8 MECHANICAL ALTERNATORS TYPES CG, CW, CR Type CG APPROXIMATE DIMENSIONS Type CG Net Weight - ?Y2 Pounds Approx. TypeCR, CW Net Weight - 21 Pounds Approx. ! r-r, l j '�: :_ -- - -7 15�-- -- --- www www . . <strong>Electrical</strong><strong>Part</strong><strong>Manuals</strong> <strong>Electrical</strong><strong>Part</strong><strong>Manuals</strong> . . com ---- -- -- -- -- -- -- -- -- -- -- -- -- -- �- - - SQUARED COMPANY IDI
Revised Oct., 1983 MECHANICAL ALTERNATORS TYPES DG, OW, DR BUILD UP THE SWITCH TO MEET YOUR REQUIREMENTS FROM THE BASIC SWITCH, ROD AND FLOAT GROUPS BELOW. EXPLANATION OF FLOAT TRAVEL AND POSITION NORMAL OPERATION: Switches will cut in and cut out at the high point and low point of distance A plus B, given in the tables. Under normal conditions, as long as one pump alone is able to handle the incoming water, the pumps will alternate at this distance. With the water Type DG Shown with Rod Kit level continuing to rise, the second switch will cut in and start the second 9049 ER·5, pump when the float reaches the top of distance D. Both pumps will and Float Kit continue to run until the float returns to the low point of distance D plus 9049 HF -3 installed C, where one pump will cut out. The other pump will continue until the float reaches the low point of distance B. REVERSE OPERATION (FORM R): Both pumps will be running with the float at the low point of distance B. With the float rising to the top of distance B plus A, one pump will stop and the other continue until the float reaches the high point of distance D. Both pumps will alternate between the distance C plus D. These devices use graphite coated asbestos packing and are limited to 50 P.S.I. tank pressure. FLANGE MoQN'riD �LJ'ERJUTOR5 {BASIC SWITCHES) CLASS 9038 CONTACTS CLOSE ON LIQUID RISE CONTROL OF LIQUID LEVEL WITHIN CLOSED TANKS Water Level Hinge Post Dimension NEMA 1 NEMA 4 NEMA 7 and 9* Poles Change "V" Type Price Type Price Type Price Min. 2%" DG·? $167. OW·? $438. DR·? Two 2 Pole Max. DG·8 167. DW-8 438. DR·8 Units Min. 411f1s" DG·9 167. DW-9 438. DR·9 Max. DG·10 167. DW·10 438. DR·10 * Su1table for hazardous locations <strong>Class</strong> 1, diVISions 1 and 2, Groups C and D: <strong>Class</strong> 2, diVISIOns 1 and 2, Groups E. F and G SELECT CLASS 9049 ROD KITS FROM THESE TABLES OF FLOAT TRAVEL ADJUSTMENTS Type DG Li flOAT KIT$ fOR USE WITH 90380 Size and Material <strong>Class</strong> and Type Price Diameter x Length 3%" X 4W', #302 S.S. <strong>Class</strong> 9049 Type EF ·1 $12. 3%"x 4Y2'', #316 S.S. <strong>Class</strong> 9049 Type EF·2 27. 2W' X 7", #302 S.S. <strong>Class</strong> 9049 Type HF·3 13. 2Y2'' X 7", #316 S.S. <strong>Class</strong> 9049 Type HF ·4 41. AVAILABLE MODIFICATIONS Manual transfer selector switch . . .......... Form N3 add $21. (see 9038 Type A for details) Two level, non-alternating unit . . .Form N4 add 21. Reverse action (contacts open on rise) ...... Form R N.C. <strong>Electrical</strong> Ratings - see page 11 . Rod Kit Ctass $049 Type ER-1 Type ER·2 Type ER-3 Type ER·5 Type ER· 7 Type ER·12 RQdl(lt Cliiss 9049 ·· Type ER-1 Type ER·2 Type ER-3 Type ER·5 Type ER· 7 Type ER·12 RodKlt · Cla$!i 9049 Type ER·1 Type ER·2 Type ER-3 Type ER·5 Type ER· 7 Type ER·12 ROdKlt. C!Us$049. Type ER·1 Type ER·2 Type ER-3 Type ER-5 Type ER· 7 Type ER·12 r;:::;J � S[JURRE D CDMPRNY ---- -- -- - 078 DISCOUNT 9038 TYPE DG-7, DR-7, DW-7 "V" = 2%" (MINIMUM LEVEL CHANGE) Minimum Travel Maximum Travel "R" e"H" G A B c D F G A B c D H'•" 8v." 1" '¥4 ' 5" 4" 1'¥4 ' 6'¥4" 1W' % " 5" 4W' 1V2" 21f2" 9" 1" %" 5%" 4114" 1'¥4" 7Ye" 1Y2'' %" 5Y4" 4112" 1%" 3W' 9W' 1" Vz" 5W' 4%" 1'¥•" 7W' 1W' 1f4" 5W' 4%" 1v .' ' 5Y4" 11'¥4" 1" Ya" 6%" 5" 1'¥4" 81Js" H'4" 0 6W' 5Vo" 1" 7%" 13"'" 1" %" 7" SVz" 1'¥4'' 8'¥4" 2" Vz" 7" 5'¥4" 7/s " 12v.'' 18"'" 1" %" 8%" 6'¥4'' 1'¥4 ' 10%" 2W' 1W' 8'¥4'' 7'¥4" %" 9038 TYPE DG-8, DR-8, DW-8 "V" = 2%" (MAXIMUM LEVEL CHANGE) Minimum Travel Maximum Travel "R" e "H " G A B c D F G A B c D* H'•" 7V•" 1W' 0 8" 6W' 2" 10" 2Y2" 1v.'' 8" 6W' Y2" 2W' 8W' 11Jz" 1f2" 8'¥4'' 7" 1'¥•" 10W' 2'¥•" 1W' 8'¥4" 7" Y4" 3Y4" 9" H'4" 1" 9W' 7'¥4" 1W' 11" 3" 2" 9Yz" 7'12'' 0 51/4" 11" 2" 2" 11W' 9W' 1W' 12'¥4" 3'¥4" 3" 11W' 9" ¥4'' 12V4'' 18" 2V4'' SW' 18W' 14'¥4" 1f2" 19" 6V4'' 6W' 18W' 15" 4v.'' 9038 TYPE DG-9, DR-9, DW-9 "V" = 411ilo" (MINIMUM LEVEL CHANGE) Minimum Travel Maximum Travel "R" e"H" G A B c D F G A B c D 1l4" 81!4" 3" 1" 5W' 4V2" 2" 71!4" 31,/o" 1f2" 51!4" 41f2" 1Yz" 2112" 9" 3" 1" 5"'" 4"'" 2" 7'¥•" 4" Ya" 5%" 4'¥4" 11!4" 3V4 ' 9W' 3" Ya" 6" 5" 2" 8" 4" 0 5'/o ' 5" 1Vo" 51f4" 11'¥4" 3" %" 7W' 5'¥4" 2" 9Y4'' 4%" 1fa" 71fa" 5'/o'' '¥4" 7W' 13"'" 3V4'' Y4" 8W' 6W' 1 7/ o" 10Vo" 4%" 1%" 8V4 ' 6'¥4" 1f2" 12V4'' 18'¥4" 4" Ya" 10'¥4" 8%" 1%" 12%" 5'¥4'' 2'/o'' 11" 8W' 112" 9038 TYPE DG-10, DR-10, DW-10 "V" = 4"ilo" (MAXIMUM LEVEL CHANGE) Minimum Travel Maximum Travel "R" e"H" G A B c D F G A B c D* 1'¥4" 7W' 3W' Y2" 8" 7" 1'¥4" 8'¥4" 4'¥4" 1V2" 8" 7" 11z" 2W' 8V4'' 3V•" 1" 8'¥4" 7'¥4" 1'¥4" 10V2" 5" 2" 8'¥4" 7V." V4" 3V4 ' 9" 3W' 1V2 ' 9V•" 8V4 ' 1V2'' 11" 5Y4" 2W' 9V." Bv." 0 5V4 ' 11" 3'¥4" 2V2 ' 11W' 10" 1V4'' 12'¥4" 6" 4" 11V." 10" 1" 7V4 ' 13" 4" 3W' 13W' 11W' 1" 14W' 6'¥4" SY2" 13W' 12" 1Vz" 12v." 18" 4'¥4" 6" 18W' 15W' Y2" 19" 8W' 9V4'' 18W' 17" 2'¥4" • Add 2'h" to "H" If using 7" Long Floats, 9049 HF-3 or HF-4, * "D" will be negative when the top of the float I• below the hortzontel centerline. $432. 432. 432. 432. F 6Y2'' 6%" 6'¥4" 7W' 77fo'' 9%" F 8W' 9" 9W' 10'¥4" 7%" 13" 2" 3" 13W' 11" ¥4'' 14v.' ' 41f2" 4" 13W' 10'¥4" 1'¥4" 11'¥4" www www . . <strong>Electrical</strong><strong>Part</strong><strong>Manuals</strong> <strong>Electrical</strong><strong>Part</strong><strong>Manuals</strong> . . com 14V4 ' F 6¥4" 6'/o'' 7" 7718" 8'¥4" 11V2 ' F 8V2'' 9" 9V2" 10V2'' 12" 15'¥4" Price $5. 5. 5. 5. 5. 5. Price $5. 5. 5. 5. 5. 5. Price $5. 5. 5. 5. 5. 5. Price $5. 5. 5. 5. 5. 5. 9