2016 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire<br />
conditions.<br />
9/12/2011 December 2014 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
9/12/2011 December 2014 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
conditions.<br />
UniFiber Manufacturing Ltd., PRC 16/12/2011 December 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by material under fire. b)<br />
The product itself has no markings.<br />
Howerver, details such as brand<br />
name, density and thickness are to be<br />
marked on its packing.<br />
page34/40
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Thermal Insulation (563) "Lucky-PIP" Pre-insulation Pipe System (Grade 304<br />
Stainless Steel Jacket) / "Lucky-PIP" CFC Free Preinsulation<br />
Pipe (Grade 304 Stainless Steel Jacket) / Piping<br />
system comprising a basic carrier pipe, a metal other jacket<br />
of minimum 0.5 mm thick Grade 304 stainless steel, and an<br />
insulation of 35 mm thick polyurethane foam (48 kg/m 3 Link The Best Company Limited,<br />
)<br />
machine-injected between the carrier pipe and outer jacket.<br />
Hong Kong<br />
Thermal Insulation (564) "Lucky-PIP" Pre-insulation Pipe System (Grade 316<br />
Stainless Steel Jacket) / "Lucky-PIP" CFC Free Preinsulation<br />
Pipe (Grade 316 Stainless Steel Jacket) / Piping<br />
system comprising a basic carrier pipe, a metal other jacket<br />
of minimum 0.5 mm thick Grade 316 stainless steel, and an<br />
insulation of 35 mm thick polyurethane foam (48 kg/m 3 Link The Best Company Limited,<br />
)<br />
machine-injected between the carrier pipe and outer jacket.<br />
Hong Kong<br />
Thermal Insulation (565) "AFICO" Fibreglass Duct Wrap (with PAL� DSF 818 Class<br />
0, Double Sided Aluminium Foil Facing) for Ventilation<br />
Ducts / "AFICO" Faced Duct Wrap / "AFICO" glasswool<br />
laminated on one side with PAL� DSF 818 Class 0, 8-layer<br />
double sided reinforced aluminium foil facing / Thickness /<br />
Density : 25 mm / 48 kg/m 3<br />
Thermal Insulation (567) "Insulflex" Closed Cell Nitrile Rubber Insulation Foam /<br />
"Insulflex" / Black coloured closed cell nitrile rubber<br />
insulation material / Thickness and Density : 25 mm, 100<br />
kg/m 3<br />
Acoustic Insulations (568) PAL� "IS918WB" Class '0' Sealant / PAL� "IS918WB" / A<br />
water based industrial sealant with a grey colour<br />
Thermal Insulation (570) "Infung" Phenolic Foam Insulation / A CFC/HCFC free<br />
phenolic foam material faced with 0.2 mm thick aluminium<br />
facing foil Density : 40 kg/m 3 Thickness :15 mm - 75 mm<br />
Thermal Insulation (574) "Lucky-PIP" (CFC, HCFC, HCF Free) Pre-insulated Pipe<br />
(Aluminium jacket) / Piping system comprising a basic<br />
carrier pipe, a metal outer jacket of minimum 0.6 mm thick<br />
aluminium sheet and an insulation of 35 mm thick<br />
polyurethane foam (48 kg/m 3 ) machine-injected between<br />
the carrier pipe and outer jacket.<br />
Arabian Fiberglass Insulation<br />
Company Ltd., Saudi Arabia<br />
Insulflex Corporation Sdn Bhd,<br />
Malaysia<br />
10/1/2012 November 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by assembly under fire. b)<br />
Document demonstrating that reports<br />
WF No. 173898 and WF No. 173897<br />
remain valid shall be made available<br />
for inspection upon request.<br />
9/1/2012 November 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by assembly under fire. b)<br />
Document demonstrating that reports<br />
WF No. 173898 and WF No. 173897<br />
remain valid shall be made available<br />
for inspection upon request.<br />
9/1/2012 January 2017 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire.<br />
20/1/2012 January 2017 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Phenotherm Asia Ltd., PRC 1/2/2012 February 2017 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Jiangmenshi Xinhuiqu Huicheng<br />
Infung Insulation Material Factory<br />
(江門市新會區會城盈豐保溫材料<br />
廠), PRC<br />
Link The Best Company Limited,<br />
Hong Kong<br />
10/2/2012 July 2013 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
conditions.<br />
13/3/2012 March 2016 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
page35/40
Thermal Insulation (575) "Lucky-PIP" CFC Free Pre-insulated Pipe (Aluminium<br />
Jacket) / Piping system comprising a basic metal carrier<br />
pipe with an aluminium outer jacket of minimum 0.6 mm<br />
thick with interlocking seam and an insulation of 35 mm<br />
thick polyurethane foam (48 kg/m 3 ) machine-injected<br />
between the carrier pipe and outer jacket.<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Link The Best Company Limited,<br />
Hong Kong<br />
Thermal Insulation (577) "K-Flex ST" Class 0 Elastomeric Insulation Material for L'Isolante K-Flex, Srl, Italy (PRC<br />
Insulation of Ventilation Ductwork or Pipework / "K-Flex ST"<br />
/ Black colour closed cell, nitrile rubber based elastomeric<br />
insulation foam product having a density of 45-65 Kg/m3.<br />
made)<br />
Thermal Insulation (584) "Armacell Armaflex" / Class 0, closed cell, nitrile based Armacell (Guangzhou) Limited,<br />
flexible elastomeric insulation products (density between 40<br />
kg/m3 and 65 kg/m3) / Thickness: 6mm, 9mm, 13mm,<br />
19mm, 25mm, 30mm, 32mm and 50mm<br />
P.R.C.<br />
Thermal Insulation (591) "PAL ® SSF 515" Class '0' Aluminium Foil Vapour Barrier<br />
Laminated on top of Insulation for Ductwork and Pipe work /<br />
A 5-layer flame retarded tri-directional reinforced aluminium<br />
foil<br />
Thermal Insulation (593) "Certain Teed" Fiberglass Insulation Material / Certain Teed<br />
ToughGard T Textile Liner / A textile-type glass fibres<br />
bonded together with a thermosetting resin overlaid with a<br />
black matt tissue surface on the air stream side. Fiberglass<br />
material having a density and a thickness of 32 kg/m 3 and<br />
25 mm respectively.<br />
19/3/2012 June 2016 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire.<br />
26/4/2012 May 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire. b)<br />
The product shall bear the marking<br />
"CL 1 DM 26.6.84" for identification<br />
purpose.<br />
4/6/2012 June 2017 no assessment was made on the<br />
smoke density and toxicity generated<br />
by the meterials under fire condition.<br />
Phenotherm Asia Limited, PRC 16/7/2012 July 2017 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire. b)<br />
For phenoic foam insulation, the<br />
finished external insulation layer (i.e.<br />
insulation + "PAL® SSF 515" as<br />
vapour barrier) should comply with BS<br />
476 Part 7 (Class 1) c)The product<br />
shall bear the marking "CL 1 DM<br />
26.6.84" for identification purpose.<br />
Certain Teed Corporation, USA 21/8/2012 August 2017 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
conditions. b) The product itself has no<br />
marking, however details such as<br />
brand name, density and thickness are<br />
to be marked on its packing.<br />
page36/40
Thermal Insulation (594) "AFICO" Fiberglass Insulation / Fiberglass wool insulation<br />
with doubled sided aluminium foil vapour barrier /<br />
Thickness / Density : 50 mm / 48 kg/m 3<br />
Thermal Insulation (597) "AmCoolong®" / Black coloured closed cell elastomeric<br />
foam insulation material / Thickness and Density : 19 mm,<br />
64 kg/m 3<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
Arabian Fiberglass Insulation Co.,<br />
Ltd., Saudi Arabia<br />
Long Mass Insulation Material<br />
Factory, PRC<br />
Thermal Insulation (601) "Lucky-PIP" CFC Free Pre-insulation Pipe (Galvanized Link The Best Company Limited,<br />
Steel Jacket) / Piping system comprising a basic steel inner Hong Kong<br />
pipe with a galvanized steel outer jacket of minimum 0.5<br />
mm thick with interlocking seam and an insulation of<br />
polyurethane foam machine-injected between the inner pipe<br />
Thermal Insulationl (602) 'Class 1 Armaflex' / Closed cell, nitrile based flexible<br />
elastomeric insulation products, having a density of about<br />
46 kg/m 3 and with a colour reference "Black" / Thickness: 6<br />
mm and 32 mm<br />
Thermal Insulation (605) "Byucksan rockwool" Thermal Insulation / Material A<br />
yellowish brown mineral wool sheet having a thickness of<br />
50mm and a nominal density of 100kg/m 3<br />
Thermal Insulation (606) "Owens Corning Fiberglass Insulation" FSK (Lamtec-3035)<br />
Faced Board/Pipe Type material / Density 32-64kg/m 3<br />
Thickness 25-50mm<br />
Thermal Insulation (607) "Owens Corning Fiberglass Insulation" FSK (Lamtec-3035)<br />
Faced Blanket Type material / Density 24-48kg/m 3<br />
Thickness 25-50mm<br />
Thermal Insulation (608) "Owens Corning Fiberglass Insulation" DSF (Lamtec-763)<br />
Faced Board/Pipe Type material / Density 32-64kg/m 3<br />
Thickness 25-50mm<br />
Thermal Insulation (609) "Owens Corning Fiberglass Insulation" DSF (Lamtec-763)<br />
Faced Blanket Type material / Density 24-48kg/m 3<br />
Thickness 25-50mm<br />
Armacell (Guangzhou) Limited,<br />
P.R.C.<br />
22/8/2012 August 2017 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire. b)<br />
The product itself has no marking,<br />
however details such as brand name,<br />
density and thickness are to be<br />
marked on its packing.<br />
23/8/2012 July 2016 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
conditions. b) The product shall bear<br />
the "AmCoolong®" marking..<br />
28/8/2012 June 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire.<br />
7/9/2012 September 2017 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the materials under fire<br />
condition.<br />
Byucksan Co. Ltd., S. Korea 15/10/2012 June 2017 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
Owens Corning (Guangzhou)<br />
Fibreglass Co., Ltd., PRC<br />
Owens Corning (Guangzhou)<br />
Fibreglass Co., Ltd., PRC<br />
Owens Corning (Guangzhou)<br />
Fibreglass Co., Ltd., PRC<br />
Owens Corning (Guangzhou)<br />
Fibreglass Co., Ltd., PRC<br />
22/10/2012 October 2017 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
22/10/2012 October 2017 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
22/10/2012 October 2017 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
22/10/2012 October 2017 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
page37/40
Thermal Insulation (610) "AmCoolong®" / Black coloured closed cell elastomeric<br />
foam insulation material / Thickness and Density : 25 mm,<br />
50-80 kg/m 3<br />
Thermal Insulation (611) K-Flex Class 1 / A closed cell, nitrile rubber based<br />
elastomeric insulation foam product with a colour reference<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
black, Thickness ��50mm, 45 to 80 kg/m 3 / Application: for<br />
external insulation of ductwork or pipe-work<br />
Long Mass Insulation Material<br />
Factory, PRC<br />
L'Isolante K-Flex (Suzhou) Co.,<br />
Ltd., PRC<br />
Thermal Insulation (616) "Isophen" CFC free phenolic foam Insulation / CFC free<br />
phenolic foam insulation material with aluminium foil facing<br />
/ Density and Thickness : of 40 kg/m 3 , 25 mm<br />
Thermal Insulation (623) "Durkflex FG" Closed Cell Elastomeric Nitrile Rubber<br />
Insulation Material / "Durkflex FG" / Black coloured closed<br />
cell elastomeric nitrile rubber insulation material / Thickness<br />
and Density : 25 mm, between 50 - 65kg/m 3<br />
Durkee (Wuhan) Insulation Material<br />
Co., Ltd., PRC<br />
Thermal Insulation (624) "Kooltherm" Phenolic Thermal Insulation Material /<br />
Kooltherm / HCFC free, closed cell rigid phenolic foam<br />
insulation faced on one side with aluminium reinforced foil<br />
laminate by spray adhesive Density and Thickness: 40, 60,<br />
Isotherm Ltd., Hong Kong 27/11/2012 November 2017<br />
Kingspan Tarec Industrial<br />
Insulation N.V., Belgium<br />
22/10/2012 October 2017 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
conditions. b) The product shall bear<br />
the "AmCoolong®" marking..<br />
22/10/2012 October 2017 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
21/12/2012 December 2017 a) No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
conditions b) The product shall bear<br />
the marking "Durkflex FG" as a means<br />
if identification<br />
24/12/2012 December 2017 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
80 and 120 kg/m 3 , 25mm<br />
(11) Miscellaneous<br />
Limit Thermostat Hi-Limit Thermostat - HLD (81) Supplier : HRW Limited 16/6/2005<br />
Duct Sealant (277) Foster 32-19 Duct Fas - Duct Sealant Foster Products Corporation 8/11/2002 November 2012<br />
Self-adhesive Foil Tape (366) PAL AT38 and AT38W / a) AT38 - High strength aluminium Phenotherm Asia Ltd., PRC 4/5/2009 May 2014 no assessment was made on the<br />
foil (38 micron) coated on one side with permanent<br />
density and toxicity of smoke<br />
synthetic rubber resin adhesive b) AT38W - High strength<br />
generated by the material under fire<br />
aluminium foil (38 micron) with a white surface finish on the<br />
external side and coated on the other side with permanent<br />
synthetic rubber resin adhesive<br />
condition.<br />
Sealant (376) PAL IS918 / Class '0' / A synthetic rubber based compound<br />
with a dark grey to black colour<br />
Aluminium Foil Tape (378) INFUNG / AF-045 / High strength aluminium foil (30 Micron)<br />
coated on one side with acrylic adhesive<br />
Phenotherm Asia Ltd., PRC 24/6/2009 June 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Jiangyin Bond Tape Technology<br />
Corporation, PRC<br />
3/7/2009 July 2012 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
page38/40
Sealant Tape (388) PAL R TC 98 / / A polymeric butyl rubber based compound<br />
with a dark grey to black colour<br />
116A Adhesive (438) Isobond 116A / For the bonding of insulation materials, e.g.<br />
fiberglass and phenolic foam, to metal ductwork in<br />
mechanical ventilation system<br />
Rubber Insulation Adhesive<br />
(448)<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
PAL R 1A 911 WB / A water based synthetic elastomer<br />
adhesive with grey colour<br />
Self-adhesive Foil Tape (463) PAL AT38B / 38 micron thick aluminium foil coated on one<br />
side with synthetic rubber resin adhesive<br />
Phenotherm Asia Ltd., PRC 4/8/2009 August 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Isotherm Ltd., PRC 8/6/2010 June 2013 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Phenotherm Asia Ltd., PRC 7/7/2010 July 2015 No assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Phenotherm Asia Ltd., PRC 8/9/2010 September 2015 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />
Aluminium Foil Tape (480) INSUL-PHEN "CW FRT" Aluminium Foil Tape / 30 micron INSUL-PHEN Insulation Ltd., PRC 22/12/2010 December 2015 no assessment was made on the<br />
thick aluminium foil coated on one side with flame-retardant<br />
density and toxicity of smoke<br />
acrylic adhesive / Sealing of joints in ventilation duct work<br />
generated by the material under fire<br />
or pipe work.<br />
condition.<br />
Aluminium Foil Tape (481) INSUL-PHEN "CW FRWT" Aluminium Foil Tape / 30 INSUL-PHEN Insulation Ltd., PRC 22/12/2010 December 2015 no assessment was made on the<br />
micron thick aluminium foil coated with white lacquer on<br />
density and toxicity of smoke<br />
one side and the other side with flame-retardant acrylic<br />
generated by the material under fire<br />
adhesive / Sealing of joints in ventilation duct work or pipe<br />
work.<br />
condition.<br />
Aluminium Foil Facing (503) "UniFiber ® " Fiberglass with PAL ® DSF 818 Aluminium Foil<br />
Facing / "UniFiber ® " fiberglass with "PAL ® DSF 818"<br />
aluminium foil facing / Fiberglass faced on one side with<br />
"PAL® DSF 818" double sided aluminium foil facing /<br />
Thickness / Density : 25 mm / 32 kg/m 3<br />
UniFiber Manufacturing Ltd., PRC 7/3/2011 March 2014 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire.<br />
BB388 Self Adhesive Aluminium "Best Bond" BB388 Self Adhesive Aluminium Foil Tape / Meriton East (HK) Ltd., PRC 30/5/2011 May 2014 no assessment was made on the<br />
Foil Tape (518)<br />
"Best Bond" BB388 / Bright aluminum foil with a nominal<br />
density and toxicity of smoke<br />
thickness of 30 micron coated with flame retardant acrylic<br />
generated by the material under fire<br />
adhesive<br />
condition.<br />
Aluminium Foil Facing (589) "UniFiber ® " Fiberglass Insulation with PAL ® DSF 818<br />
Double Sided Aluminium Foil Facing / "UniFiber ® "<br />
fiberglass with "PAL ® DSF 818" aluminium foil facing /<br />
Fiberglass wool insulation with doubled sided aluminium foil<br />
vapour barrier / Thickness/Density : 50 mm / 64 kg/m 3<br />
UniFiber Manufacturing Ltd., PRC 6/7/2012 July 2017 a) no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire. b)<br />
The product itself has no markings,<br />
however, details such as brand name,<br />
density and thickness are to be<br />
marked on its packing.<br />
page39/40
Glass Tape as Gasket (595) "COLAN TTW 30" Glass Tape / a) 'E' type texturised yams<br />
b) 3mm thick & 50 mm wide c) Density of 2794kg/cu.m<br />
approx.<br />
Aluminium Foil Tape (598) "INFUNG" AF045 / High strength aluminium foil (30 micron)<br />
tape coated on one side with acrylic adhesive / Application:<br />
For the sealing of joints in ventilation system<br />
VENTILATION DIVISION OF FIRE SERVICES DEPARTMENT<br />
LIST OF ACCEPTED MATERIALS FOR USE IN VENTILATION / FIRE SERVICE RELATED SYSTEMS<br />
COLAN Products Pty Ltd.,<br />
Australia<br />
Jiangyin BondTape Technology<br />
Corporation, PRC<br />
22/8/2012 August 2017 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the product under fire<br />
condition.<br />
23/8/2012 August 2017 no assessment was made on the<br />
density and toxicity of smoke<br />
generated by the material under fire<br />
condition.<br />